Datasheet PDF

Linear Regulated DC Power Supplies
International Series: BVA
• Single, dual, triple outputs
• Worldwide field selectable
100/117/220/230-240VAC input
• Rated full load at 50°C
• Overload and short circuit protection
• Remote sense compensates for line drop
and assures voltage at the load
• Reverse polarity protection
• Open sense lead protection
• Overvoltage Protection (OVP) standard on 5V main outputs
• Worldwide Safety Agency approvals
- UL 1950, Third Edition, File #E181899
- CSA C22.2 No. 950, UL File #E181899
- CB Scheme, File #MC3535
- CE Marked
• Made in the U.S.A.
• 2 year warranty
The International Series BVA
Value Added Services
PowerVolt offers a wide variety of value added services and
design features to meet your application requirements. The
first and foremost service we offer is our flexibility to design
custom units for your application. Other features include, but
are not limited to, terminal blocks, mounting spacers, fuse
and fuse holders, line cords etc. Please contact your local
factory representative, distributor or factory direct for
quotations.
Specifications
4
Aluminum
Chassis
Heat Sink
Cermet
Trim Pots
Remote Sense
Compensates
Line Drop
Conservative
Transformer
Design
Screw
Terminals
for Easy
Wiring
Input Fuse
Field Selectable Taps 100/117/220/230-240 VAC
Operating Temperature: 0°C to 50°C full rated load,
derate linearly to 40% at 70°C. See derating chart.
Storage Temperature: –55°C to +85°C
Vibration: Per MIL-STD-810B, Method 514, Procedure I,
Curve AB (to 50 Hz)
Shock: Per MIL-STD-810B, Method 516, Procedure V
Safety Standards: • UL 1950, Third Edition • CSA C22.2
No. 950 • CE marked • CB Scheme
Finish: Clear aluminum chassis. Also serves as heat sink.
Mounting: Units can be mounted on several surfaces.
Mounting holes will accept “press fit” #6-32 threaded fasteners. For efficient cooling, allow unrestricted air flow. Forced
air cooling may be recommended.
DERATING CHART
100%
M
CF
IR
100
LA
RA
TU
NA
AC Input: Field selectable taps for 100/117/220/230-240
VAC ±10%; 47-63Hz. See chassis ID lable for jumper and line
fusing requirements. For 50Hz operation derate output by 10%.
DC Output: See selection guide for voltage/current ratings.
The output is floating; either positive or negative terminal can
be grounded. Output adjustment range is ±10%, except variable 10-18V outputs.
Line Regulation: ±0.05% for 10% line change
Load Regulation: ± 0.05% for 50% load change
Thermal Regulation: ±0.02% per °C maximum, ±0.005%
per °C typical
Output Ripple: 2 mV RMS maximum, 3 mV P-P
Dynamic Response: 30 microseconds for 50% load change
Stability: ±0.3% for 24 hour period after 1 hour warm-up
Short Circuit and Overload Protection: Foldback current
limiting, set at 120% of nominal
Overvoltage Protection: Crowbar overvoltage protection is
standard on all 5VDC main outputs and is factory set at
6.2V±0.4V (fixed). Optional universal OVP module adjustable
from 4.5 to 36V is available for other models.
Remote Sensing: Standard on all outputs above 30 watts.
Remote sense will compensate for a cable drop of 0.25V.
Protected against open or shorted sense leads. Twisted pair
sense leads are recommended.
Efficiency: 5V units: 45%; 12 and 15V units: 55%; 24V and
higher units: 60%.
High
Reliability
Capacitors
OVP
Module
PERCENT OF RATED OUTPUT
The BVA series is the premium grade, open frame line of linear DC power supplies. Designed to operate over a wide
range of AC power sources found worldwide, the BVA series
is especially suited for OEM applications where cost is a significant factor. The field selectable universal input
(100/117/220/230-240VAC) reduces your inventory cost by
allowing to use just one standard model regardless of
destination.
80%
60%
40%
Natural air
100% 70% 40%
convection
Forced air (100 CFM) 100% 100% 70%
10
20
30
40
50
60
AMBIENT TEMPERATURE
Phone (630) 628-9999 • Fax (630)628-9922 • http://www.powervolt.com