Filtran Limited ISDN S-Bus Input / Output Modules 8485

ISDN S-Bus
Input / Output Modules
8485
Units matched to leading transceiver IC’s. Meets impedance requirements of CCITT
I.430 for both TE and NT over an extended temperature range –40 to + 85°C.
IC MFG.
FILTRAN P/N
SIEMENS
PSB 21381/21382/21383/21384
PEB3086
8485
8485
MECHANICAL AND SCHEMATIC
UNLESS OTHERWISE SPECIFIED, ALL TOLERANCES ARE ±0.015
(All dimensions in inches)
SUGGESTED PAD LAYOUT
SCHEMATIC
1
.900
1.125 Max
.100
8485
.480
.510 Max
YYWWX
.660
20
5
19
2
18
4
Sec:Pri
.090
3
8
.018±.003
13
7
12
9
.030
.100±.010
.900±.010
6
11
Sec:Pri
.610±.015
.300 Max
0°-8°
.004
20 Surfaces
.010±.005
10
.047 Typ
ELECTRICAL SPECIFICATIONS @ 25°C
Transformer
Part
Number
8485
Choke
Ratio ±2%
L Pri
LL Sec
Cw/w
CD Pri
DCR Pri
DCR Sec
(Pri:Sec)
(mH MIN)
(µH MAX)
(pF MAX)
(pF MAX)
(Ω +25% MAX)
(Ω +25% MAX)
1CT:1CT
30
10
150
100
3.4
3.4
Filtran Limited
An ISO 9000 Registered Company
L
4.7 mH
DCR
Secondary
Pins
(Ω MAX)
1.4
20-18, 13-11
360 Terry Fox Drive, Ottawa, ON CANADA K2K 2P5
Tel: (613) 226-1626
Fax: (613) 226-7124
2011/01/03 Details subject to change without notice.