CALL `2` OPEN USING YOUR CELL PHONE

C2O
CALL ‘2’ OPEN USING YOUR CELL PHONE
Features
Ready to operate Straight from
the Box!
O/P Changeover Contact 1.2KW
‘White List’ upto 10 Tel No’s
Signal Strength Indication
Internal Antenna
Waterproof Enclosure IP68
(Pressure Washer Proof)
Accepts all major SIM Cards
9-24Vdc Operation
Optional Battery Backup
Optional Configuration by SMS
Text Messages
Easy Operation
1.
User Calls C2O
2.
C2O Rejects call
3.
If valid C2O operates Output
Operation
Call ‘2’ Open provides a relay changeover contact which can operate gates / barriers
etc. When C2O receives a telephone call, the relay contacts are operated.
Because C2O rejects the call no call charges are incurred.
C2O can operate from any Tel number, or, from only those with Caller ID on the
‘White list’
DS-C2O-5
Manufactured in UK
C2O
1. Insert Simcard
Insert SIM card before applying power
(standard 3 Volt SIM cards only).
Ensure simcard is blank
Insert
Simcard
Here
Ensure the Simcard has not been PIN Code
Protected!
Beware of pay-as-you-go SIM cards which
require regular call activity to remain active.
RF Solutions recommends O2 / Vodafone.
Problems have been identified with Orange
SIM cards which cannot be guaranteed
Changeover
Contact
Terminals
Power
Connection
9-24Vdc
2. LED Indication at Startup
Loging onto Network
(Tx/Rx alternate flash)
RX
TX
Error!
(All Flash ON / OFF together)
30
20
10
RX
TX
Error - No GSM Service
1. Check SimCard
2. Check Antenna Connection
3. LED Indication after Startup (Normal Operation)
Signal Strength
Good OK Poor
DS-C2O-3
DS-C2O-5
Activity LED’s
RX
Page 2
Receiving an SMS
TX
Transmitting an SMS
GSM
Intermittent Flash GSM Healthy
C2O
Optional Waterproof Power Supply
Resin Potted Unit (IP67)
Size 83 x 37 x 30mm
Input 100-240Vac Output 12Vdc 1A
Wall Fixing Lugs
Supplied with 3.3m lead
Part NO PSU-12V1A-IP
Optional External Antenna
Using an external antenna can provide a better signal reception than the internal antenna if
required. Using Cable adaptor CBA-UFLSMA-1 provides an SMA Bulkhead connector into
which many alternative GSM antennas may connect
Antenna
Connection
Cable Part No:
CBA-UFLSMA-1
Ordering Information
DS-C2O-3
PART No
Description
C2O
Call2Open Controller IP68
PSU-12V1A-IP
Power Supply IP67
CBA-UFLSMA
Cable assy for external Antenna
DS-C2O-5
Page 3
Integral
Antenna
C2O
Sending Text Commands (These are optional)
Command
Description
The default password is 1234 .it can be changed to any combination of
letters/numbers from 4 to 10 characters.
Unit Password
(UPW)
This command that must be sent within 5minutes from initial power up.
If for any reason the unit password is lost or miss-entered, remove all
power to the unit for 1 minute, then start again.
Command Example: UPW#1234
(Sets the password to 1234)
Response:
Unit Password Set
***NOTE ONLY THIS COMMAND IS CASE SENSITIVE!***
Change Output
delay time
(OPDLY1)
Unit Identity
(UID)
Report GSM
Signal Strength
(SIGQ)
DS-C2O-3
By default this is preset to 1 Second operation
Command Example: 1234#OPDLY1#2
(Sets the changeover contacts to operate for 2 seconds)
The time of the output can be set from 1 to 65500 seconds, or If is
set to ‘0’, then the output will latch on.
This sets the ‘identity’ of the C2O unit, and is included in any response
text from the C2O
Command Example : Password#UID#Gate2
Sets the identity of this C2O to Gate2
Reports C2O GSM signal strength as;
‘POOR’ (consider alternative antenna)
‘OK’, or ‘Good’
Command Example : Password#SIGQ
Response : Signal is Good
DS-C2O-5
Page 4
C2O
Additional Commands for using the White List
Command
Description
Adds a telephone number (caller ID) to the white list that C2O will
accept.
Add Tel No to White
List
(C2ONUM)
Note the C2O can store up to 10 cell phone numbers per input.
Setting * as a number will allow any number access
Command Example: 1234#C2ONUM#1#*
(Allows any telephone to activate C2O)
Command Example: 1234#C2ONUM#1#0123457891
(Adds the telephone no 01234 57891 to position 1 of the white list)
Report the White
List
Report C2O White List of Telephone numbers which are accepted
Command Example: 1234#C2ONUM?
(C2ONUM?)
Delete a number in
the White List
(C2ONUMDELn)
DS-C2O-3
DS-C2O-5
This command Deletes a telephone numbers within the White list
Command Example: 1234#C2ONUMDEL#1
Deleted telephone number in position 1 of the list
Page 5
C2O
Technical Specifications
Storage Temperature:
C2O Enclosure Rating
C2O Dimensions
-10 to +70o Celsius. Operating Temperature: 0 to +55o Celsius.
IP68
130 x 112 x 42mm
Electrical Characteristics
Min
Supply Voltage
11
Supply Current for C2O:
Idle
Operating
Mains rated Relay Rating
(230Vac)
35
200
Typical
Max
Dimension
Notes
24
Vdc
44
370
100
1000
mA
mA
1
2
5
12
A
3
Notes
1. Refers to maximum supply current required with all components idle.
2. Refers to peak supply current required with all components operating. In practice internal reservoir capacitance
limits the instantaneous peak current to less than 500 mA.
3. The relay contacts in this unit are for functional switching only and must not be used for isolation purposes.
RF Solutions Ltd.,
William Alexander house, William way,
Burgess Hill, W. Sussex. RH15 9AG. England.
[email protected]
http://www.rfsolutions.co.uk
Tel: +44 (0)1444 227 000 Fax: +44 (0)1444 227 898
Disclaimer:
Whilst the information in this document is believed to be correct at the time of issue, R.F.Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy
or completeness. No express or implied warranty or representation is given relating to the information contained in this document. R.F.Solutions Ltd reserves the right to
make changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such
information or products for their own particular requirements or specification(s). R.F.Solutions Ltd shall not be liable for any loss or damage caused as a result of user’s
own determination of how to deploy or use R.F.Solutions Ltd’s products. Use of R.F.Solutions Ltd products or components in life support and/or safety applications is not
authorised except with express written approval. No licences are created, implicitly or otherwise, under any of R.F.Solutions Ltd’s intellectual property rights. Liability for
loss or damage resulting or caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where
R.F.Solutions Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict R.F.Solutions Ltd’s liability for death or
personal injury resulting from its negligence.