RISE TIME - Rhombus Industries

RISE TIME
Rise Time is a parameter of concern in Pulse and Wideband transformers and Passive Delay Lines
RISE TIME MEASUREMENT (Tr): (Pulse Transformers)
The Time required for the pulse amplitude to increase from 10% to 90% amplitude is known as the Rise
Time of the pulse transformer. Rise time is controlled by the dynamic parameters of the transformer and
the circuit impedances. Rise time is related to the high frequency response of the transformer.
Rhombus Industries standard method for testing risetime of Pulse and Wideband transformers can be
seen below in the schematic.
Both input and output impedances must be matched to the transformer.
The input voltage should be comparable to in circuit volatages of the system the transformer is to be used in.
The output signal is then adjusted to be 5 divisions vertical from ground (0% to 100% on scope).
The elapsed time is then measured from 10% to 90% of the leading or rising edge of the pulse.
To obtain the true rise time the rise time of the input signal must be taken into account. (Tr) of the transformer under test
use the following equation:
Tr =
Tro2 - Tri2
RISE TIME MEASUREMENT (Tr): (Passive Delay Lines)
Rise Time measurements are very similar to those done with wideband transformers. However, due to the sensitivity of
the measurement, special considerations of the test equipment used should be kept in mind.
TEST EQUIPMENT:
The following test equipment is the minimum recommended for testing of passive delay
lines:
1) Minimum 350 MHz bandwidth, dual channel oscilloscope.
2) Pulse Generator capable of 1.0 ns Rise Time .
3) Voltage probe with impedance of approximately 10 times the impedance of the
delay line under test and capacitance less than 3 pf.
RISETIME 10/97
Specifications subject to change without notice.
Rhombus
Industries Inc.
23
15801 Chemical Lane, Huntington Beach, CA 92649-1595
Tel: (714) 898-0960 • Fax: (714) 896-0971