LD02-10Bxx - RSG Electronic Components GmbH

LD01 & LD02 SERIES
1W/2W, ULTRA SMALL SIZE AC-DC CONVERTER
LD01 & LD02 Series are the compact size power converter offered by
MORNSUN. It features compact size,3000VAC safer isolation. It offers good
EMC performance, meets IEC61000, UL60950 and IEC60950 standards, and
widely used in industrial, electricity, instruments and civil applications. If want to
used in electricity and other higher requirement to EMC applications, must
connect typical application.
RoHS
PRODUCT FEATURES
1. Wide Input voltage Range: 85~305VAC/120~430VDC
2. AC and DC all in one (input from the same terminal)
3. Small size, low Ripple and Noise
4. EMC meets EN55022, EN55024
5. Low Standby Power, high efficiency, green power
6. Over output current protection, short circuit protection
7. Meet IEC61000, UL60950 and IEC60950 standards
8. 3 years warranty
9. Mounting: PCB mounting, Chassis mounting with Screw
Terminals, DIN-Rail mounting
PART NUMBER SYSTEM
LD01-10B24A2S
Special Pack age
Output Voltage
Output Sty le
Input Voltage
Isolation Voltage
Rated Power
Pac kage
Produc t Series
SELECTION GUIDE
Output (Vo/Io)
Max.
Capacitive
Load
LD01-10B03
3.3V/300mA
4000μF
63%
LD01-10B05
5V/200mA
4000μF
68%
LD01-10B09
9V/111mA
2200μF
72%
12V/83mA
2200μF
73%
15V/67mA
1000μF
24V/42mA
680μF
LD02-10B03
3.3V/600mA
4000μF
65%
LD02-10B05
5V/400mA
4000μF
70%
LD02-10B09
9V/222mA
2200μF
72%
12V/167mA
15V/133mA
24V/83mA
2200μF
1000μF
680μF
76%
76%
78%
Approval
Model
Package
Power
1W
LD01-10B12
LD01-10B15
UL/CE
LD01-10B24
33.7x22.2x18mm
2W
LD02-10B12
LD02-10B15
LD02-10B24
Ripple and
Noise
(Typ.)
Efficiency
(230VAC,Typ)
Standby
Power(Typ.)
74%
100mV
75%
0.1W
INPUT SPECIFICATIONS
Item
Input Voltage Range
Test Conditions
Min.
Typ.
Max.
AC Input
85
--
305
DC Input
120
--
430
47
--
63
LD01 series
--
--
0.03
LD02 series
--
--
0.044
LD01 series
--
--
0.017
LD02 series
--
--
0.025
115VAC Input
--
5A
--
230VAC Input
--
11A
--
--
--
0.15
Input Frequency
115VAC Input
Input Current
230VAC Input
Inrush Current
Leakage Current
Recommended External Input Fuse
(Special package series include fuse)
Unit
V
Hz
A
mA
1A/300V slow blow
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LD01 & LD02
2013.07.09-A/4
Page 1 of 5
OUTPUT SPECIFICATIONS
Test Conditions
Item
Min.
Typ.
Max.
3.3V output
--
±6
--
Others
--
±5
--
±2
--
Unit
Output Voltage Accuracy
Full load
Line Regulation
Full load
--
Load Variation
10% to 100% Load
--
±5
--
Ripple & Noise
20MHz Bandwidth(p-p)
--
100
200
mV
Unit
Short Circuit Protection
Continuous, and auto resume
Over Current Protection
≥110% IO can auto resume
%
COMMON SPECIFICATIONS
Item
Min.
Typ.
Max.
Operating Temperature
Test Conditions
-25
--
+70
Storage Temperature
-40
--
+85
Operating Humidity
--
--
90
Storage Humidity
--
--
95
3.3
--
--
%/℃
3000
--
--
VAC
--
--
100
KHz
PCB mounting
--
20
--
A2S Chassis mounting
--
40
--
A4S DIN-Rail mounting
--
60
--
℃
%RH
Power derating
55°C~70°C
I/O-isolation Voltage
Input-Output
Tested for 1 minute
Switching Frequency
Weight
Safety standards
IEC60950/UL60950/EN60950
Safety approvals
UL60950/EN60950
Safety Class
CLASSⅡ
Case Material
UL94V-0
Install
g
PCB mounting, Chassis mounting, DIN-Rail mounting
Cooling
Free air convection
MTBF
>300,000h @25°C
Note:
1. Ripple and Noise are measured by the method of parallel lines.
2. Unless otherwise specified, all specifications above are measured at rated input voltage and rated output load, Ta=25℃, humidity < 75%.
3. All characteristics are for listed models, and non-standard models may perform differently. Please contact our technical support for more details.
EMC SPECIFICATIONS
EMI
EMS
CE
CISPR22/EN55022, CLASS B
RE
CISPR22/EN55022, CLASS B
ESD
IEC/EN61000-4-2
Contact ±4KV/Air ±8KV
perf. Criteria B
RS
IEC/EN61000-4-3
10V/m
perf. Criteria A
EFT
IEC/EN61000-4-4
±2KV(Recommended Circuit Refer to Figure 3)
perf. Criteria B
Surge
IEC/EN61000-4-5
±1KV/±2KV(Recommended Circuit Refer to Figure 3)
perf. Criteria B
CS
IEC/EN61000-4-6
10 Vr.m.s
perf. Criteria A
PFM
IEC/EN61000-4-8
10A/m
perf. Criteria A
Voltage dips, short and
interruptions immunity
IEC/EN61000-4-11
0%-70%
perf. Criteria B
PARALLEL LINES MEASURE
Copper sheet
FUSE
AC(L)
AC(L)
+Vo
C1
AC/DC
AC( N)
AC(N)
C2
Load
Connect
Oscillograph Probe
-Vo
12. 7m m
25. 4m m
Note: C1: 1µF (Ceramic capacitor)
25. 4m m
C2: 10µF (Electrolytic capacitor)
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LD01 & LD02
2013.07.09-A/4
Page 2 of 5
PRODUCT TYPICAL CURVE
Output Power Percent(%)
Temperature Derating Graph
100
80
Input voltage:
85~305VAC
60
50
30
-25
0
40 55 70
Ambient Tem.(℃ )
Efficiency VS Output Load curve
(Vin=220VAC)
100
95
90
85
80
75
70
65
60
55
50
LD01-10B03
LD01-10B05
LD01-10B09
LD01-10B12
LD01-10B15
LD01-10B24
85
120
220
240
264
Efficiency(%)
Efficiency(%)
Efficiency VS Input Voltage curve
(Full Load)
100
95
90
85
80
75
70
65
60
55
50
45
40
305
LD01-10B03
LD01-10B05
LD01-10B09
LD01-10B12
LD01-10B15
LD01-10B24
10
20
Input Voltage(VAC)
LD02-10B03
LD02-10B05
LD02-10B09
LD02-10B12
LD02-10B15
LD02-10B24
220
240
264
Efficiency(%)
Efficiency(%)
100
95
90
85
80
75
70
65
60
55
50
120
40
50
60
70
80
90 100
Efficiency VS Output Load curve
(Vin=220VAC)
Efficiency VS Input Voltage curve
(Full Load)
85
30
Output Power Percent(%)
100
95
90
85
80
75
70
65
60
55
50
45
40
305
LD02-10B03
LD02-10B05
LD02-10B09
LD02-10B12
LD02-10B15
LD02-10B24
10
Input Voltage(VAC)
20
30
40
50
60
70
80
90 100
Output Power Percent(%)
TYPICAL APPLICATIONS
FU S E
N TC
C1
AC (L)
AC(L)
MO V
AC (N)
C2
AC(L)
TVS
AC(L) +Vo
+Vo
+Vo
CX
+
A C /D C
AC/DC
RL
A C (N )
-Vo
AC(N) -Vo
AC(N)
- Vo
(Figure 1): Typical application circuit
(Figure 2): This application is not available for this series.
Note: If you have such application, please consult to our FAE department
EMC RECOMMENDED CIRCUIT
FUSE
NTC
AC(L)
C1
CY3
AC(L)
LCM
CX
MO V
AC(N)
CY4
AC/DC
AC(N)
C2
TVS
+Vo
+
RL
-Vo
(Figure 3): This recommended circuit above is available for higher EMC requirem ents.
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LD01 & LD02
2013.07.09-A/4
Page 3 of 5
EMC RECOMMENDED CIRCUIT PCB LAYOUT
Top layer
Bottom layer
(figure 4): EMC application circuit PCB layout
Safety and recommend wiring: linewidth ≥3mm, line-line distance≥6mm, line- ground distance≥6mm
EXTERNAL CAPACITORS TYPICAL VALUE
Model
C1(µF)
C2(µF)
TVS
LD01/02-10B03
1µF/50V
220
SMBJ7.0A
LD01/02-10B05
1µF/50V
220
SMBJ7.0A
LD01/02-10B09
1µF/50V
120
SMBJ12A
LD01/02-10B12
1µF/50V
120
SMBJ20A
LD01/02-10B15
1µF/50V
120
SMBJ20A
LD01/02-10B24
1µF/50V
68
SMBJ30A
Note:
1. C1 is ceramic capacitor, it is used to filter high frequency noise. C2 is electrolytic capacitor, It is recommended to use high frequency and low impedance electrolytic
capacitors. For capacitance and current of capacitor please refer to manufacture’s datasheet. Voltage derating of capacitor should be 80% or above. TVS is a
recommended component to protect post-circuits (if converter fails).
2. For standard EMC requirement, please refer to figure 1. If higher EMC requirement, please refer to figure 3, recommended parameters are shown in the table
below.
Recommend Parameter For Higher EMC Standard Circuit
Components
Recommend Parameter
MOV
S14K350
CY3
2.2nF/400V
CY4
2.2nF/400V
CX
0.1µF/305VAC
LCM
10 mH, recommended to use MORNSUN’s FL2D-Z5-103
NTC
5D-9
FUSE
1A/300V, slow blow, it must be connected to FUSE
LD01/02XX PCB MOUNTING OUTLINE DIMENSIONS,RECOMMENDED FOOTPRINT
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LD01 & LD02
2013.07.09-A/4
Page 4 of 5
LD01/02XXA2S CHASSIS MOUNTING WITH SCREW TERMINALS
Footprint Details
Pin
1
2
3
4
Function
AC(N)
AC(L)
+Vo
-Vo
LD01/02XXA4S DIN-RAIL MOUNTING
DIN-rail modules are fitting to TS35 rails
Footprint Details
Pin
1
2
3
4
Function
AC(N)
AC(L)
+Vo
-Vo
PACKAGE DIAGRAM
PCB mounting Series
Special Package Series(A2S/A4S)
MORNSUN Science & Technology Co.,Ltd.
Address: No. 5, Kehui St. 1, Kehui development center, Science Ave., Guangzhou Science City, Luogang district, Guangzhou,P.R.China.
Tel: 86-20-38601850
Fax:86-20-38601272
E-mail: [email protected]
Http://www.mornsun-power.com
The copyright and authority for the interpretation of the products are reserved by MORNSUN
Specifications subject to change without notice.
LD01 & LD02
2013.07.09-A/4
Page 5 of 5