AP117/AP117A Rad-Hard Adjustable Positive Linear Voltage Regulator Features • Rad-Hard to 300 krad TID 1 • Single Event, latch-up immune (LET= 87 MeV/mg/cm2) • Wide Input/Output Voltage Differential: 40V • K-level screening • Excellent Temperature Stability The AP117/117A are space qualified, wide-input range positive linear voltage regulators designed for military and space flight applications. Packaged in a hermetic tabless TO-257 package, the AP117/117A provides up to 1.5A of output current over the full input voltage range of 2.5V to 40V. The device also features internal thermal shutdown, output current-limiting circuitry and up to ±1% initial output accuracy. The AP117/117A is an excellent choice for applications requiring high radiation tolerance, low noise and high power supply rejection ratios. These voltage regulators are provided in adjustable output voltage configurations only. Consult the factory for fixed output versions. The adjustable version requires only 2 external resistors to program the output from 1.25V to 37V. Absolute Maximum Ratings (Exceeding maximum ratings may damage the device. Symbol Parameter Value Unit Vin- Vo DC input- Output Differential 40 V Io Output Current 1.5 A Pd Power Dissipation Tcase=25oC 50 W 2.5 oC/W Rthjc Thermal Resistance, Junction to Case Tstg Storage Temperature -65 to +150 oC Top Operating Temperature Range -55 to +125 oC 175 oC 5 G 265 oC Parameter Value Unit Minimum in Spec Total Dose Performance (Dose Rate: 50-300 rad(Si)/s) > 300 krads (Si) Minimum in Spec Low Dose Rate Performance (Dose Rate ≤ 10 mRad (Si)/s) > 50 krads (Si) Linear Energy Threshold, Single Event Transients < 100mV, (note 5) > 15 MeV/mg/cm2 Single-Event Latch-up Free linear Energy Transfer Threshold > 87 MeV/mg/cm2 Tj Maximum Junction Temperature W Package weight Tsold Maximum Soldering Temperature, 10sec Radiation Ratings Symbol TID ELDRS SET SEL/SEB Rev Date: 12/19/2014 © API Technologies Corp. Proprietary Information Page # 1 | www.apitech.com | micro.apitech.com | +1.888.553.7531 | [email protected] AP117/AP117A Electrical Characteristics @ Ta= -55oC to +125oC (Unless Otherwise Specified) Pre-Radiation API117A Symbol Parameter Test Conditions API117 Min Typical Max Reference Voltage accuracy 1.238 1.25 1.262 Reference Voltage accuracy (6) 1.225 1.25 1.275 Min Typical Max Units V 1.200 1.250 1.300 V Line Regulation (6) (2) +/-0.02 +/-0.02 %/V Load Regulation (7) (2) +/-1.5 +/- 1.5 % Adjust-Pin Current Vload (6) 100 100 μA Adjust-Pin Current Change (6) -5 5 -5 5 μA Adjust Current Change (7) -5 5 -5 5 μA Output Current (7) 1.25 1.25 A Minimum I/O Differential (4) (7) 3.0 3.0 V Post-Radiation (Ta= 25 oC) Notes (1) (3) API117A Symbol Parameter Test Conditions API117 Min Typical Max Min Reference Voltage accuracy 1.225 1.25 1.270 Reference Voltage accuracy 1.20 1.25 1.3 Adjust-pin current Typical Max Units 1.15 1.35 V 1.15 1.35 V +/-5 μA +/-5 Notes: 1. At the time of publication of this datasheet, API Technologies/Marlborough did not have a DLA certified radiation hardness assurance program. 2. Load & Line regulation are measured at constant (Tj) junction temperature using a low duty cycle pulse. Changes in output voltage due to heating effects must be evaluated separately. 3. TID Radiation Testing is performed per MIL-STD-883, Method 1019. 4. Internal SOA Protection Limits Output Current With High Input Voltage. 5. Vin ≥ 9V and COUT ≥ 44 uF 6. VDIFF ≤ 39V @ 125oC 7. At 125oC, a 1.5A output requires an I/O differential of ≥ 6.75 V. Rev Date: 12/19/2014 © API Technologies Corp. Proprietary Information Page # 2 | www.apitech.com | micro.apitech.com | +1.888.553.7531 | [email protected] AP117/AP117A Package Outline (Tabless TO-257) Pin No Pin Name Pin Description 1 ADJ Adjust Pin 2 OUT Output Voltage 3 IN Input Voltage Case No Connection- Isolated Ordering Information AP117A K D2 Product Number Screening Level 117 = 4% Ref. Accuracy 117A = 1% Ref. Accuracy 117B = 2% Ref. Accuracy K = Class-K Compliant H = Class-H Compliant E = Engineering Model -ADJ Available Output Voltage Options Package Type D2 = Tabless TO-257 7 = TO-257 -ADJ = Adjustable Screening Options Screening Levels K Mil-Std-883Method Sample 100% 2023 EM Tests H CompliantMIL-PRF-38534 Engineering Models 100 % Non-Destruct Wire-Pull N/A Pre-Cap Visual N/A N/A 100% 2017 Temperature Cycle N/A 100% 100% 1010 Constant Acceleration N/A 100% 100% 2001 2020 PIND N/A N/A 100% Pre-Burn-In Electrical (Ta= 25C) N/A 100% 100% Burn-In N/A 100% (160 Hours) 100% (320 Hours) Final Electrical 100% (25C) 100% 100% Hermeticity (Fine & Gross Leak) N/A 100% 100% 1014 X-Ray N/A N/A 100% 2012 External Visual Sample 100% 100% 2009 1015 Rev Date: 12/19/2014 © API Technologies Corp. Proprietary Information Page # 3 | www.apitech.com | micro.apitech.com | +1.888.553.7531 | [email protected] AP117/AP117A Figure 1 – Output Voltage Configuration AP117/AP117A Notes: 1. VOUT = 1.25 (1+ R2/R1) 2. R1 is recommended to be ≤ 125 Ω Figure 2 – Typical Application AP117/AP117A Rev Date: 12/19/2014 © API Technologies Corp. Proprietary Information Page # 4 | www.apitech.com | micro.apitech.com | +1.888.553.7531 | [email protected]