C2O CALL ‘2’ OPEN USING YOUR CELL PHONE Features Ready to operate Straight from the Box! O/P Changeover Contact 1.2KW ‘White List’ upto 10 Tel No’s Signal Strength Indication Internal Antenna Waterproof Enclosure IP68 (Pressure Washer Proof) Accepts all major SIM Cards 9-24Vdc Operation Optional Battery Backup Optional Configuration by SMS Text Messages Easy Operation 1. User Calls C2O 2. C2O Rejects call 3. If valid C2O operates Output Operation Call ‘2’ Open provides a relay changeover contact which can operate gates / barriers etc. When C2O receives a telephone call, the relay contacts are operated. Because C2O rejects the call no call charges are incurred. C2O can operate from any Tel number, or, from only those with Caller ID on the ‘White list’ DS-C2O-5 Manufactured in UK C2O 1. Insert Simcard Insert SIM card before applying power (standard 3 Volt SIM cards only). Ensure simcard is blank Insert Simcard Here Ensure the Simcard has not been PIN Code Protected! Beware of pay-as-you-go SIM cards which require regular call activity to remain active. RF Solutions recommends O2 / Vodafone. Problems have been identified with Orange SIM cards which cannot be guaranteed Changeover Contact Terminals Power Connection 9-24Vdc 2. LED Indication at Startup Loging onto Network (Tx/Rx alternate flash) RX TX Error! (All Flash ON / OFF together) 30 20 10 RX TX Error - No GSM Service 1. Check SimCard 2. Check Antenna Connection 3. LED Indication after Startup (Normal Operation) Signal Strength Good OK Poor DS-C2O-3 DS-C2O-5 Activity LED’s RX Page 2 Receiving an SMS TX Transmitting an SMS GSM Intermittent Flash GSM Healthy C2O Optional Waterproof Power Supply Resin Potted Unit (IP67) Size 83 x 37 x 30mm Input 100-240Vac Output 12Vdc 1A Wall Fixing Lugs Supplied with 3.3m lead Part NO PSU-12V1A-IP Optional External Antenna Using an external antenna can provide a better signal reception than the internal antenna if required. Using Cable adaptor CBA-UFLSMA-1 provides an SMA Bulkhead connector into which many alternative GSM antennas may connect Antenna Connection Cable Part No: CBA-UFLSMA-1 Ordering Information DS-C2O-3 PART No Description C2O Call2Open Controller IP68 PSU-12V1A-IP Power Supply IP67 CBA-UFLSMA Cable assy for external Antenna DS-C2O-5 Page 3 Integral Antenna C2O Sending Text Commands (These are optional) Command Description The default password is 1234 .it can be changed to any combination of letters/numbers from 4 to 10 characters. Unit Password (UPW) This command that must be sent within 5minutes from initial power up. If for any reason the unit password is lost or miss-entered, remove all power to the unit for 1 minute, then start again. Command Example: UPW#1234 (Sets the password to 1234) Response: Unit Password Set ***NOTE ONLY THIS COMMAND IS CASE SENSITIVE!*** Change Output delay time (OPDLY1) Unit Identity (UID) Report GSM Signal Strength (SIGQ) DS-C2O-3 By default this is preset to 1 Second operation Command Example: 1234#OPDLY1#2 (Sets the changeover contacts to operate for 2 seconds) The time of the output can be set from 1 to 65500 seconds, or If is set to ‘0’, then the output will latch on. This sets the ‘identity’ of the C2O unit, and is included in any response text from the C2O Command Example : Password#UID#Gate2 Sets the identity of this C2O to Gate2 Reports C2O GSM signal strength as; ‘POOR’ (consider alternative antenna) ‘OK’, or ‘Good’ Command Example : Password#SIGQ Response : Signal is Good DS-C2O-5 Page 4 C2O Additional Commands for using the White List Command Description Adds a telephone number (caller ID) to the white list that C2O will accept. Add Tel No to White List (C2ONUM) Note the C2O can store up to 10 cell phone numbers per input. Setting * as a number will allow any number access Command Example: 1234#C2ONUM#1#* (Allows any telephone to activate C2O) Command Example: 1234#C2ONUM#1#0123457891 (Adds the telephone no 01234 57891 to position 1 of the white list) Report the White List Report C2O White List of Telephone numbers which are accepted Command Example: 1234#C2ONUM? (C2ONUM?) Delete a number in the White List (C2ONUMDELn) DS-C2O-3 DS-C2O-5 This command Deletes a telephone numbers within the White list Command Example: 1234#C2ONUMDEL#1 Deleted telephone number in position 1 of the list Page 5 C2O Technical Specifications Storage Temperature: C2O Enclosure Rating C2O Dimensions -10 to +70o Celsius. Operating Temperature: 0 to +55o Celsius. IP68 130 x 112 x 42mm Electrical Characteristics Min Supply Voltage 11 Supply Current for C2O: Idle Operating Mains rated Relay Rating (230Vac) 35 200 Typical Max Dimension Notes 24 Vdc 44 370 100 1000 mA mA 1 2 5 12 A 3 Notes 1. Refers to maximum supply current required with all components idle. 2. Refers to peak supply current required with all components operating. In practice internal reservoir capacitance limits the instantaneous peak current to less than 500 mA. 3. The relay contacts in this unit are for functional switching only and must not be used for isolation purposes. RF Solutions Ltd., William Alexander house, William way, Burgess Hill, W. Sussex. RH15 9AG. England. [email protected] http://www.rfsolutions.co.uk Tel: +44 (0)1444 227 000 Fax: +44 (0)1444 227 898 Disclaimer: Whilst the information in this document is believed to be correct at the time of issue, R.F.Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or completeness. No express or implied warranty or representation is given relating to the information contained in this document. R.F.Solutions Ltd reserves the right to make changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or products for their own particular requirements or specification(s). R.F.Solutions Ltd shall not be liable for any loss or damage caused as a result of user’s own determination of how to deploy or use R.F.Solutions Ltd’s products. Use of R.F.Solutions Ltd products or components in life support and/or safety applications is not authorised except with express written approval. No licences are created, implicitly or otherwise, under any of R.F.Solutions Ltd’s intellectual property rights. Liability for loss or damage resulting or caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where R.F.Solutions Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict R.F.Solutions Ltd’s liability for death or personal injury resulting from its negligence.