NMG Series - power, Murata

NMG Series
www.murata-ps.com
Isolated 2W Single Output DC/DC Converters
mVp-p
%
%
pF
kHrs
81
84
84
84
82
81
83
85
85
84
80
82
84
84
80
84
84
85
83
86.5
87.5
87.5
85
83.5
87
88
88
86.5
83
86.5
87.5
88
84
87.5
88
88.5
33
40
40
40
35
40
61
74
68
60
40
55
65
75
45
55
75
85
3956
3682
3299
2833
2189
2519
2405
2235
2011
2189
3963
3176
2875
2483
3659
2496
3824
3500
„
Internal SMD construction
NMG0505SC
NMG0509SC
NMG0512SC
NMG0515SC
NMG0524SC
NMG1205SC
NMG1209SC
NMG1212SC
NMG1215SC
NMG1224SC
NMG1505SC
NMG1509SC
NMG1512SC
NMG1515SC
NMG2405SC
NMG2409SC
NMG2412SC
NMG2415SC
„
Fully encapsulated with toroidal
magnetics
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
„
No external components required
INPUT CHARACTERISTICS
„
MTTF up to 3.9 million hours
Parameter
Conditions
Min.
Typ.
Max.
„
No electrolytic or tantalum capacitors
Voltage range
Continuous operation, 5V input types
Continuous operation, 12V input types
Continuous operation, 15V input types
Continuous operation, 24V input types
4.5
10.8
13.5
21.6
PRODUCT OVERVIEW
Reflected ripple current
5
12
15
24
7.5
5.5
13.2
16.5
26.4
15
mA p-p
The NMG series of DC/DC Converters is
particularly suited to isolating and/or converting
DC power rails. The galvanic isolation allows the
device to be configured to provide an isolated
negative rail in systems where only positive rails
exist. The wide temperature range guarantees
startup from –40°C and full 2 watt output at 85°C.
Pin compatibility with the NMR and MER1 series
ensures ease of upgradeability.
ABSOLUTE MAXIMUM RATINGS
Max.
Units
2
W
1.2
%/%
FEATURES
„
UL 60950 recognised
„
Efficiency from 80%
„
Wide temperature performance at full
2 Watt load, –40°C to 85°C
„
UL 94V-0 package material
„
Industry standard pinout
„
1kVDC isolation
„
5V, 12V, 15V & 24V input
„
5V, 9V, 12V, & 15V output
„
Pin compatible with NMR series
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, NMG05 types
Input voltage VIN, NMG12 types
Input voltage VIN, NMG15 types
Input voltage VIN, NMG24 types
35
25
25
25
60
35
25
25
25
40
60
40
40
40
70
50
50
50
MTTF2
28
20
18
16
35
22
16
13
12
25
40
25
25
25
40
30
25
30
Isolation
Capacitance
7.3
5.9
5.1
4.5
6
4.9
3.1
2.9
2.4
4
6
4.5
3.5
3.5
6
4
3.5
3.5
%
5.7
4.2
3.8
3.4
4.3
4.2
2.6
2.4
2.0
2.6
4.3
2.9
2.4
2.3
4.1
2.6
2.1
2
Efficiency (Typ.)
470
455
450
450
465
200
190
190
185
190
160
155
150
150
100
95
95
95
Efficiency (Min.)
mA
400
222
167
133
83
400
222
167
133
83
400
222
167
133
400
222
167
133
Ripple & Noise
(Max)1
mA
5
9
12
15
24
5
9
12
15
24
5
9
12
15
5
9
12
15
Ripple & Noise
(Typ)1
V
5
5
5
5
5
12
12
12
12
12
15
15
15
15
24
24
24
24
Load Regulation
(Max)
V
Load Regulation
(Typ)
Output
Voltage
Input Current at
Rated Load
Nominal Input
Voltage
Order Code
Output Current
SELECTION GUIDE
Units
V
260°C
550mW
7V
15V
18V
28V
OUTPUT CHARACTERISTICS
Parameter
Rated Power
Voltage Set Point Accuracy
Line regulation
Conditions
TA=-40°C to 85°C
See tolerance envelope
High VIN to low VIN
Min.
Typ.
1.05
1. See Ripple & Noise characterisation method.
2. Calculated using MIL-HDBK-217F FN2 with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NMG.E02 Page 1 of 7
NMG Series
www.murata-ps.com
Isolated 2W Single Output DC/DC Converters
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Flash tested for 1 second
Viso= 1000VDC
1000
10
Typ.
Max.
Units
VDC
GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
24V output types
All other types
Min.
Typ.
Max.
70
60
Units
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Storage
All output types
-40
-50
Case Temperature above
ambient
5V input types and 5V output types
All other types
Free air convection
Cooling
Typ.
Max.
Units
85
125
30
25
°C
EFFICIENCY VS LOAD
5V Input
12V Input
90
90
80
80
70
70
NMG0512SC
NMG0505SC
NMG0509SC
NMG0515SC
NMG0524SC
50
NMG1205SC
60
NMG1209SC
Efficiency (%)
Efficiency (%)
60
40
NMG1215SC
NMG1224SC
40
30
30
20
20
10
10
0
NMG1212SC
50
0
0
10
20
30
40
50
60
70
80
90
100
0
10
20
30
40
Load (%)
15V Input
60
70
80
90
100
24V Input
90
90
80
80
70
70
NMG1505SC
60
NMG1512SC
NMG1515SC
40
NMG2409SC
NMG2412SC
NMG1509SC
50
NMG2405SC
60
Efficiency (%)
Efficiency (%)
50
Load (%)
50
NMG2415SC
40
30
30
20
20
10
10
0
0
0
10
20
30
40
50
Load (%)
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
Load (%)
www.murata-ps.com/support
KDC_NMG.E02 Page 2 of 7
NMG Series
Isolated 2W Single Output DC/DC Converters
TEMPERATURE DERATING GRAPH
Output Power (W)
3
85°C
2
1
0
-40
Safe Operating Area
100
50
0
Ambient Temperature (°C)
150
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NMG series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 minute.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NMG series has been recognized by Underwriters Laboratory for functional insulation. Both input and output should normally be maintained within SELV limits i.e. less than
42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the
barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry
according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NMG series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The NMG series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature of 85ºC and/or case temperature
limit of 130ºC. Case temperature measured on the face opposite the pins. File number E151252 applies.
The NMG Series of converters are not internally fused so to meet the requirements of UL 60950 an input line fuse should always be used. An anti-surge 2A should be used for
NMG05xxSC models, and an anti-surge 0.75A should be used for NMG12xxSC models. All fuses should be UL approved and rated to at least the maximum allowable DC input
voltage.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of
260°C for 10 seconds. The pin termination finish is Tin Plate, Hot Dipped over Matte Tin with Nickel
Preplate. This series are backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NMG.E02 Page 3 of 7
NMG Series
Isolated 2W Single Output DC/DC Converters
APPLICATION NOTES
Minimum load
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in
an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product
series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.
NMG0505SC
NMG0509SC
NMG0512SC
NMG0515SC
NMG1205SC
NMG1209SC
NMG1212SC
NMG1215SC
Start-up time
μs
444
1120
1930
3470
409
1320
1320
2270
NMG0524SC
2200
NMG1224SC
1400
Start-up time
μs
100
170
300
450
80
130
220
330
NMG1505SC
NMG1509SC
NMG1512SC
NMG1515SC
NMG2405SC
NMG2409SC
NMG2412SC
NMG2415SC
Typical Start-Up Wave Form
Ripple & Noise Characterisation Method
All measurement to be taken with the following components connected to the UUT as detailed below. 50 Ohm coax cable, solder connections one end, BNC plug at
the other end.
C1
C2
1μF X7R multilayer ceramic capacitor rated at minimum 3 x the output voltage of the UUT
10μF tantalum capacitor rated at minimum 1.5 x the output voltage of the UUT with ESR of less than 100 milliohms at 100 kHz e.g. AVX TPS
series.
100nF multilayer ceramic capacitor, general purpose
450 Ohm resistor, carbon film, ±1%
50 Ohm BNC termination
3T of the coax cable through a ferrite toroid eg Ferroxcube TN32/19/13-3E25
Resistive load at the UUT maximum rating. Connections via twisted wires.
C3
R1
R2
T1
RLOAD
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
SUPPLY
Input
-
+
R1
T1
R2
Y INPUT
Output
-
R LOAD
www.murata-ps.com/support
KDC_NMG.E02 Page 4 of 7
NMG Series
Isolated 2W Single Output DC/DC Converters
APPLICATION NOTES (continued)
Output Ripple Reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended.
The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor
should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be
>20MHz.
L
Power
Source
NMG0505SC
NMG0509SC
NMG0512SC
NMG0515SC
NMG0524SC
NMG1205SC
NMG1209SC
NMG1212SC
NMG1215SC
NMG1224SC
NMG1505SC
NMG1509SC
NMG1512SC
NMG1515SC
NMG2405SC
NMG2409SC
NMG2412SC
L, μH
4.7
10
22
47
47
4.7
10
22
47
47
4.7
10
22
47
4.7
10
22
Inductor
SMD
82472C
82103C
82223C
82473C
82473C
82472C
82103C
82223C
82473C
82473C
82472C
82103C
82223C
82473C
82472C
82103C
82223C
DC
C
Load
DC
Through Hole
11R472C
11R103C
11R223C
11R473C
11R473C
11R472C
11R103C
11R223C
11R473C
11R473C
11R472C
11R103C
11R223C
11R473C
11R472C
11R103C
11R223C
Capacitor
C, μF
10
4.7
2.2
1
1
10
4.7
2.2
1
1
10
4.7
2.2
1
10
4.7
2.2
www.murata-ps.com/support
KDC_NMG.E02 Page 5 of 7
NMG Series
Isolated 2W Single Output DC/DC Converters
TOLERANCE ENVELOPES
The voltage tolerance envelopes show typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading and set point accuracy.
1224, 1515, 2412, 2415
2405
+6%
+2%
0%
Output Voltage
Output Voltage
+3%
+2%
0%
-3%
10
25
75
50
Output Load Current (%)
-3%
10
100
25
75
50
Output Load Current (%)
100
05XX,, 1205, 1209, 1212, 1215, 1505, 1509, 1512, 2409
Output Voltage
+5%
+2%
0%
-4%
10
25
50
75
100
Output Load Current (%)
www.murata-ps.com/support
KDC_NMG.E02 Page 6 of 7
NMG Series
Isolated 2W Single Output DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS - 4 PIN SIP
0.774 (19.65) (Max.)
0.301
(7.65)
(Max.)
0.4
(10.15)
(Max.)
Pin
Function
1
2
4
6
+VIN
-VIN
-VOUT
+VOUT
NMG0505SC
XYYWWi
0.0016
(0.40) Min.
TUBE OUTLINE DIMENSIONS
0.366 (9.30)
6
0.50 (0.020)
0.099 (2.52)
0.061 (1.54)
0.057 (1.45)
0.039 (1.00)
0.0118 (0.30)
0.0079 (0.20)
0.5 (12.70)
0.020 (0.50)
0.1 (2.54)
0.709 (18.00)
0.181 (4.60)
0.142 (3.60)
4
0.489 (12.43)
1 2
0.2 (5.00)
All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54)
pitch and within ±0.01 (0.25) of true position.
Weight: 2.8g
Unless otherwise stated all dimensions in inches (mm) ±0.5mm.
Tube length : 20.47 (520mm ±2mm).
Tube Quantity : 25
RECOMMENDED FOOTPRINT DETAILS
0.045 (1.15)
Ø 0.039 (1.00)
4 HOLES
0.00394 (0.1)
0.1 (2.54)
0.1 (2.54)
Unless otherwise stated all dimensions in inches (mm) ±0.5mm.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2014 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_NMG.E02 Page 7 of 7