5300 Series - Murata Power Solutions

5300 Series
www.murata-ps.com
10A Current Sensing Transformers
SELECTION GUIDE
Min.
Secondary
Turns Ratio
Inductance
mH
1:20
0.08
1:30
0.18
1:40
0.32
1:50
0.50
1:60
0.72
1:70
0.98
1:100
2.00
1:125
3.00
1:150
4.50
1:200
8.00
Order
Code
53020C
53030C
53040C
53050C
53060C
53070C
53100C
53125C
53150C
53200C
FEATURES
Max. DC Resistance
Primary (8-7)
mΩ
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
Secondary (1-3)
Ω
0.55
0.85
1.10
1.75
2.20
4.50
5.60
7.50
17.50
34.00
Isolation Terminating Resistance
Voltage1 to produce 1VOUT/1AIN
Vrms
500
500
500
500
500
500
500
500
500
500
Ω
20
30
40
50
60
70
100
125
150
200
ABSOLUTE MAXIMUM RATINGS
RoHS compliant
Operating free air temperature range
-40°C to 125°C
Primary current rating 10A
Storage temperature range
-40°C to 155°C
20 to 200 turn variants
SOLDERING INFORMATION2
Primary to secondary isolation 500Vrms
Peak reflow solder temperature
250˚C
Pin finish
Tin
Moisture sensitivity level
1
50kHz-500kHz frequency range
Surface mount
PACKAGE SPECIFICATIONS
Industry-standard footprint
Mechanical Dimensions
6
J-STD-020C reflow
PRODUCT OVERVIEW
The 5300 series of current sense
transformers are designed to monitor AC
currents. The transformers can be used
for high frequency current sensing in
applications such as switched-mode power
supplies, motor control, and electronic
lighting ballasts.
5
150
8
1
2
5.4
(0.213)
Max.
4
1.85±0.15
(0.073±0.006)
8.3
0.2±0.1
(0.008±0.004) (0.327)
Max.
7
3
0.2±0.1*
(0.008±0.004)
Weight = 0.34g Typ.
Unless otherwise stated, all dimensions in mm (inches) ±0.25 (0.010).
* True dimension before tin dipping.
Recommended Footprint Details
0.5±0.1
(0.020±0.004)
7.2 (0.283)
Max.
2.0±0.1 (0.079±0.004)
UL94 V-0 package materials
Schematic
1.27 (0.050)
1.52 (0.060)
8
2.69 (0.106)
3.05
(0.120)
5.59
(0.220)
2.54 (0.1)
Primary
7
1
Secondary
3
1.85 (0.073)
For full details go to
www.murata-ps.com/rohs
Unless otherwise stated, all dimensions in mm (inches) ±0.25 (0.010).
Specifications typical at TA = 25°C
1 Flash tested for 1 second.
2 For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KMP_5300C_B03 Page 1 of 2
5300 Series
10A Current Sensing Transformers
PACKAGE SPECIFICATIONS
Reel Dimensions
Ø331 (13.031) Max.
49.75 (1.96) Min.
Ø
15.9-19.4*
(0.626-0.764)
13.50 0.531
Ø
12.50 0.492
Leader Section
400 (15.748) Min.
100 (3.937)
Min.
1.50 (0.059) Min.
22.4
(0.882)
Max.†
Goods
Enclosure
Section
16.3-16.7
(0.642-0.657)†
Trailer Section
160 (6.299) Min.
Ø21.1 (Ø0.83) Min.
All dimensions in mm (inches)
* Includes flange distortion at outer edge
† Measured at hub
Tape Outline Dimensions
1.75 (0.069)
16.0 (0.630)
1.50 (0.059)
7.5 (0.295)
150
150
150
150
Direction of unreeling
12.0
(0.472)
5.8
(0.228)
Reel quantity: 1,000
All dimensions in mm (inches)
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2011 Murata Power Solutions, Inc.
www.murata-ps.com/support
KMP_5300C_B03 Page 2 of 2