MEU1 Series - power, Murata

MEU1 Series
www.murata-ps.com
Isolated 1W Single Output DC/DC Converters
„
Single isolated output
„
1kVDC isolation
„
Efficiency up to 87%
„
Wide temperature performance at full
1 watt load, –40°C to 85°C
„
Power density 2.62W/cm3
„
3.3V, 5V, and 12V input
„
3.3V, 5V, 9V, 12V and 15V output
„
Custom solutions available
V
V
mA
3.3
3.3
3.3
3.3
3.3
5
5
5
5
5
12
12
12
12
3.3
5
9
12
15
3.3
5
9
12
15
5
9
12
15
303
200
111
83
67
303
200
111
83
67
200
111
83
67
„
PCB mounting
INPUT CHARACTERISTICS
„
Footprint reduction of over 26% from
previous generations of 1W DC/DC’s
Parameter
Voltage range
DESCRIPTION
The MEU1 series is a new range of ultra miniature
through hole 1W DC/DC converters, available in
a ZIP style pinout. The MEU1 series offers 1W
of available output power over the industrial
temperature range of -40ºC to 85ºC. They are
ideally suited for providing local supplies on
control system boards.
With the added benefit of 1kVDC galvanic
isolation to reduce switching noise and allows
the device to be configured to provide an isolated
negative rail in systems where only positive rails
exist.
Reflected ripple current
mVp-p
50
45
40
40
40
50
45
40
40
35
45
40
40
40
mA
%
385
373
376
369
371
249
244
245
239
239
100
100
100
100
73
76
75
77
77
74
78
77
78
78
79
80
82
84
76
79
79
81
81
77
81
81
83
83
83
84
86
87
Conditions
Min.
Typ.
Max.
Continuous operation, 3.3V input types
Continuous operation, 5V input types
Continuous operation, 12V input types
3.3V & 5V Input types
12V Input types
2.97
4.5
10.8
3.3
5.0
12.0
3
5
3.63
5.5
13.2
15
15
MTTF1
Isolation Capacitance (Typ.)
Efficiency (Typ.)
Efficiency (Min.)
27
21
16
15
14
26
19
17
17
12
21
17
15
15
Input Current at Rated Load
14
12
13
12
10
12
9
12
10
8
7
9
7
6
%
11
9
10
9
8
9
7
9
8
6
5
6
5
4
Ripple & Noise (Max.)
Load Regulation (Typ.)
Ripple & Noise (Typ.)
„
UL60950 recognised
MEU1S0303ZC
MEU1S0305ZC
MEU1S0309ZC
MEU1S0312ZC
MEU1S0315ZC
MEU1S0503ZC
MEU1S0505ZC
MEU1S0509ZC
MEU1S0512ZC
MEU1S0515ZC
MEU1S1205ZC
MEU1S1209ZC
MEU1S1212ZC
MEU1S1215ZC
Load Regulation (Max.)
FEATURES
Output Current
Order Code
Output Voltage
Nominal Input Voltage
SELECTION GUIDE
pF
kHrs
28
30
34
40
33
29
34
47
45
39
43
71
91
91
3084
3125
3960
3343
3140
2762
3354
2952
3317
2600
3742
2732
2438
2980
Units
V
mA p-p
OUTPUT CHARACTERISTICS
Parameter
Conditions
Rated Power
Voltage Set Point Accuracy
TA=-40°C to 85°C
See tolerance envelope
Line regulation
High VIN to low VIN
Min.
Typ.
0303
All other types
1.0
1.0
Max.
Units
1.0
W
1.25
1.2
%/%
Max.
Units
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Flash tested for 1 second
Viso= 1000VDC
1000
10
Typ.
VDC
GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
Switching frequency
Min.
Typ.
Max.
85
Units
kHz
1. Calculated using MIL-HDBK-217F FN2 with nominal input voltage at full load.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_MEU1.C02 Page 1 of 8
MEU1 Series
Isolated 1W Single Output DC/DC Converters
ABSOLUTE MAXIMUM RATINGS
Lead temperature 1.5mm from case for 10 seconds
Input voltage VIN, MEU1S03 types
Input voltage VIN, MEU1S05 types
Input voltage VIN, MEU1S12 types
260°C
5.5V
7V
15V
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
Storage
All output types
-40
-50
Case Temperature above ambient
Cooling
Typ.
MEU1S03
All other types
Free air convection
Max.
Units
85
125
30
25
°C
TOLERANCE ENVELOPES
The voltage tolerance envelopes show typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to
changes in output loading and set point accuracy.
MEU1S0305ZC
+11%
+10%
+6%
+6%
0.5%
Output Voltage
Output Voltage
MEU1S0303ZC
+1%
-6%
10
25
75
50
Output Load Current (%)
-4.5%
100
10
25
MEU1S0309ZC
75
50
Output Load Current (%)
100
MEU1S0312ZC
+13%
Output Voltage
Output Voltage
+11%
+4%
10
25
75
50
Output Load Current (%)
100
+5%
0%
0.5%
-3.5%
-3%
10
25
75
50
Output Load Current (%)
100
www.murata-ps.com/support
KDC_MEU1.C02 Page 2 of 8
MEU1 Series
Isolated 1W Single Output DC/DC Converters
TOLERANCE ENVELOPES
MEU1S0315ZC
MEU1S0503ZC
+9%
+4%
+0.5%
Output Voltage
Output Voltage
+9%
+4%
0%
-2.5%
10
25
75
50
Output Load Current (%)
-6%
10
100
25
MEU1S0505ZC
75
50
Output Load Current (%)
100
MEU1S0509ZC
+8%
+5%
+1.5%
Output Voltage
Output Voltage
+13%
+5%
+1.5%
-2.5%
-3%
10
25
75
50
Output Load Current (%)
100
10
25
MEU1S0512ZC
75
50
Output Load Current (%)
100
MEU1S0515ZC
+9%
+8%
0%
-3%
10
25
50
75
100
Output Voltage
Output Voltage
+5%
+2.5%
+1.5%
-3%
10
25
50
75
100
www.murata-ps.com/support
KDC_MEU1.C02 Page 3 of 8
MEU1 Series
Isolated 1W Single Output DC/DC Converters
TOLERANCE ENVELOPES
MEU1S1205ZC
MEU1S1209ZC
+9%
+3%
+1%
Output Voltage
Output Voltage
+6%
+1%
+0.5%
-2.5%
10
25
75
50
Output Load Current (%)
-3%
100
10
25
MEU1S1212ZC
+6%
+1.5%
0%
-2.5%
25
75
50
Output Load Current (%)
100
Output Voltage
Output Voltage
100
MEU1S1215ZC
+5%
10
75
50
Output Load Current (%)
+1.5%
+1%
-2.5%
10
25
75
50
Output Load Current (%)
100
www.murata-ps.com/support
KDC_MEU1.C02 Page 4 of 8
MEU1 Series
Isolated 1W Single Output DC/DC Converters
EFFICIENCY VS LOAD
3.3V Input
5V Input
90
90
80
80
70
70
MEU1S0503ZC
MEU1S0303ZC
60
60
MEU1S0505ZC
Efficiency (%)
Efficiency (%)
MEU1S0305ZC
MEU1S0309ZC
50
MEU1S0312ZC
MEU1S0315ZC
40
MEU1S0509ZC
50
MEU1S0512ZC
MEU1S0515ZC
40
30
30
20
20
10
10
0
0
0
10
20
30
40
50
60
70
80
90
100
Load (%)
0
10
20
30
40
50
60
70
80
90
100
Load (%)
12V Input
90
80
70
Efficiency (%)
60
MEU1S1205ZC
MEU1S1209ZC
50
MEU1S1212ZC
MEU1S1215ZC
40
30
20
10
0
0
10
20
30
40
50
60
70
80
90
100
Load (%)
TEMPERATURE DERATING GRAPH
Output Power (W)
1.5
1.0
0.5
0
-40
85°C
Safe Operating Area
100
50
0
Ambient Temperature (°C)
150
www.murata-ps.com/support
KDC_MEU1.C02 Page 5 of 8
MEU1 Series
Isolated 1W Single Output DC/DC Converters
APPLICATION NOTES
Minimum Load
The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in
an increase in output voltage, which may rise to typically 1.25 times the specified output voltage if the output load falls to less than 5%.
Capacitive loading and start up
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product
series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF.
Start-up time
MEU1S0303ZC
MEU1S0305ZC
MEU1S0309ZC
MEU1S0312ZC
MEU1S0315ZC
MEU1S0503ZC
MEU1S0505ZC
MEU1S0509ZC
MEU1S0512ZC
MEU1S0515ZC
MEU1S1205ZC
MEU1S1209ZC
MEU1S1212ZC
MEU1S1215ZC
μs
140
280
1050
1930
2790
110
200
490
880
1400
140
240
400
600
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
than 100mΩ at 100 kHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon film, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
C2
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
SUPPLY
Input
-
+
R1
T1
R2
Y INPUT
Output
-
R LOAD
www.murata-ps.com/support
KDC_MEU1.C02 Page 6 of 8
MEU1 Series
Isolated 1W Single Output DC/DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation,
to verify the integrity of that isolation.
Murata Power Solutions MEU1 series of DC/DC converters are all 100% production tested
at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied
across the part in normal operation?”
The MEU1 has been recognized by Underwriters Laboratory for functional insulation, both
input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient
voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied
continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation
systems must form a barrier between these circuits and any user-accessible circuitry
according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can
actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The MEU1 series has toroidal isolation transformers,
with no additional insulation between primary and secondary windings of enameled
wire. While parts can be expected to withstand several times the stated test voltage,
the isolation capability does depend on the wire insulation. Any material, including this
enamel (typically polyurethane) is susceptible to eventual chemical degradation when
subject to very high applied voltages thus implying that the number of tests should be
strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified
test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The MEU1 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation, file number E151252 applies. The MEU1 Series of converters are not
internally fused so to meet the requirements of UL 60950
an anti-surge input line fuse should always be used with ratings as defined below.
MEU1S03xxxC: 0.50A
MEU1S05xxxC: 0.50A
MEU1S12xxxC: 0.25A
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260°C for 10 seconds. The pin
termination finish is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. This series are backward compatible with Sn/Pb
soldering systems.
For further information, please visit www.murata-ps.com/rohs
www.murata-ps.com/support
KDC_MEU1.C02 Page 7 of 8
MEU1 Series
Isolated 1W Single Output DC/DC Converters
PACKAGE SPECIFICATIONS
PIN CONNECTIONS - 4 PIN ZIF
8.30 [0.327] MAX
6.10 [0.240] MAX
Pin
Function
1
2
3
4
-VIN
+VIN
-VOUT
+VOUT
7.95 [0.313] MAX
RECOMMENDED FOOTPRINT DETAILS
0.40 [0.016] MIN
4.10±0.25 [0
0.40 [0.016]
x 4 HOLES
[
.161±0.010]
0.045
Ø 1.15
1.00 Ø 0.039
0.30 [0.012]
1.17±0.20 [0
]
1.27 [0.050]
.046±0.008]
2.54 [0.100]
1.27 [0.050]
2
3
2.54 [0.100]
1.61±0.10 [0
4
1
1.27 [0.050]
.063±0.004]
5.08 [0.200]
Weight: 0.77g
All dimensions in mm ±0.25mm (inches ±0.01). All pins on a 2.54 (0.1) pitch and within ± 0.25 (0.01) of true position.
TUBE OUTLINE DIMENSIONS
w
7.8 (0.307)
15.75 (0.62)
Tube Quantity : 60
Unless otherwise stated all dimensions in mm (inches) ±0.5mm.
Tube length (4 Pin) : 520mm ±2mm (20.47).
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2013 Murata Power Solutions, Inc.
www.murata-ps.com/support
KDC_MEU1.C02 Page 8 of 8