NDTS Series www.murata-ps.com Isolated 3W Single Output DC/DC Converters SELECTION GUIDE FEATURES RoHS compliant Industry standard footprint Single isolated output Short circuit protection Operating temperature range –40°C to +85°C Low profile 24 pin case Order Code Input Voltage V (Nom.) NDTS0503C NDTS0505C NDTS0512C NDTS0515C NDTS1203C NDTS1205C NDTS1212C NDTS1215C NDTS2403C NDTS2405C NDTS2412C NDTS2415C NDTS4803C NDTS4805C NDTS4812C NDTS4815C 5 5 5 5 12 12 12 12 24 24 24 24 48 48 48 48 Parameter Voltage range 3.3V, 5V, 12V & 15V Output Footprint 4.73cm2 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 3.3 5 12 15 227 150 63 50 227 150 63 50 227 150 63 50 227 150 63 50 Input Efficiency Isolation MTTF2 Current (Min.) Capacitance mA % pF kHrs 909 600 250 200 909 600 250 200 909 600 250 200 909 600 250 200 898 806 769 757 350 320 310 310 172 156 149 147 87 83 76 75 63 71 76 77 71 73 75 76 71 78 80 84 71 75 80 80 28 30 32 33 29 32 35 32 32 32 35 35 32 32 40 40 1658 1665 1650 1633 1668 1665 1650 1633 1671 1673 1650 1617 1676 1668 1631 1600 INPUT CHARACTERISTICS 2:1 Wide input range 5V, 12V, 24V & 48V Input Output Current Rated Output Voltage Min. Load Full Load V mA mA Reflected ripple current1 UL94V-0 Package materials Conditions Min. Typ. Max. All NDTS05 types All NDTS12 types All NDTS24 types All NDTS48 types All NDTS05 types All NDTS12 types All NDTS24 types All NDTS48 types 4.5 9 18 36 5 12 24 48 50 30 40 30 9 18 36 72 150 100 50 40 Units Typ. Max. Units ±1 ±3 % 0.15 0.5 % 0503, 0505, 1203, 1205 0.8 1.0 2403, 2405, 4803, 4805 0.8 1.2 12V & 15V outputs 0.1 0.5 BW = 20Hz to 300kHz with external input/ output capacitors 15 40 mV rms BW = DC to 20MHz with external input/output capacitors 90 150 mV p-p V mA p-p No heatsink required Internal SMD construction Fully encapsulated OUTPUT CHARACTERISTICS Parameter Conditions Voltage set point accuracy With external input/output capacitors Low line to high line with external input/ output capacitors Line regulation DESCRIPTION The NDTS series is a range of low profile DC/DC converters offering a single regulated output over a 2:1 input voltage range. All parts deliver 3W output power up to 85°C without heatsinking. A flyback oscillator design with isolated feedback is used to give regulation over the full operating range of 25% to 100% of full load. It is strongly recommended that external capacitors be used on input and output to guarantee performance over full load and input voltage range (see recommended filter circuit for values). Load regulation Ripple Ripple & noise Minimum load to rated load with external input/ output capacitors Min. % 1. Please refer to relected ripple current measurement circuit on page 2. 2. Calculated using MIL-HDBK-217F with nominal input voltage at full load (ground benign) at 25°C. 3. Please refer to minimum load application note on page 4. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. For full details go to www.murata-ps.com/rohs www.murata-ps.com/support KDC_NDTS.D06 Page 1 of 6 NDTS Series Isolated 3W Single Output DC/DC Converters ABSOLUTE MAXIMUM RATINGS Short-circuit protection Lead temperature 1.5mm from case for 10 seconds Minimum output load for specification3 Input voltage 05 types Input voltage 12 types Input voltage 24 types Input voltage 48 types Free air space GENERAL CHARACTERISTICS Parameter Conditions Switching frequency 100% to 25% load, VIN Min. to Max. 8 Hours 300°C 25% of rated output 10V 20V 40V 80V 10mm Min. around component Min. Typ. 70 Max. Units 650 kHz Max. Units ISOLATION CHARACTERISTICS Parameter Conditions Min. Isolation voltage Resistance Flash tested for 1 second Resistance 1000 1 Conditions Min. Typ. VDC GΩ TEMPERATURE CHARACTERISTICS Parameter Operation Storage Case temperature rise above ambient in still air Typ. -40 -50 NDTS0515C, NDTS1205C, NDTS1212C, NDTS1215C, NDTS2405C, NDTS2412C, NDTS2415C, NDTS4812C & NDTS4815C NDTS0505C, NDTS0512C, NDTS1203C, NDTS2403C, NDTS4803C & NDTS4805C NDTS0503C Max. Units 85 125 30 ºC 40 50 TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NDTS series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals, such as the NDTS series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NDTS series has an EI ferrite core, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300ºC for 10 seconds. The pin termination finish on this product series is Tin. The series is backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs www.murata-ps.com/support KDC_NDTS.D06 Page 2 of 6 NDTS Series Isolated 3W Single Output DC/DC Converters APPLICATION NOTES Recommended Input & Output Capacitors Although these converters will work without external capacitors, they are necessary in order to guarantee the full parametric performance over the full line and load range. All parts have been tested and characterized using the following values and test circuit. Input Voltage 5V, 12V 24V, 48V CIN 100μF, 25V (0.25Ω at 100kHz) 10μF, 100V (1.5Ω at 100kHz) Output Voltage 3.3V, 5V 12V, 15V COUT 220μF, 16V (0.12Ω at 100kHz) 100μF, 25V (0.25Ω at 100kHz) Test circuit + VOUT + VIN Supply + VIN CIN NDTS Supply - VIN COUT - VIN - VOUT Reflected Ripple Current Measurement 12μH Current Probe + VIN Supply + VIN C1 Supply - VIN + VOUT NDTS CIN - VIN COUT Load - VOUT C1 = 220μF, ESR < 0.1Ω at 100kHz www.murata-ps.com/support KDC_NDTS.D06 Page 3 of 6 NDTS Series Isolated 3W Single Output DC/DC Converters APPLICATION NOTES (continued) Minimum Load The minimum load for correct operation is 25% of the full rated load across the specified input voltage range. Lower loads may cause a significant increase in output ripple and may cause the output voltage to exceed its specification transiently during power-down when the input voltage also falls below its rated minimum. The following graphs show the typical required minimum load required for stable operation in mA verses input voltage. Some variants are not included as they do not typically require a minimum load for stable operation: NDTD1212C, and NDTD1215C. The NDTS series will operate from a wider input range than specified in the input characteristics datasheet table with output power derating. Please contact Murata Power Solutions for further information. NDTS05XXC 200 180 Minimum Load (mA) 160 0503 140 120 0505 100 80 60 0512 40 20 0 4.5 0515 5.5 6.5 7.5 8.5 9.5 10.5 11.5 Input Voltage (V) NDTS12XXC 100 90 Minimum Load (mA) 80 70 1203 60 50 1205 40 30 20 10 0 9 11 13 15 17 19 21 Input Voltage (V) www.murata-ps.com/support KDC_NDTS.D06 Page 4 of 6 NDTS Series Isolated 3W Single Output DC/DC Converters APPLICATION NOTES (continued) NDTS24XXC 200 180 160 Minimum Load (mA) 140 120 2403 100 80 2405 60 40 2415 2412 20 0 10 15 20 25 30 35 40 45 Input Voltage (V) NDTS48XXC 120 100 Minimum Load (mA) 4803 80 60 4805 40 4812 4815 20 0 30 35 40 45 50 55 60 65 70 75 80 Input Voltage (V) www.murata-ps.com/support KDC_NDTS.D06 Page 5 of 6 NDTS Series Isolated 3W Single Output DC/DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS 1.270 (32.26) 0.200 (5.08) 7*/ 7*/ 7*/ 7*/ /" 7065 /$ 7065 NDTS2412C XYYWW 0.577 (14.66) 0.100 (2.54) 0.275 (7.00) 0.197 (5.00) 0.157 (4.00) Pin Function 2 3 9 11 14 16 22 23 -VIN -VIN NA NC +VOUT -VOUT +VIN +VIN NA - Not available for electrical connection. NC - No internal connection. RECOMMENDED FOOTPRINT DETAILS 0.029 (0.73) 0.025 (0.63) )0-&4 0.900 (22.86) 0.185 (4.70) 0.012 (0.30) 0.008 (0.20) 0.600 (15.25) Weight: 6.2g All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position. All dimensions in inches ±0.01 (mm ±0.25mm). All pins on a 0.1 (2.54) pitch and within ±0.01 (0.25) of true position. TUBE OUTLINE DIMENSIONS All dimensions in inches ±0.01 (mm) ±0.5mm. Tube length : 20.47±0.079 (520mm ±2mm). Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED Tube Quantity : 15 This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2012 Murata Power Solutions, Inc. www.murata-ps.com/support KDC_NDTS.D06 Page 6 of 6