AC-DC Converter DIP-Package ADR-3 Series, 3Watt FEATURES: Universal AC input range Typical Efficiency up to 70% Short circuit, over current and over voltage protections Board in-line type installation High voltage isolation 4000Vac 100% burn-in test 3 year warranty Output voltage (Vdc) Output current (mA) Efficiency Typ. ADR3-3 3.3 909 69% ADR3-5 5 600 69% 9 333 70% 12 250 70% ADR3-15 15 200 70% ADR3-24 24 125 70% Model ADR3-9 ADR3-12 Input voltage (Vac) 85-264 Note: You may request for the models without case, change the prefix “A” to “O”, e.g. ODR3-3. ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin -- 85 -- 264 Vac Input frequency Fline -- 47 -- 63 Hz Full load, Vin =115Vac -- 74 -- mA Full load, Vin =230Vac -- 37 -- mA Iinrush Cold start, Vin =230Vac -- 40 -- A η Full voltage, full load -- 70 -- % Input current Inrush current Efficiency Iin Output Output voltage accuracy Line regulation www.pairuigroup.com -- Vin=100-240Vac -- 1 -- % Vout-line Vin from 100Vac to 240Vac -- 0.5 -- % Page: 1/4 Date: 07/30/2015 *Subject to change without notice AC-DC Converter DIP-Package ADR-3 Series, 3Watt ELECTRICAL Output Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Load regulation Vout-load 20%-100% load -- 1 -- % Set-up rise time -- Full load, Vin =230Vac -- 25 -- Full load, Vin =115Vac -- 8 -- ms Full load, Vin =230Vac -- 40 -- ms -- -- 60 -- mV -40 -- +85 ℃ -25 -- +70 ℃ 10 -- 90 % 450 -- -- kHrs Hold-up time Ripple ms -- Vripple Protection Overload Typ.125-190% Overvoltage Typ.125-190% Environment Storage Ambient operating temperature Operating relative humidity MTBF Tstorage Humidity: 5% RH to 95% RH Startup at rated voltage Ta (Please refer to derating curve) Ha Non condensing TMTBF Full load, 230Vac input, 25 ℃ ambient temperature Dimension(LxWxH) 25.4 x 25.4 x 15.24mm Safety Safety standards EN609501-1, EN60950-1 Withstand voltage I/P-O/P: 4KVac Insulation Resistance I/P-O/P: 100M Ohms/500VDC/25 /70%RH EMI / RFI conducted EN55022, Level B conducted & radiated > ℃ ℃ and Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 input nominal voltage. www.pairuigroup.com Page: 2/4 Date: 07/30/2015 *Subject to change without notice AC-DC Converter DIP-Package ADR-3 Series, 3Watt MECHANICAL ENCAPSULATED TYPE CONNECTION PIN # SINGLE 1 AC(N) 2 AC(L) 3 NC 4 -Vo 5 +Vo Note: Unit is mm(inch). OPEN TYPE ELECTRICAL CURVE DERATING CURVE www.pairuigroup.com STATIC CHARACTERISTIC CURVE Page: 3/4 Date: 07/30/2015 *Subject to change without notice AC-DC Converter DIP-Package ADR-3 Series, 3Watt NOTE RECOMMENDED TEST AND APPLICATION CIRCUIT EMC RECOMMENDED APPLICATION CIRCUIT 3.3VDC 5VDC 9VDC 12VDC F1 T1A/250V RT1 7D471K R1, R2 2Ω/3W R3 1MΩ/2W L1 L=3-10mH, I=0.2-0.5A CX1, CX2 0.15-1μF/300Vac CY1, CY2 102K/400Vac C3 1μF/50V 15VDC 24VDC C4 470uF/16V 470uF/16V 150uF/25V 120uF/25V 120uF/25V 100uF/35V Z1 P6KE6.8A P6KE6.8A P6KE16A P6KE16A P6KE20A P6KE33A www.pairuigroup.com Page: 4/4 Date: 07/30/2015 *Subject to change without notice