4 - IEC Control, Load and Disconnect Switches

Bulletin 194R
IEC Fused and Non-Fused Disconnects
4
Bulletin 194R
• 20 A…400 A Sizes
• Open or Enclosed Switches
• Fused Switch Versions:
• BS88
• DIN
• CSA HRCII-C
• CSA HRCI-J
• UL Class J
• UL Class CC
• Non-Fused Switches
• Operating Handle Ingress
Ratings:
• IP42 (Type 1)
• IP66 (Type 3R, 3, 12, 4, 4X)
• Handle with or without
Defeater Mechanism
• Padlockable Handle with up
to Three Padlocks
• Up to 8 Auxiliary Contacts
can be Added Per Switch
• Suitable as Service Entrance
Disconnecting Means
TABLE OF CONTENTS
Description
Page
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disconnect Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Shafts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disconnect Switch Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Enclosed Disconnect Switches. . . . . . . . . . . . . . . . . . . . . . . . .
4-64
4-64
4-66
4-67
4-68
4-69
Description
Page
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-69
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-72
Proper Selection of Disconnect Switches . . . . . . . . . . . . . . . . 4-79
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-80
Fuse Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-81
Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-85
A-B EXPRESS
Fast Shipment Program
Description
The Bulletin 194R line of fused and non-fused IEC disconnect switches provides the
flexibility to meet worldwide applications. These rod operated disconnect switches
incorporate on-board fuse carriers thus reducing panel space requirements and have
high short circuit protection ratings. The disconnect switches are UL Listed, CSA,
ASTA and LOVAG Certified and are designed to meet IEC 947-3, VDE, DIN, BS and
applicable NEMA requirements.
Conformity to Standards:
Approvals:
IEC 947-3/EN60947-3
BS EN60947-3
VDE 0660
CSA 22.2 No. 4
NEMA KS-1
UL 1087/489
UL 98
ASTA Certified
LOVAG Certified
CE (IEC 947-3)
CSA Certified (File No. LR 1234)
UL Listed (File No. E 119349/E 14840)
Bulletin 198 Rotary Circuit Breaker Operating Mechanism — See Page 4-102
• Fast Shipment of Bulletin 194R
Products to satisfy your unexpected
demands
• Make your selection from any of the Cat.
Nos. listed in blue and mark your order
as
Your order must include:
• The desired disconnect switch Cat. No.
Note the disconnect switch dimension
reference.
• The appropriate operating handle
and operating shaft Cat. No.
corresponding to the dimension
reference of the disconnect switch.
• The desired accessories Cat. No. (if
required) for the application,
corresponding to the dimension
reference of the disconnect switch.
4-63
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Product Selection
BS88 Fused Disconnect Switches
Ratings (AC23)
With Fuse Links
Load
Rating
Ie
(A)
With Shorting Links
3∅ Maximum kW (50 Hz)
200/
230V
380/
400/
415V
20 ➊
3
7.5
7.5
—
32
7.5
15
18.5
11
60
11
30
30
75
22
37
138
37
245
300
Load
Rating
Ie
(A)
3∅ Maximum kW (50 Hz)
Dim.
Ref.
Cat. No.
BS88 A1
A1
194R-NA100P3
BS88 A2
A1
194R-NA200P3
BS88 A3
B1
194R-NA300P3
55
BS88 A3
C1
194R-NA380P3
90
110
BS88 A4
D1
194R-NA400P3
132
160
160
BS88 B1, B2
E1
194R-NB200P3
160
200
200
BS88 B1, B2 B3, B4
F1
194R-NB300P3
200/
230V
380/
400/
415V
500V
660/
690V
32
7.5
15
18.5
11
—
—
—
—
—
30
63
11
30
30
30
45
55
75
22
37
45
75
90
110
138
37
75
75
132
160
160
245
75
90
160
200
200
300
40
500V
660/
690V
Fuse
Type
DIN Fused Disconnect Switches
Ratings (AC23)
With Fuse Links
Load Rating
Ie
(A)
3∅ Maximum kW (50 Hz)
200/
230V
380/
400/
415V
500V
660/
690V
Fuse
Type
Dim.
Ref.
Cat. No.
75
22
37
45
55
DIN 00
C2
194R-ND072P3
138
37
75
90
110
DIN 0, 00 ➋
D2
194R-ND138P3
245
75
132
160
160
DIN 1
E2
194R-ND250P3
300
90
160
200
200
DIN 1, 2
F1
194R-ND300P3
➊ Maximum ampere rating is 32 A if shorting links, Cat. No. 194R-SLA1, is used. See page 4-71.
➋ Series C only.
Accessories — Page 4-69
Specifications — Page 4-72
Approximate Dimensions — Page 4-85
4-64
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Product Selection, Continued
UL/CSA Fused Disconnect Switches
Fast Shipment Program Cat. Nos. are printed in blue.
Cat. No. 194R-NA300P3
Cat. No. 194R-NJ100P3
Cat. No. 194R-NC030P3
Maximum HP Ratings ➊
Ampere
Rating
(A)
115V
230V
200V
230V
460V
30
2
3
7-1/2
7-1/2
15
20
—
—
60
3
10
15
15
30
30
—
—
100
—
15
25
30
60
75
—
—
200
—
30
50
60
125
150
—
400
—
50
100
125
250
300
—
1∅ (60 Hz)
3∅ (60 Hz)
Fuse
Type
Dim.
Ref.
Cat. No.
30 A HRCII-C
A1
194R-NA200P3
60 A HRCII-C
B1
194R-NA300P3
100 A HRCII-C
D1
194R-NH100P3
—
200 A HRCII-C
E1
194R-NH200P3
—
400 A HRCII-C
F1
194R-NH400P3
DC
575V
125V
250V
CSA HRCII-C FUSES
UL CLASS CC & J AND CSA HRCI-J FUSES ➋
30
3/4
2
5
5
10
10
2
3
30 A CLASS CC
A1
194R-NC030P3
30
2
3
7-1/2
7-1/2
15
20
3
5
30 A CLASS J
A1
194R-NJ030P3
60
3
10
15
15
30
50
5
10
60 A CLASS J
B1
194R-NJ060P3
100
7-1/2
15
25
30
60
75
—
20
100 A CLASS J
C1
194R-NJ100P3 ➍
200
—
25
50
60
125
150
—
40
200 A CLASS J
D1
194R-NJ200P3
400
—
50
100
125
250
300
—
50
400 A CLASS J
F1
194R-NJ400P3
Dim.
Ref.
Cat. No.
194R-NN030P3
UL/CSA Non-Fused Disconnect Switches
Non-Fused
Fuse
Description
➌
➊
➋
➌
➍
Ampere
Rating
(A)
Maximum HP Ratings
1∅ (60 Hz)
115V
3∅ (60 Hz)
DC
230V
200V
230V
460V
575V
125V
250V
30
2
3
7-1/2
7-1/2
15
20
3
5
A2
60
3
10
15
15
30
50
5
10
B2
194R-NN060P3
100
7-1/2
15
25
30
60
75
—
20
C1
194R-NN100P3 ➍
200
—
25
50
60
125
150
—
40
D1
194R-NN200P3
400
—
—
100
125
250
300
—
50
F1
194R-NN400P3
Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower rating.
Only CSA Certified HRCI-J and UL Listed Class J and CC fuses are suitable for use with these disconnect switches.
Non-fused disconnect switches must use separately installed CSA Certified HRCI-J fuses or UL Listed Class J, CC or T fuses.
Line and Load Terminals use 4 mm Allen-type wrench; will not accept terminal lugs.
Accessories — Page 4-69
Specifications — Page 4-72
Approximate Dimensions — Page 4-85
4-65
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Product Selection, Continued
Operating Handles
Fast Shipment Program Cat. Nos. are printed in blue.
Disconnect
Switch
Dim. Ref.
Description
Color
Degree of Protection
Cat. No.
IP42 (Type 1)
194R-HS1
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HS4
IP42 (Type 1)
194R-HS1E
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HS4E
IP42 (Type 1)
194R-HS1-N2
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HS4-N2
IP42 (Type 1)
194R-HS1E-N2
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HS4E-N2
IP42 (Type 1)
194R-HM1
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HM4
IP42 (Type 1)
194R-HM1E
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HM4E
IP42 (Type 1)
194R-HM1-N2
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HM4-N2
IP42 (Type 1)
194R-HM1E-N2
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HM4E-N2
IP42 (Type 1)
194R-HM1-N1
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HM4-N1
IP42 (Type 1)
194R-HM1E-N1
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HM4E-N1
IP42 (Type 1)
194R-HM1-N3
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HM4-N3
IP42 (Type 1)
194R-HM1E-N3
IP66 (Type 3R, 3, 12, 4, 4X)
194R-HM4E-N3
Black
With Defeater
Red/Yellow
A1, A2
B1, B2
Black
Without Defeater
Red/Yellow
Black
Standard
Orientation
With Defeater
Red/Yellow
Black
Standard
Orientation
Without Defeater
Red/Yellow
C1, C2
D1, D2
E1, E2
F1
Black
90° Rotated
Orientation
With Defeater
Red/Yellow
Black
90° Rotated
Orientation
Without Defeater
Red/Yellow
Accessories — Page 4-69
Specifications — Page 4-72
Approximate Dimensions — Page 4-85
4-66
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Product Selection, Continued
Operating Shafts
Disconnect
Switch
Dim. Ref.
A1, A2
B1, B2
C1, C2
D1, D2
E1, E2
F1
A1, A2
B1, B2
Description
Operating
Shaft
Length
Approx. Dim.
mm (in.)
Standard
Length
263
(10.3)
Extended
Length
457
(18.0)
Standard
Length
Extended
Length
Standard
Length
Extended
Length
200
(7.9)
403
(15.9)
278
(10.9)
532
(20.9)
Standard
Length
for Medium
Handle
263
(10.3)
Extended
Length
for Medium
Handle
457
(18.0)
Enclosure Working Depth
Disconnect
Switch
Dim. Ref.
Minimum
Approx. Dim.
mm (in.)
Maximum
Approx. Dim.
mm (in.)
Cat. No.
A1, B1
148 (5.8)
260 (10.2)
A2, B2
111 (4.4)
260 (10.2)
A1, B1
148 (5.8)
454 (17.8)
A2, B2
111 (4.4)
454 (17.8)
183 (7.2)
254 (10.0)
194R-R3
183 (7.2)
457 (18.0)
194R-R4
243 (9.6)
356 (14.0)
194R-R5
243 (9.6)
610 (24.0)
194R-R6
148
(5.8)
111
(4.4)
148
(5.8)
111
(4.4)
260
(10.2)
260
(10.2)
454
(17.8)
454
(17.8)
C1, C2
D1, D2
194R-R1
194R-R2
E1, E2, F1
A1, B1
A2, B2
A1, B1
A2, B2
194R-R1M ➊
194R-R2M ➊
➊ Use with 194R HM*** Handle and 194R 30 A or 60 A switch.
Accessories — Page 4-69
Specifications — Page 4-72
Approximate Dimensions — Page 4-85
4-67
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Product Selection, Continued
Complete UL/CSA Disconnect Switch Kits
Fast Shipment Program Cat. Nos. are
printed in blue.
• Includes Disconnect Switch, Operating Handle and Operating Shaft
Load
Rating
(A)
30
Maximum Horsepower Ratings ➊
3∅ (60 Hz)
Disconnect Switch ➋
200V
230V
460V
575V
Fuse
Carrier
Dim.
Ref.
7.5
7.5
15
20
Non-Fused
A2
7.5
7.5
15
20
30 A Class J
A1
5
5
10
10
30 A Class CC
A1
15
15
30
50
Non-Fused
B2
15
15
30
50
60 A Class J
B1
25
30
60
75
Non-Fused
C1
25
30
60
75
100 A Class J
C1
50
60
125
150
Non-Fused
D1
50
60
125
150
200 A Class J
D1
100
125
250
300
Non-Fused
F1
100
125
250
300
400 A Class J
F1
Operating
Shaft
Type
Operating Handle
Degree
of Ingress
Protection
60
100
200
400
Standard
Length
IP66
(Type 3R, 3,
12, 4, 4X)
Cat. No.
Color
Black
194R-NN030P34R1
Red/Yellow
194R-NN030P34ER1
Black
194R-NJ030P34R1
Red/Yellow
194R-NJ030P34ER1
Black
194R-NC030P34R1
Red/Yellow
194R-NC030P34ER1
Black
194R-NN060P34R1
Red/Yellow
194R-NN060P34ER1
Black
194R-NJ060P34R1
Red/Yellow
194R-NJ060P34ER1
Black
194R-NN100P34R3
Red/Yellow
194R-NN100P34ER3
Black
194R-NJ100P34R3
Red/Yellow
194R-NJ100P34ER3
Black
194R-NN200P34R3
Red/Yellow
194R-NN200P34ER3
Black
194R-NJ200P34R3
Red/Yellow
194R-NJ200P34ER3
Black
194R-NN400P34R5
Red/Yellow
194R-NN400P34ER5
Black
194R-NJ400P34R5
Red/Yellow
194R-NJ400P34ER5
➊ Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower ratings.
➋ Only UL Listed Class J and CC, and CSA Certified HRCI-J fuses are suitable for use with these disconnect switches.
Accessories — Page 4-69
Specifications — Page 4-72
Approximate Dimensions — Page 4-85
4-68
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Product Selection, Continued/Accessories
UL Enclosed Disconnect Switches (Fused and Non-Fused)
Fast Shipment Program Cat.
Nos. are printed in blue.
Stainless Steel Enclosure
Maximum Horsepower Ratings
Ampere
Rating
(A)
1∅ (60Hz)
3∅ (60Hz)
115V
230V
200V
230V
460V
575V
3/4
2
5
5
10
10
2
3
7-1/2
7-1/2
15
20
60
3
10
15
15
30
50
100
7-1/2
15
25
30
60
75
200
—
25
50
60
125
150
400
—
50
100
125
250
300
30
IP66
(Type 4/4X)
Watertight,
Corrosion-Resistant
Stainless
Steel Enclosure
IP66
(Type 4/4X)
Watertight,
Corrosion-Resistant
Non-Metallic
Enclosure
Fuse
Description
Dim.
Ref.
IP66
(Type 3/4/12)
Watertight Dusttight
Sheet Metal Enclosure
Cat. No. ➊
Cat. No. ➊
Cat. No. ➊
Class CC Fused
A1
194R-FC030P3
194R-CC030P3
194R-KC030P3
Class J Fused
A1
194R-FJ030P3
194R-CJ030P3
194R-KJ030P3
Non-Fused
A2
194R-FN030P3
194R-CN030P3
194R-KN030P3
Class J Fused
B1
194R-FJ060P3
194R-CJ060P3
194R-KJ060P3
Non-Fused
B2
194R-FN060P3
194R-CN060P3
194R-KN060P3
Class J Fused
C1
194R-FJ100P3
194R-CJ100P3
194R-KJ100P3
Non-Fused
C1
194R-FN100P3
194R-CN100P3
194R-KN100P3
Class J Fused
D1
194R-FJ200P3
194R-CJ200P3
194R-KJ200P3
Non-Fused
D1
194R-FN200P3
194R-CN200P3
194R-KN200P3
Class J Fused
F1
194R-FJ400P3
194R-CJ400P3
194R-KJ400P3
Non-Fused
F1
194R-FN400P3
194R-CN400P3
194R-KN400P3
➊ Black operating handles supplied as standard. To order Red/Yellow Handles, add string suffix “E” to the Cat. No. Example: Cat. No.
194R-FC030P3E.
Operating Shaft Guide
Disconnect
Switch Dim Ref.
Pkg.
Qty.
Cat. No.
A1, A2, B1, B2
1
194R-HSG1
Disconnect
Switch Dim Ref.
Pkg.
Qty.
Cat. No.
A1, A2, B1, B2
1
194R-R1G
C1, C2, D1, D2
1
194R-R3G
Shaft Guard
Specifications — Page 4-72
Approximate Dimensions — Page 4-85
4-69
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Accessories, Continued
Operating Shaft Coupler
Disconnect
Switch Dim Ref.
Pkg. Qty.
Cat. No.
A1, A2, B1, B2
1
194R-SC1
Operating Handle Instruction Label
Disconnect
Switch Dim Ref.
Conductor Range
Pkg. Qty.
Cat. No.
ALL
—
10
194R-L1
Fuse Covers
CSA/UL 30/60 A non-fused switches come with fuse covers as standard.
Disconnect
Switch Dim. Ref.
A1, A2
B1, B2
Quantity
Required Per
Disconnect Switch
194R-FCA2
1
194R-FCJ60
194R-FCC1
C1
C2
D1, D2
Cat. No. 194R-FCA2
Cat. No. 194R-FCD1
Cat. No.
194R-FCC2
3
194R-FCD1
E1, E2
194R-FCE1
F1
194R-FCF1
Terminal Shields ➊
CSA/UL switches come with line side shield as standard.
Disconnect
Switch Dim. Ref.
Quantity Required Per
Disconnect Switch
Cat. No.
A1, A2
194R-LNC1
B1, B2
194R-LNC2
C1, C2
D1, D2
194R-LNC3
2
194R-LNC4
E1, E2
194R-LNC5
F1
194R-LNC6
Terminal Lugs
Disconnect
Switch Dim Ref.
Conductor Range
Pkg.
Qty.
D1
(Cat. No.
194R-NH100P3 only)
10 mm 2…50 mm2
#8…1/0 AWG
D1
(Cat. No.
194R-NJ200P3, NN200P3,
NA400P3)
D2
16 mm 2…120 mm2
#6…250MCM AWG
E1, E2
25 mm 2…240 mm2
#4…500MCM AWG
199-LG1
F1
Two 50 mm2…150 m2
Two 1/0…350MCM AWG
199-LH1
Cat. No.
199-LE1
3
199-LF1
➊ For use on either Line or Load Side of Disconnect Switch. Disconnect switch Cat. Nos: 194R-NN**P3, 194R-NJ**P3 and 194R-NC**P3 are
provided as standard with a line side terminal shield.
Product Selection — Page 4-64
4-70
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Accessories, Continued
Auxiliary Contacts ➊
Disconnect Switch
Dim. Ref.
Description
Contact
Configuration
Cat. No.
A1, A2
B1, B2
Auxiliary Contact
Adapter
—
194R-AA
1 N.O.
195-GA10
ALL ➋
Single Pole ➌
1 N.C.
195-GA01
1 N.O.…1 N.C.
195-GA11
2 N.O.
195-GA20
2 N.C.
195-GA02
—
194R-A1
Cat. No. 194R-AA
Cat. No. 195-GA10
ALL ➋
Two Pole ➌
Auxiliary Support
For 5…8 Circuits Per
Switch
ALL
Shorting Links For BS Switches Only
Disconnect
Switch
Dim. Ref.
Description
A1
BS88 Size A1
B1
C1
BS88 Size A3
For Use with
Cat. No.
Cat. No.
194R-NA100P3
194R-SLA1
194R-NA300P3
194R-NA380P3
D1
BS88 Size A4
194R-NA400P3
E1
BS88 Size B1, B2
194R-NB200P3
F1
BS88 Size B3, B4
194R-NB300P3
194R-SLA3
194R-SLA4
194R-SLB2
Disconnect Switch Padlocking Kit
Disconnect
Switch Dim Ref.
Pkg. Qty.
Cat. No.
A1, A2
B1, B2
1
194R-P1
➊ See page 4-78 for contact ratings.
➋ Disconnect switches with dimension reference A1, A2, B1 and B2 require a quantity of one (1) auxiliary contact adapter, Cat. No. 194R-AA, for
installation of auxiliary contacts.
➌ A maximum of four (4) contact blocks (8 auxiliary contacts) can be installed on each disconnect switch. When more than two (2) contact blocks
are used, a support kit Cat. No. 194R-A1 must be used.
Product Selection — Page 4-64
4-71
Bulletin 194R
IEC Fused and Non-Fused Disconnects
4
Specifications
Fused Disconnect Switches For BS88 Fuses
Note: Table continued on page 4-73.
Electrical Ratings
194R-NA100P3
194R-NA200P3
BS88 Dimension
A1
A2
A3
(V)
660
660
660
80
80
80
Cat. No.
Fuse Type
Rated Insulation Voltage (Ui)
Maximum Short Circuit Prospective
Fault Current
(kA)
194R-NA300P3
Fuse
Links
Shorting
Links
Fuse
Links
Fuse
Links
Shorting
Links
(A)
(A)
(A)
(A)
20
20
20
—
32
32
32
32
32
32
32
32
63
63
63
63
63
63
63
63
Rated Operational Current AC-23A (le)
200/230V 50 Hz
380/400/415V 50 Hz
500V 50 Hz
660/690V 50 Hz
(A)
(A)
(A)
(A)
20
20
20
—
32
32
32
18
32
32
32
18
45
60
45
37
45
63
45
37
Rated Thermal Current (lthe)
(A)
20
32
32
63
63
(kW)
(kW)
(kW)
(kW)
3
7.5
7.5
—
7.5
15
18.5
11
7.5
15
18.5
11
11
30
30
30
11
30
30
30
Rated Operational Current AC-22A (le)
200/230V 50 Hz
380/400/415V 50 Hz
500V 50 Hz
660/690V 50 Hz
Maximum kW, AC-23A 3∅
200/230V 50 Hz
380/400/415V 50 Hz
500V 50 Hz
660/690V 50 Hz
(A)
Maximum Fuse Rating
Maximum Motor Circuit Fuse Link
Maximum Fuse Cut-off Current ➊
(kA)
Rated Short Time Current, 1 Second
(kA)
20
—
32
63
—
20M32
—
32M63
63M100
—
7.5
7.5
10
7.5
1
10
1
1
194R-NA100P3
194R-NA200P3
194R-NA300P3
IP 00
IP 20
IP 00
IP 20
IP 00
IP 20
Operations
10,000
10,000
10,000
Nm
Lb.-In.
4
35
4
35
4
35
mm2
AWG
2.5…6
#14…#8
2.5…6
#14…#8
2.5…25
#14…#4
mm2
AWG
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
8
8
8
kg
Lbs.
0.83
1.84
0.83
1.84
1.18
2.60
248 (9-3/4)
171 (6-3/4)
148 (5-13/16)
248 (9-3/4)
171 (6-3/4)
148 (5-13/16)
248 (9-3/4)
197 (7-3/4)
148 (5-13/16)
A1
A1
B1
Mechanical Data
Cat. No.
Degree of Protection (per IEC 947)
Switch Only
Switch with Terminal Shield
& Fuse Cover(s)
Mechanical Endurance ➋
Operating Torque (Maximum)
Terminal Capacity
Power Terminals
Auxiliary Contact Terminals
Maximum Number of Auxiliary Circuits
Approximate Weight
Height
Minimum Enclosure Size
Approximate dimensions in millimeters (inches) Width
Depth
Switch Dimension Reference
(See dimension drawings on pages 4-87 and 4-88.)
➊ Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when
subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded.
➋ Based on Allen-Bradley tests in accordance with the requirements as defined in IEC 947-3.
Product Selection — Page 4-64
4-72
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Specifications, Continued
Fused Disconnect Switches For BS88 Fuses, Continued
Electrical Ratings
194R-NA380P3
194R-NA400P3
194R-NB200P3
194R-NB300P3
BS88 Dimension
A3
A4
B1, B2
B1, B2, B3, B4
(V)
660
660
660
660
80
80
80
Cat. No.
Fuse Type
Rated Insulation Voltage (Ui)
Maximum Short Circuit Prospective
Fault Current
(kA)
Shorting
Links
Fuse
Links
Shorting
Links
Fuse
Links
Shorting
Links
Fuse
Links
Shorting
Links
(A)
(A)
(A)
(A)
100
100
100
100
100
100
100
100
200
200
200
200
160
160
160
160
250
250
250
250
250
250
250
250
400
400
400
400
400
400
400
400
(A)
(A)
(A)
(A)
75
75
65
61
75
75
65
61
130
138
130
118
130
138
130
118
240
245
220
170
240
245
220
170
300
300
290
220
300
300
290
220
(A)
100
100
160
160
200
250
400
400
22
37
45
55
22
37
45
55
37
75
90
110
37
75
90
110
75
132
160
160
75
132
160
160
90
160
200
200
90
160
200
200
—
Rated Operational Current AC-22A (le)
200/230V 50 Hz
380/400/415V 50 Hz
500V 50 Hz
660/690V 50 Hz
80
Fuse
Links
Rated Operational Current AC-23A (le)
200/230V 50 Hz
380/400/415V 50 Hz
500V 50 Hz
660/690V 50 Hz
Rated Thermal Current (lthe)
Maximum kW, AC-23A 3∅
200/230V 50 Hz
380/400/415V 50 Hz
500V 50 Hz
660/690V 50 Hz
(kW)
(kW)
(kW)
(kW)
(A)
Maximum Fuse Rating
Maximum Motor Circuit Fuse Link
Maximum Fuse Cut-off Current ➊
(kA)
Rated Short Time Current, 1 Second
(kA)
100
—
200
—
200
—
400
100M125
—
200M250
—
ED355
—
400M450
—
14
14
20
20
33
33
40
40
2
4
7.5
12
194R-NA380P3
194R-NA400P3
194R-NB200P3
194R-NB300P3
IP 00
IP 20
IP 00
IP 20
IP 00
IP 20
IP 00
IP 20
Mechanical Data
Cat. No.
Degree of Protection (per IEC 947)
Switch Only
Switch with Terminal Shield
& Fuse Cover(s)
Mechanical Endurance ➋
Operating Torque (Maximum)
Terminal Capacity
Power Terminals
Auxiliary Contact Terminals
Operations
10,000
8,000
8,000
8,000
Nm
Lb.-In.
17.5
155
20.3
180
31.4
275
31.4
275
mm2
AWG
2.5…35
#14…#2
16…120
#6-250MCM
25…240
#4-500MCM
Two 50…150
Two 1/0…350MCM
mm2
AWG
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
8
8
8
8
kg
Lbs.
4.03
8.88
6.16
13.59
9.30
20.50
23.83
30.50
330 (13)
301 (11-27/32)
162 (6-3/8)
560 (22)
344 (13-17/32)
178 (7)
610 (24)
394 (15-33/64)
227 (8-15/16)
762 (30)
424 (16-45/64)
243 (9-9/16)
C1
D1
E1
F1
Maximum Number of Auxiliary Circuits
Approximate Weight
Height
Minimum Enclosure Size
Approximate dimensions in millimeters (inches) Width
Depth
Switch Dimension Reference
(See dimension drawings on pages 4-89 and 4-90.)
➊ Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when
subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded.
➋ Based on Allen-Bradley tests in accordance with the requirements as defined in IEC 947-3.
Product Selection — Page 4-64
4-73
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Specifications, Continued
Fused Disconnect Switches For DIN Fuses
Electrical Ratings
194R-ND072P3
194R-ND138P3
194R-ND250P3
DIN Dimension
00
0
1
1, 2
(V)
660
660
660
660
100
100
100
100
Fuse
Links
Fuse
Links
Fuse
Links
Fuse
Links
Cat. No.
Fuse Type
Rated Insulation Voltage (Ui)
Maximum Short Circuit Prospective
Fault Current
(kA)
Rated Operational Current AC-22A (le)
194R-ND300P3
200/230V 50 Hz
380/400/415V 50 Hz
500V 50 Hz
660/690V 50 Hz
(A)
(A)
(A)
(A)
85
85
85
85
160
160
160
160
250
250
250
250
400
400
400
400
Rated Operational Current AC-23A (le)
200/230V 50 Hz
380/400/415V 50 Hz
500V 50 Hz
660/690V 50 Hz
(A)
(A)
(A)
(A)
75
72
65
61
130
138
130
118
240
245
220
170
300
300
290
220
Rated Thermal Current (lthe)
(A)
85
160
250
400
(kW)
(kW)
(kW)
(kW)
22
37
45
55
37
75
90
110
75
132
160
160
90
160
200
200
Maximum kW, AC-23A 3∅
200/230V 50 Hz
380/400/415V 50 Hz
500V 50 Hz
660/690V 50 Hz
(A)
Maximum Fuse Rating
Maximum Motor Circuit Fuse Link
100
200
250
400
100
200
250
400
Maximum Fuse Cut-off Current ➊
(kA)
14
20
33
40
Rated Short Time Current, 1 Second
(kA)
2
4
7.5
12
Mechanical Data
Cat. No.
Degree of Protection (per IEC 947)
Switch Only
Switch with Terminal Shields
& Fuse Cover(s)
Mechanical Endurance ➋
Operating Torque (Maximum)
Terminal Capacity
Power Terminals
Auxiliary Contact Terminals
Operations
Nm
Lb.-In.
mm2
AWG
mm2
AWG
Maximum Number of Auxiliary Circuits
Approximate Weight
Minimum Enclosure Size
Approximate dimensions in
millimeters (inches)
kg.
Lbs.
Height
Width
Depth
Switch Dimension Reference
(See dimension drawings on pages 4-89 and
4-90.)
194R-ND072P3
194R-ND138P3
194R-ND250P3
194R-ND300P3
IP 00
IP 20
IP 00
IP 20
IP 00
IP 20
IP 00
IP 20
10,000
8,000
8,000
8,000
17.5
155
20.3
180
31.4
275
31.4
275
2.5…35
#14…#2
16…120
#6…250MCM
25…240
#4…500MCM
Two 50…150
Two 1/0…350MCM
2.5… 4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
8
8
8
8
4.15
9.16
6.17
13.61
9.41
20.75
14.06
31.00
330 (13)
301 (11-27/32)
168 (6-5/8)
560 (22)
344 (13-17/32)
183 (7-7/32)
712 (28)
394 (15-33/64)
227 (8-15/16)
762 (30)
424 (16-45/64)
243 (9-9/16)
C2
D2
E2
F1
➊ Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when
subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded.
➋ Based on Allen-Bradley tests in accordance with the requirements as defined in IEC 947-3.
Product Selection — Page 4-64
4-74
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Specifications, Continued
Fused Disconnect Switches For CSA HRCII-C Fuses
Electrical Ratings
Cat. No.
194R-NA200P3
194R-NA300P3
194R-NH100P3
194R-NH200P3
194R-NH400P3
HRCII-C
HRCII-C
HRCII-C
HRCII-C
HRCII-C
(A)
30
60
100
200
400
(V)
600
600
600
600
600
(A)
30
60
100
200
400
Maximum Short Circuit Prospective
(kA)
Fault Current
100
100
100
100
100
CSA Fuse Type
Maximum Fuse Cartridge Size
AC
Maximum Voltage
Ampere Rating
Maximum HP, 3∅ AC
200V 60 Hz
230V 60 Hz
460V 60 Hz
575V 60 Hz
(HP)
(HP)
(HP)
(HP)
7.5
7.5
15
20
15
15
30
50
25
30
60
75
50
60
125
150
100
125
250
300
115V 60 Hz
230V 60 Hz
(HP)
(HP)
2
3
3
10
—
15
—
30
—
50
Maximum HP, 1∅ AC
Mechanical Data
Cat. No.
Degree of Protection (per IEC 947)
Switch Only
Switch with Terminal Shields &
Fuse Cover(s)
Mechanical Endurance ➊
Operating Torque (Maximum)
Terminal Capacity
Power Terminals
Auxiliary Contact Terminals
Operations
Minimum Enclosure Size
Approximate dimensions in
millimeters (inches)
194R-NA300P3
194R-NH100P3
194R-NH200P3
194R-NH400P3
IP 00
IP 20
IP 00
IP 20
IP 00
IP 20
IP 00
IP 20
IP 00
IP 20
10,000
10,000
10,000
8,000
8,000
Nm
Lb.-In.
4
35
4
35
20.3
180
31.4
275
31.4
275
mm2
AWG
2.5…6
#14…#8
2.5…25
#14…#4
10…50
#8…#1/0
25…240
#4…500MCM
Two 50…150
Two 1/0…350MCM
mm2
AWG
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
Maximum Number of Auxiliary Circuits
Approximate Weight
194R-NA200P3
kg.
Lbs.
Height
Width
Depth
Switch Dimension Reference
(See dimension drawings on pages 4-87,
4-88, 4-89 and 4-90.)
8
8
8
8
8
0.83
1.84
1.18
2.60
6.16
13.59
9.30
20.50
13.83
30.50
248 (9-3/4)
171 (6-3/4)
148 (5-13/16)
248 (9-3/4)
197 (7-3/4)
148 (5-13/16)
384 (15-1/8)
344 (13-17/32)
178 (7)
610 (24)
394 (15-33/64)
227 (8-15/16)
762 (30)
424 (16-45/64)
243 (9-9/16)
A1
B1
D1
E1
F1
➊ Based on Allen-Bradley tests in accordance with the requirements as defined in CSA C22.2 No. 4 and IEC 947-3.
Product Selection — Page 4-64
4-75
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Specifications, Continued
Fused Disconnect Switches For CSA HRCI-J and UL Class Fuses ➊
Electrical Ratings
Cat. No.
CSA Fuse Type/UL Fuse Type
Maximum Fuse Cartridge Size (A)
AC (V)
Maximum Voltage
DC (V)
(A)
Ampere Rating
Maximum Short Circuit
(kA)
Prospective Fault Current
Fuse Operating Characteristics
Maximum HP, 3∅ AC
200V 60 Hz (HP)
230V 60 Hz (HP)
460V 60 Hz (HP)
575V 60 Hz (HP)
Maximum HP, 1∅ AC
115V 60 Hz (HP)
230V 60 Hz (HP)
Maximum HP, DC
125V DC (HP)
250V DC (HP)
194R-NC030P3
194R-NJ030P3
194R-NJ060P3
HRCI-MISC ➋/
Class CC
30
600
250
30
HRCI-J/
Class J
30
600
250
30
HRCI-J/
Class J
60
600
250
60
194R-NJ100P3 194R-NJ200P3 194R-NJ400P3
HRCI-J/
Class J
100
600
250
100
HRCI-J/
Class J
200
600
250
200
HRCI-J/
Class J
400
600
250
400
100
100
100
100
100
100
Time
Delay
NonTime
Delay
Time
Delay
NonTime
Delay
Time
Delay
NonTime
Delay
Time
Delay
NonTime
Delay
Time
Delay
NonTime
Delay
Time
Delay
NonTime
Delay
5
5
10
10
3
3
5
7.5
7.5
7.5
15
20
3
3
5
7.5
15
15
30
50
7.5
7.5
15
15
25
30
60
75
15
15
25
30
50
60
125
150
25
25
50
60
100
125
250
300
50
50
100
125
0.75
2
0.5
1.5
2
3
0.5
1.5
3
10
1.5
3
7.5
15
—
7.5
—
25
—
15
—
50
—
25
2
3
2
3
3
5
2
5
5
10
5
10
—
20
—
20
—
40
—
40
—
50
—
50
Mechanical Data
Cat. No.
Degree of Protection (per IEC 947)
Switch Only
Switch with Terminal Shields
& Fuse Cover(s)
Operations
Mechanical Endurance ➌
Operating Torque (Maximum)
Nm
Lb.-In.
Terminal Capacity
Power Terminals
mm2
AWG
mm2
AWG
Maximum Number of Auxiliary
Circuits
kg.
Approximate Weight
Lbs.
Minimum Enclosure Size
Approximate dimensions in
Height
millimeters (inches)
Width
Depth
Switch Dimension Reference
(See dimension drawings on pages 4-87,
4-88, 4-89 and 4-90.)
Auxiliary Contact Terminals
194R-NC030P3,
194R-NJ030P3
194R-NJ060P3
194R-NJ100P3
194R-NJ200P3
194R-NJ400P3
IP00
IP20
IP00
IP20
IP00
IP20
IP00
IP20
IP00
IP20
10,000
10,000
10,000
8,000
8,000
4
35
4
35
17.5
155
20.3
180
31.4
275
2.5…6
#14…#8
2.5…25
#14…#4
2.5…35
#14…#2
16…120
#6…250MCM
Two 50…150
Two 1/0…350MCM
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
8
8
8
8
8
0.92
2.03
1.32
2.9
4.12
9.08
6.16
13.59
13.83
30.50
248 (9-3/4)
171 (6-3/4)
148 (5-13/16)
248 (9-3/4)
197 (7-3/4)
148 (5-13/16)
330 (13)
301 (11-27/32)
162 (6-3/8)
560 (22)
344 (13-17/32)
178 (7)
762 (30)
424 (16-45/64)
243 (9-9/16)
A1
B1
C1
D1
F1
➊ Only CSA Certified HRCI-J and HRCI-MISC (also UL Listed as Class CC) fuses and UL Listed Class J and CC fuses are suitable for use with
these disconnect switches.
➋ CSA HRCI-MISC fuses must also be UL Listed as Class CC fuses.
➌ Based on Allen-Bradley tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 947-3, UL 1087 and UL 98.
Product Selection — Page 4-64
Accessories — Page 4-69
Approximate Dimensions — Page 4-85
4-76
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Specifications, Continued
Non-Fused Disconnect Switches For CSA and UL Class Applications ➊
Electrical Ratings
194R-NN030P3
194R-NN060P3
194R-NN100P3
194R-NN200P3
194R-NN400P3
30 ➋
60 ➋
100 ➋
200 ➋
400 ➋
AC (V)
DC (V)
600
250
600
250
600
250
600
250
600
250
(A)
30
60
100
200
400
Maximum Short Circuit Prospective
(kA)
Fault Current
100
100
100
100
100
Cat. No.
Maximum Fuse Cartridge Size
Maximum Voltage
Ampere Rating
Fuse Operating Characteristics ➌
Time
Delay
NonTime
Delay
Time
Delay
NonTime
Delay
Time
Delay
NonTime
Delay
Time
Delay
NonTime
Delay
Time
Delay
NonTime
Delay
Maximum HP, 3ý AC
200V 60 Hz (HP)
230V 60 Hz (HP)
460V 60 Hz (HP)
575V 60 Hz (HP)
7.5
7.5
15
20
3
3
5
7.5
15
15
30
50
7.5
7.5
15
15
25
30
60
75
15
15
25
30
50
60
125
150
25
25
50
60
100
125
250
300
50
50
100
125
Maximum HP, 1∅ AC
115V 60 Hz (HP)
230V 60 Hz (HP)
2
3
.5
1.5
3
10
1.5
3
—
15
—
7.5
—
25
—
15
—
50
—
25
125V DC (HP)
250V DC (HP)
3
5
2
5
5
10
5
10
—
20
—
20
—
40
—
40
—
50
—
50
Maximum HP, DC
(W)
Power Lost
2
6
20
40
80
Mechanical Data
194R-NN030P3
194R-NN060P3
194R-NN100P3
194R-NN200P3
194R-NN400P3
IP20
IP20
IP20
IP20
IP00
IP20
IP00
IP20
IP00
IP20
10,000
10,000
10,000
8,000
8,000
4
35
4
35
17.5
155
20.3
180
31.4
275
mm2
AWG
2.5…6
#14…#8
2.5…25
#14…#4
2.5…35
#14…#2
16…120
#6…250MCM
Two 50…150
Two 1/
0…350MCM
mm2
AWG
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
2.5…4
#14…#12
Cat. No.
Degree of Protection (per IEC 947)
Switch Only
Switch with Terminal Shields
& Fuse Cover(s)
Mechanical Endurance ➌
Operating Torque (Maximum)
Terminal Capacity
Power Terminals
Auxiliary Contact Terminals
Operations
Nm
Lb.-In.
Maximum Number of Auxiliary Circuits
Approximate Weight
Minimum Enclosure Size
Approximate dimensions in
millimeters (inches)
kg.
Lbs.
Height
Width
Depth
Switch Dimension Reference
(See dimension drawings on pages 4-87,
4-88, 4-89 and 4-90.)
8
8
8
8
8
0.81
1.78
1.14
2.52
4.31
9.50
6.56
14.47
14.97
33.00
248 (9-3/4)
171 (6-3/4)
111 (4-3/8)
248 (9-3/4)
197 (7-3/4)
111 (4-3/8)
330 (13)
301 (11-27/32)
162 (6-3/8)
560 (22)
344 (13-17/32)
178 (7)
762 (30)
424 (16-45/64)
243 (9-9/16)
A2
B2
C1
D1
F1
➊ Non-fused disconnect switches must be used with separately installed CSA Certified HRCI-J, HRCI-T, or HRCI-MISC (also UL Listed as
Class CC) fuses; or UL Listed Class J, CC or T fuses.
➋ When using CSA HRCI-J, HRCI-MISC (also UL Listed as Class CC) or HRCI-T fuses, and UL Class J, CC or T fuses.
➌ Based on Allen-Bradley tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 947-3, UL 1087 and UL 98.
Product Selection — Page 4-64
4-77
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Specifications, Continued
All Bulletin 194R Disconnect Switch Cat. Nos.
Environmental Data
Ambient Temperature
Open ............................................................................. °C (F)
Enclosed ..................................................................... °C (F)
Storage ........................................................................ °C (F)
Altitude (per IEC 947-1)
–2…+55 (–4…+131)
–20…+40 (–4…+104)
–40…+65 (–40…+149)
m
2,000
90% @ +20°C (+68°F)
50% @ +40°C (+104°F)
Relative Humidity (per IEC 947-1)
Auxiliary Contact Ratings for Cat. No. 195-GA
AC11 Rating
DC11 Rating
Ue
(Volts)
le
(Amperes)
Ue
(Volts)
le
(Amperes)
12…120
220…240
380…480
500…600
6
3
1.5
1.2
28
110
220
440
600
5.0
1.25
0.62
0.27
0.20
Thermal Current — 10 Amperes. EEMAC/NEMA A600, P300.
Insulation Voltage IEC (Ui) — 660.
Wiring Schematic
L1
L2
L3
11
T1
T2
T3
12
LINE
LOAD
Product Selection — Page 4-64
4-78
Bulletin 194R
IEC Fused and Non-Fused Disconnects
4
Proper Selection of Disconnect Switches
Applications Within Canada and the United States
General
The requirements for disconnect switches used in motor
branch circuits rated 600V and less are defined in Article 430,
Part J of the U.S. National Electrical Code (NEC), NFPA70.
Canadian Electrical Code (CEC) requirements are very similar
in the area of motor branch circuit disconnect requirements.
For simplicity, we will treat the NEC and CEC requirements as
being the same — and reference specific sections of the U.S.
National Electrical Code.
The requirements for properly sizing a disconnect switch are
dependent on the type of application. The NEC refers to two
types of applications: single motor and combination loads. A
combination load consists of an application where two or more
motors are used together or where one or more motors are
used in combination with other loads, such as resistance
heaters.
started motors’ locked-rotor currents and the full-load currents
of the remaining operating motor and non-motor loads.
The disconnecting means shall have a current rating equal to
or greater than 115% of the equivalent single motor full-load
current and have a horsepower rating equal to or greater than
the horsepower rating determined from the equivalent lockedrotor summation.
Consider the following 460V application:
Load
HP
5
7.6 (simultaneous)
Motor 2
10
14.0 (not included) ➊
Motor 3
15
21.0 (simultaneous)
Motor 4
20
27.0 (simultaneous)
Other
7.0 (simultaneous)
Total Equivalent
Single Motor Applications
Section 430-110 Paragraph (a) states that the disconnect
switch must have an ampere rating of at least 115% of the
full-load current rating of the motor.
Example 1: For a motor with a full-load current of 22 A, the
disconnect switch must be rated at least 25.3 A (22 x 1.15).
If the disconnecting means under evaluation is rated in
horsepower, the selection of the disconnect switch is even more
straightforward; a disconnect switch must have a horsepower
rating equal to, or greater than the horsepower rating of the
motor at the applicable voltage.
Example 2: For a motor with a 10HP rating at 460V AC, the
disconnect switch must be rated at least 10HP at 460V AC.
If the disconnect switch is rated in horsepower, and UL Listed,
UL Component Recognized, or CSA Certified, it will meet the
requirements for the 115% full-load current rating stipulated by
the NEC.
Combination Load Applications
Section 430-110 Paragraph (c) addresses the rating of the
disconnecting means for combination loads. This paragraph
essentially requires that the loads that “may be simultaneous
on a single disconnecting means” be combined to provide
equivalent full-load and locked-rotor currents for what is then
to be considered as a single motor for the purpose of selecting
the appropriate disconnecting means. This means that it is
necessary to identify the particular combination of connected
loads which can be operating simultaneously and will result in
the maximum full-load and locked-rotor current sums.
The individual full-load current values are to be selected from
Tables 430-148, 430-149, or 430-150 and the locked-rotor
values are to be from Table 430-151.
The equivalent single motor full-load current is the sum of the
simultaneously operating motor full-load currents and the rating
in amperes of other loads operating at the same time. The
equivalent locked-rotor current is the sum of the simultaneously
Full-Load Current A
Motor 1
62.6 (simultaneous)
➊ Motor 2 is not included in the total since it cannot operate
simultaneously with the other motors, therefore, the disconnect
switch must be rated at least 72 A (1.15 x 62.6).
Consider now the locked-rotor current analysis for the same
application:
Load
HP
Full-Load Current A
Motor 1
5
Motor 2
10
84.0 (not included) ➊
Motor 3
15
126.0 (simultaneous) ➋
Motor 4
20
162.0 (simultaneous) ➋
Other
Total Equivalent
(7.6FLA) 45.6 (simultaneous)
7.0 (simultaneous)
302.6 (simultaneous)
➊ Note again that Motor 2 cannot operate simultaneously with the
other loads.
➋ The largest equivalent locked-rotor current occurs when motors 3
and 4 start together while the other loads marked “simultaneous”
are already operating. Since Motor 1 is not starting with Motors 3
and 4, its full-load current will be added to the total instead of its
locked-rotor current.
Table 430-151, which provides the correlation between
locked-rotor currents and HP ratings, shows that a 40 HP rating
is the equivalent for 302.6 locked-rotor amperes.
Therefore, the disconnect selected for this application must
have a current rating of at least 72 A and a HP rating of at least
40 HP. In this case a Bulletin 194R rated for 100 A and 60 HP
at 460V would be an appropriate choice. What can be seen
from this analysis is that, depending upon the number of
motors that can start simultaneously, the actual size of the
required disconnect is sometimes determined by the
equivalent full load current (72 A) and other times by the
equivalent horsepower determined from the locked-rotor
analysis (40 HP).
Product Selection — Page 4-64
4-79
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Proper Selection of Disconnect Switches, Continued
Applications Outside the United States and Canada
General
Disconnect switches designed to IEC Standards and used in applications outside of North America are selected based on the
ampere, horsepower, or kilowatt rating of the disconnect switch, under various utilization categories. Utilization categories for
disconnect switches are as follows:
Nature of
Current
AC
Utilization Category
Typical Applications
Frequent
Operation
Infrequent
Operation
AC-20A ➊
AC-20B ➊
Connecting and disconnecting under no-load conditions
AC-21A
AC-21B
Switching of resistive loads including moderate overloads
AC-22A
AC-22B
Switching of mixed resistive and inductive loads, including moderate overloads
AC-23A
AC-23B
Switching of motor loads or other highly inductive loads
➊ The use of these utilization categories is not permitted in the U.S.
For any application, the disconnect switch ampere, horsepower, or kilowatt rating must be greater than, or equal to, the application
full-load current or power (HP or kW), in the appropriate utilization category.
Example 1: For a 380V 50 Hz distribution application (AC-22A), with a 63 A full load current, the disconnect switch must be rated
at least 63 A at 380V 50 Hz for use in AC-22A applications.
Example 2: For a 415V 50 Hz motor application (AC-23A), with a 75 kW rating, the disconnect switch must be rated at least 75 kW
at 415V 50 Hz for use in AC-23A applications.
Renewal Parts
Hardware Kits (Includes switch/fuse mounting hardware and operating rod cotter pin)
Disconnect Switch
Cat. No.
Dim. Ref.
Cat. No.
194R-NH200P3
194R-ND250P3
194R-NB200P3
194R-NH100P3
194R-ND138P3
194R-NH400P3
194R-ND300P3
194R-NB300P3
194R-NN400P3
194R-NJ400P3
194R-NC030P3
194R-NJ030P3
194R-NN030P3
194R-NA100P3
194R-NA200P3
A1, A2
41022-316-02
41022-316-02
41022-316-02
41022-316-02
41022-316-02
194R-NJ060P3
194R-NN060P3
194R-NA300P3
B1, B2
41022-316-02
41022-316-02
41022-316-02
194R-NA380P3
194R-NN100P3
194R-NJ100P3
C1, C2
41022-800-03
41022-800-02
41022-800-01
194R-NA400P3
194R-NN200P3
194R-NJ200P3
194R-ND072P3
D1, D2
41022-800-07
41022-800-06
41022-800-05
41022-800-04
Product Selection — Page 4-64
4-80
Disconnect Switch
Hardware Kit
Part No.
Dim. Ref.
Hardware Kit
Part No.
E1, E2
41022-800-12
41022-800-11
41022-800-10
41022-800-09
41022-800-08
F1
41022-800-17
41022-800-16
41022-800-15
41022-800-14
41022-800-13
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Fuse Description
With Bulletin 194R Fused Disconnect Switches
Bulletin 194R Fused Disconnect Switches have been designed to accept a
variety of fuses for worldwide application flexibility. Following is a brief summary
of typical fuse specifications, where the fuses are typically used, and which
Bulletin 194R disconnect switches will accommodate each fuse type. Fuse
manufacturers should be contacted for more specific information about each
fuse type. Fuses are not available from Allen-Bradley.
D
K
A
BS88 Fuses (63 A shown)
Dimensions in millimeters (inches).
Dimensions are not intended to be
used for manufacturing purposes.
• IEC fuse type: Fuse-link for
bolted connection
• Voltage rating: 660/690V AC
• Interrupting rating: 80 kA
• Standard cartridge sizes: A1,
A2, A3, A4, B1, B2, B3, B4
• Typical ampere ratings:
2 A…400 A
• Construction: Blade type for
bolted connection
• Can be installed on Bulletin
194R disconnect switch Cat.
Nos: 194R-NA100P3,
NA200P3, NA300P3,
NA380P3, NA400P3,
NB200P3, NB300P3
• Where used: United Kingdom,
Australia, New Zealand, Asia
B
G
H
E
Standard cartridge size A1
D
D
M
F
K
F
A
B
B
A
G
G
H
E
E
H
J
J
Standard cartridge sizes B1, B2, B3, B4
Standard cartridge sizes A2, A3, A4
Dim. Ref.
F
Ampere Range (A)
A
B
D
E
F
G
H
K
A1
2…20
36.50
(1-7/16)
13.90
(35/64)
55.60
(2-3/16)
11.10
(7/16)
0.80
(1/32)
4.50
(1-3/4)
4.40
(11/64)
14.30
(9/16)
Dim. Ref.
Ampere Range (A)
A
B
D
E
F
G
H
J
K
A2
2…32
56.40
(2-7/32)
23.80
(15/16)
85.80
(3-3/8)
8.70
(11/32)
1.20
(3/64)
73.00
(2-7/8)
5.20
(13/64)
7.10
(9/32)
23.80
(15/16)
A3
35…63
56.40
(2-7/32)
23.80
(15/16)
85.80
(3-3/8)
8.70
(11/32)
1.20
(3/64)
73.00
(2-7/8)
5.20
(13/64)
7.10
(9/32)
23.80
(15/16)
A4
80…100
70.00
(2-3/4)
34.90
(1-3/8)
111.00
(4-3/8)
19.10
(3/4)
2.40
(3/32)
93.70
(3-11/16)
8.70
(11/32)
10.30
(13/32)
34.90
(1-3/8)
Dim. Ref.
Ampere Range (A)
A
B
D
E
F
G
H
J
M
B1
80…100
70.00
(2-3/4)
34.90
(1-3/8)
136.50
(5-3/8)
19.10
(3/4)
3.20
(1/8)
111.00
(4-3/8)
8.70
(11/32)
11.90
(15/32)
79.40
(3-1/8)
B2
125…200
77.00
(3-1/32)
41.30
(1-5/8)
136.50
(5-3/8)
19.10
(3/4)
3.20
(1/8)
111.00
(4-3/8)
8.70
(11/32)
11.90
(15/32)
79.40
(3-1/8)
B3
250…315
77.00
(3-1/32)
54.00
(2-1/8)
136.50
(5-3/8)
25.40
(1)
3.20
(1/8)
111.00
(4-3/8)
8.70
(11/32)
11.90
(15/32)
82.00
(3-1/4)
B4
355…400
83.00
(3-9/32)
61.10
(2-13/32)
136.50
(5-3/8)
25.40
(1)
6.30
(1/4)
111.00
(4-3/8)
8.70
(11/32)
11.90
(15/32)
85.80
(3-3/8)
Product Selection — Page 4-64
4-81
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Fuse Description, Continued
With Bulletin 194R Fused Disconnect Switches, Continued
DIN Fuses (100 A shown)
Dimensions in millimeters only.
Dimensions are not intended to be used for manufacturing
purposes.
• IEC fuse type: Fuse-link with blade contacts
• Voltage rating: 660/690V AC
• Interrupting rating: 120,000 A
• Standard cartridge sizes: 00, 0, 1 and 2
• Typical ampere ratings: 2…400 A
• Construction: Blade type
• Can be installed on Bulletin 194R disconnect switch
Cat. Nos: 194R-ND072P3, ND138P3, ND250P3, ND300P3
• Where used: Europe, South America, Middle East and India
e3
X
( 2 min.)
a4
a3
,
10 – 0.3
d
d
2.5 +0.5
e1
5 min.
b
c2
f
a2
6-0.3
e4
a1
e2
Size
Max. rated
current
(A)
a1
a2
a3
a4
b
(min.)
d
e1
(max.)
e2
(max.)
e3
e4
±0.2
f
00
100
78.5
±1.5
53
45
±1.5
49 ±1.5
15
2 ±0.5
48
30
20 ±5
6
12.5
0
160
125
±2.5
67
62 +3
–1.5
68 +1.5
–3
15
2 +1.5
–0.5
48
40
20 ±5
6
11.5
1
250
135
±2.5
71
62 ±2.5
68 ±2.5
20
2.5 +1.5
–0.5
53
52
20 +5
–2
6
10
2
400
150
±2.5
72
62 ±2.5
68 ±2.5
25
2.5 +1.5
–0.5
61
60
20 +5
–2
6
10
Product Selection — Page 4-64
4-82
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Fuse Description, Continued
With Bulletin 194R Fused Disconnect Switches, Continued
CSA HRCI and UL Class Fuses (10 A shown)
Dimensions in millimeters (inches).
Dimensions are not intended to be used for manufacturing
purposes.
• UL fuse type: Class CC
• CSA fuse type: HRCI-MISC
• Voltage rating: 600V AC
• Interrupting rating: 200,000 A
• Standard cartridge sizes: 30 A
• Typical ampere ratings: 1…30 A
38.1
(11/2)
• Construction: Ferrule type
• Can be installed on Bulletin 194R disconnect switch
Cat. No: 194R-NC030P3
9.5
(3/8)
• Where used: North America
CSA HRCI and UL Class Fuses (30 A shown)
Dimensions in millimeters (inches).
Dimensions are not intended to be used for manufacturing
purposes.
9.5
(3/8)
3.2
(1/8)
60.3
(2-3/8)
57.1
(2-1/4)
• CSA fuse type: HRCI-J
15.9
(5/8)
12.7
(1/2)
• UL fuse type: Class J
6.4
(1/4)
17.5
(1-1/16)
20.6
(13/16)
• Voltage rating: 600V AC
1A to 30A
35A to 60A
• Interrupting rating: 200,000 A
• Standard cartridge sizes: 30 A, 60 A,
100 A, 200 A and 400 A
• Typical ampere ratings: 1 -600 A; Blade type for bolted
connection
92
(3-5/8)
12.9
(1/2)
19
(3/4)
133 (5-1/4)
4.7
(3/16)
76.2
(3)
146
(5 3/4)
23.8
(15/16)
38.1
(1-1/2)
7.1
(9/32)
9.5
(3/8)
25.4
(1)
66.7
(2-5/8)
117. 5
(4-5/8)
110A
to200A
28.6
(1-1/8)
7.1
(9/32)
9.5
(3/8)
• Where used: North America
111.1
(4-3/8)
28.6
(1-1/8)
65A
to100A
• Can be installed on Bulletin 194R disconnect switch
Cat. Nos: 194R-NJ030P3, NJ060P3, NJ100P3,
NJ200P3, NJ400P3
17.5
(11/16)
3.2
(1/8)
34.9 (1-3/8)
41.3
(1-5/8)
225A
to
400A
13.5
(17/32)
85.7
(3-3/8)
6.4
(1/4)
50.8
(2)
10.3
(13/32)
47.6
(1-7/8)
181
(7-1/8)
Product Selection — Page 4-64
4-83
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Fuse Description, Continued
With Bulletin 194R Fused Disconnect Switches, Continued
CSA HRCII Fuses (100 A shown)
Dimensions in millimeters (inches).
Dimensions are not intended to be used for manufacturing
purposes.
• CSA fuse type: HRCII-C
• Voltage rating: 600V AC
• Interrupting rating: 200,000 A
• Standard cartridge sizes: 30 A, 60 A,
100 A, 200 A and 400 A
• Typical ampere ratings: 1…400 A
• Construction: Blade type for bolted
connection
• Can be installed on Bulletin 194R disconnect switch
Cat. Nos: 194R-NA200P3, NA300P3, NH100P3, NH200P3,
NH400P3
• Where used: Canada
F
G
F
F
G
G
G
D
E
E
C
B
A
E
H
C
B
A
D
H
H
C
B
A
J
H
D
Standard Cartridge Sizes 100 A, 200 A and 400 A
Standard Cartridge Sizes 30 A and 60 A
Range (A)
A
B
C
D
E
F
G
H
J
0…30
84.14
(3-5/16)
71.04
(2-51/64)
50.8
(2)
20.64
(13/16)
8.73
(11/32)
7.54
(19/64)
5.56
(7/32)
23.81
(15/16)
1.59
(1/16)
31…60
88.9
(3-1/2)
71.04
(2-51/64)
50.8
(2)
20.64
(13/16)
12.7
(1/2)
7.54
(19/64)
5.56
(7/32)
26.99
(1-1/16)
1.59
(1/16)
61…100
109.54
(4-5/16)
92.47
(3-41/64)
60.72
(2-25/64)
34.13
(1-11/32)
19.05
(3/4)
11.91
(15/32)
8.73
(11/32)
34.93
(1-3/8)
2.38
(3/32)
101…200
134.94
(5-5/16)
109.14
(4-19/64)
76.2
(3)
38.1
(1-1/2)
19.05
(3/4)
11.91
(15/32)
8.73
(11/32)
3.18
(1/8)
—
201…400
207.96
(8-3/16)
133.35
(5-1/4)
76.2
(3)
60.33
(2-3/8)
25.4
(1)
12.7
(1/2)
9.53
(3/8)
25.4
(1)
4.76
(3/16)
401…600
207.96
(8-3/16)
133.35
(5-1/4)
76.2
(3)
76.2
(3)
25.4
(1)
15.08
(19/32)
10.32
(13/32)
25.4
(1)
9.53
(3/8)
Product Selection — Page 4-64
4-84
E
G
Bulletin 194R
IEC Fused and Non-Fused Disconnects
4
Approximate Dimensions
Disconnect Switches
Disconnect Switch Dimension References A1, A2, B1 and B2 (30 A and 60 A)
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Disconnect Switch
Dimension Reference
A1
A2
B1
B2
Approximate Dimensions
H
W
D
A
B
FD
106
(4-11/64)
106
(4-11/64)
118
(4-21/32)
118
(4-21/32)
102
(4-1/64)
102
(4-1/64)
134
(5-9/32)
134
(5-9/32)
112
(4-13/32)
83
(3-17/64)
115
(4-33/64)
83
(3-17/64)
82
(3-15/64)
82
(3-15/64)
100
(3-15/16)
100
(3-15/16)
85
(3-11/32)
82
(3-15/64)
120
(4-23/32)
120
(4-23/32)
2-M4
2-#8
2-M4
2-#8
4-M4
4-#8
4-M4
4-#8
Disconnect Switch Dimension References C1, C2, D1, D2, E1, E2 and F1 (100 A, 200 A and 400 A)
Disconnect Switch
Dimension Reference
C1
C2
D1
D2
E1
E2
F1
Approximate Dimensions
H
W
D
A
B
FD
148
(5-53/64)
148
(5-53/64)
184
(7-1/4)
184
(7-1/4)
220
(8-21/32)
220
(8-21/32)
250
(9-27/32)
194
(7-41/64)
194
(7-41/64)
236
(9-19/64)
236
(9-19/64)
278
(10-15/16)
278
(10-15/16)
308
(12-1/8)
130
(5-7/64)
136
(5-23/64)
148
(5-53/64)
153
(6-1/64)
213
(8-25/64)
213
(8-25/64)
213
(8-25/64)
106
(4-11/64)
106
(4-11/64)
106
(4-11/64)
106
(4-11/64)
150
(5-29/32)
150
(5-29/32)
150
(5-29/32)
170
(6-11/16)
170
(6-11/16)
212
(8-11/32)
212
(8-11/32)
252
(9-59/64)
252
(9-59/64)
282
(11-7/64)
4-M6
(4-1/4)
4-M6
(4-1/4)
4-M6
(4-1/4)
4-M6
(4-1/4)
4-M8
(4-5/16)
4-M8
(4-5/16)
4-M8
(4-5/16)
Product Selection — Page 4-64
4-85
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Approximate Dimensions, Continued
Operating Handles — Cat. No. 194R-HS.../190-HS
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
50
(1-31/32)
ON
25
(63/64)
76.2
(3)
O
F
F
25
(63/64)
35
(1.375 dia.)
50
(1-31/32)
76.2
(3)
40.3
(1-19/32)
18.4
(23/32)
2 – 5.5 mm
(4 –.219dia.)
Operating Handles — Cat. No. 194R-HM.../190-HM
75
(2-61/64)
37.5
(1-15/32)
37.5
(1-15/32)
65
(2-9/16 dia.)
75
(2-61/64)
4 – 5.5
(4 7/32 dia.)
Product Selection — Page 4-64
4-86
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Approximate Dimensions, Continued
Disconnect Switch Dim. Ref.: A1, A2, B1, B2 (30 A and 60 A)
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
25
(63/64)
1 Two(2) - M4
2.0 N . m
18 lb-in.
50
(1-31/32)
Two (2) – 5.5
(.219 dia.)
35
(1.38 dia.)
50
(1-31/32)
25
(63/64)
Cat. No.194R-NA100P3 (SER.B)
Cat. No.194R-NA200P3 (SER.B)
Cat. No.194R-NC030P3 (SER.B)
Cat. No. 194R-NJ030P3 (SER.B)
Cat. No.194R-NN030P3 (SER.B)
1 Four (4)-M4
2.0N .m
18 lb-in.
Cat. No.194R-NA300P3 (SER. B)
Cat. No. 194R-NJ060P3 (SER. B)
Cat. No.194R-NN060P3 (SER. B)
Disconnect Switch and Operating Handle
Installation Dimensions
➊ The switch is capable of accepting #8 screws 34.9 (1-3/8) for mounting.
Note: Enclosure Installation Dimensions A through F are listed on page 4-88.
Cat. No.
(SER. B)
Dim.
Ref.
G
H
J
A1,
A2
85
(3-11/32)
7.5
(19/64)
24.2
(61/64)
B1,
B2
120
(4-23/32)
10
(25/64)
28.5
(1-1/8)
K
L
M
N
64.8
41
(2-35/64) (1-39/64)
129.6
(5-7/64)
11.8
(15/32)
76.5
(3-1/64)
153
(6-1/32)
17.5
(11/16)
P
Q
R
S
T
U
106
82
(4-11/64) (3-15/64)
102
(4-1/64)
114.1
(4-1/2)
126.2
(4-31/32)
12
(15/32)
118
100
(4-21/32) (3-15/16)
134
(5-9/32)
146.1
(5-3/4)
158.2
(6-15/64)
16
(5/8)
194R-NA100P3
194R-NA200P3
194R-NC030P3
194R-NJ030P3
194R-NN030P3
194R-NA300P3
194R-NJ060P3
50
(1-31/32)
194R-NN060P3
Product Selection — Page 4-64
4-87
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Approximate Dimensions, Continued
Disconnect Switch Dim. Ref.: A1, A2, B1, B2 (30 A and 60 A)
Enclosure and Operating Handle
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
40.3
(1-19/32)
Enclosure Installation Dimensions
Cat. No.
Dim.
Ref.
A
B
D
E
Maximum
Minimum
Minimum
C
Maximum
Minimum
Minimum
Minimum
F
Maximum
194R-NA100P3 (SER. B)
194R-NA200P3 (SER. B)
194R-NC030P3 (SER. B)
194R-NJ030P3 (SER. B)
A1
171
(6-3/4)
45
(1-49/64)
147.6
(5-13/16)
454
(17-7/8)
248
(9-3/4)
89
(3-1/2)
1.4
(1/16)
4.78
(3/16)
194R-NN030P3 (SER. B)
A2
171
(6-3/4)
45
(1-49/64)
111
(4-3/8)
454
(17-7/8)
248
(9-3/4)
89
(3-1/2)
1.4
(1/16)
4.78
(3/16)
194R-NA300P3 (SER. B)
194R-NJ060P3 (SER. B)
B1
197
(7-3/4)
45
(1-49/64)
147.6
(5-13/16)
454
(17-7/8)
248
(9-3/4)
105
(4-9/64)
1.4
(1/16)
4.78
(3/16)
194R-NN060P3 (SER. B)
B2
197
(7-3/4)
45
(1-49/64)
111
(4-3/8)
454
(17-7/8)
248
(9-3/4)
105
(4-9/64)
1.4
(1/16)
4.78
(3/16)
Product Selection — Page 4-64
4-88
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Approximate Dimensions, Continued
Disconnect Switch Dim. Ref.: C1, C2, D1, D2 (100 A and 200 A)
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Four (4)-M6 x 12 1
4.0 N.m
35lb-in
75
(2-61/64)
Four (4) – 5.5
(.219 dia.)
140
(5-33/64)
37.5
(1-15/32)
65
(2-9/16 dia.)
75
(2-61/64)
37.5
(1-15/32)
58
(2-9/32)
➊ The switch is capable of accepting four (4)∅ 6.4 (1/4 dia.) screws for mounting.
Enclosure Installation Dimensions
A
Dimension
Reference
B
C
H
T
W
Minimum
Minimum
Minimum
Minimum
Maximum
Minimum
Minimum
Maximum
Single Pole
Aux. Cont.
Two Pole
Aux. Cont.
C1
108
(4-1/4)
162
(6-3/8)
162
(6-3/8)
457
(18)
330
(13)
1.6
(1/16)
4.8
(3/16)
301
(11-27/32)
313
(12-5/16)
C2
108
(4-1/4)
162
(6-3/8)
168
(6-5/8)
457
(18)
330
(13)
1.6
(1/16)
4.8
(3/16)
301
(11-27/32)
313
(12-5/16)
D1
108
(4-1/4)
280
(11)
178
(7)
457
(18)
560
(22)
1.6
(1/16)
4.8
(3/16)
344
(13-17/32)
356
(14)
D2
108
(4-1/4)
280
(11)
183
(7-7/32)
457
(18)
560
(22)
1.6
(1/16)
4.8
(3/16)
344
(13-17/32)
356
(14)
Disconnect Switch and Operating Handle Installation Dimensions
Dimension
Reference
D
E
F
G
J
K
L
M
N
P
Q
C1, C2
74
(2-29/32)
53
(2-3/32)
106
(4-3/16)
170
(6-11/16)
148
(5-53/64)
176
(6-15/16)
88
(3-15/32)
13.5
(17/32)
12.7
(1/2)
194
(7-41/64)
206
(8-7/64)
D1, D2
162
(6-23/64)
53
(2-3/32)
106
(4-3/16)
212
(8-11/32)
184
(7-1/4)
236
(9-9/32)
118
(4-41/64)
26
(1-1/32)
12.7
(1/2)
236
(9-19/64)
248
(9-49/64)
Product Selection — Page 4-64
4-89
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Approximate Dimensions, Continued
Disconnect Switch Dim. Ref.: E1, E2, F1 (200 A and 400 A)
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
Four (4)–M8x1.25 1
6.0N .m
55lb-in
Four (4)– 5.5
(.219 dia.)
65
(2-9/16 dia.)
➊ The switch is capable of accepting four (4)∅ 7.9 (5/16 dia.) screws for mounting.
Enclosure Installation Dimensions
A
Dimension
Reference
B
C
H
T
W
Minimum
Minimum
Minimum
Minimum
Maximum
Minimum
Minimum
Maximum
Single Pole
Aux. Cont.
Two Pole
Aux. Cont.
E1
108
(4-1/4)
305
(12)
227
(8-15/16)
610
(24)
610
(24)
1.6
(1/16)
4.8
(3/16)
394
(15-33/64)
406
(16)
E2
108
(4-1/4)
356
(14)
227
(8-15/16)
610
(24)
712
(28)
1.6
(1/16)
4.8
(3/16)
394
(15-33/64)
406
(16)
F1
108
(4-1/4)
381
(15)
243
(9-9/16)
610
(24)
762
(30)
1.6
(1/16)
4.8
(3/16)
606
(23-7/8)
606
(23-7/8)
Disconnect Switch and Operating Handle Installation Dimensions
Dimension
Reference
D
E
F
G
J
E1
158
(6-7/32)
75
(2-61/64)
150
(5-29/32)
252
(9-59/64)
220
(8-21/32)
E2
209
(8-7/32)
75
(2-61/64)
150
(5-29/32)
252
(9-59/64)
F1
202
(7-61/64)
75
(2-61/64)
150
(5-29/32)
282
(11-7/64)
Product Selection — Page 4-64
4-90
K
L
M
N
P
Q
294
147
(11-37/64) (5-25/32)
37
(1-29/64)
14
(35/64)
278
(10-15/16)
290
(11-13/32)
220
(8-21/32)
294
147
(11-37/64) (5-25/32)
37
(1-29/64)
14
(35/64)
278
(10-15/16)
290
(11-13/32)
250
(9-27/32)
358
(14-3/32)
54
(2-1/8)
14
(35/64)
308
(12-1/8)
320
(12-19/32)
179
(7-3/64)
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Approximate Dimensions, Continued
IP66 (Type 3/4/12) Watertight, Dusttight Sheet Metal Enclosure
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
External Mounting Feet Optional Cat. No. 198-F1
(A)
Type
Dim. Ref.
A
B
C
D
E
F
G
H
30
Non-Fused
& Fused
A1 & A2
200
(7-7/8)
300
(11-13/16)
160
(6-19/64)
200
(7-7/8)
325
(12-51/64)
313
(12-21/64)
105
(4-1/8)
236
(9-9/32)
60
Non-Fused
& Fused
B1 & B2
200
(7-7/8)
300
(11-13/16)
160
(6-19/64)
200
(7-7/8)
325
(12-51/64)
313
(12-21/64)
105
(4-1/8)
236
(9-9/32)
100
Non-Fused
& Fused
C1
400
(15-3/4)
350
(13-25/32)
180
(7-3/32)
220
(8-21/32)
375
(14-3/4)
363
(14-19/64)
206
(8-1/8)
286
(11-1/4)
External Mounting Feet Optional Cat. No. 198-F3
(A)
Type
Dim. Ref.
A
B
C
D
E
F
G
H
200
Non-Fused
& Fused
D1
406
(16)
610
(24)
224
(8-51/64)
282
(11-5/64)
688
(27-5/64)
648
(25-1/2)
368
(14-1/2)
572
(22-1/2)
400
Non-Fused
& Fused
F1
610
(24)
762
(30)
326
(12-51/64)
384
(15-5/64)
840
(33-5/64)
800
(31-1/2)
572
(22-1/2)
724
(28-1/2)
Product Selection — Page 4-64
4-91
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Approximate Dimensions, Continued
Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
External Mounting Feet Standard
External Mounting Feet Optional Cat. No. 198-F3
(A)
Type
Dim. Ref.
A
A1
B
C
D
E
F
G
H
Non-Fused
A2
159
(6-1/4)
170
(6-11/16)
240
(9-7/16)
123
(4-27/32)
163
(6-7/16)
273
(10-3/4)
254
(10)
83
(3-1/4)
–
Fused
A1
214
(8-7/16)
225
(8-7/8)
265
(10-7/16)
125
(4-29/32)
165
(6-1/2)
298
(11-23/32)
229
(11)
83
(3-1/4)
–
Non-Fused
& Fused
B1 & B2
214
(8-7/16)
225
(8-7/8)
265
(10-7/16)
125
(4-29/32)
165
(6-1/2)
298
(11-23/32)
229
(11)
83
(3-1/4)
–
30
60
External Mounting Feet Optional Cat. No. 198-F3
(A)
Type
Dim. Ref.
A
A1
B
C
D
E
F
G
H
100
Non-Fused
& Fused
C1
508
(20)
–
406
(16)
224
(8-51/64)
282
(11-7/64)
484
(19-5/64)
444
(17-1/2)
470
(18-1/2)
368
(14-1/2)
200
Non-Fused
& Fused
D1
406
(16)
–
610
(24)
224
(8-51/64)
282
(11-5/64)
688
(27-5/64)
648
(25-1/2)
368
(14-1/2)
572
(22-1/2)
300
Non-Fused
& Fused
F1
610
(24)
–
762
(30)
326
(12-51/64)
384
(15-5/64)
840
(33-5/64)
800
(31-1/2)
572
(22-1/2)
724
(28-1/2)
Product Selection — Page 4-64
4-92
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Approximate Dimensions, Continued
IP66 (Type 3/4/4X/12) Corrosion Resistant, Non-Metallic Enclosure
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
K
6
(15/64)
A
H
D
C
J
F B
(4)-.31 X .50 SLOT MTG. HOLES
(8)
(13)
G
32
(1-1/4)
Cat. No. 194R-K_30P3, 194R-K_60P3
30 and 60 A Switch
K
5
(3/16)
A
H
D
C
F B
J
G
32
(1-9/32)
(4)-.31 X .50 SLOT MTG. HOLES
(8)
(13)
Cat. No. 194R-K_100P3
100 A Switch
Switch Size
(A)
A
B
C
D
F
G
H
J
K
30/60
226
(8-59/64)
267
(10-1/2)
163
(6-27/64)
202
(7-61/64)
278
(10-61/64)
152
(6)
216
(8-1/2)
305
(12)
6
(15/64)
100
379
(14-15/16)
420
(16-1/4)
215
(8-31/64)
273
(10-49/64)
430
(16-61/64)
305
(12)
370
(14-9/16)
457
(18)
5
(13/64)
Product Selection — Page 4-64
4-93
Bulletin 194R
IEC Fused and Non-Fused Disconnects
Approximate Dimensions, Continued
IP66 (Type 3/4/4X/12) Corrosion Resistant, Non-Metallic Enclosure, Continued
Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.
K
11
(29/64)
F
D
A
C
B
J
(4)-.41 DIA. MTG. HOLES
(10)
G
Cat. No. 194R-K_200P3
200 A Switch
K
11
(27/64)
D
C
A
B
F
J
(4)-.41 DIA. MTG. HOLES
(10)
G
Cat. No. 194R-K_400P3
400 A Switch
Switch Size
(A)
A
B
C
D
F
G
J
K
200
513
(20-13/64)
625
(24-5/8)
292
(11-31/64)
350
(13-25/32)
648
(25-1/2)
457
(18)
686
(27)
11
(7/16)
400
612
(24-1/8)
775
(30-33/64)
342
(13-31/64)
401
(15-25/32)
796
(31-11/32)
555
(21-7/8)
834
(32-27/32)
11
(27/64)
Product Selection — Page 4-64
4-94