DC-AC INVERTER UNIT - Power

DC-AC INVERTER UNIT
PS-DA0271-107 (S) (9 W DUAL OUTPUTS)
DESCRIPTION :
This DC/AC Inverter is developed for many kinds of LCDs
And optimized for NEC: NL8060BC31-27
NEC: NL8060BC31-42
APPLICABLE LCD:
10 to 15 inches dual lamps
Lamp Voltage 570 Vrms
Lamp Current 2 x 5.0 mArms
Lamp Start Up Voltage 1.700 Vrms (Vin : 12 Vdc)
FEATURES :
Current feedback circuit
High efficiency
Low noise with voltage resonant circuit
Regulated output current
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
-10°C ~ +60°C
-20°C ~ +85°C
95 %RH max
153 x 21.5 x 10 mm
Unit : mm
Weight :27 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2
Input side CN1:
Pin No.
CN 1-1+2
CN 1-3+4
Symbols
Vin
GND
CN 1-5
Vrm t
CN 1-6
CN 1-7
N.C.
Vbr
Qty.
1
1
1
Material
UL94V-0 (FR-4 or CEM-3)
53261-0790
SM04(4.0)B-BHS-1-TB
Output side CN2
Pin No.
Symbols
Vhigh
CN 2-1
Vhigh
CN 2-2
N.C.
CN 2-3
Vlow
CN 2-4
Ratings
9.6 ~ 14.4 Vdc
0 ~ 0.4 = OFF
/ 2.5 ~ 5 Vdc = ON
Note
1,6 m m
Molex or equal
JST or equal
Ratings
570 Vrm s (5.0 m Arm s )
570 Vrm s (5.0 m Arm s )
(GND)
0 ~ 3.4 Vdc
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 2.2.3, 19th May 2014
DC-AC INVERTER UNIT
PS-DA0271-107 (S) (9 W DUAL OUTPUTS)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shutdown
Iout
Iout
Iin
F
Vopen
Ts d
Note 1 :
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
Specification
Min.
Typ.
Max.
4.5
1.7
32.5
1.500
-
5.0
2.0
0.75
40
1.700
1.0
5.5
2.4
1.0
47.5
1.900
-
Unit
Note
m Arm s
m Arm s
Adc
kHz
Vrm s
s ec
Dut y 100%
V b r = 3 .4V dc
wit hout load
Please keep a minimum of 2mm clearance in all directions between inverter high voltage areas
and any conductors as marked on mechanical drawing.
.
TEST
CIRCUIT :
Vin
10.8 ~ 13.2 V
Vin (V)
Conditions
Vrmt
Tu (°C)
(V)
5±0.25 -10 ~ +60
5±0.25 -10 ~ +60
5±0.25 -10 ~ +60
5±0.25 -10 ~ +60
5±0.25 -10 ~ +60
5±0.25 -10 ~ +60
F
Iin
A
1000:1
PROBE
F
SW 1
Vopen
V
~
CN1-1
CN1-2
V
Operation of unit
a
Operation
b
Non operation
CN1-3
CN2-1
CN1-4
Vrmt
0 / 5 Vdc
CN2-2
a
V
b
SW3
T1
RL2
SW1
RL1
CN1-5
CL2
CN2-3
A
Iout ~
2
CL1
A
~
Iout1
SW4
N.C.
CN1-6
CN2-4
CN1-7
Vbr
0 ~ 3.4 Vdc
V
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)