Latest products: Healthcare Applications Click on any link for more information. About Murata Murata has been a global innovator in electronics for decades, producing components which have enabled the advance of modern electronics for more than 60 years. We offer an extensive range of electronic components, and are the reliable one-stop supplier for the building blocks of most electronic designs. Our broad product line-up includes: yy Ceramic capacitors yyNoise suppression products Filters, ferrite cores & ESD protection devices yyInductors General purpose, high-frequency, etc. yyResonators Ceramic & crystal yySensors Thermistor, infrared, ultrasonic, rotary position, MEMS accelerometer, gyro, pressure, Magneto-resistance, etc. yySound components Piezo-electric buzzers yyMicro-mechatronics Piezo-electric microblowers yyRF modules Bluetooth®, Bluetooth® Low Energy, WiFi®, etc. yyPower supplies DC-DC converters, AC-DC converters, switching power supplies, etc. Please note that Murata does not support the usage of Murata’s standard products for safety-critical applications that require especially high reliability. Please don’t hesitate to contact us if you 2 have any questions or concerns. Electronics in healthcare Contents: Electronics are permeating more and more into the healthcare sector, and electronics technology advances continue to enhance the functionality of healthcare equipment. RF Modules . . . . . . . . . . . . . . . . . . . . . . . . . . Page 4 Power Supplies (AC-DC) . . . . . . . . . . . . Page 5 Murata is at the cutting edge of these electronics advancements and is a key provider of technologies which will help to shape the future of healthcare around the world. Power Supplies (DC-DC) . . . . . . . . . . . . Page 5 Apart from our standard products, which are present in almost any electronic equipment you use, Murata has developed new, innovative products specifically for healthcare applications. Piezo Blower . . . . . . . . . . . . . . . . . . . . . . . . . Page 7 MEMS Inclinometer . . . . . . . . . . . . . . . . . Page 7 In this brochure we outline just a few of these innovations. Global Locations . . . . . . . . . . . . . . . . . . . . . . Page 8 RFID Technologies . . . . . . . . . . . . . . . . . . . Page 6 RF Modules Low-power, reliable connectivity for healthcare devices Small Size Healthcare devices are increasingly connected to each other and the Web. Use a Murata module for proven RF excellence. Murata RF modules are small enough to suit even the most space-constrained applications with sizes from 4.8 x 5.8 x 1.0mm. Murata RF modules make it easy for you to build connectivity into most devices ...even those where space is limited and power consumption needs to stay low. With BLE (Bluetooth® Low Energy) devices as small as 4.8 x 5.8 x 1.0mm, wireless communication has never been easier to design in. Footprint: Contact Murata today to find out how our RF modules could enhance the functionality of your products. Blood Pressure Meter Heart Rate Monitor Weight Scales Interface Height: Features ÎÎ Support BLE (Bluetooth® Low Energy), Bluetooth®, WiFi®, and other wireless standards ÎÎ Combo-modules available (Bluetooth®/WiFi®, etc.) ÎÎ Easy to design in ÎÎ Antenna matching supported Applications 4 Exercise Equipment ÎÎ E-health / home monitoring ÎÎ Connectivity of healthcare appliances like blood pressure meter, glucose meter, etc. AC-DC Power Medical Approved AC-DC Front-End Power Supplies MVAC, MVAD, MVAB series 40/65/120/250/400W Power Supplies Convection Cooling Forced Air 250LFM Input Voltage Output Voltage Efficiency Dimensions MVAC250 170W 250W 90-264Vac 12/24/50V 93% 3" x 5" x 1.4" MVAC400 250W 400W 90-264Vac 12/24/50V 93% 3" x 5" x 1.4" MVAD040 40W - 90-264Vac 12/24/48V 89% 2" x 4" x 1.3" MVAD065 65W* - 90-264Vac 12/24/48V 90% 2" x 4" x 1.3" MVAB120 ** 75W 120W 91% 2" x 4" x 1.35" Model No. Features ÎÎ Universal input 90-264Vac ÎÎ Active power-factor correction ÎÎ Up to 250W natural convection cooling ÎÎ -20°C to +70°C full power operating temp. ÎÎ Class B conducted EMC ÎÎ Aux isolated 12V@1A fan output ÎÎ MVAC 250/400: 10W 5V standby power ÎÎ MVAD040/065: less than 0.3W at no load ÎÎ 2 x MOPP (Primary-Secondary) ÎÎ 1 x MOPP (Secondary-Chassis/Earth Enclosure 40W 250W 120W MVAB Series ÎÎ IEC 60601-1 (3rd edition) MOOP ÎÎ UL60950 Applications ÎÎ Battery powered systems ÎÎ Process control systems ÎÎ High reliability systems 5 80 ® GOLD Advanced component and circuit technology delivers medical-approved 80 PLUS Gold® efficiency up to 94% ÎÎ Mains-powered medical equipment Quality/Safety 400W PLUS Applications ÎÎ High efficiency across the full load range ÎÎ Op. temp. range: -40 to 85 ÎÎ Encapsulated: superior thermal performance ÎÎ 72-79% typ. efficiency ÎÎ 3.5 - 5% typ. load regulation www.murata-ps.com/ac-dc MVAC Series ÎÎ 60601 (3rd edition) MOPP, 60950 safety approval ÎÎ 2 year warranty Features *Output 12V: up to 60W ** Medical approved part no. ends with -01 65W MVAD Series Quality/Safety DC-DC Power 90-264Vac 12/24/28/48V MEJ DC-DC converter Medical approved 1W/2W Industry standard, pin compatible 1W and 2W converters maintaining high levels of efficiency at light loads Series name Isolation Dimensions (mm) Power Rating MEJ1 5200Vdc 3.3/5//12/15/24V 3.3/5/9/12/15V 69-78% Input Voltage 9.95 x 19.65 x 12.65 1W MEJ2 5200Vdc 9.95 x 19.65 x 12.65 2W 3.3/5//12/15V Output Voltage Efficiency 3.3/5/9/12/15V 70-82% RFID Technologies Track, trace, and verify – with ultra-miniature UHF RFID tags Whether your focus is on anti-counterfeiting, inventory management, or process control, MAGICSTRAP® offers you an integrated solution with a tag size which can meet the challenges of almost any application. At only 2.0 x 1.2 (LXMS21) and 3.2 x 1.6 (LXMS31), the MAGICSTRAP® UHF IC module is one of the smallest in the world. It can be mounted onto, or embedded into, a wide variety of materials even in non-electronic products, and can be surface-mounted directly onto your PCB for use in medical electronics. In association with partner companies offering hardware & software solutions, we are able to provide a fully integrated system that gives you massive read/write functionality all built around an unbelievably small module. Applications ÎÎ Anti-counterfeit ÎÎ Process control/traceability of medical electronics ÎÎ Tracking/tracing PCBs ÎÎ Inventory management in healthcare institutions ÎÎ Probe tracking 6 Small Size 2.0 x 1.2 (LXMS21) or 3.2 x 1.6 (LXMS31), surface-mounted device Features ÎÎ RF circuitry incorporated in LTCC substrate ÎÎ Read range: - Up to 2cm using the component alone* - Up to 7m with external antenna ÎÎ Can be mounted on many surfaces ÎÎ Can be embedded into many materials ÎÎ Small SMD: 2.0 x 1.2 (LXMS21) and 3.2 x 1.6 (LXMS31) ÎÎ Complies with EPCglobal C1G2, ISO 18000-6C *Loop type antenna for reader/writer is required Construction UHF RFID IC LTCC Substrate containing RF circuitry Resin cover Piezo Ceramics Microblower MZB Series Piezo ceramics enable high-pressure air discharge Features Applications ÎÎ Utilizes ultrasonic vibration of piezo ceramic material ÎÎ Can “blow” or “suck” for air/gas circulation or pumping ÎÎ Extremely small and thin ÎÎ Low power consumption ÎÎ Drive Frequency: 26 kHz ÎÎ Flow Rate: 1L/min (@15Vp-p) ÎÎ Static Pressure: 1900Pa (@15Vp-p) ÎÎ Discharge, suction or circulation of air/gas ÎÎ Transfer of liquids using air-pump mechanism ÎÎ Localized cooling ÎÎ Aroma dispensing Small Size Intake Channel Diaphragm Piezoelectric Element Pumping Chamber 20 x 20mm x 1.85mm height MEMS Sensors Inclinometers High accuracy leveling and inclination measurement with high reliability Features ÎÎ High reliability, low noise ÎÎ Excellent stability over time ÎÎ Long lifetime ÎÎ Automotive grade quality Applications ÎÎ Diagnostic equipment (X-ray, MRI, etc.) ÎÎ Surgery tables ÎÎ Hospital beds ÎÎ Treatment equipment +X +X 1g 7 θ 1g Healthcare Global locations For details please visit www.murataamericas.com Note For customers outside Japan: No Murata products should be used or sold, through any channels, for use in the design, development, production, utilization, maintenance or operation of, or otherwise contribution to (1) any weapons (Weapons of Mass Destruction [nuclear, chemical or biological weapons or missiles] or conventional weapons) or (2) goods or systems specially designed or intended for military end-use or utilization by military end-users. For customers in Japan: For products which are controlled items subject to the “Foreign Exchange and Foreign Trade Law” of Japan, the export license specified by the law is required for export. 2 Please contact our sales representatives or product engineers before using the products in this catalog for the applications listed below, which require especially high reliability for the prevention of defects which might directly damage a third party’s life, body or property, or when one of our products is intended for use in applications other than those specified in this catalog. Murata Manufacturing Co., Ltd. www.murata.com 1 Aircraft equipment 2 Undersea equipment 3 Medical equipment 4 Traffic signal equipment 5 Data-processing equipment 6 Aerospace equipment 7 Power plant equipment 8 Transportation equipment (vehicles, trains, ships, etc.) 9 Disaster prevention / crime prevention equipment 10 Application of similar complexity and/or reliability requirements to the applications listed above 3 Product specifications in this catalog are as of August 2013. They are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. If there are any questions, please contact our sales representatives or product engineers. 4 Please read rating and & CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc. 5 This catalog has only typical specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 6 Please note that unless otherwise specified, we shall assume no responsibility whatsoever for any conflict or dispute that may occur in connection with the effect of our and/or a third party’s intellectual property rights and other related rights in consideration of your use of our products and/or information described or contained in our catalogs. In this connection, no representation shall be made to the effect that any third parties are authorized to use the rights mentioned above under licenses without our consent. 7 No ozone depleting substances (ODS) under the Montreal Protocol are used in our manufacturing process. © June 2014 Murata Americas 1 Export Control