GAS GENERATOR SET MTU 10V0068 GS75

GAS GENERATOR SET
MTU 10V0068 GS75
75 kWe /60 Hz /Standby
208 - 600V
SYSTEM RATINGS
Standby
Voltage (L-L)
Phase
PF
Hz
Natural Gas
Ratings: Amps
Natural Gas
Ratings: kW/kVA
LP Gas
Ratings: Amps
LP Gas
Ratings: kW/kVA
skVA@30%
Voltage Dip
Generator Model
Temp Rise
Connection
240V**
1
1
60
240V**
1
1
60
208V**
3
0.8
60
240V**
3
0.8
60
480V**
3
0.8
60
600V**
3
0.8
60
292
292
243
210
105
84
70/70
70/70
70/87.5
70/87.5
70/87.5
70/87.5
313
313
260
226
113
90
75/75
75/75
75/93.75
75/93.75
75/93.75
75/93.75
311
363CSL1617
130 °C/40 °C
107
431CSL6202
130 °C/40 °C
216
362CSL1604
130 °C/40 °C
216
362CSL1604
130 °C/40 °C
288
362CSL1604
130 °C/40 °C
235
362PSL1635
130 °C/40 °C
4 LEAD
12 LEAD ZIG-ZAG
12 LEAD LOW WYE
12 LEAD HI DELTA
12 LEAD HI WYE
4 LEAD WYE
** UL 2200 Offered
Note: This unit is available with a dual fuel configuration.
CERTIFICATIONS AND STANDARDS
// Generator set is designed and manufactured
in facilities certified to standards ISO 9001:2008 and
ISO 14001:2004
// UL 2200 / CSA – Optional
– UL 2200 Listed
– CSA Certified
Performance Assurance Certification (PAC)
- Generator Set Tested to ISO 8528-5 for Transient Response
- Verified product design, quality and performance integrity
- All engine systems are prototype and factory tested
// Power Rating
// - Accepts Rated Load in One Step Per NFPA 110
2
/ // /
MTU 10V0068 GS75 (75 kWe) - Standby
STANDARD FEATURES*
MTU Onsite Energy is a single source supplier
Global Product Support
2 Year Standard Warranty
6.8L Engine
- 6.8 Liter Displacement
- 4-Cycle
// Optional Fuels: LP Liquid and Dual Fuel
// Engine-generator resilient mounted
// Complete Range of Accessories
// // // // Generator
- Brushless, Rotating Field Generator
- 2/3 Pitch Windings
- 300% Short Circuit Capability
// Digital Control Panel
- UL Recognized, CSA Certified, NFPA 110
- Complete System Metering
- LCD Display
// Cooling System
- Integral Set-Mounted
- Engine Driven Fan
// STANDARD EQUIPMENT*
// Engine
Heavy Duty Air Cleaner
Oil Pump
Oil Drain Extension & S/O Valve
Full Flow Oil Filter
Jacket Water Pump
Thermostat
Blower Fan & Fan Drive
Radiator - Unit Mounted
Electric Starting Motor - 12V
Governor – Electronic Isochronous
Base - Formed Steel
SAE Flywheel & Bell Housing
Charging Alternator - 12V
Battery Rack & Cables
Flexible Exhaust Connection
EPA Certified Engine
// Generator
NEMA MG1, IEEE and ANSI standards compliance for temperature rise
and motor starting
Sustained short circuit current of up to 300% of the rated current for
up to 10 seconds
Self-Ventilated
Superior Voltage Waveform
Solid State, Volts-per-Hertz Regulator
±1% Voltage Regulation No Load to Full Load Regulation
Brushless Alternator with Brushless Pilot Exciter
4 Pole, Rotating Field
130 °C Maximum Standby Temperature Rise
1 Bearing, Sealed
Flexible Coupling
Full Amortisseur Windings
125% Rotor Balancing
3-Phase Voltage Sensing
100% of Rated Load - One Step
5% Maximum Total Harmonic Distortion
// Digital Control Panel(s)
Digital Metering
Engine Parameters
Generator Protection Functions
Engine Protection
SAE J1939 Engine ECU Communications
Windows®-Based Software
Multilingual Capability
Remote Communications to RDP-110 Remote Annunciator
Programmable Input and Output Contacts
UL Recognized, CSA Certified, CE Approved
Event Recording
IP 54 Front Panel Rating with Integrated Gasket
NFPA110 Compatible
* Represents standard product only. Consult Factory/MTU Onsite Energy Distributor for additional configurations.
3
/ // /
MTU 10V0068 GS75 (75 kWe) - Standby
APPLICATION DATA
// Engine
Manufacturer
Model
Type
Aspiration
Arrangement
Displacement: L (in3)
Bore: cm (in)
Stroke: cm (in)
Compression Ratio
Rated RPM
Engine Governor
Maximum Power (NG): kWm (bhp)
Maximum Power (LP): kWm (bhp)
Speed Regulation
Air Cleaner
// // Ford
6.8L V10
4-Cycle
Naturally Aspirated
10-V
6.8 (415)
9 (3.55)
10.6 (4.17)
9:1
1,800
Bosch
85.6 (114.8)
89.4 (119.9)
C/F
Dry
At 100% of Power Rating: m3/hr (ft3/hr)
At 75% of Power Rating: m3/hr (ft3/hr)
At 50% of Power Rating: m3/hr (ft3/hr)
// LPG
11.4 (403)
9.3 (328)
6.8 (239)
Cooling - Radiator System
NG and LPG
50 (122)
0.12 (0.5)
123 (32.5)
78.2 (4,448)
19.1 (1,086)
2.8 (3.8)
Liquid Capacity (Lubrication)
Total Oil System: L (gal)
Engine Jacket Water Capacity: L (gal)
System Coolant Capacity: L (gal)
5.7 (1.5)
5.9 (1.55)
25.58 (6.75)
Electrical
Electric Volts DC
Cold Cranking Amps Under -17.8 °C (0 °F)
// NG
27.2 (960)
21.5 (759)
15.6 (551)
Ambient Capacity of Radiator: °C (°F)
Maximum Restriction of Cooling Air, Intake,
and Discharge Side of Rad.: kPa (in. H20)
Water Pump Capacity: L/min (gpm)
Heat Rejection to Coolant: kW (BTUM)
Heat Radiated to Ambient: kW (BTUM)
Fan Power: kW (hp)
// // Fuel Consumption (NG-1000 BTU/ft3 / LP-2500 BTU/ft3)
12
925
Fuel Inlet
Fuel Supply Connection Size
Fuel Supply Pressure: mm H20 (in. H20)
Air Requirements
Aspirating: *m3/min (SCFM)
Air Flow Required for Rad.
Cooled Unit: *m3/min (SCFM)
Remote Cooled Applications;
Air Flow Required for Dissipation
of Radiated Gen-set Heat For a
Max of 25 °F Rise: *m3/min (SCFM)
NG and LPG
4.54 (160.5)
303.4 (10,715)
103 (3,369)
* Air density = 1.184 kg/m3 (0.0739 lbm/ft3)
1 1/2” NPT
178–279 (7–11)
// Exhaust System
Gas Temp. (Stack): °C (°F)
Gas Volume at Stack
Temp: m3/min (CFM)
Maximum Allowable
Back Pressure: kPa (in. H20)
NG and LPG
660 (1,220)
15.3 (539)
4.98 (20)
4
/ // /
MTU 10V0068 GS75 (75 kWe) - Standby
WEIGHTS AND DIMENSIONS
Drawing above for illustration purposes only, based on standard open power 480 volt generator set. Lengths may vary with other voltages. Do not use for installation design.
See website for unit specific template drawings.
System
Open Power Unit (OPU)
Dimensions (L x W x H)
2,199 x 1,158 x 1,438 mm (86.6 x 45.6 x 56.6 in)
Weight (dry)
1,125 kg (2,481 lb)
SOUND DATA
Unit Type
Level 0: Open Power Unit dB(A)
Standby Full Load (NG)
75.5
Standby Full Load (LP)
76.1
Sound data is provided at 7 m (23 ft). Generator set tested in accordance with ISO 8528-10 and with infinite exhaust.
EMISSIONS DATA
Fuel Type
Natural Gas
Liquid Propane
THC + NOx
7.53
7.65
RATING DEFINITIONS AND CONDITIONS
CO
30.49
47.95
All units are in g/hp-hr and are EPA weighted cycle values.
Emission levels of the engine may vary with ambient
temperature, barometric pressure, humidity, fuel type and
quality, installation parameters, measuring instrumentation, etc.
The data was obtained in compliance with US EPA regulations.
C/F = Consult Factory/MTU Onsite Energy Distributor
N/A = Not Available
MTU Onsite Energy
A Rolls-Royce Power Systems Brand
www.mtuonsiteenergy.com
Standby ratings apply to installations served by a reliable
utility source. The standby rating is applicable to varying
loads for the duration of a power outage. No overload
capability for this rating. Ratings are in accordance with
ISO 3046-1, BS 5514, and AS 2789. Average load
factor: ≤ 85%.
// Deration Factor:
Altitude: Consult your local MTU Onsite Energy Power
Generation Distributor for altitude derations.
Temperature: Consult your local MTU Onsite Energy Power
Generation Distributor for temperature derations.
// © MTU Onsite Energy. Subject to alteration due to technological advances. OE 23 679 (72 3E) 2014-08
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.