Healthcare Applications (Murata)

Latest products:
Healthcare Applications
Click on any link for more information.
About Murata
Murata has been a global innovator in electronics for decades,
producing components which have enabled the advance of modern
electronics for more than 60 years.
We offer an extensive range of electronic components, and are the
reliable one-stop supplier for the building blocks of most electronic
designs.
Our broad product line-up includes:
yy
Ceramic capacitors
yyNoise suppression products
Filters, ferrite cores & ESD protection devices
yyInductors
General purpose, high-frequency, etc.
yyResonators
Ceramic & crystal
yySensors
Thermistor, infrared, ultrasonic, rotary position,
MEMS accelerometer, gyro, pressure, Magneto-resistance, etc.
yySound components
Piezo-electric buzzers
yyMicro-mechatronics
Piezo-electric microblowers
yyRF modules
Bluetooth®, Bluetooth® Low Energy, WiFi®, etc.
yyPower supplies
DC-DC converters, AC-DC converters, switching power supplies, etc.
Please note that Murata does not support
the usage of Murata’s standard products
for safety-critical applications that require
especially high reliability.
Please don’t hesitate to contact us if you
2
have any questions or concerns.
Electronics in healthcare
Contents:
Electronics are permeating more and more into the healthcare sector, and electronics technology advances continue to
enhance the functionality of healthcare equipment.
RF Modules . . . . . . . . . . . . . . . . . . . . . . . . . . Page 4
Power Supplies (AC-DC) . . . . . . . . . . . . Page 5
Murata is at the cutting edge of these electronics advancements
and is a key provider of technologies which will help to shape the
future of healthcare around the world.
Power Supplies (DC-DC) . . . . . . . . . . . . Page 5
Apart from our standard products, which are present in almost
any electronic equipment you use, Murata has developed new,
innovative products specifically for healthcare applications.
Piezo Blower . . . . . . . . . . . . . . . . . . . . . . . . . Page 7
MEMS Inclinometer . . . . . . . . . . . . . . . . . Page 7
In this brochure we outline just a few of these innovations.
Global Locations . . . . . . . . . . . . . . . . . . . . . . Page 8
RFID Technologies . . . . . . . . . . . . . . . . . . . Page 6
RF Modules
Low-power, reliable
connectivity for healthcare
devices
Small Size
Healthcare devices are increasingly connected to each other and the Web.
Use a Murata module for proven RF excellence.
Murata RF modules are small
enough to suit even the most
space-constrained applications
with sizes from 4.8 x 5.8 x 1.0mm.
Murata RF modules make it easy for you to build connectivity into most devices
...even those where space is limited and power consumption needs to stay low.
With BLE (Bluetooth® Low Energy) devices as small as 4.8 x 5.8 x 1.0mm, wireless communication has never been easier to design in.
Footprint:
Contact Murata today to find out how our RF modules could enhance the functionality of your products.
Blood Pressure Meter
Heart Rate Monitor
Weight Scales
Interface
Height:
Features
ÎÎ
Support BLE (Bluetooth® Low
Energy), Bluetooth®, WiFi®, and
other wireless standards
ÎÎ
Combo-modules available
(Bluetooth®/WiFi®, etc.)
ÎÎ
Easy to design in
ÎÎ
Antenna matching supported
Applications
4
Exercise Equipment
ÎÎ
E-health / home monitoring
ÎÎ
Connectivity of healthcare
appliances like blood pressure
meter, glucose meter, etc.
AC-DC Power
Medical Approved
AC-DC Front-End Power Supplies
MVAC, MVAD, MVAB series
40/65/120/250/400W Power Supplies
Convection
Cooling
Forced Air
250LFM
Input
Voltage
Output
Voltage
Efficiency
Dimensions
MVAC250
170W
250W
90-264Vac
12/24/50V
93%
3" x 5" x 1.4"
MVAC400
250W
400W
90-264Vac
12/24/50V
93%
3" x 5" x 1.4"
MVAD040
40W
-
90-264Vac
12/24/48V
89%
2" x 4" x 1.3"
MVAD065
65W*
-
90-264Vac
12/24/48V
90%
2" x 4" x 1.3"
MVAB120 **
75W
120W
91%
2" x 4" x 1.35"
Model No.
Features
ÎÎ
Universal input 90-264Vac
ÎÎ
Active power-factor correction
ÎÎ
Up to 250W natural convection cooling
ÎÎ
-20°C to +70°C full power operating temp.
ÎÎ
Class B conducted EMC
ÎÎ
Aux isolated 12V@1A fan output
ÎÎ
MVAC 250/400: 10W 5V standby power
ÎÎ
MVAD040/065: less than 0.3W at no load
ÎÎ
2 x MOPP (Primary-Secondary)
ÎÎ
1 x MOPP (Secondary-Chassis/Earth Enclosure
40W
250W
120W
MVAB Series
ÎÎ
IEC 60601-1 (3rd edition) MOOP
ÎÎ
UL60950
Applications
ÎÎ
Battery powered systems
ÎÎ
Process control systems
ÎÎ
High reliability systems
5
80
®
GOLD
Advanced component
and circuit technology
delivers medical-approved
80 PLUS Gold® efficiency up to 94%
ÎÎ
Mains-powered medical equipment
Quality/Safety
400W
PLUS
Applications
ÎÎ
High efficiency across the full load range
ÎÎ
Op. temp. range: -40 to 85
ÎÎ
Encapsulated: superior thermal performance
ÎÎ
72-79% typ. efficiency
ÎÎ
3.5 - 5% typ. load regulation
www.murata-ps.com/ac-dc
MVAC Series
ÎÎ
60601 (3rd edition) MOPP, 60950
safety approval
ÎÎ
2 year warranty
Features
*Output 12V: up to 60W
** Medical approved part no. ends with -01
65W
MVAD Series
Quality/Safety
DC-DC Power
90-264Vac 12/24/28/48V
MEJ DC-DC converter
Medical approved 1W/2W
Industry standard, pin compatible 1W and 2W converters
maintaining high levels of efficiency at light loads
Series name Isolation
Dimensions (mm)
Power Rating
MEJ1
5200Vdc 3.3/5//12/15/24V 3.3/5/9/12/15V 69-78%
Input Voltage
9.95 x 19.65 x 12.65
1W
MEJ2
5200Vdc
9.95 x 19.65 x 12.65
2W
3.3/5//12/15V
Output Voltage Efficiency
3.3/5/9/12/15V 70-82%
RFID Technologies
Track, trace, and verify –
with ultra-miniature UHF RFID tags
Whether your focus is on anti-counterfeiting, inventory
management, or process control, MAGICSTRAP® offers you
an integrated solution with a tag size which can meet the
challenges of almost any application.
At only 2.0 x 1.2 (LXMS21) and 3.2 x 1.6 (LXMS31), the MAGICSTRAP® UHF IC
module is one of the smallest in the world. It can be mounted onto, or embedded into, a wide variety of materials even in non-electronic products, and can be
surface-mounted directly onto your PCB for use in medical electronics.
In association with partner companies offering hardware & software solutions, we
are able to provide a fully integrated system that gives you massive read/write
functionality all built around an unbelievably small module.
Applications
ÎÎ
Anti-counterfeit
ÎÎ
Process control/traceability of medical electronics
ÎÎ
Tracking/tracing PCBs
ÎÎ
Inventory management in healthcare institutions
ÎÎ
Probe tracking
6
Small Size
2.0 x 1.2 (LXMS21) or
3.2 x 1.6 (LXMS31),
surface-mounted device
Features
ÎÎ
RF circuitry incorporated in LTCC substrate
ÎÎ
Read range:
- Up to 2cm using the component alone*
- Up to 7m with external antenna
ÎÎ
Can be mounted on many surfaces
ÎÎ
Can be embedded into many materials
ÎÎ
Small SMD: 2.0 x 1.2 (LXMS21) and
3.2 x 1.6 (LXMS31)
ÎÎ
Complies with EPCglobal C1G2, ISO 18000-6C
*Loop type antenna for reader/writer is required
Construction
UHF RFID IC
LTCC Substrate
containing RF circuitry
Resin
cover
Piezo Ceramics
Microblower MZB Series
Piezo ceramics enable
high-pressure air discharge
Features
Applications
ÎÎ
Utilizes ultrasonic vibration of piezo
ceramic material
ÎÎ
Can “blow” or “suck” for air/gas
circulation or pumping
ÎÎ
Extremely small and thin
ÎÎ
Low power consumption
ÎÎ
Drive Frequency: 26 kHz
ÎÎ
Flow Rate: 1L/min (@15Vp-p)
ÎÎ
Static Pressure: 1900Pa (@15Vp-p)
ÎÎ
Discharge, suction or
circulation of air/gas
ÎÎ
Transfer of liquids using
air-pump mechanism
ÎÎ
Localized cooling
ÎÎ
Aroma dispensing
Small Size
Intake Channel
Diaphragm
Piezoelectric Element
Pumping Chamber
20 x 20mm x 1.85mm height
MEMS Sensors
Inclinometers
High accuracy leveling and inclination
measurement with high reliability
Features
ÎÎ
High reliability, low noise
ÎÎ
Excellent stability over time
ÎÎ
Long lifetime
ÎÎ
Automotive grade quality
Applications
ÎÎ
Diagnostic equipment (X-ray, MRI, etc.)
ÎÎ
Surgery tables
ÎÎ
Hospital beds
ÎÎ
Treatment equipment
+X
+X
1g
7
θ
1g
Healthcare
Global locations
For details please visit www.murataamericas.com
Note
For customers outside Japan:
No Murata products should be used or sold,
through any channels, for use in the design,
development, production, utilization, maintenance
or operation of, or otherwise contribution to (1)
any weapons (Weapons of Mass Destruction
[nuclear, chemical or biological weapons or
missiles] or conventional weapons) or (2) goods or
systems specially designed or intended for military
end-use or utilization by military end-users.
For customers in Japan:
For products which are controlled items subject
to the “Foreign Exchange and Foreign Trade Law”
of Japan, the export license specified by the law is
required for export.
2 Please contact our sales representatives or
product engineers before using the products in
this catalog for the applications listed below,
which require especially high reliability for the
prevention of defects which might directly
damage a third party’s life, body or property, or
when one of our products is intended for use in
applications other than those specified in this
catalog.
Murata Manufacturing Co., Ltd.
www.murata.com
1
Aircraft equipment
2
Undersea equipment
3
Medical equipment
4
Traffic signal equipment
5
Data-processing equipment
6
Aerospace equipment
7
Power plant equipment
8
Transportation equipment
(vehicles, trains, ships, etc.)
9
Disaster prevention /
crime prevention equipment
10
Application of similar complexity and/or
reliability requirements to the applications
listed above
3 Product specifications in this catalog are as of
August 2013. They are subject to change or our
products in it may be discontinued without advance
notice. Please check with our sales representatives
or product engineers before ordering. If there are any
questions, please contact our sales representatives
or product engineers.
4 Please read rating and & CAUTION (for storage,
operating, rating, soldering, mounting and
handling) in this catalog to prevent smoking
and/or burning, etc.
5 This catalog has only typical specifications.
Therefore, please approve our product
specifications or transact the approval sheet
for product specifications before ordering.
6 Please note that unless otherwise specified, we
shall assume no responsibility whatsoever for any
conflict or dispute that may occur in connection
with the effect of our and/or a third party’s
intellectual property rights and other related rights
in consideration of your use of our products and/or
information described or contained in our catalogs.
In this connection, no representation shall be made
to the effect that any third parties are authorized
to use the rights mentioned above under licenses
without our consent.
7 No ozone depleting substances (ODS) under the
Montreal Protocol are used in our manufacturing
process.
© June 2014 Murata Americas
1 Export Control