WPN20R48S05C - power, Murata

www.murata-ps.com
WPN20
OBSOLETE
20W
0W Regulated DC/DC Converter
SELECTION GUIDE
Order Code
Input Voltage Output
Voltage
Nom.
V
V
WPN20R48S05C
WPN20R12S05C
WPN20R12S12C
WPN20R12D12C
WPN20R24S03C
WPN20R24S05C
WPN20R24S12C
WPN20R24D12C
WPN20R24D15C
WPN20R48S12C
WPN20R48D12C
WPN20R48D15C
FEATURES
„
RoHS compliant
„
Operating temperature range: -40ºC to
+100ºC
Output Current
Min.
Nom.
A
A
Input Current
Efficiency
Nom. Load
A
%
Recommeneded
Alternative
UWR-5/4000-D48A-C
UWR-5/4000-D12A-C
UWR-12/1650-D12A-C
BWR-12/830-D12A-C
UWR-3.3/4850-D12A-C
UWR-5/4000-D12A-C
UWR-12/1650-D12A-C
BWR-12/830-D12A-C
BWR-15/670-D12A-C
UWR-12/1650-D48A-C
BWR-12/830-D48A-C
BWR-15/670-D48A-C
Obsolete, recommended alternative:
(click to view data sheets)
INPUT CHARACTERISTICS
„
Industry standard pinout
Parameter
Conditions
Min.
Typ.
Max.
„
Input and output filtering
Voltage range
All WPN20R12 types
All WPN20R24 types
All WPN20R48 types
9
18
33
12
24
48
mA p-p
All WPN20R12 types
All WPN20R24 types
All WPN20R48 types
7
15.5
30
18
36
75
50
8.8
17
33
Typ.
Max.
Units
60
50
20
±1.5
±0.005
±0.1
±0.5
±0.5
±2.0
100
100
W
%
%/ºC
%
%
%
%
mVp-p
mVp-p
Typ.
Max.
Units
„
Low profile shell
„
Single and dual outputs
„
Output trim function
DESCRIPTION
Reflected ripple current
Undervoltage lockout
threshold
Units
V
V
OUTPUT CHARACTERISTICS
The WPN20RC series is available in three input
voltage ranges of 9-18V, 18-36V and 33-75V. The
unit is housed in a space saving aluminum shell.
The 300KHz switching frequency and forward
converter topology provide excellent performance
across all line and load conditions. Other features
include: under voltage lock-out, internal temperature shutdown, soft start and over current
protection.
Parameter
An output trim feature is provided, allowing the
user to compensate for long line lengths.
Ripple & Noise
Applications include: Telecommunications, Battery
Powered Sytems, Process Control Equipment,
Transportation Equipment and Distributed Power
Systems.
Short circuit &
overcurrent protection
The product range has been recognised by Underwriters Laboratory (UL) to UL 1950 for operational
insulation, file number E179522 applies.
Conditions
Min.
Rated power
Voltage setpoint accuracy
Temperature coefficient
Line regulation
Load regulation
Output voltage adjust range
Singles
Duals
Singles
Min load to
Nom. load
Duals
Single outputs, BW = 5Hz to 20MHz
Dual outputs, BW = 5Hz to 20MHz
See attached plots
High line to low line
Continuous
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
Max capacitive load
MTTF per ML-HDBK-217
Ground benign
Circuit stress method
TA = +25º unmodified database
Min.
300
550
kHz
mF/A
1.4
MHr
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KDC_WPN20RC.E01 Page 1 of 5
WPN20
20W Regulated DC/DC Converter
ISOLATION CHARACTERISTICS
Parameter
Conditions
Rated voltage
Test voltage
Resistance
Capacitance
Min.
Typ.
Max.
1500
1500
10
2400
60Hz, 10 seconds
Units
Vpk
Vpk
GΩ
pF
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Operation
Storage
Thermal shutdown
Ambient (with no derating)
Case (with no derating)
-40
-40
-55
105
Case
Typ.
Max.
Units
+85
+100
+125
115
°C
°C
°C
°C
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC
for 10 seconds. The pin termination finish on this product series is matte tin (100 microns min.) over
nickel (40-80 microinches min.). The series is backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
THERMAL DERATING CURVE
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions WPN20 series of dc/dc converters are all 100% production tested at their stated isolation voltage. This is 1500 Vpk for 10 seconds.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The WPN20 series has been recognized by Underwriters Laboratory, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC.
The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be
expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded
as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard
requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. While manufactured parts can withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any
material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of
tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from
specified test voltage.
www.murata-ps.com
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KDC_WPN20RC.E01 Page 2 of 5
WPN20
20W Regulated DC/DC Converter
APPLICATION NOTES
OUTPUT VOLTAGE ADJUSTMENT
The trim resistor equations are:
Where:
RDOWN = G - (VOUT x H)
VOUT - VNOM*
RUP
= G - (VOUT x K)
VOUT - VNOM*
VNOM
3.3V
5V
12V
15V
G
27604
8250
235050
362450
H
7500
1100
17800
2200
K
9280
2200
21700
26990
*Note: For 3.3V outputs, VNOM is 3.327V and for 15V outputs VNOM is 14.967V.
TRIM UP SINGLE
TRIM DOWN SINGLE
+VIN
+VOUT
+VOUT
+VIN
RDOWN
WPN20
TRIM
WPN20
TRIM
RUP
-VOUT
TRIM UP DUAL
-VOUT
TRIM DOWN DUAL
+VIN
+VOUT
+VOUT
+VIN
RDOWN
WPN20
TRIM
WPN20
TRIM
RUP
Common
-VOUT
Common
-VOUT
When the output voltage is trimmed up, output current must be derated so that the maximum output power (shown in the selection table) is not
exceeded.
FUSING
The WPN20R Series of converters are not internally fused. In order to maintain maximum safety an input line fuse should always be included. A slow blow, UL listed, 8A fuse
is recommended for all models.
Remote on/off
The WPN20R Series of converters are equipped with a primary on/off control pin for increased system flexibility. The input is TTL open-collector and/or CMOS open-drain
compatible. The primary on/off pin uses positive logic, which turns the unit off when a logic low signal is applied (<0.7V). The figure below illustrates the typical external
connections to enable this function. If no connection is made to the primary on/off control pin, the module will operate normally.
www.murata-ps.com
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KDC_WPN20RC.E01 Page 3 of 5
WPN20
20W Regulated DC/DC Converter
PERFORMANCE GRAPHS
()),&,(1&<96287387/2$'
15V
12V
5V
3V
85
(I¿FLHQF\
80
75
70
65
60
55
50
10
20
40
50
60
80
()),&,(1&<967(03(5$785(
10
&KDQJHLQ(I¿FLHQF\
90
5
100% Load
20% Load
0
-5
-10
-40
100
-15
25
2XWSXW/RDGRU5DWHG
65
110
7FDVH&
50%Load
()),&,(1&<96,138792/7$*(
0.6
Change in Efficiency (%)
2873875,33/(96,138792/7$*(
10%Load
0.4
100%Load
1RUPDOL]HG2XWSXW5LSSOH
0.2
0
-0.2
-0.4
-0.6
-0.8
-1
LL
Nom
HL
Vin
1
0.8
0.6
0.4
LL
5 5
3 -trim +trim
Nom
HL
2873875,33/(967(03(5$785(
1.2
45
1RUPDOL]HG2XWSXW5LSSOH
40
7ULP5HVLVWRU.2KPV
1.2
Vin
75,05(6,67259628738792/7$*(&+$1*(
50
1.4
35
30
25
20
15
10
5
1
0.8
0.6
-40
-15
25
65
110
0
10
9
8
7
6
5
4
3
2
1
3HUFHQWDJH&KDQJH,Q2XWSXW9ROWDJH
75,05(6,67259628738792/7$*(&+$1*(
100
7FDVH&
12 15 15
+trim -trim trim
90
7ULP5HVLVWRU.2KPV
80
70
60
50
40
30
20
10
0
10
9
8
7
6
5
4
3
2
1
3HUFHQWDJH&KDQJH,Q2XWSXW9ROWDJH
www.murata-ps.com
Technical enquiries email: [email protected], tel: +44 (0)1908 615232
KDC_WPN20RC.E01 Page 4 of 5
81/
20W Regulated DC/DC Converter
MECHANICAL DIMENSTIONS
SIDE VIEW
PIN SIDE DOWN
1.590 ± 0.005
(40.39 ± 0.13)
0.425 ± 0.00
(10.80 ± 0.08)
WPN20RxxyzzC
0.150
(3.81)
0.040 ± 0.002
(1.02 ± 0.05)
0.015 ± 0.003
(0.38 ± 0.08)
5
1.990 ± 0.005
(50.55 ± 0.13)
6
1
2
7
4
PIN CONNECTIONS
8
Function
Pin
1
Singles
Duals
+VIN
+VIN
2
-VIN
-VIN
4
Remote on/off
Remote on/off
5
NO PIN
+VOUT
6
+VOUT
OV
7
-VOUT
-VOUT
8
TRIM
TRIM
PIN SIDE UP
Weight: 32g
All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position.
Unless otherwise stated all dimensions are in inches (mm) ±0.01 (0.25).
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/locations
KDC_WPN20RC.E01 Page 5 of 5