Data Sheet

NMR Series
www.murata-ps.com
Isolated 1W Single Output DC/DC Converters
„
Efficiency up to 80%
mA
mA
Typ.
Max. Typ. Max.
%
pF
kHrs
5
12
15
5
12
15
5
12
15
200
83
67
200
83
67
200
83
67
290
260
253
121
110
110
60
53
52
12.5
6.90
6.50
12.5
6.90
6.50
6.80
2.80
2.50
13.4
7.70
7.50
13.4
7.70
7.50
10
4.0
3.50
69
77
79
69
76
76
70
78
80
28
33
40
36
58
56
61
98
122
1847
981
667
1485
869
613
1253
784
566
„
UL 94V-0 package material
NMR112C
NMR113C
NMR114C
15
15
15
5
12
15
200
83
67
INPUT CHARACTERISTICS
„
Industry standard pinout
Parameter
„
5V, 12V, 15V & 24V input
Voltage range
„
No heatsink required
„
Internal SMD construction
„
Fully encapsulated with toroidal magnetics
„
Custom solutions available
„
No electrolytic or tantalum capacitors
DESCRIPTION
The NMR series of industrial temperature range
DC/DC converters are the standard building blocks
for on-board distributed power systems. They are
ideally suited for providing single rail supplies on
primarily digital boards with the added benefit of
galvanic isolation to reduce switching noise. Surface mount technology and advanced packaging
materials produce rugged reliable performance
over an extended temperature range from -40ºC
to 85ºC.
10
10
10
10
10
10
15
15
15
Load
Regulation
Recommended
Obsolete
„
Footprint from 1.17cm2
„
5V, 12V & 15V output
6
4.6
4.3
5.3
5
4
8
7
8
MTTF1
V
5
5
5
12
12
12
24
24
24
„
Wide temperature performance at full
1 watt load, –40°C to 85°C
„
Power density up to 0.90W/cm3
Ripple & Noise3
V
Input
Current at
Rated Load
Isolation
Capacitance
„
1kVDC isolation
Efficiency
„
RoHS compliant
Output
Voltage
FEATURES
NMR100C
NMR101C
NMR102C
NMR106C
NMR107C
NMR108C
NMR118C
NMR119C
NMR120C
Nominal Input
Voltage
Order
Code
Output Current
SELECTION GUIDE
Reflected ripple current
93
85
84
8.1
3.3
2.8
Alternative
10
4
3.5
14
12
14
20
15
20
69
77
78
27
58
67
2110 MER1S1505SC
1790 MER1S1512SC
1560 MER1S1515SC
Conditions
Min.
Typ.
Max.
Continuous operation, 5V input types
Continuous operation, 12V input types
Continuous operation, 15V input types
Continuous operation, 24V input types
5V & 12V input types
15V & 24V input types
4.5
10.8
13.5
21.6
5
12
15
24
1.6
5
5.5
13.2
16.5
26.4
2
10
Units
Typ.
Max.
Units
1.0
W
1.0
1.2
%/%
Typ.
Max.
Units
V
mA p-p
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated Power2
Voltage Set Point Accuracy
Line regulation
TA=-40°C to 85°C
See tolerance envelope
High VIN to low VIN
Min.
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation voltage
Resistance
Flash tested for 1 second
Viso=1000VDC
1000
10
VDC
GΩ
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Internal power dissipation
Input voltage VIN, NMR100C, NMR101C, NMR102C
Input voltage VIN, NMR106C, NMR107C, NMR108C
Input voltage VIN, NMR112C, NMR113C, NMR114C
Input voltage VIN, NMR118C, NMR119C, NMR120C
300°C
550mW
7V
15V
18V
28V
1. Calculated using MIL-HDBK-217FN2 with nominal input voltage at full load.
2. See derating graph.
3. See ripple & noise characterisation method.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NMR.E01 Page 1 of 5
NMR Series
Isolated 1W Single Output DC/DC Converters
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
5V input types
12V input types
15V input types
24V input types
Min.
Typ.
Max.
Units
110
160
90
80
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Storage
All output types
-40
-50
Cooling
TOLERANCE ENVELOPES
NMR118
°C
33
28
NMR113, NMR 114, NMR119, NMR120
All other types
+4%
l Loa
d Lin
e
0%
-2.5%
-5%
75
50
25
Output Load Current (%)
100
+2%
VNOM
10
+5%
Typical
L
oad Line
75
50
25
Output Load Current (%)
+1%
-1%
-3%
100
Output Voltage
Typic
a
Output Voltage
Output Voltage
Units
+10%
+2%
VNOM
10
Max.
85
130
5V output types
All other output types
Free air convection
Case Temperature above ambient
+7%
+4.5%
Typ.
Typi
c
al Lo
ad L
ine
+2.5%
VNOM
-2.5%
-7.5%
10
75
50
25
Output Load Current (%)
100
The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading.
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NMR series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
For a part holding no specific agency approvals, such as the NMR series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or
60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part
could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must
be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to
safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NMR series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300ºC for 10 seconds. The pin termination finish
on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering
systems.
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_NMR.E01 Page 2 of 5
NMR Series
Isolated 1W Single Output DC/DC Converters
APPLICATION NOTES
Minimum load
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in
an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%.
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product
series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.
Typical Start-Up Wave Form
NMR100C
NMR101C
NMR102C
NMR106C
NMR107C
NMR108C
Start-up time
μs
2301
5570
8289
783
4770
4850
NMR112C
NMR113C
NMR114C
NMR118C
NMR119C
NMR120C
Start-up time
μs
744
1908
6620
671
5335
6370
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
C2
than 100mΩ at 100 kHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon film, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
SUPPLY
Input
-
+
R1
T1
R2
Y INPUT
Output
-
R LOAD
www.murata-ps.com/support
KDC_NMR.E01 Page 3 of 5
NMR Series
Isolated 1W Single Output DC/DC Converters
APPLICATION NOTES (continued)
Output Ripple Reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended.
The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor
should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be
>20MHz.
L
DC
Power
Source
NMR100C
NMR101C
NMR102C
NMR106C
NMR107C
NMR108C
NMR112C
NMR113C
NMR114C
NMR118C
NMR119C
NMR120C
L, μH
10
47
47
10
47
47
10
47
47
10
47
47
Inductor
SMD
82103C
82473C
82473C
82103C
82473C
82473C
82103C
82473C
82473C
82103C
82473C
82473C
C
Load
DC
Through Hole
11R103C
11R473C
11R473C
11R103C
11R473C
11R473C
11R103C
11R473C
11R473C
11R103C
11R473C
11R473C
Capacitor
C, μF
4.7
1
1
4.7
1
1
4.7
1
1
4.7
1
1
www.murata-ps.com/support
KDC_NMR.E01 Page 4 of 5
NMR Series
Isolated 1W Single Output DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS - 7 PIN SIP
7 Pin SIP Package
0.77
(19.50)
Pin
Function
1
2
4
6
+VIN
-VIN
-VOUT
+VOUT
0.236
(6.00)
TUBE OUTLINE DIMENSIONS
NMR100C
XYYWWi
0.181 (4.60)
0.141 (3.60)
4
6
2
0.1 (2.54)
1
0.022 (0.55)
0.0178 (0.45)
0.074±0.02
(1.88±0.50)
0.394
(10.00)
0.0118 (0.30)
0.0079 (0.20)
0.05
(1.25)
0.5 (12.70)
All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch and within
±0.01 (0.25) of true position.
Weight: 2.1g
All dimensions in inches ±0.01 (mm ±0.25mm)
Tube quantity: 25
RECOMMENDED FOOTPRINT DETAILS
 TEMPERATURE DERATING GRAPH
1.5
)0-&4
All dimensions in inches ±0.01 (mm ±0.25mm)
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
Output Power (W)
1.0
0.5
85°C
Safe Operating Area
120°C
0
-40
100
50
0
Ambient Temperature (°C)
150
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2013 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_NMR.E01 Page 5 of 5