Lens Datasheet - Pixart Imaging Inc.

ADNS-6150
Small Form Factor Lens
Description
t C
on
fid
en
tia
l
Data Sheet
Pix
Ar
The ADNS-6150 small form factor (SFF) laser mouse lens is designed for use with PixArt Imaging ADNS-7530 and
ADNS-7550 LaserStream™ sensors. Together with the VCSEL, the ADNS-6150 SFF lens provides the directed illumination and optical imaging necessary for proper operation of the sensor. ADNS-6150 SFF lens is a precision molded
optical component and should be handled with care to avoid scratching of the optical surfaces.
Notes:
1. Dimensions in millimeters/inches.
2. Dimensional tolerance: ± 0.10mm
3. Angular tolerance: ± 3°
4. Maximum flash: ± 0.20mm
5. ( ) Reference Dimension
Figure 1. ADNS-6150 SFF lens outline drawings and details
All specifications reference Figure 2 and Figure 3, Optical System Assembly Diagram
l
Mechanical Assembly Requirements
Symbol
Min.
Typ.
Max.
Units
Conditions
Distance from Object Surface
to Lens Reference Plane
A
2.18
2.40
2.62
mm
For ADNS-6150 with ADNS-7550 and ADNS-7530
sensors
Distance from Object Surface
to Sensor Pin Reference Plane
B
mm
ADNS-7550 or ADNS-7530 Sensor Pin Reference
Plane must be in contact with Lens Housing
Surface
nfi
de
n
8.35
tia
Parameters
Lens Design Optical Performance Specifications
All specifications are based on the Mechanical Assembly Requirements.
Parameters
Symbol
Design Wavelength
λ
Lens Material* Index of Refraction
N
Min.
Typ.
Max.
842
1.5693
Units
Conditions
nm
1.5713
1.5735
λ = 842 nm
*Lens material is polycarbonate. Cyanoacrylate based adhesives should not be used as they will cause lens material deformation.
Co
ADNS-7550 or ADNS-7530 sensor
B
ADNS-6150 Lens
A
Object Surface
Pix
Ar
t
Figure 2. ADNS-7550 and ADNS-7530 optical system assembly (front view)
2
Figure 3. PixArt Imaging logo location
Mounting Instructions for the ADNS-6150 SFF Laser Mouse Lens to the Base Plate
tia
l
An STEP or IGES format drawing file with design specifications for laser mouse base plate features is available. These
features are useful in maintaining proper positioning and alignment of the ADNS-6150 SFF lens when used with the
PixArt Imaging ADNS-7530 or ADNS-7550 LaserStream™ sensor. This file can be obtained by contacting your local
PixArt Imaging sales representative.
nfi
de
n
ADNS-6150 SFF Lens
Customer Supplied
Base Plate
Pix
Ar
t
Co
Figure 4. Illustration of base plate mounting features for ADNS-6150 SFF lens
All rights reserved. No reproduce, copy or transform any portion is allowed.
Data subject to change.
PixArt Imaging Inc.