Unregulated DC Power Supplies Open Frame

Unregulated DC Power Supplies Open Frame
Series: BVU
• Low cost unregulated DC power supplies
• Field selectable input taps 103/115/126/207/230/253
VAC for fine-tuning output to match actual field
conditions
• Improved ripple - 3% maximum
• Fuse protected output
• Computer grade capacitors
• Floating output provides versatility for wiring
• Safety Agency Approvals:
– UL 1950, Third Edition, File #E181899
– CSA C22.2 No. 950, UL File #E181899
– CE Marked
The BVU Series
Specifications
The BVU Series of unregulated DC power supplies is the best
low cost alternative, where moderate output variations and
AC ripple are acceptable. The field selectable input taps allow
fine tuning the output voltage to match actual field conditions.
The DC output is fused for short circuit protection. For maximum versatility, the output is floating and may be referenced
to another low voltage common ground or placed in series
with other DC power supplies.
AC Input: 115/230VAC, 50/60Hz nominal.
Field selectable taps for +/–10%. High line tolerance on
voltage is +10%
DC Output: Floating fixed output at full load ratings (see
table). Transformer taps provided for approx. 10% output
voltage adjustment.
Ripple: 3% r.m.s. maximum at nominal line and full rated
load.
Operating Temperature: 0-50°C (Derate 2% per °C to
70°C)
Overload and Short Circuit Protection: Fused output.
It should be noted that the fuse is not necessarily direct in
line with the output. In most models the fuse is prior to the
output capacitor and in case of a short circuit, the capacitor
energy will be discharged into the load even if the fuse has
opened.
Applications
• DC motors - stepping and servos
• Solenoid valves
• Relays
• Lamps and signal systems
• Input to 3-terminal on-board regulators
• Some floppy disc drives
Tap
(VAC)
Nominal
(VAC)
High Line
(VAC)
115,–10%
103.5
113.9
115,NOM
115
126.5
115,+10%
126.5
139.2
230,–10%
207
227.7
230,NOM
230
253.0
230,+10%
253
Schematic shows transformer taps provided for approx.
+/–10% output voltage adjustment. Typical full load output
voltage at 115VAC input using taps 1 and 3. For 10% higher
output voltage use taps 1 and 2. For 10% lower output voltage use taps 1 and 4.
+10%
115 VAC
HOT
278.3
8
NOMINAL 7
-10%
6
INPUT CONNECTIONS FOR BVU SERIES
INPUT
VAC
103.5
115
126.5
1-5
JUMPER
2-6
1-5
3-7
1-5
4-8
207
230
AC NEUTRAL 5
253
+10%
2-5
3-5
4-5
115 VAC
HOT
FUSE
AT
16
1-2
1-3
1-4
1-6
1-7
4
NOMINAL 3
— OUTPUT
-10%
INPUT
APPLY
+ OUTPUT
(TERMINAL AT FUSE)
2
1-8
AC NEUTRAL 1
SEE UNIT ID LABEL
Phone (630) 628-9999 • Fax (630)628-9922 • http://www.powervolt.com