ADR-3 - Pairui

AC-DC Converter
DIP-Package
ADR-3 Series, 3Watt
FEATURES:
Universal AC input range
Typical Efficiency up to 70%
Short circuit, over current and over voltage protections
Board in-line type installation
High voltage isolation 4000Vac
100% burn-in test
3 year warranty
Output voltage
(Vdc)
Output current
(mA)
Efficiency
Typ.
ADR3-3
3.3
909
69%
ADR3-5
5
600
69%
9
333
70%
12
250
70%
ADR3-15
15
200
70%
ADR3-24
24
125
70%
Model
ADR3-9
ADR3-12
Input voltage
(Vac)
85-264
Note: You may request for the models without case, change the prefix “A” to “O”, e.g. ODR3-3.
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
--
85
--
264
Vac
Input frequency
Fline
--
47
--
63
Hz
Full load, Vin =115Vac
--
74
--
mA
Full load, Vin =230Vac
--
37
--
mA
Iinrush
Cold start, Vin =230Vac
--
40
--
A
η
Full voltage, full load
--
70
--
%
Input current
Inrush current
Efficiency
Iin
Output
Output voltage accuracy
Line regulation
www.pairuigroup.com
--
Vin=100-240Vac
--
1
--
%
Vout-line
Vin from 100Vac to 240Vac
--
0.5
--
%
Page:
1/4
Date: 07/30/2015
*Subject to change without notice
AC-DC Converter
DIP-Package
ADR-3 Series, 3Watt
ELECTRICAL
Output
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Load regulation
Vout-load
20%-100% load
--
1
--
%
Set-up rise time
--
Full load, Vin =230Vac
--
25
--
Full load, Vin =115Vac
--
8
--
ms
Full load, Vin =230Vac
--
40
--
ms
--
--
60
--
mV
-40
--
+85
℃
-25
--
+70
℃
10
--
90
%
450
--
--
kHrs
Hold-up time
Ripple
ms
--
Vripple
Protection
Overload
Typ.125-190%
Overvoltage
Typ.125-190%
Environment
Storage
Ambient operating
temperature
Operating relative
humidity
MTBF
Tstorage
Humidity: 5% RH to 95% RH
Startup at rated voltage
Ta
(Please refer to derating curve)
Ha
Non condensing
TMTBF
Full load, 230Vac input,
25
℃
ambient temperature
Dimension(LxWxH)
25.4 x 25.4 x 15.24mm
Safety
Safety standards
EN609501-1, EN60950-1
Withstand voltage
I/P-O/P: 4KVac
Insulation Resistance
I/P-O/P: 100M Ohms/500VDC/25 /70%RH
EMI / RFI conducted
EN55022, Level B conducted & radiated
>
℃
℃ and
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25
input nominal voltage.
www.pairuigroup.com
Page:
2/4
Date: 07/30/2015
*Subject to change without notice
AC-DC Converter
DIP-Package
ADR-3 Series, 3Watt
MECHANICAL
ENCAPSULATED TYPE
CONNECTION
PIN #
SINGLE
1
AC(N)
2
AC(L)
3
NC
4
-Vo
5
+Vo
Note: Unit is mm(inch).
OPEN TYPE
ELECTRICAL CURVE
DERATING CURVE
www.pairuigroup.com
STATIC CHARACTERISTIC CURVE
Page:
3/4
Date: 07/30/2015
*Subject to change without notice
AC-DC Converter
DIP-Package
ADR-3 Series, 3Watt
NOTE
RECOMMENDED TEST AND APPLICATION CIRCUIT
EMC RECOMMENDED APPLICATION CIRCUIT
3.3VDC
5VDC
9VDC
12VDC
F1
T1A/250V
RT1
7D471K
R1, R2
2Ω/3W
R3
1MΩ/2W
L1
L=3-10mH, I=0.2-0.5A
CX1, CX2
0.15-1μF/300Vac
CY1, CY2
102K/400Vac
C3
1μF/50V
15VDC
24VDC
C4
470uF/16V
470uF/16V
150uF/25V
120uF/25V
120uF/25V
100uF/35V
Z1
P6KE6.8A
P6KE6.8A
P6KE16A
P6KE16A
P6KE20A
P6KE33A
www.pairuigroup.com
Page:
4/4
Date: 07/30/2015
*Subject to change without notice