Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Bulletin 194R • 20 A…400 A Sizes • Open or Enclosed Switches • Fused Switch Versions: • BS88 • DIN • CSA HRCII-C • CSA HRCI-J • UL Class J • UL Class CC • Non-Fused Switches • Operating Handle Ingress Ratings: • IP42 (Type 1) • IP66 (Type 3R, 3, 12, 4, 4X) • Handle with or without Defeater Mechanism • Padlockable Handle with up to Three Padlocks • Up to 8 Auxiliary Contacts can be Added Per Switch • Suitable as Service Entrance Disconnecting Means TABLE OF CONTENTS Description Page Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disconnect Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Shafts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disconnect Switch Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Enclosed Disconnect Switches. . . . . . . . . . . . . . . . . . . . . . . . . 4-64 4-64 4-66 4-67 4-68 4-69 Description Page Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-69 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-72 Proper Selection of Disconnect Switches . . . . . . . . . . . . . . . . 4-79 Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-80 Fuse Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-81 Approximate Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-85 A-B EXPRESS Fast Shipment Program Description The Bulletin 194R line of fused and non-fused IEC disconnect switches provides the flexibility to meet worldwide applications. These rod operated disconnect switches incorporate on-board fuse carriers thus reducing panel space requirements and have high short circuit protection ratings. The disconnect switches are UL Listed, CSA, ASTA and LOVAG Certified and are designed to meet IEC 947-3, VDE, DIN, BS and applicable NEMA requirements. Conformity to Standards: Approvals: IEC 947-3/EN60947-3 BS EN60947-3 VDE 0660 CSA 22.2 No. 4 NEMA KS-1 UL 1087/489 UL 98 ASTA Certified LOVAG Certified CE (IEC 947-3) CSA Certified (File No. LR 1234) UL Listed (File No. E 119349/E 14840) Bulletin 198 Rotary Circuit Breaker Operating Mechanism — See Page 4-102 • Fast Shipment of Bulletin 194R Products to satisfy your unexpected demands • Make your selection from any of the Cat. Nos. listed in blue and mark your order as Your order must include: • The desired disconnect switch Cat. No. Note the disconnect switch dimension reference. • The appropriate operating handle and operating shaft Cat. No. corresponding to the dimension reference of the disconnect switch. • The desired accessories Cat. No. (if required) for the application, corresponding to the dimension reference of the disconnect switch. 4-63 Bulletin 194R IEC Fused and Non-Fused Disconnects Product Selection BS88 Fused Disconnect Switches Ratings (AC23) With Fuse Links Load Rating Ie (A) With Shorting Links 3∅ Maximum kW (50 Hz) 200/ 230V 380/ 400/ 415V 20 ➊ 3 7.5 7.5 — 32 7.5 15 18.5 11 60 11 30 30 75 22 37 138 37 245 300 Load Rating Ie (A) 3∅ Maximum kW (50 Hz) Dim. Ref. Cat. No. BS88 A1 A1 194R-NA100P3 BS88 A2 A1 194R-NA200P3 BS88 A3 B1 194R-NA300P3 55 BS88 A3 C1 194R-NA380P3 90 110 BS88 A4 D1 194R-NA400P3 132 160 160 BS88 B1, B2 E1 194R-NB200P3 160 200 200 BS88 B1, B2 B3, B4 F1 194R-NB300P3 200/ 230V 380/ 400/ 415V 500V 660/ 690V 32 7.5 15 18.5 11 — — — — — 30 63 11 30 30 30 45 55 75 22 37 45 75 90 110 138 37 75 75 132 160 160 245 75 90 160 200 200 300 40 500V 660/ 690V Fuse Type DIN Fused Disconnect Switches Ratings (AC23) With Fuse Links Load Rating Ie (A) 3∅ Maximum kW (50 Hz) 200/ 230V 380/ 400/ 415V 500V 660/ 690V Fuse Type Dim. Ref. Cat. No. 75 22 37 45 55 DIN 00 C2 194R-ND072P3 138 37 75 90 110 DIN 0, 00 ➋ D2 194R-ND138P3 245 75 132 160 160 DIN 1 E2 194R-ND250P3 300 90 160 200 200 DIN 1, 2 F1 194R-ND300P3 ➊ Maximum ampere rating is 32 A if shorting links, Cat. No. 194R-SLA1, is used. See page 4-71. ➋ Series C only. Accessories — Page 4-69 Specifications — Page 4-72 Approximate Dimensions — Page 4-85 4-64 Bulletin 194R IEC Fused and Non-Fused Disconnects Product Selection, Continued UL/CSA Fused Disconnect Switches Fast Shipment Program Cat. Nos. are printed in blue. Cat. No. 194R-NA300P3 Cat. No. 194R-NJ100P3 Cat. No. 194R-NC030P3 Maximum HP Ratings ➊ Ampere Rating (A) 115V 230V 200V 230V 460V 30 2 3 7-1/2 7-1/2 15 20 — — 60 3 10 15 15 30 30 — — 100 — 15 25 30 60 75 — — 200 — 30 50 60 125 150 — 400 — 50 100 125 250 300 — 1∅ (60 Hz) 3∅ (60 Hz) Fuse Type Dim. Ref. Cat. No. 30 A HRCII-C A1 194R-NA200P3 60 A HRCII-C B1 194R-NA300P3 100 A HRCII-C D1 194R-NH100P3 — 200 A HRCII-C E1 194R-NH200P3 — 400 A HRCII-C F1 194R-NH400P3 DC 575V 125V 250V CSA HRCII-C FUSES UL CLASS CC & J AND CSA HRCI-J FUSES ➋ 30 3/4 2 5 5 10 10 2 3 30 A CLASS CC A1 194R-NC030P3 30 2 3 7-1/2 7-1/2 15 20 3 5 30 A CLASS J A1 194R-NJ030P3 60 3 10 15 15 30 50 5 10 60 A CLASS J B1 194R-NJ060P3 100 7-1/2 15 25 30 60 75 — 20 100 A CLASS J C1 194R-NJ100P3 ➍ 200 — 25 50 60 125 150 — 40 200 A CLASS J D1 194R-NJ200P3 400 — 50 100 125 250 300 — 50 400 A CLASS J F1 194R-NJ400P3 Dim. Ref. Cat. No. 194R-NN030P3 UL/CSA Non-Fused Disconnect Switches Non-Fused Fuse Description ➌ ➊ ➋ ➌ ➍ Ampere Rating (A) Maximum HP Ratings 1∅ (60 Hz) 115V 3∅ (60 Hz) DC 230V 200V 230V 460V 575V 125V 250V 30 2 3 7-1/2 7-1/2 15 20 3 5 A2 60 3 10 15 15 30 50 5 10 B2 194R-NN060P3 100 7-1/2 15 25 30 60 75 — 20 C1 194R-NN100P3 ➍ 200 — 25 50 60 125 150 — 40 D1 194R-NN200P3 400 — — 100 125 250 300 — 50 F1 194R-NN400P3 Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower rating. Only CSA Certified HRCI-J and UL Listed Class J and CC fuses are suitable for use with these disconnect switches. Non-fused disconnect switches must use separately installed CSA Certified HRCI-J fuses or UL Listed Class J, CC or T fuses. Line and Load Terminals use 4 mm Allen-type wrench; will not accept terminal lugs. Accessories — Page 4-69 Specifications — Page 4-72 Approximate Dimensions — Page 4-85 4-65 Bulletin 194R IEC Fused and Non-Fused Disconnects Product Selection, Continued Operating Handles Fast Shipment Program Cat. Nos. are printed in blue. Disconnect Switch Dim. Ref. Description Color Degree of Protection Cat. No. IP42 (Type 1) 194R-HS1 IP66 (Type 3R, 3, 12, 4, 4X) 194R-HS4 IP42 (Type 1) 194R-HS1E IP66 (Type 3R, 3, 12, 4, 4X) 194R-HS4E IP42 (Type 1) 194R-HS1-N2 IP66 (Type 3R, 3, 12, 4, 4X) 194R-HS4-N2 IP42 (Type 1) 194R-HS1E-N2 IP66 (Type 3R, 3, 12, 4, 4X) 194R-HS4E-N2 IP42 (Type 1) 194R-HM1 IP66 (Type 3R, 3, 12, 4, 4X) 194R-HM4 IP42 (Type 1) 194R-HM1E IP66 (Type 3R, 3, 12, 4, 4X) 194R-HM4E IP42 (Type 1) 194R-HM1-N2 IP66 (Type 3R, 3, 12, 4, 4X) 194R-HM4-N2 IP42 (Type 1) 194R-HM1E-N2 IP66 (Type 3R, 3, 12, 4, 4X) 194R-HM4E-N2 IP42 (Type 1) 194R-HM1-N1 IP66 (Type 3R, 3, 12, 4, 4X) 194R-HM4-N1 IP42 (Type 1) 194R-HM1E-N1 IP66 (Type 3R, 3, 12, 4, 4X) 194R-HM4E-N1 IP42 (Type 1) 194R-HM1-N3 IP66 (Type 3R, 3, 12, 4, 4X) 194R-HM4-N3 IP42 (Type 1) 194R-HM1E-N3 IP66 (Type 3R, 3, 12, 4, 4X) 194R-HM4E-N3 Black With Defeater Red/Yellow A1, A2 B1, B2 Black Without Defeater Red/Yellow Black Standard Orientation With Defeater Red/Yellow Black Standard Orientation Without Defeater Red/Yellow C1, C2 D1, D2 E1, E2 F1 Black 90° Rotated Orientation With Defeater Red/Yellow Black 90° Rotated Orientation Without Defeater Red/Yellow Accessories — Page 4-69 Specifications — Page 4-72 Approximate Dimensions — Page 4-85 4-66 Bulletin 194R IEC Fused and Non-Fused Disconnects Product Selection, Continued Operating Shafts Disconnect Switch Dim. Ref. A1, A2 B1, B2 C1, C2 D1, D2 E1, E2 F1 A1, A2 B1, B2 Description Operating Shaft Length Approx. Dim. mm (in.) Standard Length 263 (10.3) Extended Length 457 (18.0) Standard Length Extended Length Standard Length Extended Length 200 (7.9) 403 (15.9) 278 (10.9) 532 (20.9) Standard Length for Medium Handle 263 (10.3) Extended Length for Medium Handle 457 (18.0) Enclosure Working Depth Disconnect Switch Dim. Ref. Minimum Approx. Dim. mm (in.) Maximum Approx. Dim. mm (in.) Cat. No. A1, B1 148 (5.8) 260 (10.2) A2, B2 111 (4.4) 260 (10.2) A1, B1 148 (5.8) 454 (17.8) A2, B2 111 (4.4) 454 (17.8) 183 (7.2) 254 (10.0) 194R-R3 183 (7.2) 457 (18.0) 194R-R4 243 (9.6) 356 (14.0) 194R-R5 243 (9.6) 610 (24.0) 194R-R6 148 (5.8) 111 (4.4) 148 (5.8) 111 (4.4) 260 (10.2) 260 (10.2) 454 (17.8) 454 (17.8) C1, C2 D1, D2 194R-R1 194R-R2 E1, E2, F1 A1, B1 A2, B2 A1, B1 A2, B2 194R-R1M ➊ 194R-R2M ➊ ➊ Use with 194R HM*** Handle and 194R 30 A or 60 A switch. Accessories — Page 4-69 Specifications — Page 4-72 Approximate Dimensions — Page 4-85 4-67 Bulletin 194R IEC Fused and Non-Fused Disconnects Product Selection, Continued Complete UL/CSA Disconnect Switch Kits Fast Shipment Program Cat. Nos. are printed in blue. • Includes Disconnect Switch, Operating Handle and Operating Shaft Load Rating (A) 30 Maximum Horsepower Ratings ➊ 3∅ (60 Hz) Disconnect Switch ➋ 200V 230V 460V 575V Fuse Carrier Dim. Ref. 7.5 7.5 15 20 Non-Fused A2 7.5 7.5 15 20 30 A Class J A1 5 5 10 10 30 A Class CC A1 15 15 30 50 Non-Fused B2 15 15 30 50 60 A Class J B1 25 30 60 75 Non-Fused C1 25 30 60 75 100 A Class J C1 50 60 125 150 Non-Fused D1 50 60 125 150 200 A Class J D1 100 125 250 300 Non-Fused F1 100 125 250 300 400 A Class J F1 Operating Shaft Type Operating Handle Degree of Ingress Protection 60 100 200 400 Standard Length IP66 (Type 3R, 3, 12, 4, 4X) Cat. No. Color Black 194R-NN030P34R1 Red/Yellow 194R-NN030P34ER1 Black 194R-NJ030P34R1 Red/Yellow 194R-NJ030P34ER1 Black 194R-NC030P34R1 Red/Yellow 194R-NC030P34ER1 Black 194R-NN060P34R1 Red/Yellow 194R-NN060P34ER1 Black 194R-NJ060P34R1 Red/Yellow 194R-NJ060P34ER1 Black 194R-NN100P34R3 Red/Yellow 194R-NN100P34ER3 Black 194R-NJ100P34R3 Red/Yellow 194R-NJ100P34ER3 Black 194R-NN200P34R3 Red/Yellow 194R-NN200P34ER3 Black 194R-NJ200P34R3 Red/Yellow 194R-NJ200P34ER3 Black 194R-NN400P34R5 Red/Yellow 194R-NN400P34ER5 Black 194R-NJ400P34R5 Red/Yellow 194R-NJ400P34ER5 ➊ Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower ratings. ➋ Only UL Listed Class J and CC, and CSA Certified HRCI-J fuses are suitable for use with these disconnect switches. Accessories — Page 4-69 Specifications — Page 4-72 Approximate Dimensions — Page 4-85 4-68 Bulletin 194R IEC Fused and Non-Fused Disconnects Product Selection, Continued/Accessories UL Enclosed Disconnect Switches (Fused and Non-Fused) Fast Shipment Program Cat. Nos. are printed in blue. Stainless Steel Enclosure Maximum Horsepower Ratings Ampere Rating (A) 1∅ (60Hz) 3∅ (60Hz) 115V 230V 200V 230V 460V 575V 3/4 2 5 5 10 10 2 3 7-1/2 7-1/2 15 20 60 3 10 15 15 30 50 100 7-1/2 15 25 30 60 75 200 — 25 50 60 125 150 400 — 50 100 125 250 300 30 IP66 (Type 4/4X) Watertight, Corrosion-Resistant Stainless Steel Enclosure IP66 (Type 4/4X) Watertight, Corrosion-Resistant Non-Metallic Enclosure Fuse Description Dim. Ref. IP66 (Type 3/4/12) Watertight Dusttight Sheet Metal Enclosure Cat. No. ➊ Cat. No. ➊ Cat. No. ➊ Class CC Fused A1 194R-FC030P3 194R-CC030P3 194R-KC030P3 Class J Fused A1 194R-FJ030P3 194R-CJ030P3 194R-KJ030P3 Non-Fused A2 194R-FN030P3 194R-CN030P3 194R-KN030P3 Class J Fused B1 194R-FJ060P3 194R-CJ060P3 194R-KJ060P3 Non-Fused B2 194R-FN060P3 194R-CN060P3 194R-KN060P3 Class J Fused C1 194R-FJ100P3 194R-CJ100P3 194R-KJ100P3 Non-Fused C1 194R-FN100P3 194R-CN100P3 194R-KN100P3 Class J Fused D1 194R-FJ200P3 194R-CJ200P3 194R-KJ200P3 Non-Fused D1 194R-FN200P3 194R-CN200P3 194R-KN200P3 Class J Fused F1 194R-FJ400P3 194R-CJ400P3 194R-KJ400P3 Non-Fused F1 194R-FN400P3 194R-CN400P3 194R-KN400P3 ➊ Black operating handles supplied as standard. To order Red/Yellow Handles, add string suffix “E” to the Cat. No. Example: Cat. No. 194R-FC030P3E. Operating Shaft Guide Disconnect Switch Dim Ref. Pkg. Qty. Cat. No. A1, A2, B1, B2 1 194R-HSG1 Disconnect Switch Dim Ref. Pkg. Qty. Cat. No. A1, A2, B1, B2 1 194R-R1G C1, C2, D1, D2 1 194R-R3G Shaft Guard Specifications — Page 4-72 Approximate Dimensions — Page 4-85 4-69 Bulletin 194R IEC Fused and Non-Fused Disconnects Accessories, Continued Operating Shaft Coupler Disconnect Switch Dim Ref. Pkg. Qty. Cat. No. A1, A2, B1, B2 1 194R-SC1 Operating Handle Instruction Label Disconnect Switch Dim Ref. Conductor Range Pkg. Qty. Cat. No. ALL — 10 194R-L1 Fuse Covers CSA/UL 30/60 A non-fused switches come with fuse covers as standard. Disconnect Switch Dim. Ref. A1, A2 B1, B2 Quantity Required Per Disconnect Switch 194R-FCA2 1 194R-FCJ60 194R-FCC1 C1 C2 D1, D2 Cat. No. 194R-FCA2 Cat. No. 194R-FCD1 Cat. No. 194R-FCC2 3 194R-FCD1 E1, E2 194R-FCE1 F1 194R-FCF1 Terminal Shields ➊ CSA/UL switches come with line side shield as standard. Disconnect Switch Dim. Ref. Quantity Required Per Disconnect Switch Cat. No. A1, A2 194R-LNC1 B1, B2 194R-LNC2 C1, C2 D1, D2 194R-LNC3 2 194R-LNC4 E1, E2 194R-LNC5 F1 194R-LNC6 Terminal Lugs Disconnect Switch Dim Ref. Conductor Range Pkg. Qty. D1 (Cat. No. 194R-NH100P3 only) 10 mm 2…50 mm2 #8…1/0 AWG D1 (Cat. No. 194R-NJ200P3, NN200P3, NA400P3) D2 16 mm 2…120 mm2 #6…250MCM AWG E1, E2 25 mm 2…240 mm2 #4…500MCM AWG 199-LG1 F1 Two 50 mm2…150 m2 Two 1/0…350MCM AWG 199-LH1 Cat. No. 199-LE1 3 199-LF1 ➊ For use on either Line or Load Side of Disconnect Switch. Disconnect switch Cat. Nos: 194R-NN**P3, 194R-NJ**P3 and 194R-NC**P3 are provided as standard with a line side terminal shield. Product Selection — Page 4-64 4-70 Bulletin 194R IEC Fused and Non-Fused Disconnects Accessories, Continued Auxiliary Contacts ➊ Disconnect Switch Dim. Ref. Description Contact Configuration Cat. No. A1, A2 B1, B2 Auxiliary Contact Adapter — 194R-AA 1 N.O. 195-GA10 ALL ➋ Single Pole ➌ 1 N.C. 195-GA01 1 N.O.…1 N.C. 195-GA11 2 N.O. 195-GA20 2 N.C. 195-GA02 — 194R-A1 Cat. No. 194R-AA Cat. No. 195-GA10 ALL ➋ Two Pole ➌ Auxiliary Support For 5…8 Circuits Per Switch ALL Shorting Links For BS Switches Only Disconnect Switch Dim. Ref. Description A1 BS88 Size A1 B1 C1 BS88 Size A3 For Use with Cat. No. Cat. No. 194R-NA100P3 194R-SLA1 194R-NA300P3 194R-NA380P3 D1 BS88 Size A4 194R-NA400P3 E1 BS88 Size B1, B2 194R-NB200P3 F1 BS88 Size B3, B4 194R-NB300P3 194R-SLA3 194R-SLA4 194R-SLB2 Disconnect Switch Padlocking Kit Disconnect Switch Dim Ref. Pkg. Qty. Cat. No. A1, A2 B1, B2 1 194R-P1 ➊ See page 4-78 for contact ratings. ➋ Disconnect switches with dimension reference A1, A2, B1 and B2 require a quantity of one (1) auxiliary contact adapter, Cat. No. 194R-AA, for installation of auxiliary contacts. ➌ A maximum of four (4) contact blocks (8 auxiliary contacts) can be installed on each disconnect switch. When more than two (2) contact blocks are used, a support kit Cat. No. 194R-A1 must be used. Product Selection — Page 4-64 4-71 Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Specifications Fused Disconnect Switches For BS88 Fuses Note: Table continued on page 4-73. Electrical Ratings 194R-NA100P3 194R-NA200P3 BS88 Dimension A1 A2 A3 (V) 660 660 660 80 80 80 Cat. No. Fuse Type Rated Insulation Voltage (Ui) Maximum Short Circuit Prospective Fault Current (kA) 194R-NA300P3 Fuse Links Shorting Links Fuse Links Fuse Links Shorting Links (A) (A) (A) (A) 20 20 20 — 32 32 32 32 32 32 32 32 63 63 63 63 63 63 63 63 Rated Operational Current AC-23A (le) 200/230V 50 Hz 380/400/415V 50 Hz 500V 50 Hz 660/690V 50 Hz (A) (A) (A) (A) 20 20 20 — 32 32 32 18 32 32 32 18 45 60 45 37 45 63 45 37 Rated Thermal Current (lthe) (A) 20 32 32 63 63 (kW) (kW) (kW) (kW) 3 7.5 7.5 — 7.5 15 18.5 11 7.5 15 18.5 11 11 30 30 30 11 30 30 30 Rated Operational Current AC-22A (le) 200/230V 50 Hz 380/400/415V 50 Hz 500V 50 Hz 660/690V 50 Hz Maximum kW, AC-23A 3∅ 200/230V 50 Hz 380/400/415V 50 Hz 500V 50 Hz 660/690V 50 Hz (A) Maximum Fuse Rating Maximum Motor Circuit Fuse Link Maximum Fuse Cut-off Current ➊ (kA) Rated Short Time Current, 1 Second (kA) 20 — 32 63 — 20M32 — 32M63 63M100 — 7.5 7.5 10 7.5 1 10 1 1 194R-NA100P3 194R-NA200P3 194R-NA300P3 IP 00 IP 20 IP 00 IP 20 IP 00 IP 20 Operations 10,000 10,000 10,000 Nm Lb.-In. 4 35 4 35 4 35 mm2 AWG 2.5…6 #14…#8 2.5…6 #14…#8 2.5…25 #14…#4 mm2 AWG 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 8 8 8 kg Lbs. 0.83 1.84 0.83 1.84 1.18 2.60 248 (9-3/4) 171 (6-3/4) 148 (5-13/16) 248 (9-3/4) 171 (6-3/4) 148 (5-13/16) 248 (9-3/4) 197 (7-3/4) 148 (5-13/16) A1 A1 B1 Mechanical Data Cat. No. Degree of Protection (per IEC 947) Switch Only Switch with Terminal Shield & Fuse Cover(s) Mechanical Endurance ➋ Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Maximum Number of Auxiliary Circuits Approximate Weight Height Minimum Enclosure Size Approximate dimensions in millimeters (inches) Width Depth Switch Dimension Reference (See dimension drawings on pages 4-87 and 4-88.) ➊ Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded. ➋ Based on Allen-Bradley tests in accordance with the requirements as defined in IEC 947-3. Product Selection — Page 4-64 4-72 Bulletin 194R IEC Fused and Non-Fused Disconnects Specifications, Continued Fused Disconnect Switches For BS88 Fuses, Continued Electrical Ratings 194R-NA380P3 194R-NA400P3 194R-NB200P3 194R-NB300P3 BS88 Dimension A3 A4 B1, B2 B1, B2, B3, B4 (V) 660 660 660 660 80 80 80 Cat. No. Fuse Type Rated Insulation Voltage (Ui) Maximum Short Circuit Prospective Fault Current (kA) Shorting Links Fuse Links Shorting Links Fuse Links Shorting Links Fuse Links Shorting Links (A) (A) (A) (A) 100 100 100 100 100 100 100 100 200 200 200 200 160 160 160 160 250 250 250 250 250 250 250 250 400 400 400 400 400 400 400 400 (A) (A) (A) (A) 75 75 65 61 75 75 65 61 130 138 130 118 130 138 130 118 240 245 220 170 240 245 220 170 300 300 290 220 300 300 290 220 (A) 100 100 160 160 200 250 400 400 22 37 45 55 22 37 45 55 37 75 90 110 37 75 90 110 75 132 160 160 75 132 160 160 90 160 200 200 90 160 200 200 — Rated Operational Current AC-22A (le) 200/230V 50 Hz 380/400/415V 50 Hz 500V 50 Hz 660/690V 50 Hz 80 Fuse Links Rated Operational Current AC-23A (le) 200/230V 50 Hz 380/400/415V 50 Hz 500V 50 Hz 660/690V 50 Hz Rated Thermal Current (lthe) Maximum kW, AC-23A 3∅ 200/230V 50 Hz 380/400/415V 50 Hz 500V 50 Hz 660/690V 50 Hz (kW) (kW) (kW) (kW) (A) Maximum Fuse Rating Maximum Motor Circuit Fuse Link Maximum Fuse Cut-off Current ➊ (kA) Rated Short Time Current, 1 Second (kA) 100 — 200 — 200 — 400 100M125 — 200M250 — ED355 — 400M450 — 14 14 20 20 33 33 40 40 2 4 7.5 12 194R-NA380P3 194R-NA400P3 194R-NB200P3 194R-NB300P3 IP 00 IP 20 IP 00 IP 20 IP 00 IP 20 IP 00 IP 20 Mechanical Data Cat. No. Degree of Protection (per IEC 947) Switch Only Switch with Terminal Shield & Fuse Cover(s) Mechanical Endurance ➋ Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Operations 10,000 8,000 8,000 8,000 Nm Lb.-In. 17.5 155 20.3 180 31.4 275 31.4 275 mm2 AWG 2.5…35 #14…#2 16…120 #6-250MCM 25…240 #4-500MCM Two 50…150 Two 1/0…350MCM mm2 AWG 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 8 8 8 8 kg Lbs. 4.03 8.88 6.16 13.59 9.30 20.50 23.83 30.50 330 (13) 301 (11-27/32) 162 (6-3/8) 560 (22) 344 (13-17/32) 178 (7) 610 (24) 394 (15-33/64) 227 (8-15/16) 762 (30) 424 (16-45/64) 243 (9-9/16) C1 D1 E1 F1 Maximum Number of Auxiliary Circuits Approximate Weight Height Minimum Enclosure Size Approximate dimensions in millimeters (inches) Width Depth Switch Dimension Reference (See dimension drawings on pages 4-89 and 4-90.) ➊ Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded. ➋ Based on Allen-Bradley tests in accordance with the requirements as defined in IEC 947-3. Product Selection — Page 4-64 4-73 Bulletin 194R IEC Fused and Non-Fused Disconnects Specifications, Continued Fused Disconnect Switches For DIN Fuses Electrical Ratings 194R-ND072P3 194R-ND138P3 194R-ND250P3 DIN Dimension 00 0 1 1, 2 (V) 660 660 660 660 100 100 100 100 Fuse Links Fuse Links Fuse Links Fuse Links Cat. No. Fuse Type Rated Insulation Voltage (Ui) Maximum Short Circuit Prospective Fault Current (kA) Rated Operational Current AC-22A (le) 194R-ND300P3 200/230V 50 Hz 380/400/415V 50 Hz 500V 50 Hz 660/690V 50 Hz (A) (A) (A) (A) 85 85 85 85 160 160 160 160 250 250 250 250 400 400 400 400 Rated Operational Current AC-23A (le) 200/230V 50 Hz 380/400/415V 50 Hz 500V 50 Hz 660/690V 50 Hz (A) (A) (A) (A) 75 72 65 61 130 138 130 118 240 245 220 170 300 300 290 220 Rated Thermal Current (lthe) (A) 85 160 250 400 (kW) (kW) (kW) (kW) 22 37 45 55 37 75 90 110 75 132 160 160 90 160 200 200 Maximum kW, AC-23A 3∅ 200/230V 50 Hz 380/400/415V 50 Hz 500V 50 Hz 660/690V 50 Hz (A) Maximum Fuse Rating Maximum Motor Circuit Fuse Link 100 200 250 400 100 200 250 400 Maximum Fuse Cut-off Current ➊ (kA) 14 20 33 40 Rated Short Time Current, 1 Second (kA) 2 4 7.5 12 Mechanical Data Cat. No. Degree of Protection (per IEC 947) Switch Only Switch with Terminal Shields & Fuse Cover(s) Mechanical Endurance ➋ Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Operations Nm Lb.-In. mm2 AWG mm2 AWG Maximum Number of Auxiliary Circuits Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) kg. Lbs. Height Width Depth Switch Dimension Reference (See dimension drawings on pages 4-89 and 4-90.) 194R-ND072P3 194R-ND138P3 194R-ND250P3 194R-ND300P3 IP 00 IP 20 IP 00 IP 20 IP 00 IP 20 IP 00 IP 20 10,000 8,000 8,000 8,000 17.5 155 20.3 180 31.4 275 31.4 275 2.5…35 #14…#2 16…120 #6…250MCM 25…240 #4…500MCM Two 50…150 Two 1/0…350MCM 2.5… 4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 8 8 8 8 4.15 9.16 6.17 13.61 9.41 20.75 14.06 31.00 330 (13) 301 (11-27/32) 168 (6-5/8) 560 (22) 344 (13-17/32) 183 (7-7/32) 712 (28) 394 (15-33/64) 227 (8-15/16) 762 (30) 424 (16-45/64) 243 (9-9/16) C2 D2 E2 F1 ➊ Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded. ➋ Based on Allen-Bradley tests in accordance with the requirements as defined in IEC 947-3. Product Selection — Page 4-64 4-74 Bulletin 194R IEC Fused and Non-Fused Disconnects Specifications, Continued Fused Disconnect Switches For CSA HRCII-C Fuses Electrical Ratings Cat. No. 194R-NA200P3 194R-NA300P3 194R-NH100P3 194R-NH200P3 194R-NH400P3 HRCII-C HRCII-C HRCII-C HRCII-C HRCII-C (A) 30 60 100 200 400 (V) 600 600 600 600 600 (A) 30 60 100 200 400 Maximum Short Circuit Prospective (kA) Fault Current 100 100 100 100 100 CSA Fuse Type Maximum Fuse Cartridge Size AC Maximum Voltage Ampere Rating Maximum HP, 3∅ AC 200V 60 Hz 230V 60 Hz 460V 60 Hz 575V 60 Hz (HP) (HP) (HP) (HP) 7.5 7.5 15 20 15 15 30 50 25 30 60 75 50 60 125 150 100 125 250 300 115V 60 Hz 230V 60 Hz (HP) (HP) 2 3 3 10 — 15 — 30 — 50 Maximum HP, 1∅ AC Mechanical Data Cat. No. Degree of Protection (per IEC 947) Switch Only Switch with Terminal Shields & Fuse Cover(s) Mechanical Endurance ➊ Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Operations Minimum Enclosure Size Approximate dimensions in millimeters (inches) 194R-NA300P3 194R-NH100P3 194R-NH200P3 194R-NH400P3 IP 00 IP 20 IP 00 IP 20 IP 00 IP 20 IP 00 IP 20 IP 00 IP 20 10,000 10,000 10,000 8,000 8,000 Nm Lb.-In. 4 35 4 35 20.3 180 31.4 275 31.4 275 mm2 AWG 2.5…6 #14…#8 2.5…25 #14…#4 10…50 #8…#1/0 25…240 #4…500MCM Two 50…150 Two 1/0…350MCM mm2 AWG 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 Maximum Number of Auxiliary Circuits Approximate Weight 194R-NA200P3 kg. Lbs. Height Width Depth Switch Dimension Reference (See dimension drawings on pages 4-87, 4-88, 4-89 and 4-90.) 8 8 8 8 8 0.83 1.84 1.18 2.60 6.16 13.59 9.30 20.50 13.83 30.50 248 (9-3/4) 171 (6-3/4) 148 (5-13/16) 248 (9-3/4) 197 (7-3/4) 148 (5-13/16) 384 (15-1/8) 344 (13-17/32) 178 (7) 610 (24) 394 (15-33/64) 227 (8-15/16) 762 (30) 424 (16-45/64) 243 (9-9/16) A1 B1 D1 E1 F1 ➊ Based on Allen-Bradley tests in accordance with the requirements as defined in CSA C22.2 No. 4 and IEC 947-3. Product Selection — Page 4-64 4-75 Bulletin 194R IEC Fused and Non-Fused Disconnects Specifications, Continued Fused Disconnect Switches For CSA HRCI-J and UL Class Fuses ➊ Electrical Ratings Cat. No. CSA Fuse Type/UL Fuse Type Maximum Fuse Cartridge Size (A) AC (V) Maximum Voltage DC (V) (A) Ampere Rating Maximum Short Circuit (kA) Prospective Fault Current Fuse Operating Characteristics Maximum HP, 3∅ AC 200V 60 Hz (HP) 230V 60 Hz (HP) 460V 60 Hz (HP) 575V 60 Hz (HP) Maximum HP, 1∅ AC 115V 60 Hz (HP) 230V 60 Hz (HP) Maximum HP, DC 125V DC (HP) 250V DC (HP) 194R-NC030P3 194R-NJ030P3 194R-NJ060P3 HRCI-MISC ➋/ Class CC 30 600 250 30 HRCI-J/ Class J 30 600 250 30 HRCI-J/ Class J 60 600 250 60 194R-NJ100P3 194R-NJ200P3 194R-NJ400P3 HRCI-J/ Class J 100 600 250 100 HRCI-J/ Class J 200 600 250 200 HRCI-J/ Class J 400 600 250 400 100 100 100 100 100 100 Time Delay NonTime Delay Time Delay NonTime Delay Time Delay NonTime Delay Time Delay NonTime Delay Time Delay NonTime Delay Time Delay NonTime Delay 5 5 10 10 3 3 5 7.5 7.5 7.5 15 20 3 3 5 7.5 15 15 30 50 7.5 7.5 15 15 25 30 60 75 15 15 25 30 50 60 125 150 25 25 50 60 100 125 250 300 50 50 100 125 0.75 2 0.5 1.5 2 3 0.5 1.5 3 10 1.5 3 7.5 15 — 7.5 — 25 — 15 — 50 — 25 2 3 2 3 3 5 2 5 5 10 5 10 — 20 — 20 — 40 — 40 — 50 — 50 Mechanical Data Cat. No. Degree of Protection (per IEC 947) Switch Only Switch with Terminal Shields & Fuse Cover(s) Operations Mechanical Endurance ➌ Operating Torque (Maximum) Nm Lb.-In. Terminal Capacity Power Terminals mm2 AWG mm2 AWG Maximum Number of Auxiliary Circuits kg. Approximate Weight Lbs. Minimum Enclosure Size Approximate dimensions in Height millimeters (inches) Width Depth Switch Dimension Reference (See dimension drawings on pages 4-87, 4-88, 4-89 and 4-90.) Auxiliary Contact Terminals 194R-NC030P3, 194R-NJ030P3 194R-NJ060P3 194R-NJ100P3 194R-NJ200P3 194R-NJ400P3 IP00 IP20 IP00 IP20 IP00 IP20 IP00 IP20 IP00 IP20 10,000 10,000 10,000 8,000 8,000 4 35 4 35 17.5 155 20.3 180 31.4 275 2.5…6 #14…#8 2.5…25 #14…#4 2.5…35 #14…#2 16…120 #6…250MCM Two 50…150 Two 1/0…350MCM 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 8 8 8 8 8 0.92 2.03 1.32 2.9 4.12 9.08 6.16 13.59 13.83 30.50 248 (9-3/4) 171 (6-3/4) 148 (5-13/16) 248 (9-3/4) 197 (7-3/4) 148 (5-13/16) 330 (13) 301 (11-27/32) 162 (6-3/8) 560 (22) 344 (13-17/32) 178 (7) 762 (30) 424 (16-45/64) 243 (9-9/16) A1 B1 C1 D1 F1 ➊ Only CSA Certified HRCI-J and HRCI-MISC (also UL Listed as Class CC) fuses and UL Listed Class J and CC fuses are suitable for use with these disconnect switches. ➋ CSA HRCI-MISC fuses must also be UL Listed as Class CC fuses. ➌ Based on Allen-Bradley tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 947-3, UL 1087 and UL 98. Product Selection — Page 4-64 Accessories — Page 4-69 Approximate Dimensions — Page 4-85 4-76 Bulletin 194R IEC Fused and Non-Fused Disconnects Specifications, Continued Non-Fused Disconnect Switches For CSA and UL Class Applications ➊ Electrical Ratings 194R-NN030P3 194R-NN060P3 194R-NN100P3 194R-NN200P3 194R-NN400P3 30 ➋ 60 ➋ 100 ➋ 200 ➋ 400 ➋ AC (V) DC (V) 600 250 600 250 600 250 600 250 600 250 (A) 30 60 100 200 400 Maximum Short Circuit Prospective (kA) Fault Current 100 100 100 100 100 Cat. No. Maximum Fuse Cartridge Size Maximum Voltage Ampere Rating Fuse Operating Characteristics ➌ Time Delay NonTime Delay Time Delay NonTime Delay Time Delay NonTime Delay Time Delay NonTime Delay Time Delay NonTime Delay Maximum HP, 3ý AC 200V 60 Hz (HP) 230V 60 Hz (HP) 460V 60 Hz (HP) 575V 60 Hz (HP) 7.5 7.5 15 20 3 3 5 7.5 15 15 30 50 7.5 7.5 15 15 25 30 60 75 15 15 25 30 50 60 125 150 25 25 50 60 100 125 250 300 50 50 100 125 Maximum HP, 1∅ AC 115V 60 Hz (HP) 230V 60 Hz (HP) 2 3 .5 1.5 3 10 1.5 3 — 15 — 7.5 — 25 — 15 — 50 — 25 125V DC (HP) 250V DC (HP) 3 5 2 5 5 10 5 10 — 20 — 20 — 40 — 40 — 50 — 50 Maximum HP, DC (W) Power Lost 2 6 20 40 80 Mechanical Data 194R-NN030P3 194R-NN060P3 194R-NN100P3 194R-NN200P3 194R-NN400P3 IP20 IP20 IP20 IP20 IP00 IP20 IP00 IP20 IP00 IP20 10,000 10,000 10,000 8,000 8,000 4 35 4 35 17.5 155 20.3 180 31.4 275 mm2 AWG 2.5…6 #14…#8 2.5…25 #14…#4 2.5…35 #14…#2 16…120 #6…250MCM Two 50…150 Two 1/ 0…350MCM mm2 AWG 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 2.5…4 #14…#12 Cat. No. Degree of Protection (per IEC 947) Switch Only Switch with Terminal Shields & Fuse Cover(s) Mechanical Endurance ➌ Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Operations Nm Lb.-In. Maximum Number of Auxiliary Circuits Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) kg. Lbs. Height Width Depth Switch Dimension Reference (See dimension drawings on pages 4-87, 4-88, 4-89 and 4-90.) 8 8 8 8 8 0.81 1.78 1.14 2.52 4.31 9.50 6.56 14.47 14.97 33.00 248 (9-3/4) 171 (6-3/4) 111 (4-3/8) 248 (9-3/4) 197 (7-3/4) 111 (4-3/8) 330 (13) 301 (11-27/32) 162 (6-3/8) 560 (22) 344 (13-17/32) 178 (7) 762 (30) 424 (16-45/64) 243 (9-9/16) A2 B2 C1 D1 F1 ➊ Non-fused disconnect switches must be used with separately installed CSA Certified HRCI-J, HRCI-T, or HRCI-MISC (also UL Listed as Class CC) fuses; or UL Listed Class J, CC or T fuses. ➋ When using CSA HRCI-J, HRCI-MISC (also UL Listed as Class CC) or HRCI-T fuses, and UL Class J, CC or T fuses. ➌ Based on Allen-Bradley tests in accordance with the requirements as defined in CSA C22.2 No. 4, IEC 947-3, UL 1087 and UL 98. Product Selection — Page 4-64 4-77 Bulletin 194R IEC Fused and Non-Fused Disconnects Specifications, Continued All Bulletin 194R Disconnect Switch Cat. Nos. Environmental Data Ambient Temperature Open ............................................................................. °C (F) Enclosed ..................................................................... °C (F) Storage ........................................................................ °C (F) Altitude (per IEC 947-1) –2…+55 (–4…+131) –20…+40 (–4…+104) –40…+65 (–40…+149) m 2,000 90% @ +20°C (+68°F) 50% @ +40°C (+104°F) Relative Humidity (per IEC 947-1) Auxiliary Contact Ratings for Cat. No. 195-GA AC11 Rating DC11 Rating Ue (Volts) le (Amperes) Ue (Volts) le (Amperes) 12…120 220…240 380…480 500…600 6 3 1.5 1.2 28 110 220 440 600 5.0 1.25 0.62 0.27 0.20 Thermal Current — 10 Amperes. EEMAC/NEMA A600, P300. Insulation Voltage IEC (Ui) — 660. Wiring Schematic L1 L2 L3 11 T1 T2 T3 12 LINE LOAD Product Selection — Page 4-64 4-78 Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Proper Selection of Disconnect Switches Applications Within Canada and the United States General The requirements for disconnect switches used in motor branch circuits rated 600V and less are defined in Article 430, Part J of the U.S. National Electrical Code (NEC), NFPA70. Canadian Electrical Code (CEC) requirements are very similar in the area of motor branch circuit disconnect requirements. For simplicity, we will treat the NEC and CEC requirements as being the same — and reference specific sections of the U.S. National Electrical Code. The requirements for properly sizing a disconnect switch are dependent on the type of application. The NEC refers to two types of applications: single motor and combination loads. A combination load consists of an application where two or more motors are used together or where one or more motors are used in combination with other loads, such as resistance heaters. started motors’ locked-rotor currents and the full-load currents of the remaining operating motor and non-motor loads. The disconnecting means shall have a current rating equal to or greater than 115% of the equivalent single motor full-load current and have a horsepower rating equal to or greater than the horsepower rating determined from the equivalent lockedrotor summation. Consider the following 460V application: Load HP 5 7.6 (simultaneous) Motor 2 10 14.0 (not included) ➊ Motor 3 15 21.0 (simultaneous) Motor 4 20 27.0 (simultaneous) Other 7.0 (simultaneous) Total Equivalent Single Motor Applications Section 430-110 Paragraph (a) states that the disconnect switch must have an ampere rating of at least 115% of the full-load current rating of the motor. Example 1: For a motor with a full-load current of 22 A, the disconnect switch must be rated at least 25.3 A (22 x 1.15). If the disconnecting means under evaluation is rated in horsepower, the selection of the disconnect switch is even more straightforward; a disconnect switch must have a horsepower rating equal to, or greater than the horsepower rating of the motor at the applicable voltage. Example 2: For a motor with a 10HP rating at 460V AC, the disconnect switch must be rated at least 10HP at 460V AC. If the disconnect switch is rated in horsepower, and UL Listed, UL Component Recognized, or CSA Certified, it will meet the requirements for the 115% full-load current rating stipulated by the NEC. Combination Load Applications Section 430-110 Paragraph (c) addresses the rating of the disconnecting means for combination loads. This paragraph essentially requires that the loads that “may be simultaneous on a single disconnecting means” be combined to provide equivalent full-load and locked-rotor currents for what is then to be considered as a single motor for the purpose of selecting the appropriate disconnecting means. This means that it is necessary to identify the particular combination of connected loads which can be operating simultaneously and will result in the maximum full-load and locked-rotor current sums. The individual full-load current values are to be selected from Tables 430-148, 430-149, or 430-150 and the locked-rotor values are to be from Table 430-151. The equivalent single motor full-load current is the sum of the simultaneously operating motor full-load currents and the rating in amperes of other loads operating at the same time. The equivalent locked-rotor current is the sum of the simultaneously Full-Load Current A Motor 1 62.6 (simultaneous) ➊ Motor 2 is not included in the total since it cannot operate simultaneously with the other motors, therefore, the disconnect switch must be rated at least 72 A (1.15 x 62.6). Consider now the locked-rotor current analysis for the same application: Load HP Full-Load Current A Motor 1 5 Motor 2 10 84.0 (not included) ➊ Motor 3 15 126.0 (simultaneous) ➋ Motor 4 20 162.0 (simultaneous) ➋ Other Total Equivalent (7.6FLA) 45.6 (simultaneous) 7.0 (simultaneous) 302.6 (simultaneous) ➊ Note again that Motor 2 cannot operate simultaneously with the other loads. ➋ The largest equivalent locked-rotor current occurs when motors 3 and 4 start together while the other loads marked “simultaneous” are already operating. Since Motor 1 is not starting with Motors 3 and 4, its full-load current will be added to the total instead of its locked-rotor current. Table 430-151, which provides the correlation between locked-rotor currents and HP ratings, shows that a 40 HP rating is the equivalent for 302.6 locked-rotor amperes. Therefore, the disconnect selected for this application must have a current rating of at least 72 A and a HP rating of at least 40 HP. In this case a Bulletin 194R rated for 100 A and 60 HP at 460V would be an appropriate choice. What can be seen from this analysis is that, depending upon the number of motors that can start simultaneously, the actual size of the required disconnect is sometimes determined by the equivalent full load current (72 A) and other times by the equivalent horsepower determined from the locked-rotor analysis (40 HP). Product Selection — Page 4-64 4-79 Bulletin 194R IEC Fused and Non-Fused Disconnects Proper Selection of Disconnect Switches, Continued Applications Outside the United States and Canada General Disconnect switches designed to IEC Standards and used in applications outside of North America are selected based on the ampere, horsepower, or kilowatt rating of the disconnect switch, under various utilization categories. Utilization categories for disconnect switches are as follows: Nature of Current AC Utilization Category Typical Applications Frequent Operation Infrequent Operation AC-20A ➊ AC-20B ➊ Connecting and disconnecting under no-load conditions AC-21A AC-21B Switching of resistive loads including moderate overloads AC-22A AC-22B Switching of mixed resistive and inductive loads, including moderate overloads AC-23A AC-23B Switching of motor loads or other highly inductive loads ➊ The use of these utilization categories is not permitted in the U.S. For any application, the disconnect switch ampere, horsepower, or kilowatt rating must be greater than, or equal to, the application full-load current or power (HP or kW), in the appropriate utilization category. Example 1: For a 380V 50 Hz distribution application (AC-22A), with a 63 A full load current, the disconnect switch must be rated at least 63 A at 380V 50 Hz for use in AC-22A applications. Example 2: For a 415V 50 Hz motor application (AC-23A), with a 75 kW rating, the disconnect switch must be rated at least 75 kW at 415V 50 Hz for use in AC-23A applications. Renewal Parts Hardware Kits (Includes switch/fuse mounting hardware and operating rod cotter pin) Disconnect Switch Cat. No. Dim. Ref. Cat. No. 194R-NH200P3 194R-ND250P3 194R-NB200P3 194R-NH100P3 194R-ND138P3 194R-NH400P3 194R-ND300P3 194R-NB300P3 194R-NN400P3 194R-NJ400P3 194R-NC030P3 194R-NJ030P3 194R-NN030P3 194R-NA100P3 194R-NA200P3 A1, A2 41022-316-02 41022-316-02 41022-316-02 41022-316-02 41022-316-02 194R-NJ060P3 194R-NN060P3 194R-NA300P3 B1, B2 41022-316-02 41022-316-02 41022-316-02 194R-NA380P3 194R-NN100P3 194R-NJ100P3 C1, C2 41022-800-03 41022-800-02 41022-800-01 194R-NA400P3 194R-NN200P3 194R-NJ200P3 194R-ND072P3 D1, D2 41022-800-07 41022-800-06 41022-800-05 41022-800-04 Product Selection — Page 4-64 4-80 Disconnect Switch Hardware Kit Part No. Dim. Ref. Hardware Kit Part No. E1, E2 41022-800-12 41022-800-11 41022-800-10 41022-800-09 41022-800-08 F1 41022-800-17 41022-800-16 41022-800-15 41022-800-14 41022-800-13 Bulletin 194R IEC Fused and Non-Fused Disconnects Fuse Description With Bulletin 194R Fused Disconnect Switches Bulletin 194R Fused Disconnect Switches have been designed to accept a variety of fuses for worldwide application flexibility. Following is a brief summary of typical fuse specifications, where the fuses are typically used, and which Bulletin 194R disconnect switches will accommodate each fuse type. Fuse manufacturers should be contacted for more specific information about each fuse type. Fuses are not available from Allen-Bradley. D K A BS88 Fuses (63 A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. • IEC fuse type: Fuse-link for bolted connection • Voltage rating: 660/690V AC • Interrupting rating: 80 kA • Standard cartridge sizes: A1, A2, A3, A4, B1, B2, B3, B4 • Typical ampere ratings: 2 A…400 A • Construction: Blade type for bolted connection • Can be installed on Bulletin 194R disconnect switch Cat. Nos: 194R-NA100P3, NA200P3, NA300P3, NA380P3, NA400P3, NB200P3, NB300P3 • Where used: United Kingdom, Australia, New Zealand, Asia B G H E Standard cartridge size A1 D D M F K F A B B A G G H E E H J J Standard cartridge sizes B1, B2, B3, B4 Standard cartridge sizes A2, A3, A4 Dim. Ref. F Ampere Range (A) A B D E F G H K A1 2…20 36.50 (1-7/16) 13.90 (35/64) 55.60 (2-3/16) 11.10 (7/16) 0.80 (1/32) 4.50 (1-3/4) 4.40 (11/64) 14.30 (9/16) Dim. Ref. Ampere Range (A) A B D E F G H J K A2 2…32 56.40 (2-7/32) 23.80 (15/16) 85.80 (3-3/8) 8.70 (11/32) 1.20 (3/64) 73.00 (2-7/8) 5.20 (13/64) 7.10 (9/32) 23.80 (15/16) A3 35…63 56.40 (2-7/32) 23.80 (15/16) 85.80 (3-3/8) 8.70 (11/32) 1.20 (3/64) 73.00 (2-7/8) 5.20 (13/64) 7.10 (9/32) 23.80 (15/16) A4 80…100 70.00 (2-3/4) 34.90 (1-3/8) 111.00 (4-3/8) 19.10 (3/4) 2.40 (3/32) 93.70 (3-11/16) 8.70 (11/32) 10.30 (13/32) 34.90 (1-3/8) Dim. Ref. Ampere Range (A) A B D E F G H J M B1 80…100 70.00 (2-3/4) 34.90 (1-3/8) 136.50 (5-3/8) 19.10 (3/4) 3.20 (1/8) 111.00 (4-3/8) 8.70 (11/32) 11.90 (15/32) 79.40 (3-1/8) B2 125…200 77.00 (3-1/32) 41.30 (1-5/8) 136.50 (5-3/8) 19.10 (3/4) 3.20 (1/8) 111.00 (4-3/8) 8.70 (11/32) 11.90 (15/32) 79.40 (3-1/8) B3 250…315 77.00 (3-1/32) 54.00 (2-1/8) 136.50 (5-3/8) 25.40 (1) 3.20 (1/8) 111.00 (4-3/8) 8.70 (11/32) 11.90 (15/32) 82.00 (3-1/4) B4 355…400 83.00 (3-9/32) 61.10 (2-13/32) 136.50 (5-3/8) 25.40 (1) 6.30 (1/4) 111.00 (4-3/8) 8.70 (11/32) 11.90 (15/32) 85.80 (3-3/8) Product Selection — Page 4-64 4-81 Bulletin 194R IEC Fused and Non-Fused Disconnects Fuse Description, Continued With Bulletin 194R Fused Disconnect Switches, Continued DIN Fuses (100 A shown) Dimensions in millimeters only. Dimensions are not intended to be used for manufacturing purposes. • IEC fuse type: Fuse-link with blade contacts • Voltage rating: 660/690V AC • Interrupting rating: 120,000 A • Standard cartridge sizes: 00, 0, 1 and 2 • Typical ampere ratings: 2…400 A • Construction: Blade type • Can be installed on Bulletin 194R disconnect switch Cat. Nos: 194R-ND072P3, ND138P3, ND250P3, ND300P3 • Where used: Europe, South America, Middle East and India e3 X ( 2 min.) a4 a3 , 10 – 0.3 d d 2.5 +0.5 e1 5 min. b c2 f a2 6-0.3 e4 a1 e2 Size Max. rated current (A) a1 a2 a3 a4 b (min.) d e1 (max.) e2 (max.) e3 e4 ±0.2 f 00 100 78.5 ±1.5 53 45 ±1.5 49 ±1.5 15 2 ±0.5 48 30 20 ±5 6 12.5 0 160 125 ±2.5 67 62 +3 –1.5 68 +1.5 –3 15 2 +1.5 –0.5 48 40 20 ±5 6 11.5 1 250 135 ±2.5 71 62 ±2.5 68 ±2.5 20 2.5 +1.5 –0.5 53 52 20 +5 –2 6 10 2 400 150 ±2.5 72 62 ±2.5 68 ±2.5 25 2.5 +1.5 –0.5 61 60 20 +5 –2 6 10 Product Selection — Page 4-64 4-82 Bulletin 194R IEC Fused and Non-Fused Disconnects Fuse Description, Continued With Bulletin 194R Fused Disconnect Switches, Continued CSA HRCI and UL Class Fuses (10 A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. • UL fuse type: Class CC • CSA fuse type: HRCI-MISC • Voltage rating: 600V AC • Interrupting rating: 200,000 A • Standard cartridge sizes: 30 A • Typical ampere ratings: 1…30 A 38.1 (11/2) • Construction: Ferrule type • Can be installed on Bulletin 194R disconnect switch Cat. No: 194R-NC030P3 9.5 (3/8) • Where used: North America CSA HRCI and UL Class Fuses (30 A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 9.5 (3/8) 3.2 (1/8) 60.3 (2-3/8) 57.1 (2-1/4) • CSA fuse type: HRCI-J 15.9 (5/8) 12.7 (1/2) • UL fuse type: Class J 6.4 (1/4) 17.5 (1-1/16) 20.6 (13/16) • Voltage rating: 600V AC 1A to 30A 35A to 60A • Interrupting rating: 200,000 A • Standard cartridge sizes: 30 A, 60 A, 100 A, 200 A and 400 A • Typical ampere ratings: 1 -600 A; Blade type for bolted connection 92 (3-5/8) 12.9 (1/2) 19 (3/4) 133 (5-1/4) 4.7 (3/16) 76.2 (3) 146 (5 3/4) 23.8 (15/16) 38.1 (1-1/2) 7.1 (9/32) 9.5 (3/8) 25.4 (1) 66.7 (2-5/8) 117. 5 (4-5/8) 110A to200A 28.6 (1-1/8) 7.1 (9/32) 9.5 (3/8) • Where used: North America 111.1 (4-3/8) 28.6 (1-1/8) 65A to100A • Can be installed on Bulletin 194R disconnect switch Cat. Nos: 194R-NJ030P3, NJ060P3, NJ100P3, NJ200P3, NJ400P3 17.5 (11/16) 3.2 (1/8) 34.9 (1-3/8) 41.3 (1-5/8) 225A to 400A 13.5 (17/32) 85.7 (3-3/8) 6.4 (1/4) 50.8 (2) 10.3 (13/32) 47.6 (1-7/8) 181 (7-1/8) Product Selection — Page 4-64 4-83 Bulletin 194R IEC Fused and Non-Fused Disconnects Fuse Description, Continued With Bulletin 194R Fused Disconnect Switches, Continued CSA HRCII Fuses (100 A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. • CSA fuse type: HRCII-C • Voltage rating: 600V AC • Interrupting rating: 200,000 A • Standard cartridge sizes: 30 A, 60 A, 100 A, 200 A and 400 A • Typical ampere ratings: 1…400 A • Construction: Blade type for bolted connection • Can be installed on Bulletin 194R disconnect switch Cat. Nos: 194R-NA200P3, NA300P3, NH100P3, NH200P3, NH400P3 • Where used: Canada F G F F G G G D E E C B A E H C B A D H H C B A J H D Standard Cartridge Sizes 100 A, 200 A and 400 A Standard Cartridge Sizes 30 A and 60 A Range (A) A B C D E F G H J 0…30 84.14 (3-5/16) 71.04 (2-51/64) 50.8 (2) 20.64 (13/16) 8.73 (11/32) 7.54 (19/64) 5.56 (7/32) 23.81 (15/16) 1.59 (1/16) 31…60 88.9 (3-1/2) 71.04 (2-51/64) 50.8 (2) 20.64 (13/16) 12.7 (1/2) 7.54 (19/64) 5.56 (7/32) 26.99 (1-1/16) 1.59 (1/16) 61…100 109.54 (4-5/16) 92.47 (3-41/64) 60.72 (2-25/64) 34.13 (1-11/32) 19.05 (3/4) 11.91 (15/32) 8.73 (11/32) 34.93 (1-3/8) 2.38 (3/32) 101…200 134.94 (5-5/16) 109.14 (4-19/64) 76.2 (3) 38.1 (1-1/2) 19.05 (3/4) 11.91 (15/32) 8.73 (11/32) 3.18 (1/8) — 201…400 207.96 (8-3/16) 133.35 (5-1/4) 76.2 (3) 60.33 (2-3/8) 25.4 (1) 12.7 (1/2) 9.53 (3/8) 25.4 (1) 4.76 (3/16) 401…600 207.96 (8-3/16) 133.35 (5-1/4) 76.2 (3) 76.2 (3) 25.4 (1) 15.08 (19/32) 10.32 (13/32) 25.4 (1) 9.53 (3/8) Product Selection — Page 4-64 4-84 E G Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Approximate Dimensions Disconnect Switches Disconnect Switch Dimension References A1, A2, B1 and B2 (30 A and 60 A) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Disconnect Switch Dimension Reference A1 A2 B1 B2 Approximate Dimensions H W D A B FD 106 (4-11/64) 106 (4-11/64) 118 (4-21/32) 118 (4-21/32) 102 (4-1/64) 102 (4-1/64) 134 (5-9/32) 134 (5-9/32) 112 (4-13/32) 83 (3-17/64) 115 (4-33/64) 83 (3-17/64) 82 (3-15/64) 82 (3-15/64) 100 (3-15/16) 100 (3-15/16) 85 (3-11/32) 82 (3-15/64) 120 (4-23/32) 120 (4-23/32) 2-M4 2-#8 2-M4 2-#8 4-M4 4-#8 4-M4 4-#8 Disconnect Switch Dimension References C1, C2, D1, D2, E1, E2 and F1 (100 A, 200 A and 400 A) Disconnect Switch Dimension Reference C1 C2 D1 D2 E1 E2 F1 Approximate Dimensions H W D A B FD 148 (5-53/64) 148 (5-53/64) 184 (7-1/4) 184 (7-1/4) 220 (8-21/32) 220 (8-21/32) 250 (9-27/32) 194 (7-41/64) 194 (7-41/64) 236 (9-19/64) 236 (9-19/64) 278 (10-15/16) 278 (10-15/16) 308 (12-1/8) 130 (5-7/64) 136 (5-23/64) 148 (5-53/64) 153 (6-1/64) 213 (8-25/64) 213 (8-25/64) 213 (8-25/64) 106 (4-11/64) 106 (4-11/64) 106 (4-11/64) 106 (4-11/64) 150 (5-29/32) 150 (5-29/32) 150 (5-29/32) 170 (6-11/16) 170 (6-11/16) 212 (8-11/32) 212 (8-11/32) 252 (9-59/64) 252 (9-59/64) 282 (11-7/64) 4-M6 (4-1/4) 4-M6 (4-1/4) 4-M6 (4-1/4) 4-M6 (4-1/4) 4-M8 (4-5/16) 4-M8 (4-5/16) 4-M8 (4-5/16) Product Selection — Page 4-64 4-85 Bulletin 194R IEC Fused and Non-Fused Disconnects Approximate Dimensions, Continued Operating Handles — Cat. No. 194R-HS.../190-HS Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 50 (1-31/32) ON 25 (63/64) 76.2 (3) O F F 25 (63/64) 35 (1.375 dia.) 50 (1-31/32) 76.2 (3) 40.3 (1-19/32) 18.4 (23/32) 2 – 5.5 mm (4 –.219dia.) Operating Handles — Cat. No. 194R-HM.../190-HM 75 (2-61/64) 37.5 (1-15/32) 37.5 (1-15/32) 65 (2-9/16 dia.) 75 (2-61/64) 4 – 5.5 (4 7/32 dia.) Product Selection — Page 4-64 4-86 Bulletin 194R IEC Fused and Non-Fused Disconnects Approximate Dimensions, Continued Disconnect Switch Dim. Ref.: A1, A2, B1, B2 (30 A and 60 A) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 25 (63/64) 1 Two(2) - M4 2.0 N . m 18 lb-in. 50 (1-31/32) Two (2) – 5.5 (.219 dia.) 35 (1.38 dia.) 50 (1-31/32) 25 (63/64) Cat. No.194R-NA100P3 (SER.B) Cat. No.194R-NA200P3 (SER.B) Cat. No.194R-NC030P3 (SER.B) Cat. No. 194R-NJ030P3 (SER.B) Cat. No.194R-NN030P3 (SER.B) 1 Four (4)-M4 2.0N .m 18 lb-in. Cat. No.194R-NA300P3 (SER. B) Cat. No. 194R-NJ060P3 (SER. B) Cat. No.194R-NN060P3 (SER. B) Disconnect Switch and Operating Handle Installation Dimensions ➊ The switch is capable of accepting #8 screws 34.9 (1-3/8) for mounting. Note: Enclosure Installation Dimensions A through F are listed on page 4-88. Cat. No. (SER. B) Dim. Ref. G H J A1, A2 85 (3-11/32) 7.5 (19/64) 24.2 (61/64) B1, B2 120 (4-23/32) 10 (25/64) 28.5 (1-1/8) K L M N 64.8 41 (2-35/64) (1-39/64) 129.6 (5-7/64) 11.8 (15/32) 76.5 (3-1/64) 153 (6-1/32) 17.5 (11/16) P Q R S T U 106 82 (4-11/64) (3-15/64) 102 (4-1/64) 114.1 (4-1/2) 126.2 (4-31/32) 12 (15/32) 118 100 (4-21/32) (3-15/16) 134 (5-9/32) 146.1 (5-3/4) 158.2 (6-15/64) 16 (5/8) 194R-NA100P3 194R-NA200P3 194R-NC030P3 194R-NJ030P3 194R-NN030P3 194R-NA300P3 194R-NJ060P3 50 (1-31/32) 194R-NN060P3 Product Selection — Page 4-64 4-87 Bulletin 194R IEC Fused and Non-Fused Disconnects Approximate Dimensions, Continued Disconnect Switch Dim. Ref.: A1, A2, B1, B2 (30 A and 60 A) Enclosure and Operating Handle Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 40.3 (1-19/32) Enclosure Installation Dimensions Cat. No. Dim. Ref. A B D E Maximum Minimum Minimum C Maximum Minimum Minimum Minimum F Maximum 194R-NA100P3 (SER. B) 194R-NA200P3 (SER. B) 194R-NC030P3 (SER. B) 194R-NJ030P3 (SER. B) A1 171 (6-3/4) 45 (1-49/64) 147.6 (5-13/16) 454 (17-7/8) 248 (9-3/4) 89 (3-1/2) 1.4 (1/16) 4.78 (3/16) 194R-NN030P3 (SER. B) A2 171 (6-3/4) 45 (1-49/64) 111 (4-3/8) 454 (17-7/8) 248 (9-3/4) 89 (3-1/2) 1.4 (1/16) 4.78 (3/16) 194R-NA300P3 (SER. B) 194R-NJ060P3 (SER. B) B1 197 (7-3/4) 45 (1-49/64) 147.6 (5-13/16) 454 (17-7/8) 248 (9-3/4) 105 (4-9/64) 1.4 (1/16) 4.78 (3/16) 194R-NN060P3 (SER. B) B2 197 (7-3/4) 45 (1-49/64) 111 (4-3/8) 454 (17-7/8) 248 (9-3/4) 105 (4-9/64) 1.4 (1/16) 4.78 (3/16) Product Selection — Page 4-64 4-88 Bulletin 194R IEC Fused and Non-Fused Disconnects Approximate Dimensions, Continued Disconnect Switch Dim. Ref.: C1, C2, D1, D2 (100 A and 200 A) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Four (4)-M6 x 12 1 4.0 N.m 35lb-in 75 (2-61/64) Four (4) – 5.5 (.219 dia.) 140 (5-33/64) 37.5 (1-15/32) 65 (2-9/16 dia.) 75 (2-61/64) 37.5 (1-15/32) 58 (2-9/32) ➊ The switch is capable of accepting four (4)∅ 6.4 (1/4 dia.) screws for mounting. Enclosure Installation Dimensions A Dimension Reference B C H T W Minimum Minimum Minimum Minimum Maximum Minimum Minimum Maximum Single Pole Aux. Cont. Two Pole Aux. Cont. C1 108 (4-1/4) 162 (6-3/8) 162 (6-3/8) 457 (18) 330 (13) 1.6 (1/16) 4.8 (3/16) 301 (11-27/32) 313 (12-5/16) C2 108 (4-1/4) 162 (6-3/8) 168 (6-5/8) 457 (18) 330 (13) 1.6 (1/16) 4.8 (3/16) 301 (11-27/32) 313 (12-5/16) D1 108 (4-1/4) 280 (11) 178 (7) 457 (18) 560 (22) 1.6 (1/16) 4.8 (3/16) 344 (13-17/32) 356 (14) D2 108 (4-1/4) 280 (11) 183 (7-7/32) 457 (18) 560 (22) 1.6 (1/16) 4.8 (3/16) 344 (13-17/32) 356 (14) Disconnect Switch and Operating Handle Installation Dimensions Dimension Reference D E F G J K L M N P Q C1, C2 74 (2-29/32) 53 (2-3/32) 106 (4-3/16) 170 (6-11/16) 148 (5-53/64) 176 (6-15/16) 88 (3-15/32) 13.5 (17/32) 12.7 (1/2) 194 (7-41/64) 206 (8-7/64) D1, D2 162 (6-23/64) 53 (2-3/32) 106 (4-3/16) 212 (8-11/32) 184 (7-1/4) 236 (9-9/32) 118 (4-41/64) 26 (1-1/32) 12.7 (1/2) 236 (9-19/64) 248 (9-49/64) Product Selection — Page 4-64 4-89 Bulletin 194R IEC Fused and Non-Fused Disconnects Approximate Dimensions, Continued Disconnect Switch Dim. Ref.: E1, E2, F1 (200 A and 400 A) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Four (4)–M8x1.25 1 6.0N .m 55lb-in Four (4)– 5.5 (.219 dia.) 65 (2-9/16 dia.) ➊ The switch is capable of accepting four (4)∅ 7.9 (5/16 dia.) screws for mounting. Enclosure Installation Dimensions A Dimension Reference B C H T W Minimum Minimum Minimum Minimum Maximum Minimum Minimum Maximum Single Pole Aux. Cont. Two Pole Aux. Cont. E1 108 (4-1/4) 305 (12) 227 (8-15/16) 610 (24) 610 (24) 1.6 (1/16) 4.8 (3/16) 394 (15-33/64) 406 (16) E2 108 (4-1/4) 356 (14) 227 (8-15/16) 610 (24) 712 (28) 1.6 (1/16) 4.8 (3/16) 394 (15-33/64) 406 (16) F1 108 (4-1/4) 381 (15) 243 (9-9/16) 610 (24) 762 (30) 1.6 (1/16) 4.8 (3/16) 606 (23-7/8) 606 (23-7/8) Disconnect Switch and Operating Handle Installation Dimensions Dimension Reference D E F G J E1 158 (6-7/32) 75 (2-61/64) 150 (5-29/32) 252 (9-59/64) 220 (8-21/32) E2 209 (8-7/32) 75 (2-61/64) 150 (5-29/32) 252 (9-59/64) F1 202 (7-61/64) 75 (2-61/64) 150 (5-29/32) 282 (11-7/64) Product Selection — Page 4-64 4-90 K L M N P Q 294 147 (11-37/64) (5-25/32) 37 (1-29/64) 14 (35/64) 278 (10-15/16) 290 (11-13/32) 220 (8-21/32) 294 147 (11-37/64) (5-25/32) 37 (1-29/64) 14 (35/64) 278 (10-15/16) 290 (11-13/32) 250 (9-27/32) 358 (14-3/32) 54 (2-1/8) 14 (35/64) 308 (12-1/8) 320 (12-19/32) 179 (7-3/64) Bulletin 194R IEC Fused and Non-Fused Disconnects Approximate Dimensions, Continued IP66 (Type 3/4/12) Watertight, Dusttight Sheet Metal Enclosure Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. External Mounting Feet Optional Cat. No. 198-F1 (A) Type Dim. Ref. A B C D E F G H 30 Non-Fused & Fused A1 & A2 200 (7-7/8) 300 (11-13/16) 160 (6-19/64) 200 (7-7/8) 325 (12-51/64) 313 (12-21/64) 105 (4-1/8) 236 (9-9/32) 60 Non-Fused & Fused B1 & B2 200 (7-7/8) 300 (11-13/16) 160 (6-19/64) 200 (7-7/8) 325 (12-51/64) 313 (12-21/64) 105 (4-1/8) 236 (9-9/32) 100 Non-Fused & Fused C1 400 (15-3/4) 350 (13-25/32) 180 (7-3/32) 220 (8-21/32) 375 (14-3/4) 363 (14-19/64) 206 (8-1/8) 286 (11-1/4) External Mounting Feet Optional Cat. No. 198-F3 (A) Type Dim. Ref. A B C D E F G H 200 Non-Fused & Fused D1 406 (16) 610 (24) 224 (8-51/64) 282 (11-5/64) 688 (27-5/64) 648 (25-1/2) 368 (14-1/2) 572 (22-1/2) 400 Non-Fused & Fused F1 610 (24) 762 (30) 326 (12-51/64) 384 (15-5/64) 840 (33-5/64) 800 (31-1/2) 572 (22-1/2) 724 (28-1/2) Product Selection — Page 4-64 4-91 Bulletin 194R IEC Fused and Non-Fused Disconnects Approximate Dimensions, Continued Type 4/4X Watertight, Corrosion-Resistant Stainless Steel Enclosure Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. External Mounting Feet Standard External Mounting Feet Optional Cat. No. 198-F3 (A) Type Dim. Ref. A A1 B C D E F G H Non-Fused A2 159 (6-1/4) 170 (6-11/16) 240 (9-7/16) 123 (4-27/32) 163 (6-7/16) 273 (10-3/4) 254 (10) 83 (3-1/4) – Fused A1 214 (8-7/16) 225 (8-7/8) 265 (10-7/16) 125 (4-29/32) 165 (6-1/2) 298 (11-23/32) 229 (11) 83 (3-1/4) – Non-Fused & Fused B1 & B2 214 (8-7/16) 225 (8-7/8) 265 (10-7/16) 125 (4-29/32) 165 (6-1/2) 298 (11-23/32) 229 (11) 83 (3-1/4) – 30 60 External Mounting Feet Optional Cat. No. 198-F3 (A) Type Dim. Ref. A A1 B C D E F G H 100 Non-Fused & Fused C1 508 (20) – 406 (16) 224 (8-51/64) 282 (11-7/64) 484 (19-5/64) 444 (17-1/2) 470 (18-1/2) 368 (14-1/2) 200 Non-Fused & Fused D1 406 (16) – 610 (24) 224 (8-51/64) 282 (11-5/64) 688 (27-5/64) 648 (25-1/2) 368 (14-1/2) 572 (22-1/2) 300 Non-Fused & Fused F1 610 (24) – 762 (30) 326 (12-51/64) 384 (15-5/64) 840 (33-5/64) 800 (31-1/2) 572 (22-1/2) 724 (28-1/2) Product Selection — Page 4-64 4-92 Bulletin 194R IEC Fused and Non-Fused Disconnects Approximate Dimensions, Continued IP66 (Type 3/4/4X/12) Corrosion Resistant, Non-Metallic Enclosure Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. K 6 (15/64) A H D C J F B (4)-.31 X .50 SLOT MTG. HOLES (8) (13) G 32 (1-1/4) Cat. No. 194R-K_30P3, 194R-K_60P3 30 and 60 A Switch K 5 (3/16) A H D C F B J G 32 (1-9/32) (4)-.31 X .50 SLOT MTG. HOLES (8) (13) Cat. No. 194R-K_100P3 100 A Switch Switch Size (A) A B C D F G H J K 30/60 226 (8-59/64) 267 (10-1/2) 163 (6-27/64) 202 (7-61/64) 278 (10-61/64) 152 (6) 216 (8-1/2) 305 (12) 6 (15/64) 100 379 (14-15/16) 420 (16-1/4) 215 (8-31/64) 273 (10-49/64) 430 (16-61/64) 305 (12) 370 (14-9/16) 457 (18) 5 (13/64) Product Selection — Page 4-64 4-93 Bulletin 194R IEC Fused and Non-Fused Disconnects Approximate Dimensions, Continued IP66 (Type 3/4/4X/12) Corrosion Resistant, Non-Metallic Enclosure, Continued Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. K 11 (29/64) F D A C B J (4)-.41 DIA. MTG. HOLES (10) G Cat. No. 194R-K_200P3 200 A Switch K 11 (27/64) D C A B F J (4)-.41 DIA. MTG. HOLES (10) G Cat. No. 194R-K_400P3 400 A Switch Switch Size (A) A B C D F G J K 200 513 (20-13/64) 625 (24-5/8) 292 (11-31/64) 350 (13-25/32) 648 (25-1/2) 457 (18) 686 (27) 11 (7/16) 400 612 (24-1/8) 775 (30-33/64) 342 (13-31/64) 401 (15-25/32) 796 (31-11/32) 555 (21-7/8) 834 (32-27/32) 11 (27/64) Product Selection — Page 4-64 4-94