High Voltage Test Set - Communications & Power Industries

Test Equipment
High Voltage Test Set
Helps Maximize Operating Life
The High Voltage (HV) Test Set is a portable, self-powered,
precision instrument for monitoring and calibrating all system
TWT or Klystron/Power Supply voltages. It is essential
that on-going verifi cation and calibration of tube operating
voltages be made as part of routine preventive maintenance
and repair procedures to maximize the operating life of the
tube. The HV Test Set can be used where the system does not
provide such measurements, or when the voltages require
precise adjustment.
The HV Test Set uses precision HV dividers to reduce the tube
voltages to safe operating levels (less than 20 VDC). These
low voltages can be measured with a digital volt meter at
test points located on the front panel of the Breakout Box.
The HV Test Set includes an isolated, digital volt meter in the
Breakout Box for safe, direct HV Test Set
For verifi cation and calibration of TWT and Klystron operating voltages measurement of the TWT fi lament (heater)
voltage. The precise setting and maintenance of this voltage
is critical for maximizing tube life.
Klystron Test Set
For calibration and verification of TWT
and klystron operating voltages
HIGH VOLTAGE TEST SET INCLUDES
•Breakout Box
•High Voltage Cables
•Filament Load Resistor Assembly/Test
Plug or Calibration Module
•Operator’s Manual
•Carrying Case
Worldwide Support
Backed by over three decades of satellite communications
experience, and CPI’s worldwide 24-hour customer support
network that includes more than twenty regional factory
service centers.
811 Hansen Way, PO Box 51625
Palo Alto, CA 94303 USA
tel:
+1 (650) 846-3803
fax:
+1 (650) 424-1744
e-mail:[email protected]
website:www.cpii.com/satcom
Test Equipment
Specifications High Voltage Test Set
High Voltage Test Set Components
The breakout box is the key component of the test set.
It is a self-contained amplifier voltage measurement device
contained in an environmentally sealed package. The unit
consists of monitoring circuits for all traveling wave tube
(TWT) or klystron electrode voltages. The test points on the
face of the box are banana plug receptacles for use with a
conventional digital volt meter.
High voltage interconnect cables provide secure connections
between the Breakout Box and the HPA being tested. All
HPAs use two high voltage interconnect cables, except the
3 kW TWTA (one), the Millitron (three), the VSTAR 30 (five)
and the millimeter wave J-Rack (five).
A filament load resistor assembly, a test plug, or a
calibration module can be used to calibrate and monitor the
power supply without a TWT or RF drawer.
An operation manual and carrying case are included with
each HV Test Set.
SPECIFICATIONS
OPERATING CONDITIONS
Maximum Voltage
15 kVDC
Maximum Current
7.5 amps
Altitude
Sea level to 10,000 ft
Temperature
0°C to +50°C
MECHANICAL
Breakout Box
Weight
Dimensions
Case, High Voltage Set and Manual
Weight
Dimensions
Page 2 of 4 MKT-60 ISSUE 7
7 lbs (3.18 kg)
7.7 x 6.3 x 6.8 inches
(195.6 x 160 x 96.5 mm)
20 lbs max. (9.1 kg)
19.5 x 15 x 9 inches
(469.9 x 381 x 228.6 mm)
C-Band / Ku-Band
Part Number Matrix
High Voltage Test Set
Product
HV Test Set
Breakout
Box
Cable Assy,
High VoltFilament
age Inter- Load Resisconnect
tor Assy
Calibration
Module
Carrying
Case
Manual
Single Drawer 200400W Rack,
500-750W ODUs,
M-band J-Rack
01022894-00
01020673-00
01020681-00
01020682-00
01022898-00
NOT
REQUIRED
01026110-00
01026664
Single Drawer 500750W Rack, L- and
S/C-band J-Racks
01022894-01
01020673-00
01020681-00
01020682-00
01022898-00
NOT
REQUIRED
01026110-00
01026664
2-drawer "F Series"
300-750 W TWTAs
01022895-00
01020673-00
01020683-00
01020684-00
01022898-02
NOT
REQUIRED
01026110-00
01026664
2-drawer 2.25 kW
TWTAs (C- and
X-band)
01022892-00
01020673-00
01020675-00
01020676-00
01022898-00
NOT
REQUIRED
01026110-00
01026664
125 W Ku-band Outdoor Unit (ODU)
01027464-00
01020673-00
01027462-00
01027463-00
01022898-02
NOT
REQUIRED
01026110-00
01026664
GEN IV Klystron HPA
01027825-00
01020673-01
01027823-00
01027824-00
01020798-00
01027822-00
NOT
REQUIRED
01026110-00
01026664
200 W Ku-band ODU
01035319-00
01020673-00
01020687-00
01020688-00
01022898-02
NOT
REQUIRED
01026110-00
01026664
250 Ka-band TWTA
ODU (with NEC TWT)
01035299-00
01020673-00
01020679-01
01020680-01
01022898-02
NOT
REQUIRED
01026110-00
01026664
500 Ka-band TWTA
ODU (Thales TWT)**
02001615-00
01020673-00
(qty 2)
01020679-01,
01020680-01,
01020681-02,
01020682-02
01022898-03,
01022898-04
02001630-00
01026110-00
(qty 2)
01026664
400 W ODU, 270 W
ODU
01022897-00
01020673-00
01020685-00
01020686-00
01022898-02
NOT
REQUIRED
01026110-00
01026664
2.25 kW Super Linear
TWTA (single-drawer)
01032115-00
01020673-00
01020679-02
01020680-02
01022898-00
NOT
REQUIRED
01026110-00
01026664
Millitron Ka-band
01032360-00
01022901-01
01024852-00
01032361-00
01032362-00
NOT
REQUIRED
01024880-00
01026150-06
01026150-07
01026671
VSTAR 30
01022896-00
01022891-00
NOT
REQUIRED
01024880-00
01026150-06
01026150-07
01026671
J-RACK
(18.0 - 26.5 GHz and
26.0 - 40.0 GHz)
01024871-00
01022901-00
NOT
REQUIRED
01024880-01
01026150-06
01026150-07
01026671
Compact Klystron
Power Amplifier
(CKPA)
01027831-00
01020673-00
NOT
REQUIRED
01026110-00
01026664
*HV Test Set also available for other products.
**Also requires Test Plub, P/N 8199915900
Page 3 of 4 MKT-60 ISSUE 7
01024852-00
(qty 2)
01026197-00
01017058-02
01017059-03
01027823-00
01027824-00
01027822-00
C-Band / Ku-Band
CPI Service Centers
High Voltage Test Set
North America Western Region Hdqrtrs
811 Hansen Way
Palo Alto, CA 94303 USA
Singapore
237 Alexandra Road
#05-09&10 the Alexcier
Singapore 159929
Europe
Industrieweg 28A
3846BE Harderwijk, Netherlands
Russia
NPO SP
Akademika Koroleva, str 12 bldg 4
Moscow 127427 Russia
North, Central America
Caribbean
Tel +1 (650) 846-3600
Toll Free +1 (800) 231-4818
FAX +1 (650) 424-1744
Asia Pacific
Tel +65 6225-0011
FAX +65 6225-5525
Europe
Africa (exc. S. Africa)
Middle East
Tel +31 (341) 414500
FAX +31 (341) 422050
Commonwealth of
Independent States (CIS)
Tel +7 (495) 727-0735
FAX +7 (495) 727-0735
x121
India - New Delhi
ADSAT Engineers Private Ltd.
207, SSG East Plaza, Local Shopping Ctr
Mayur Vihar Phase - III
Delhi 110 096 India
India - New Delhi
India - Kolkata
Satcom Elektronics Pvt. Ltd.
Module No. 104, SDF Building
Ground Floor, Block-GP, Sector V
Salt Lake Electronic Complex
Kolkata 700 091 India
India - Kolkata
South Africa
Specialized Turn-Key Systems (Pty) Ltd.
No. 14 Kastaiing Nook
Highveld Technopark
Centurion, 0157 Rep. of South Africa
Republic of South Africa
Tel +91 (11) 4557-6716
FAX +91 (11) 4761-9452
Tel +91 (33) 2357-8947
FAX +91 (33) 2357-9182
Tel +27 (12) 665-0330
FAX +27 (12) 665-0344
Peoples Republic of China
CPI Beijing Service Center
1-B-1201 No. 13 Beiyuan Road
Chaoyang, Beijing 100107 PR China
Peoples Republic of China
Shanghai Tian Wo Network Techn. Co. Ltd.
No. 145 Lan Xi Road
Shanghai 200062 PR China
Peoples Republic of China Beijing
Tel +86 (10) 5109-5369
FAX +86 (10) 5109-5370
Peoples Republic of China Shanghai
Tel +86 (21) 5266-9658
FAX +86 (21) 5266-9658
Japan
Foresight Techno Co., Ltd.
Marubun CPI Service Center
Dokoh Bldg,
3-6 Minamisuna 3-Chome
Kohtoh-ku, Tokyo 136-8580 Japan
Japan
Taiwan
Transcontinental Enterprise Co. Ltd.
5F-1, No. 15, Lane 174, Sec 3.
Cheng Kung Road
Nei Hu, Taipei 114 Taiwan
Taiwan
Corporacion de Alta Tecnologia SAC
Montegrande 109 Ste 502 Surco
Lima 33
Peru
Brasil
Logictel
Rua Santo Cristo 226
Bloco B, 2 Andar
Rio de Janeiro 20220-305 Brasil
Australia
GAPSAT Pty Ltd
1/38 Dacre Street
Mitchel, ACT 2911
Australia
Tel +81 (3) 3648-4671
FAX +81 (3) 3648-5535
Tel +886 (2) 8792-2777
FAX +886 (2) 8792-2111
Peru
Tel +51 (1) 372 0210
Tel +51 (1) 271-4101
FAX +51 (1) 372-0278
Brasil
Tel + 55 (21) 3232-4705
FAX +55 (21) 3232-4869
Australia
Tel + 61 (2) 6242-9443
FAX +61 (2) 6241-4122
For a complete list of our service locations, please visit www.cpii.com/support
Quality Management
System - ISO 9001:2008
For more detailed information, please refer to the corresponding CPI technical description if one has been
published, or contact CPI. Values noted are at 25°C. Specifications may change without notice as a result of
additional data or product refinement. Please contact CPI before using this information for system design.
MKT 60, ISSUE 7 dated JUN 2014
Page 4 of 4