POWER-SYSTEMS PS-DA0201-170-B

DC-AC INVERTER UNIT
PS-DA0201-170-B(S) (10 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Optimized for Sharp: LQ150X1LG71_TL_LD-19251C 20070220
LQ150X1LG81_TL_LD-19356A 20070319
APPLICABLE LCD:
6.4 to 15 inches double lamp type
Lamp Voltage 675 Vrms
Lamp Current 2 x 6.5 mArms
Lamp Start Up Voltage 1.680 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open Lamp Detection
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
0°C ~ +60°C
-40°C ~ +85°C
95 %RH max
160 x 25 x 12 mm
Pin 1
Pin 1
Unit : mm
Weight :24,2 (g) typ.
Pin 1
Pin 1
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
Part Description
PCB
Connector CN1
Qty.
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-K
Note
t=1m m
JST or equal
3
Connector CN2 + CN3
2
SM02(8.0)B-BHS-1-TB
JST or equal
Output side CN2:
Input side CN1:
Pin No.
CN 1-1
CN 1-2
CN 1-3
CN 1-4
Symbols
Vin
GND
Vrm t
Vbr
Ratings
10.8 ~ 13.2 Vdc
0 ~ 0.4 = OFF / 2.5 ~ Vin = ON
0 ~ 2.5 Vdc
CN 1-5
N.C.
-
Pin No.
CN 2-1
Symbols
Vhigh
Ratings
675 Vrm s (6.5 m Arm s )
CN 2-2
Vlow
(GND)
Output side CN3:
Pin No.
CN 3-1
Symbols
Vhigh
Ratings
675 Vrm s (6.5 m Arm s )
CN 3-2
Vlow
(GND)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0.2; 7th July 2008
DC-AC INVERTER UNIT
PS-DA0201-170-B(S) (10 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Conditions
Specification
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
12±1.2
12±0.6
12±1.2
12±1.2
11.4
0.0
2.5
0.0
0.0
0.0
0
0
0
0
0
Ts d
12±1.2
0.0
0 ~ +60
No load Shutdow n
Note 1 :
Vin (V)
Vbr (V) Tu (°C)
~ +60
~ +60
~ +60
~ +60
~ +60
Unit
Note
7.0
1.2
70
1.900
m Arm s
%
Adc
kHz
Vrm s
Dut y 10 0%
-
s ec
wit hout load
Min.
Typ.
Max.
6.0
40
1.680
6.5
20
0.88
60
1.750
-
1.0
Dut y M in
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
F
A
Vin
12 V
Iin
1000:1
PROBE
F
CN1-1
CN2-1
a
V
b
Operation of unit
a
Operation
b
Non operation
SW3
V
CN1-2
Vrmt
0.4 / 5 Vdc
SW 1
Vopen V
~
SW1
CN1-3
CL1
RL1
A
~
T1
CN2-2
SW4
Iout1
SW5
CN1-4
Vbr
0 ~ 2.5 Vdc
CN3-1
CL2
RL2
N.C.
CN1-5
CN3-2
SW6
A
~
Iout2
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)