750W Touchscreen TWTA ™ for Satellite Communications C - Band The T5CI Series 750 Watt TWT High Power Amplifier— high efficiency in a compact package Meets International Safety Standard EN-60215, Electromagnetic Compatibility 2004/108/EC and Harmonic Standard EN-61000-3-2 to satisfy worldwide requirements. Efficient Employs a high efficiency dual-depressed collector helix traveling wave tube backed by many years of field-proven experience in airborne and military applications. CAN-Bus architecture improves noise immunity and reliability. Touchscreen Graphical Interface State of the art touchscreen interface with both amplifier and/or system level control capabilities. Includes fault logs, parameter trending and scopescreen for monitoring performance. Internal switch control eliminates need for external controllers. Easy to Maintain Modular design and built-in fault diagnostic capability with convenient and clearly visible indicators for easy maintainability in the field. A USB port is available for uploading new firmware and system configurations, and downloading logs and system configurations for cloning to other units. Worldwide Support Backed by over three decades of satellite communications experience, and CPI’s worldwide 24-hour customer support network that includes more than twenty regional factory service centers. 811 Hansen Way P.O. Box 51625, Palo Alto, CA 94303 tel: +1 (650) 846-3803 fax: +1 (650) 424-1744 e-mail: [email protected] www.cpii.com/satcom 7 5 0 W To u c h s c r e e n T W T A Global Applications Provides 750 watts of power in a 5 rack unit package, digital ready, for wideband, single-and multi-carrier satellite service in the 5.85 - 6.65 GHz frequency bands, with options for extended band to 6.725 or 7.075 GHz. Ideal for transportable and fixed earth station applications where space and prime power are at a premium. C-Band Compact C-B a n d SPECIFICATIONS, T5CI Electrical OPTIONS: • Integral Linearizer • Remote Control Panel • Frequency 5.85 - 6.65 GHz (extended bands available from 5.85 GHz to 6.725 or 7.075 GHz) Output Power TWT Flange Intermodulation -23 dBc or better with with regard to each carrier at total output power level of 51.13 dBm (-27 dBc at 55.25 dBm with linearizer). 750 W min. (58.75 dBm) 665 W min. (58.25 dBm) Spectral Regrowth -30 dBc at 1 symbol rate at 3 dB OBO with optional linearizer Bandwidth 800 MHz (875 and 1225 MHz optional) Gain 7 0 dB min. at rated power, 88 dB max. 75 dB min. at small signal, 90 dB max. Group Delay 0.01 ns/MHz linear max. (in any 80 MHz band)0.005 ns/MHz sq. parabolic max. 0.5 ns pk-pk ripple max. RF Level Adjust Range 0 to 30 dB (via PIN diode attenuator), 0.1 dB steps Gain Stability At constant drive & temp.±0.25 dB/24 hr. max. (after 30 min. warmup) Over temp., constant drive±1.0 dB over oper. temp. range (typical) (any frequency) ±0.75 dB over ±10°C (typical) • Redundant and Power Combined Subsystems External Receive Band Reject Filter (Increases loss by a minimum of 75 dB up to 12.75 GHz) Small Signal Gain Slope ±0.04 dB/MHz max. • SNMP compatibility Small Signal Gain Variation Across any 40 MHz band 0.5 dB pk-pk max. Across any 500 MHz 2.5 dB pk-pk max. Across full band, with linearizer 3.5 dB pk-pk max. •LifeExtender™/LifePredictor Input VSWR 1.3:1 max. • High Altitude Operation Kit (for amplifiers to be used at over 10,000 feet (3,048 meters) above sea level. Output VSWR 1.3:1 max. • L-Band Block Upconverter (BUC) --- specifications for when BUC is included are not contained in this document. Contact CPI for details. Electrical (continued) Load VSWR Continuous operation 2.0:1 Full spec. compliance 1:5:1 Operation without damage Any value Phase Noise IESS-308/309 phase noise profile -12 dB AC fundamentals -52 dBc Sum of spurs (370 Hz to 1 MHz) -50 dBc AM/PM Conversion2.5°/dB max. for a single-carrier at 6 dB below rated power. With optional integral linearizer, improves to 2.0 deg/dB typ at 3 dB OBO. Harmonic Output-70 dBc at rated power, second and third harmonics Noise Density <-150 dBW/4 kHz, 3.4 to 4.2 GHz <-75 dBW/4 kHz, passband <-72 dBW/4 kHz, passband with linearizer option NPR 19 dB at 4 dB OBO with optional linearizer Primary Power Voltage Frequency Single phase, 208-240 VAC ±10% 47-63 Hz, 15 A max. Power Consumption2.2 kVA typ. (at saturated output power) 2.4 kVA max. Power Factor 0.95 min. Inrush Current 200% max. Environmental (Operating) Ambient Temperature-20°C to +60°C operating -40°C to +70°C non-operating Relative Humidity 95% non-condensing Altitude10,000 ft. with standard adiabatic derating of 2°C/1000 ft., operating; 50,000 ft., non-operating Shock and VibrationDesigned for normal transportation environment per Section 514.4 MIL-STD-810G. Designed to withstand 20G at 11 ms (1/2 sine pulse) in non-operating condition. Mechanical CoolingForced air with integral blower. Rear air intake & exhaust. Maximum external pressure loss allowable: 0.5 inches water column RF Input Connection Type N female RF Output Connection CPR-137F waveguide flange, grooved, threaded UNC 2B 6-32 M&C Interface RJ45 Ethernet, includes embedded GUI control; Serial - RS422/485, RS232 USB Port Download/Upload software, logs RF Output Monitor Type N female Dimensions (W x H x D) 19 x 8.75 x 24 in. (483 x 222 x 610 mm) Weight 78 lbs (35 kg) nom. Heat and Acoustic Touchscreen TWTA Sample Redundancy System Schematic Display; Various Configurations Available Quality Management System - ISO 9001:2008 Certificate Number: 30515 For more detailed information, please refer to the corresponding CPI Technical Description. Note: Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 369, ISSUE 6 MAR 2015 PDF Heat Dissipation 1,440 Watts to duct; 360 W to room Acoustic Noise 68 dBA (as measured at 3 ft.)