HB04UC - power, Murata

LAST TIME BUY: AUGUST 31, 2014. CLICK HERE FOR DISCONTINUANCE NOTICE OF FEBRUARY 2014.
HB04UC
www.murata-ps.com
4.0W Unregulated High Isolation DC/DC Converter
PRODUCT OVERVIEW
The HB04UC Series is a low-cost, high-isolation voltage, unregulated, single
and dual output DC/DC converter. The dielectric withstand characteristics of
each converter is tested in production to ensure barrier integrity.
The HB04UC Series uses advanced circuit design and packaging technology
to realize superior reliability and performance. A 100kHz driven push-pull
oscillator is used to ensure stable frequency and non-saturating operation
of the input stage. This means there are no high peak voltages or currents
like other design topologies, which can reduce unit reliability. Reduced parts
count adds to the reliability of the HB04UC Series.
FEATURES

RoHS compliant

High Isolation - 3000v Rating

8000v Isolation Test Voltage
The high efficiency of the HB04UC Series means less internal power dissipation. With less heat to dissipate, the HB04UC Series can operate over a
wider ambient temperature range with no degradation of reliable operation.

Barrier 100% Production Tested

Low Barrier Capacitance - 10pf

Low Leakage Current - 2ma Max
The HB04UC Series offers the user low cost without sacrificing reliability.
The use of surface mounted devices and manufacturing technologies make
it possible to offer premium performance at low cost.

Internal Filtering
Applications

Biomedical Data Acquisition

Industrial Process Control

Analytical Measurements

Ground Loop Elimination

Intrinsic Safety Systems
MECHANICAL
0.400±0.010"
(10.16)
1.00±0.015"
(25.40±0.38)
0.015±0.005"
(0.38)
HBO4UC
0.040±.003"
(1.02±0.08)
0.170"
MIN
(4.32)
Notes: All dimensions are in inches (millimeters).
2.00±0.015"
(50.80±0.38)
GRID: 0.100 inches (2.54 millimeters)
+VIN
+VOUT
PIN PLACEMENT TOLERANCE: ± 0.015"
COMMON PIN: Not connected internally on single output models
MARKED WITH: date code, job code.
COMM
-VIN
-VOUT
MATERIAL: Units are encapsulated in a low thermal resistance molding compound which has excellent
chemical resistance, wide operating temperature range, and good electrical properties under high humidity
environments. The encapsulant and outer shell of the unit have UL94V-0 ratings. Lead material is brass; lead
finish is a 100-300 micro-inch layer of matte tin over a 40-80 micro-inch barrier layer of nickel.
BOTTOM VIEW
For full details go to
www.murata-ps.com/rohs
More product information and application notes are available
on our website at www.murata-ps.com
ISO9001
CERTIFIED
www.murata-ps.com/support
TDC_HB04UC.D01 Page 1 of 4
HB04UC
4.0W Unregulated High Isolation DC/DC Converter
ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise noted.
Model
**
**
**
**
**
**
*
**
*
HB04U05S05QC
HB04U05S12QC
HB04U05S15QC
HB04U12S05QC
HB04U12S12QC*
HB04U12S15QC
HB04U15S05QC
HB04U15S12QC
HB04U15S15QC
HB04U05D05QC
HB04U05D12QC
HB04U05D15QC
HB04U12D05QC
HB04U12D12QC
HB04U12D15QC
HB04U15D05QC
HB04U15D12QC
HB04U15D15QC
Input Current
Nominal Input
Voltage (VDC)
Rated Output
Voltage (VDC)
Rated Output
Current (mA)
No Load (mA)
Rated Load (mA)
5
5
5
12
12
12
15
15
15
5
5
5
12
12
12
15
15
15
5
12
15
5
12
15
5
12
15
±5
±12
±15
±5
±12
±15
±5
±12
±15
800
333
267
800
333
267
800
333
267
±400
±167
±134
±400
±167
±134
±400
±167
±134
60
60
60
25
25
25
20
20
20
60
60
60
25
25
25
20
20
20
1000
1000
1000
380
380
380
310
310
310
944
944
944
375
375
375
300
300
300
Efficiency(%)
80
80
80
87
87
87
87
87
87
85
85
85
88
88
88
88
88
88
Notes: Other input to output voltage options may be available. Please consult factory.
* ±6.25% Max for Voltage Setpoint Accuracy.
* LAST TIME BUY: AUGUST 31, 2014. CLICK HERE FOR DISCONTINUANCE NOTICE OF FEBRUARY 2014.
As of September 2014, ONLY the following part numbers will be available: HB04U12S12QC; HB04U12D15QC.
www.murata-ps.com/support
TDC_HB04UC.D01 Page 2 of 4
HB04UC
4.0W Unregulated High Isolation DC/DC Converter
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise noted.
PARAMETER
CONDITIONS
INPUT
Voltage Range
MIN
TYP
MAX
UNITS
4.5
10.8
13.5
5
12
15
351
5.5
13.2
16.5
VDC
Reflected Ripple Current
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Rated Power
Voltage Setpoint Accuracy
Temperature Coefficient
Ripple & Noise
BW = 10Hz to 2MHz
Line Regulation
Load Regulation
GENERAL
Switching Frequency
Package Weight
MTTF per MIL-HDBK-217, Rev. E
Ground Benign
60 Hz, 10 Seconds
mAp-p
3000
8000
10
10
1.2
VISO= 240VAC, 60Hz
4
±3
±0.02
100
20
±1.5
BW = DC to 10MHz
High Line to Low Line
See performance curves
2
±5
100
22
Circuit Stress Method
TA = +25°C
TEMPERATURE
Specification
Operation
Storage
W
%
%/°C
mVp-p
mVrms
%/% Vin
kHz
g
200,000
-25
-40
-40
VDC
Vpk
GΩ
pF
µArms
Hr
+70
+85
+110
°C
°C
°C
1. Reflected ripple current is measured at 50% load with a 33uF capacitor across the input of the UUT.
THROUGH-HOLE SOLDERING INFORMATION
These devices are intended for wave soldering or manual soldering.
They are not intended to be subject to surface mount processes under any circumstances.
The normal wave soldering process can be used with these devices where the device is subjected to a maximum wave temperature of 260°C for a period of
no more than 10 seconds. Within this time and temperature range, the integrity of the device’s plastic body will not be compromised and internal temperatures
within the converter will not exceed 175°C. Care should be taken to control manual soldering limits identical to that of wave soldering.
www.murata-ps.com/support
TDC_HB04UC.D01 Page 3 of 4
HB04UC
4.0W Unregulated High Isolation DC/DC Converter
ORDERING INFORMATION
ABSOLUTE MAXIMUM RATINGS
HB04U xxyzz Q
Internal Power Dissipation.....................................................................1W
Short Circuit Duration................................................................Momentary
Lead Temperature (soldering, 10 seconds max)..............................+300°C
C
Device Family
HB04U Indicates DC/DC Converter
Model Number
Where:
xx = Input Voltage
y = Number or Outputs (Single "S", Dual "D")
zz = Output Voltage
Package Option
RoHS Compliant
TYPICAL PERFORMANCE CURVES
VOUT VS LOAD
(±5Vout Models)
7.5
7.0
7.0
6.5
6.5
VOUT
VOUT
VOUT VS LOAD
(5Vout Models)
7.5
6.0
5.5
6.0
5.5
5.0
5.0
0
25
50
IOUT (%)
75
100
0
25
16
15
15
14
14
13
100
75
100
75
100
13
12
12
11
11
0
25
50
IOUT (%)
75
100
0
25
VOUT VS LOAD
(15Vout Models)
50
IOUT (%)
VOUT VS LOAD
(±15Vout Models)
22.5
22.5
21.0
21.0
19.5
19.5
VOUT
VOUT
75
VOUT VS LOAD
(±12Vout Models)
16
VOUT
VOUT
VOUT VS LOAD
(12Vout Models)
50
IOUT (%)
18.0
18.0
16.5
16.5
15.0
15.0
0
25
50
IOUT (%)
75
100
0
25
50
IOUT (%)
EFFICIENCY VS LOAD
Efficiency (%)
100
80
60
40
20
0
0
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
25
50
IOUT (%)
75
100
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2015 Murata Power Solutions, Inc.
www.murata-ps.com/support
TDC_HB04UC.D01 Page 4 of 4