K3C - Communications & Power Industries

C-Band Compact Klystron High Power Amplifier
The Classic Space-Saving Alternative Solution
C - Band
C-Band
The Compact
High Power Amplifier
C-Band CKPA—
provides up to 3.35 kW
of power in a dual drawer
package with power tracker/
power saver
Easy Maintenance, Easy Handling
Assures high reliability in a compact design based
on field proven performance. Features classic
klystron technology common to CPI's renowned
generations of klystron high power amplifiers.
Offers easy access to all areas of the amplifier with
no harness obstructions. Separate RF and Power
Supply drawers slide out from a standard rack.
Worldwide Support
Installation Versatility
Racks and stacks two amplifiers into one cabinet in
any configuration.
Backed by over three decades of satellite
communications experience, and CPI's worldwide
24-hour customer support network that includes
sixteen regional factory service centers.
Useful Displays
Provides a clear, high quality, graphical display with
a wide viewing angle and a sharp appearance.
Clearly displays all critical functions including a
comprehensive event log.
811 Hansen Way
P.O. Box 51625, Palo Alto, CA 94303
tel: +1 (650) 846-3803
fax: +1 (650) 424-1744
e-mail: [email protected]
www.cpii.com/satcom
Compact Klystron High Power Amplifier
Technology Reuse at its Best
C -B a n d
SPECIFICATIONS, Model K3C C-Band CKPA
Electrical
Electrical (continued)
Frequency Ranges
5.85 0 -6.425 GHz; others available
Power Factor
0.95 min.
Klystron Power Output
3.0/3.35 kW max. (64.77/65.44 dBm)
Inrush Current, peak
Amplifier Output
at Flange1
2.6/2.9 kW (64.15/64.62 dBm)
180% of normal line current peak
max. (first half cycle only)
Instantaneous Bandwidth
45 MHz; 80 MHz available as an option
RF Input Connection
Type N female
Power Adjustability
0 to -20 dB of output with ±0.1 dB
typical resolution
RF Output Connection
CPR-137 F flange
RF Power Monitors
Type N female
Gain at Rated Power
77 dB, min.
Gain Stability vs. Time
±0.25 dB/24 hr. max. at constant drive
and temperature
• Protection Switching
Gain Stability vs. Temp.
1 dB max. from 20° to 40°C; ±2.5 dB max
from 0° to 50°C (at constant drive)
Dimension (W x H x D without fans and handles)
RF Drawer
19 x 21 x 28.75 in.
(483 x 533 x 730 mm)
PS Drawer
19 x 8.75 x 24 in.
(483 x 223 x 610 mm)
• Low Phase Noise
Gain Slope (at rated power)
0.04 dB/MHz max. over Fo ±13 MHz
(Fo ±18 MHz with 80 MHz option)
OPTIONS:
• Motorized Channel
Selector: (<1 second)
• Remote Control Panel
• Linearizer
Mechanical
Gain Variation (at rated power) 0.4 dB pk-pk max. over Fo ±30 MHz
(Fo ±18 MHz with 80 MHz option)
• L-Band Block
Upconverter (BUC), see
TD-107 or contact sales
for specifications
• Ethernet Interface
Forced air with integral
blower and fans; separate klystron
collector cooling path
1.25 max.
1.30 max.
Air Flow Rate, Klystron
300 cfm min., at sea level
Load VSWR
2.0:1 max. for full spec. compliance;
any value for operation without damage
External Ducts Backpressure
0.5 inch water gauge
total, maximum.
Residual AM2
-50 dBc max., 20 to 400 Hz
-60 dBc max., 400 Hz to 2 kHz
-80 dBc max., 2 kHz to 500 kHz
Klystron Heat Loss
9000 W typ.
Heat Loss in Room
(cabinet less Klystron)
1500 W typ.
Acoustic Noise
68 dBA nominal, measured
3 ft. from front of equipment
AM/PM Conversion
(at rated power)
4°/dB max.
Noise Density
(at rated gain)
-135 dBW/4 kHz, 3.7 to 4.2 GHz;
-70 dBW/4 kHz, in passband
(-65 dBW/4 kHz, passband with linearizer)
(-60 dBW/4 kHz, passband with BUC)
-110 dBW/MHz, 4.2 to 40 GHz
(excluding passband)
Phase Noise2
Exceeds requirements of INTELSAT
Standard IESS-308/309 by -10 dB
at -10 dB backoff
Intermodulation
-29 dBc with two equal carriers at total output
7 dB below rated single-carrier output
Group Delay
In any 36 MHz band 72 MHz band with
(80 MHz option:
0.25 ns/MHz linear max.
0.05 ns/MHz2 parabolic max.
2.0 ns pk-pk ripple max.
Primary Power 3
All ratings are ± 10%, 47-63 Hz 3-phase with
neutral and ground:
200 VAC w/ neutral
208 VAC
380 to 415 VAC
11.0 kW max. Typical values for the following
RF output backoffs with respect to rated
(power saver on):
10.5 kW @ 0 dB (rated)
10.5 kW @ -4 dB
8.5 kW @ -7 dB
7.0 kW @ -10 dB
6.0 kW @ -13 dB
Certificate Number: 30515
Please check CPI’s web site to ensure most current data sheet.
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
PDF
Cooling
Output VSWR
Power Consumption4
09/11
170 lbs w/klystron (77.3 kg)
100 lbs (45.4 kg)
Input VSWR
• Variable Speed Blower
MKT 91, ISSUE 5
Weight
RF Drawer
PS Drawer
Environmental
Ambient Temperature
-10° to +50° operating;
-40° to +80° non-operating
Relative Humidity
95%, non-condensing
Altitude
operating:
non-operating:
Shock and Vibration
10,000 ft. (3000 m) with standard
adiabatic temp derating of
2°C/1000 ft. or 6.5°C/km
40,000 ft. (12,000 m)
As normally encountered
in satellite earth stations
and shipping
1Harmonic filter can be removed as an option. Add 0.25 dB to amplifier output for
units without harmonic filter. Output VSWR without filter is 1.25:1 max.
2Prime power AC line unbalance not to exceed 3%. Excess imbalance may cause
an increase in residual RF noise (AM, FM and PM). Phase noise increase is typically
2.5 dB / % imbalance.
3AC current harmonic content: less than 20%, primarily fifth and seventh harmonics.
Harmonics must be considered when choosing UPS sources.
4Lower power consumption can be achieved if power saver (included as standard)
is employed when operating below rated output power.