PWR1726AC - power, Murata

PWR1726AC
www.murata-ps.com
1.5 Watt Unregulated DC/DC Converter
DESCRIPTION
FEATURES
■
8000v Isolation Test Voltage
■
No External Parts Required
■
Remote On/Off
■
Low-Barrier Capacitance
■
RoHS Compliant
■
Synchronizable
The PWR1726AC is a single-channel, bipolar output DC/DC/
converter designed for those applications where high-isolation
voltage and low-barrier capacitance are critical for system reliability
and integrity.
Calculated mean-time-to-failure (MTTF) is in excess of 100
years at an ambient temperature of +25°C and at rated output
power. The performance of the PWR1726AC is not derated over its
entire specified temperature range of -25°C to +85°C.
Synchronization of the PWR1726AC may be accomplished
simply by connecting the Sync-In pin of one unit to the Sync-In pin
of another unit. Up to 8 converters may be synchronized in this
manner.
The PWR1726AC provides a plus and minus output voltage
that is approximately equal to the magnitude of the input voltage.
The unit operates over an input voltage range of 7VDC to 16VDC.
Each PWR1726AC isolation barrier is tested per the method
set forth by UL544, VDE750, and CSA C22.2.
APPLICATIONS
■
Biomedical Data Acquisition
■
Industrial Process Equipment
■
Data Acquisition
■
Test Equipment
■
Portable Equipment
ISO9001
For full details go to
www.murata-ps.com/rohs
CERTIFIED
www.murata-ps.com/support
TDC_PWR1726AC.F04 Page 1 of 3
PWR1726AC
1.5 Watt Unregulated DC/DC Converter
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, VIN = 15VDC, ILOAD = ±50mA and in free-running mode unless otherwise noted.
PARAMETER
CONDITIONS
INPUT
Rated Voltage
Voltage Range
Input Current
MIN
TYP
MAX
12
7
16
ILOAD = 0
ILOAD = Rated Load
Short Circuit
ILOAD = Rated Load
Ripple Current
ISOLATION
Voltage Rated Continuous
AC, 60Hz
DC
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Voltage
Voltage Range
30
145
115
15
3500
5000
8000
60sec, 60Hz
10
10
1
VISO = 240VAC, 60Hz
ILOAD = Rated Load
ILOAD Rated Load
ILOAD = OmA
Balanced Loads
Balanced Loads
Single Ended
7VDC < VIN < 18VDC
No Load < IOUT < ±50mA
BW = DC to 10MHz
ILOAD = 0
ILOAD = Rated Load
Rated Current
Current Range
Line Regulation
Load Regulation
Ripple Voltage
GENERAL
MTTF
165
2
±15
±14.25
±16.0
±15.75
±18.0
±16.5
±50
0
0
±90
180
1.16
0.3
Calculated per
MIL - HDBK - 217 Rev. E
Ground, Benign 25° C
Switching Frequency
TEMPERATURE
Specification
Operation
Storage
-25
-40
-55
UNITS
VDC
VDC
mA
mA
mA
mAp-p
Vrms
VDC
Vpk
G
pF
µA
VDC
VDC
VDC
mA
mA
mA
mV/mV
%/mA
15
50
mVp-p
mVp-p
(referenced to common)
1.2
120
MHr
kHz
+25
+85
+100
+110
°C
°C
°C
NOTE: Other input and output voltages may be available upon request. Please consult the factory.
MECHANICAL
TOP VIEW
SIDE VIEW
NOTES:
0.405±0.010"
(28.58±0.38)
PWR1726AC
0.032±.003"
0.130"
(.81±.05)
0.075"
(1.904)
1.300"
(32.99)
1
1.650±.015"
4 1 5 16
PIN CONNECTIONS
-Vout
-Vin
Sync-In
+Vin
REMOTE ON/OFF
COMMON
+Vout
0.900"
(22.84)
(41.91±0.38)
1
14
15
16
18
30
32
(3.30)
0.100"
(2.538)
0.1125"
(.32)
1.125±0.015"
(10.29)
32
0.075"
(1.904)
30
0.200"
(5.08)
18
1.200"
(30.46)
BOTTOM VIEW
MIN
All dimensions are in inches
(millimeters).
GRID: 0.100 inches (2.54 millimeters)
PIN PLACEMENT TOLERANCE:
±0.015"
To ensure proper operation,
the remote on/off pin should be
connected to +Vin when the unit
is on.
MATERIAL: Units are encapsulated
in a low thermal resistance molding
compound which has excellent
chemical resistance, wide operating
temperature range, and good electrical properties under high humidity
environments. The encapsulant
and outer shell of the unit have
UL94V-0 ratings.
Lead material
is brass; lead finish is matte Sn
(100 microinches minimum) over
Ni (40-80 microinches)
www.murata-ps.com/support
TDC_PWR1726AC.F04 Page 2 of 3
PWR1726AC
1.5 Watt Unregulated DC/DC Converter
ABSOLUTE MAXIMUM RATINGS
ORDERING INFORMATION
Input Voltage .........................................................................16VDC
Output Short-Circuit Duration ....................................................Continuous
Internal Power Dissipation ..................................................................... 2W
Lead Temperature (soldering, 10 seconds max) .............................+300°C
PWR
1726A
C
Device Family
PWR indicates DC/DC converter
Model Number
RoHS Compliant
TYPICAL PERFORMANCE CURVES
TA=+250C, Rated Input Voltage, Rated Output Current unless otherwise noted
OUTPUT VOLTAGE VS. OUTPUT CURRENT
Output Voltage (VDC)
Output Voltage (VDC)
OUTPUT VOLTAGE VS. INPUT VOLTAGE
Output Current (mA)
THROUGH-HOLE SOLDERING INFORMATION
These devices are intended for wave soldering or manual soldering.
They are not intended to be subject to surface mount processes under any
circumstances.
Input Voltage (VDC)
SYNCHRONIZATION INFORMATION
The unit may be synchronized to an external clock. Recommended frequency
is a minimum of 110kHz and a maximum of 250kHz. The sync signal must be
a square wave pulse with a peak of 7.5V min to 12V max, the amplitude being
referenced to -Vin.
The normal wave soldering process can be used with these devices where the
device is subjected to a maximum wave temperature of 260°C for a period of no
more than 10 seconds. Within this time and temperature range, the integrity of
the device’s plastic body will not be compromised and internal temperatures
within the converter will not exceed 175°C. Care should be taken to control
manual soldering limits identical to that of wave soldering.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2012 Murata Power Solutions, Inc.
www.murata-ps.com/support
TDC_PWR1726AC.F04 Page 3 of 3