MTU2 Series www.murata-ps.com Isolated 2W Single & Dual Output SM DC/DC Converters Footprint over pins 0.69cm2 Single & dual isolated output 1kVDC Isolation “Hi Pot Test” Parameter Voltage range Power density 3.403W/cm3 The devices are suitable for all applications where high volume production is envisaged. For full details go to www.murata-ps.com/rohs Efficiency (Min.) Input Current at Full Load pF kHrs 15 17 18 20 21 19 19 24 2650 2763 3060 2207 2314 2898 2697 2452 MTTF2 Ripple & Noise (Max.)3 % 79 82 85 80 80 82 85 83 Min. Typ. Max. Units 3.3 5.0 12.0 24 10 3.63 5.5 13.2 26.4 V Typ. Max. ISOLATION CHARACTERISTICS The MTU2 series is a new range of miniature surface mount, high performance 2W DC/DC converters. With a footprint reduction of over 50% from the previous generations of 2W SMD DC/DC, the MTU2 series offers 2W of available output power over a wide temperature range. The MTU2 series is more efficient and offers improved regulation performance for applications where a wide output voltage variation can not be tolerated. The MTU2 series is pin compatible with the MTU2 series. % 74 78 79 72 73 77 79 77 2.97 4.5 10.8 21.6 5V,12V & 24V single & dual outputs PRODUCT OVERVIEW mA 740 480 460 200 100 480 460 190 Continuous operation, 3.3V input types Continuous operation, 5V input types Continuous operation, 12V input types Continuous operation, 24V input types All variants Reflected ripple current Multi-layer ceramic capacitors mVp-p 53 75 47 65 14 30 40 60 30 50 30 55 15 35 15 35 Conditions 3.3V, 5V, 12V & 24V Input Custom solutions available 15 12 11 10 10 13 11 8 INPUT CHARACTERISTICS Efficiency up to 85% (Typ.) MSL Level 1 % 12.5 9.5 9 7.5 8 10.5 8.5 6.5 Ripple & Noise (Typ.)3 400 400 83 400 400 ±200 ±83 ±83 Load Regulation (Max) mA 5 5 24 5 5 ±5 ±12 ±12 Load Regulation (Typ.) V Isolation Capacitance UL 60950 Recognised V 3.3 5 5 12 24 5 5 12 Efficiency (Typ.) Patent Protected Output Voltage FEATURES MTU2S0305MC MTU2S0505MC MTU2S0524MC MTU2S1205MC MTU2S2405MC MTU2D0505MC MTU2D0512MC MTU2D1212MC Nominal Input Voltage Order Code1 Output Current SELECTION GUIDE Parameter Conditions Min. Isolation voltage Resistance Flash tested for 1 minute Viso= 1000VDC 1000 10 mA p-p Units VDC GΩ OUTPUT CHARACTERISTICS Parameter Conditions Rated power Voltage set point accuracy TA=-40°C to 85°C See tolerance envelope Line regulation High VIN to low VIN Min. MTU2S0305MC All other variants Typ. Max. Units 2.0 W 1.0 1.0 1.3 1.2 %/% Typ. Max. Units GENERAL CHARACTERISTICS Parameter Switching frequency Conditions Min. MTU2D0505MC 50 All other variants 70 kHz ABSOLUTE MAXIMUM RATINGS Input voltage VIN, MTU2S03 types Input voltage VIN, MTU2S05 types Input voltage VIN, MTU2S12 types Input voltage VIN, MTU2S24 types 5.5V 7V 15V 28V 1. If components are required in tape and reel format suffix order code with -R, e.g. MTU20505MC-R. 2. Calculated using MIL-HDBK-217 FN2 calculation model with nominal input voltage at full load. 3. See ripple & noise characterisation method. All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_MTU2.C02 Page 1 of 9 MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Specification Storage All output types -40 -50 Case temperature rise above ambient1 Cooling 0305, 1205, 2405 All other variants Free air convection Typ. Max. Units 30 25 85 125 45 35 °C 1 . Measured after 1 hour continuous operation at nominal VIN full load at the center of each PCB. TECHNICAL NOTES ISOLATION VOLTAGE ‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions MTU2 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” The MTU2 has been recognized by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The MTU2 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL The MTU2 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation to a maximum product PCB temperature of 120°C. Forced air cooling may be used to maintain this temperature requirement. File number E151252 applies. The MTU2 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below. MTU2S03xxxC: 1.5A MTU2S05xxxC: 0.63A MTU2S12xxxC: 0.3A MTU2S24xxxC: 0.25A All fuses should be UL approved and rated to at least the maximum allowable DC input voltage. www.murata-ps.com/support KDC_MTU2.C02 Page 2 of 9 MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak reflow solder temperature of 245ºC as per J-STD-020D.1. The pin termination finish on this product series is Matte Tin over Nickel Preplate. The series is backward compatible with Sn/Pb soldering systems. The series has a Moisture Sensitivity Level (MSL) 1. Samples of the product series were tested in accordance with the conditioning described for MSL level 1 in IPS/J-STD-020D.1. The product series passed electrical tests and visual inspection criteria. For further information, please visit: www.murata-ps.com/rohs TOLERANCE ENVELOPES The voltage tolerance envelopes show typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading and set point accuracy. 8.9% 2.5% 1.5% MTU2D0505MC, MTU2S0505MC & MTU2S1205MC Output Voltage Output Voltage MTU2D1212MC, MTU2S2405MC & MTU2D0512MC 10.2% 4% 1.8% -3.9% 10 25 50 75 -4.4% 100 10 25 Output Load Current (%) 13.7% Output Voltage 100 MTU2S0524MC 5.7% 2.2% Output Voltage MTU2S0305MC 50 75 Output Load Current (%) 9.4% 4% 0.4% -5.1% 10 25 50 75 Output Load Current (%) -7.6% 100 10 25 75 50 Output Load Current (%) 100 www.murata-ps.com/support KDC_MTU2.C02 Page 3 of 9 MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters APPLICATION NOTES Minimum load The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF. MTU2S0305MC MTU2S0505MC MTU2S0524MC MTU2S1205MC MTU2S2405MC MTU2D0505MC MTU2D0512MC MTU2D1212MC Typical Start-Up Wave Form Start-up time μs 225 165 3900 90 90 200 880 390 Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less C2 than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon film, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 + SUPPLY Input - + R1 T1 R2 Y INPUT Output - R LOAD www.murata-ps.com/support KDC_MTU2.C02 Page 4 of 9 MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters APPLICATION NOTES CONTINUED Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. MTU2S0305MC MTU2S0505MC MTU2S0524MC MTU2S1205MC MTU2S2405MC MTU2D0505MC MTU2D0512MC MTU2D1212MC Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be >20MHz. L, μH 4.7 4.7 47 4.7 4.7 4.7 47 47 Inductor SMD 82472C 82472C 82473C 82472C 82472C 82472C 82473C 82473C Through Hole 11R472C 11R472C 11R473C 11R472C 11R472C 11R472C 11R473C 11R473C Capacitor C, μF 22 22 4.7 22 10 22 4.7 4.7 L Power Source DC C Load DC www.murata-ps.com/support KDC_MTU2.C02 Page 5 of 9 MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters EFFICIENCY VS LOAD 3.3V INPUT 5V INPUT 90 90 80 80 70 70 60 Efficiency (%) Efficiency (%) 60 50 40 MTU2D0505MC 50 MTU2D0512MC MTU2S0505MC 40 MTU2S0524MC 30 30 20 20 10 10 0 0 10 20 30 40 50 0 0 10 20 30 40 50 60 70 80 90 60 70 80 90 100 Load (%) 100 Load (%) 12V INPUT 24V INPUT 90 90 80 80 70 70 60 50 MTU2S1205MC 40 MTU2D1212MC Efficiency (%) Efficiency (%) 60 50 40 30 30 20 20 10 10 0 0 10 20 30 40 50 60 Load (%) 70 80 90 100 0 0 10 20 30 40 50 60 70 80 90 100 Load (%) www.murata-ps.com/support KDC_MTU2.C02 Page 6 of 9 MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters TEMPERATURE DERATING MTU2S0305MC MTU2S0505MC 100 100 95 99 90 85 Load (%) Load (%) 98 80 75 97 70 96 65 60 95 55 45 45 50 55 60 65 70 75 80 50 55 85 60 65 70 75 80 85 Ambient Temperature OC Ambient Temperature OC MTU2S0524MC MTU2S1205MC 100 100 90 95 70 Load (%) Load (%) 80 90 60 50 85 40 80 30 45 50 55 60 65 70 75 80 85 45 50 55 Ambient Temperature OC 60 65 70 75 80 85 Ambient Temperature OC MTU2S2405MC MTU2D0505MC 100 100 95 90 98 85 80 96 Load (%) Load (%) 75 70 65 94 60 55 50 92 45 40 90 35 45 50 55 60 65 70 75 80 45 85 50 55 60 65 70 75 80 85 75 80 85 Ambient Temperature OC Ambient Temperature OC MTU2D0512MC MTU2D1212MC 80 90 60 80 Load (%) 100 Load (%) 100 40 70 20 60 0 50 45 50 55 60 65 70 Ambient Temperature OC 75 80 85 45 50 55 60 65 70 Ambient Temperature OC www.murata-ps.com/support KDC_MTU2.C02 Page 7 of 9 MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS PIN CONNECTIONS 2.54±0.10 [0.100±0.004] 6 4 5 Pin Single Output Types Function 1 3 4 5 6 1.56 [0.061] 3 1 Pin +VIN -VIN NC OV +VOUT Dual Output Types Function 1 3 4 5 6 5.08±0.10 [0.200±0.004] 8.20 [0.323] 8.40±0.45 [0.331±0.018] +VIN -VIN -VOUT OV +VOUT 8.50 MAX [0.335] S (0.35 [0.014]) SEATING PLANE 0.25 [0.010] 0.60 [0.024] x5 PINS 0.10 [0.004] 1.80±0.20 [0.071±0.008] 1.80±0.20 [0.071±0.008] S All dimensions in mm (inches) ±0.05mm (0.002”). Controlling dimension is mm. All pins on a 2.54mm (0.100”) pitch. Weight: 0.79g, typ. TUBE OUTLINE DIMENSIONS RECOMMENDED FOOTPRINT DETAILS 6.50 (0.256) 12.25 (0.482) MAX 2.54 (0.100) 2.54 (0.100) 0.75±0.15 (0.030±0.006) 12.25 (0.482) MAX 1.00 (0.039) 2.60 (0.102) Unless otherwise stated all dimensions in mm±0.25mm (inches). Tube length: 520mm ±2.00 Tube Quantity: 60 www.murata-ps.com/support KDC_MTU2.C02 Page 8 of 9 MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters TAPE & REEL SPECIFICATIONS REEL OUTLINE DIMENSIONS TAPE OUTLINE DIMENSIONS 330 (12.99) MAX 8.70±0.1 (0.343) 0.50±0.05 (0.020) DIRECTION OF UNREELING 100 Ø (3.94) MIN 2.00(+0.08) (AT HUB SECTION) 24.40 (0.96) -0.00 (0.00) +0.004 01.50 +0.10 -0.00 (00.059-0.000) 13.00±0.25 Ø (0.51±0.009) 30.40 (1.20) MAX 2.00±0.1 (0.079) 16.00±0.10 (0.630) 8.50±0.1 (0.335) 4.00±0.1 (0.157) 1.75±0.1 (0.069) 9.00±0.1 11.50±0.1 (0.453) 24.00±0.30 (0.945±0.012) REEL PACKAGING DETAILS XWWYY MTU2S 0505 XWWYY Product Orientation Pin 1, located nearest to carrier drive sprocket. MTU2S 0505 XWWYY MTU2S 0505 TRAILER SECTION 160 (6.30) MIN GOODS ENCLOSURE SECTION CARRIER TAPE START 100 (3.94) MIN LEADER SECTION 400 (15.75) MIN Reel Quantity: 400 pcs. Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2015 Murata Power Solutions, Inc. www.murata-ps.com/support KDC_MTU2.C02 Page 9 of 9