OBSOLETE - power, Murata

www.murata-ps.com
NMPD01 Series
OBSOLETE
Power
ow Over Ethernet PD Module
SELECTION GUIDE
Order Code
Nominal Input
Voltage
V
Output
Voltage
V
Efficiency1
(Min.)
%
Power
(Max.)
W
NMPD0103C
NMPD0105C
NMPD0112C
NMPD0115C
48
48
48
48
3.4
5.1
12.1
15.1
74
77
80
79
9.50
9.75
10.00
10.00
INPUT CHARACTERISTICS
Parameter
FEATURES
„
RoHS Compliant
„
IEEE802.3af full functional compliance
„
Short circuit protection
„
Isolated DC out
„
3.3V, 5V, 12V & 15V output options
„
On board UL recognised DC/DC converter
Specified operating range
Turn on threshold
Turn off threshold
Input reflected ripple
802.3af Power classification
Signature resistance
Signature capacitance
Classification current
Conditions
Voltage rising
Voltage falling
Min.
36
36
30
Typ.
Max.
40
31
57
42
33
50
Units
mV p-p
V
Class 0
23.75
50
100
26.25
120
4
kΩ
nF
mA
Min.
Typ.
Max.
Units
1.6
%
OUTPUT CHARACTERISTICS
Parameter
Conditions
Voltage set point accuracy
100% load after 30 mins at nominal
supply voltage
„
UL 94V-0 flammability
Overall voltage error
Case temperature -40ºC to 110ºC
Load 0% - 100%
Input specified range
1
2.5
%
PRODUCT OVERVIEW
Temperature coefficient of output
voltage (slope)
Over any 10ºC span within the
specified temperature range
50
250
ppmºC
Deviation of output voltage
Specified over temperature MINMAX
0.5
1
%
0.05
0.1
0.5
„
Thermal shutdown
„
Output voltage present LED
The NMPD01 series of power extraction modules
has full functional compliance with IEEE802.3af.
They are designed to extract power from CAT5
Ethernet cable when sourced by a Power Sourcing
Equipment (PSE) also conforming to IEEE802.3af.
The NMPD01 series removes the need for
localised equipment power source, significantly
reducing installation costs. The IEEE802.3af
standard allows for two power options, one on the
data lines, the other on the spare pair (see figures
1 and 2). The NMPD01 series can have voltage
input on the data lines or spare pairs.
The NMPD01 series provides full signature and
control as required by the PSE.
Line regulation
Load Regulation
Ripple
Switching frequency
Operating voltage range, 50% load
0% - 100% rated load
rms
330
70
350
395
%
%
mV
kHz
Min.
Typ.
Max.
Units
COUPLING CHARACTERISTICS
Parameter
Conditions
Insertion loss
1-100MHz
1-30MHz, at 100Ω
40MHz, at 100Ω
50MHz, at 100Ω
60-80MHz, at 100Ω
30MHz
60MHz
100MHz
30MHz
60MHz
100MHz
Return Loss
Differential to common mode
rejection
Cross talk
DC resistance balance
-1.2
-16
-14
-13
-12
-43
-37
-33
-45
-40
-35
dB
≤3.5%
ABSOLUTE MAXIMUM RATINGS
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Input voltage
Output voltage
±60V
-0.3V to controlled output voltage (operating or non-operating)
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
1. Nominal VIN, full load.
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KII_NMPD01.E01 Page 1 of 5
NMPD01 Series
Power Over Ethernet PD Module
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Flash tested for 60 seconds
1500
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Ambient temperature
DC/DC case temperature
Storage
Relative humidity
Thermal protection
Min.
0
-40
-40
Full load
Absolute Max. internal temperature
Non condensing 85ºC
Operates at case temperature
Typ.
Max.
Units
VAC rms
Typ.
Max.
Units
70
110
125
85
ºC
%
ºC
110
THERMAL CHARACTERISTICS
Max. power rating with case temperature maintained by external means (e.g. forced air cooling).
Part Number
NMPD0103C
NMPD0105C
NMPD0112C
NMPD0115C
100ºC
Case Temperature
105ºC
110ºC
9.5
9.75
10
10
7.0
4.7
8.0
7.5
1.0
1.0
0
0
Units
W
DC/DC THERMAL PERFORMANCE
12
Output Power (W)
10
8
NMPD0103C
NMPD0105C
NMPD0112C
6
NMPD0115C
4
2
0
-40
-20
0
20
40
60
80
100
120
Ambient Temperature (ºC)
www.murata-ps.com
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KII_NMPD01.E01 Page 2 of 5
NMPD01 Series
Power Over Ethernet PD Module
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NMPD01 series of power over ethernet modules are all 100% production tested at their stated isolation voltage. This is 1500VAC for 60 seconds.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NMPD01 series has an on-board DC/DC converter, that has been recognized by Underwriters Laboratory. Both input and output should normally be maintained within SELV
limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a
safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry
on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any
user-accessible circuitry according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. While manufactured parts can withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any
material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of
tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from
specified test voltage.
APPLICATION NOTES
The NMPD01 series are ideal modular system blocks for integration into numerous ethernet products to be powered from the data lines. These modules eliminate the need for
localised powering saving considerable installation costs and time. These modules are ideal for applications where powering from the PSE at an SELV level is highly desirable such
as in harsh industrial environments (chemicals and moisture).
Offering a module solution, incorporating ethernet isolation transformers, full compatibility signature to the PSE and isolated on-board DC/DC converter the NMPD01 series offers
simple and quicker product development, maximising return on investment. PoE is the emerging standard in what is in effect the widest form of distributed power architecture.
Power-Up Sequence
A PSE applies two separate input voltages of <10V and calculates the signature resistance and signature capacitance of the POE device. If it is in the valid range, the PSE
then applies a voltage between 14.5V and 20.5V and measures the classification current. If the classification current is between 0-4mA it is classification O.
PSE applies full operating voltage 42-57V, detection circuitry within NMPD01 senses correct voltage and turns on on-board DC/DC converter. If input voltage falls outside
specified operating range, the on-board DC/DC converter is disabled.
Maximum Power
If the maximum output power is exceeded, the NMPD01 will operate in over current mode and will auto recover when the over load condition is removed.
Application Sectors
„
„
„
„
„
„
„
Security system, door access, cameras, alarms
Displays
Public address systems
Wireless access point
Environmental control
Telemetry
Remote environmental monitoring
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of
300ºC for 10 seconds. The pin termination finish is Tin. They are backward compatible with Sn/Pb
soldering systems.
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KII_NMPD01.E01 Page 3 of 5
NMPD01 Series
Power Over Ethernet PD Module
TYPICAL CONFIGURATIONS
Figure 1 - IEEE802.3af Power Configurations
108&34063$*/(
&26*1.&/514&
Figure 2 - IEEE802.3af Power Configurations
3+
108&34063$*/(
&26*1.&/514&
/.1%
3+
/.1%
1
41"3&1"*3
1
o
7
5Y
1
3Y
1
1
1
o
1
39
1
5Y
4*(/"-1"*3
7
1
%$%$
$POWFSUFS
1
59
1
4*(/"-1"*3
o
41"3&1"*3
1
4*(/"-1"*3
%$%$
$POWFSUFS
3Y
1
4*(/"-1"*3
1
41"3&1"*3
41"3&1"*3
Signal lines carry both data and power.
Polarity of power is not important ... for both
Spare pairs carry power, data lines carry data only.
Figure 3 - Typical non-powered coupling between CAT5 and Physical Layer Interface (PHY)
4 SP1+
5 SP1RX-
RD-
1:1
6 RXRXCT
RCT
RX+
RD+
3 RX+
RJ45
2 TX-
TX-
7 SP2+
8 SP2-
TD-
1:1
1 TX+
Physical
Layer
Interface
TXCT
TCT
TX+
TD+
Figure 4 - Typical power coupling using the NMPD01
NMPD01
P1
1
4 SP1+
2
SP1
SP2
P3, 1-4
+DC/DC
TXCT
RXCT
5 SP1-
3
RX-
6 RX-
1:1
RJ45
2 TX-
RXCT
7 SP2+
5
3
RD+
TX-
8
TXCT
8 SP2-
7
TX+
www.murata-ps.com
RDCT
RX+
6
1 TX+
RD-
6
4
3 RX+
P3, 5-8
P2
5
1:1
Physical
Layer
Interface
4
TD-
2
TDCT
1
TD+
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KII_NMPD01.E01 Page 4 of 5
NMPD01 Series
Power Over Ethernet PD Module
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
%$%$DPOWFSUFSQBSU
OVNCFSNBSLJOH
$BTFUFNQFSBUVSF
NFBTVSFNFOUQPJOU
0VUQVUWPMUBHF
QSFTFOU-&%
."9
1
1
1
0.1 (2.54)
P1
0.025 (0.64)
P2
2
8
2
8
1
7
1
7
P3
0.025
(0.64)
0.1 (2.54)
2
8
1
7
0.5650
(14.35)
NMPD part number marking
Typical package weight: 35.6g
All dimensions in inches ±0.01 (mm ±0.25)
PIN CONNECTIONS
P1 - Data/power input
1 ‘B’ +ve
2 ‘B’ -ve
3 RX4 RXct
5 RX+
6 TX7 TX+
8 TXct
P2 - Data out
P3 - Power out
1 TD+
2 TDct
3 RD+
4 TD5 RD6 RDct
7 N/C
8 N/C
1 +ve
2 +ve
3 +ve
4 +ve
5 -ve
6 -ve
7 -ve
8 -ve
RECOMMENDED FOOTPRINT
 )0-&4
The NMPD series is not suitable for aqueous washing.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
www.murata-ps.com/locations
All dimensions in inches ±0.01 (mm ±0.25). All pins on a 0.1 (2.54) pitch.
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2011 Murata Power Solutions, Inc.
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KII_NMPD01.E01 Page 5 of 5