DBS-Band Compact Klystron High Power Amplifier The Classic Space-Saving Alternative Solution D BS- Band The Compact High Power Amplifier DBS-Band CKPA—provides up to 2.4 kW of power in a dual drawer package with power tracker/ power saver DBS-Band Easy Maintenance, Easy Handling Assures high reliability in a compact design based on field proven performance. Features classic klystron technology common to CPI's renowned generations of klystron high power amplifiers. Offers easy access to all areas of the amplifier with no harness obstructions. Separate RF and Power Supply drawers slide out from a standard rack. Worldwide Support Installation Versatility Racks and stacks two amplifiers into one cabinet in any configuration. Backed by over three decades of satellite communications experience, and CPI's worldwide 24-hour customer support network that includes sixteen regional factory service centers. Useful Displays Provides a clear, high quality, graphical display with a wide viewing angle and a sharp appearance. Clearly displays all critical functions including a comprehensive event log. 811 Hansen Way P.O. Box 51625, Palo Alto, CA 94303 tel: +1 (650) 846-3803 fax: +1 (650) 424-1744 e-mail: [email protected] www.cpii.com/satcom Compact Klystron High Power Amplifier Technology Reuse at its Best DBS -B a n d SPECIFICATIONS, DBS-Band CKPA Electrical Electrical (continued) Frequency Ranges 17.3 to 18.1 GHz (to 18.4 GHz optional) Power Factor 0.95 min. Klystron Power Output 1.7 to 2.4 kW min. (62.3 to 63.8 dBm) Inrush Current, peak Amplifier Output at Flange1 1.4 to 2.0 kW min. (61.46 to 62.01 dBm) 180% of normal line current peak max. (first half cycle only) Bandwidth 50 MHz (optional 85 MHz available at 1700 W) RF Input Connection Type N female RF Output Connection WR-62 with grooved flange • Motorized Channel Selector: (<1 second) Power Adjustability 0 to -20 dB of output with ±0.1 dB typical resolution RF Power Monitors Type N female (Type SMA for 18.4 GHz klystron) Gain at Rated Power 75 dB, min. • Remote Control Panel Gain Stability vs. Time ±0.25 dB/24 hr. max. at constant drive and temperature Gain Stability vs. Temp. 1 dB max. from 20° to 40°C; ±2.5 dB max from 0° to 50°C (at constant drive) Dimension (W x H x D without fans and handles) RF Drawer 19 x 21 x 28.75 in. (483 x 533 x 730 mm) PS Drawer 19 x 8.75 x 24 in. (483 x 223 x 610 mm) Gain Slope (at rated power) 0.04 dB/MHz max. over Fo ±18 MHz OPTIONS: • Protection Switching • Extended Frequency (17.3-18.4 GHz), available with 1700 watt klystron only • Linearizer • L-Band Block Upconverter (BUC) (Contact factory for typical performance specifications with integrated BUC) • Ethernet Interface • Variable Speed Blower Mechanical Gain Variation (at rated power) 0.4 dB pk-pk max. over Fo ±18 MHz Weight RF Drawer PS Drawer Input VSWR 1.30 max. Cooling Output VSWR 1.35 max. Load VSWR 2.0:1 max. for full spec. compliance; any value for operation without damage Forced air with integral blower and fans; separate klystron collector cooling path Air Flow Rate, Klystron Residual AM2 -50 dBc max., 20 to 400 Hz -60 dBc max., 400 Hz to 2 kHz -80 dBc max., 2 kHz to 500 kHz 300 cfm min., at sea level and 23°C ambient air External Ducts Backpressure 0.5 inch water gauge total, max. AM/PM Conversion (at rated power) 6°/dB max. (7°/dB max. for 2400 W klystron) Klystron Heat Loss5 9,500 W typ. 1400 W typ. Harmonic Output -80 dBc Heat Loss in Room (cabinet less Klystron) Noise and Spurious (at rated gain) -135 dBW/4 kHz, 10.95 to 12.7 GHz; -65 dBW/4 kHz, in passband -60 dBW/4 kHz, passband with linearizer -55 dBW/4 kHz, passband with BUC; -110 dBW/MHz, 12.7 to 40 GHz (excluding passband) Acoustic Noise 68 dBA nominal, measured 3 ft. from front of equipment Ambient Temperature -10°C to +50°C operating; -40°C to +80°C non-operating Exceeds requirements of INTELSAT Standard IESS-308/309 by -10 dB at -10 dB backoff Relative Humidity 95%, non-condensing Phase Noise2 Intermodulation -28 dBc with two equal carriers at total output 7 dB below rated single-carrier output Group Delay In any 72 MHz band: 0.10 ns/MHz linear max. 0.02 ns/MHz2 parabolic max. 2.0 ns pk-pk ripple max. Primary Power 3 All ratings are ± 10%, 47-63 Hz 3-phase with neutral and ground: 200 VAC w/ neutral 208 VAC 380 to 415 VAC Power Consumption4 11.0 kW max. (12.5 kW for 3.0 kW klystron). Typical values for the following RF output backoffs with respect to rated (power saver on, 2.45 kW klystron): 10.9 kW @ 0 dB (rated) 10.9 kW @ -4 dB 9.0 kW @ -7 dB 7.5 kW @ -10 dB 6.0 kW @ -13 dB Certificate Number: 30515 Please check CPI’s web site to ensure most current data sheet. For more detailed information, please refer to the corresponding CPI Technical Description. Note: Specifications may change without notice as a result of additional data or product refinement. Please contact CPI before using this information for system design. MKT 93, ISSUE 4 10/11 PDF 190 lbs w/klystron (86.4 kg) 95 lbs (43.2 kg) max. Environmental Altitude operating: non-operating: Shock and Vibration 10,000 ft. (3000 m) with standard adiabatic temp derating of 2°C/1000 ft. or 6.5°C/km 40,000 ft. (12,000 m) As normally encountered in satellite earth stations and shipping 1Harmonic filter can be removed as an option. Add 0.25 dB to amplifier output for units without harmonic filter. Output VSWR without filter is 1.25:1 max. 2Prime power AC line unbalance not to exceed 3%. Excess imbalance may cause an increase in residual RF noise (AM, FM and PM). Phase noise increase is typically 2.5 dB / % imbalance. 3AC current harmonic content: less than 20%, primarily fifth and seventh harmonics. Harmonics must be considered when choosing UPS sources. 4Lower power consumption can be achieved if power saver (included as standard) is employed when operating below rated output power. 5For 2400 W klystron only.