MGJ6 Series - power, Murata

MGJ6 Series
www.murata-ps.com
5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters
SELECTION GUIDE
Input
Voltage
Range
Rated Output Current
Output Power
Rated Output Voltage
Rated Output Current
Output Power
Typical
Application
V
See page 3
V
mA
W
V
mA
W
MGJ6T05150505MC
4.5 - 9
IGBT
+15
240
3.6
-10
240
2.4
MGJ6T12150505MC
9 - 18
IGBT
+15
240
3.6
-10
240
2.4
MGJ6T24150505MC
18 - 36
IGBT
+15
240
3.6
-10
240
2.4
MGJ6T05150505MC
4.5 - 9
SiC
+20
240
4.8
-5
240
1.2
MGJ6T12150505MC
9 - 18
SiC
+20
240
4.8
-5
240
1.2
MGJ6T24150505MC
18 - 36
SiC
+20
240
4.8
-5
240
1.2
MGJ6T05150505MC
4.5 - 9
MOSFET
+15
300
4.5
-5
300
1.5
MGJ6T12150505MC
9 - 18
MOSFET
+15
300
4.5
-5
300
1.5
MGJ6T24150505MC
18 - 36
MOSFET
+15
300
4.5
-5
300
1.5
Order Code1
FEATURES
SELECTION GUIDE (Continued)
„
Characterised partial discharge performance
„
Ultra low coupling capacitance 15pF
„
DC link voltage 3kVDC
Order Code1
„
5V, 12V & 24V input voltages
Typical
Application
V
See page 3
MGJ6T05150505MC
4.5 - 9
IGBT
5
10
120
200
5
10
118
150
MGJ6T12150505MC
9 - 18
IGBT
5
10
148
200
5
10
116
150
MGJ6T24150505MC
18 - 36
IGBT
5
10
148
200
5
10
110
150
MGJ6T05150505MC
4.5 - 9
SiC
5
10
169
275
5
10
59
75
MGJ6T12150505MC
9 - 18
SiC
5
10
206
275
5
10
58
75
MGJ6T24150505MC
18 - 36
SiC
5
10
203
275
5
10
55
75
MGJ6T05150505MC
4.5 - 9
MOSFET
5
10
120
200
5
10
59
75
MGJ6T12150505MC
9 - 18
MOSFET
5
10
148
200
5
10
58
75
MGJ6T24150505MC
18 - 36
MOSFET
5
10
148
200
5
10
55
75
PRODUCT OVERVIEW
For full details go to
www.murata-ps.com/rohs
Output 2
Input
Voltage
Range
„
105°C operating temperature
Offering configurable dual output voltages of +15V/10V, +20V/-5V and +15V/-5V, the MGJ6 series of
DC-DC converters is ideal for powering ‘high side’
and ‘low side’ gate drive circuits for IGBTs, Silicon
and Silicon Carbide Mosfets in bridge circuits.
A choice of asymmetric output voltages allows
optimum drive levels for best system efficiency
and EMI. The MGJ6 series is characterised for high
isolation and dv/dt requirements commonly seen in
bridge circuits used in motor drives and inverters.
A disable/frequency synchronisation pin simplifies
EMC filter design. The MGJ6 protection features
include short circuit protection and overload
protection.protection.
Load Regulation (Typ)3
„
5.2kVDC isolation test voltage ‘Hi Pot Test’
Load Regulation (Max)3
Output 1
Ripple & Noise (Max)2
„
Characterised dv/dt immunity 80kV/μs at
1.6kV
Ripple & Noise (Typ)2
„
ANSI/AAMI ES60601-1, 2 MOOPs recognition
pending
Load Regulation (Max)
„
Reinforced insulation to UL60950
„
recognition pending
3
„
Configurable dual outputs for all gate drive
applications: +15V/-5V, +15V/-10V & +20V/5V outputs
Load Regulation (Typ)3
„Optimised bipolar output voltages for IGBT/
SiC & Mosfet gate drives
Ripple & Noise (Max)2
„Patents Pending
Ripple & Noise (Typ)2
„No opto feedback
Output 2
Rated Output Voltage
Output 1
%
mVp-p
%
mVp-p
1. Components are supplied in tape and reel packaging, please refer to package specification section. Orderable part numbers are
MGJ6T05150505MC-R7 (23 pieces per reel), or MGJ6T05150505MC-R13 (92 pieces per reel).
2. See ripple & noise test method.
3. Between 75% and 100% rated output current.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
www.murata-ps.com/support
KDC_MGJ6C.C02 Page 1 of 10
MGJ6 Series
5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters
MGJ6T05150505MC
5
1500
72
78
15
552
6821
MGJ6T12150505MC
12
600
77
81
15
633
7061
MGJ6T24150505MC
24
300
79
83
15
666
6774
%
MIL 217
Telecordia
mA
Efficiency
(Typ)
V
Order Code
Efficiency
(Min)
Input Current
at Rated Load
MTTF1
Nominal Input
Voltage
Isolation Capacitance
SELECTION GUIDE (Continued)
pF
kHrs
INPUT CHARACTERISTICS
Parameter
Voltage range
Under voltage lock out
Input ripple current
Conditions
Min.
Typ.
Max.
5V input types
4.5
5
9
12V input types
9
12
18
24V input types
18
24
36
Turn on threshold MGJ6T05
4.1
Turn off threshold MGJ6T05
3.0
Turn on threshold MGJ6T12
8.1
Turn off threshold MGJ6T12
7.5
Turn on threshold MGJ6T24
16.7
Turn off threshold MGJ6T24
16.3
5V input types
40
12V input types
40
24V input types
24
Units
V
V
mA
p-p
OUTPUT CHARACTERISTICS
Parameter
Conditions
Minimum load
Voltage set point accuracy
Line regulation
Below 10% load, 5V and 15V outputs are clamped to 6V and 16V respectively
All output types
Low line to high line
Transient response
Min.
Typ.
Max.
Units
2
%
%
%
10
±4
Peak deviation (50-100% & 100-50% load swing)
0.4
%Vout
Settling time
0.1
ms
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Continuous barrier withstand voltage
Flash tested for 1 second
Viso = 1kVDC
Non-safety barrier application
5200
100
Typ.
Conditions
Min.
Max.
Units
3000
VDC
GΩ
V
Max.
Units
GENERAL CHARACTERISTICS
Parameter
Switching frequency
Typ.
100
kHz
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Operation
Storage
Product temperature rise above ambient
See derating graphs
-40
-50
Typ.
100% Load, Nom VIN, Still Air
Max.
Units
105
125
°C
25
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection
Input voltage, MGJ6 5V input types
Input voltage, MGJ6 12V input types
Input voltage, MGJ6 24V input types
Continuous
12V
20V
40V
1. Calculated using MIL-HDBK-217 FN2 and Telecordia SR-332 calculation model with nominal input voltage at full load.
www.murata-ps.com/support
KDC_MGJ6C.C02 Page 2 of 10
MGJ6 Series
5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters
APPLICATION NOTES
Start-up times
Typical start up times for this series, with no additional output capacitance are:
Start-up times
ms
15
15
15
Part No.
MGJ6T05150505MC
MGJ6T12150505MC
MGJ6T24150505MC
Output capacitance must not exceed:
Maximum output
capacitance
μF
220
470
Output Voltage
V
15
5
Disable/Frequency synchronisation
Please refer to application notes for further information.
Min
Disable/Synch
Synchronisation
Pull Down Current
Input High
Input Low
Frequency Range
Duty Cycle
2
0
90
25
Typ
0.5
100
Max
5
0.8
110
75
Units
mA
V
V
kHz
%
Output configurations for power switches
Terminal
IGBT
SIC
MOSFET
(P6)
15V Output
+15V
0.24A
+20V
0.24A
+15V
0.3A
(P5)
15V Return
5VA Output
0V
No connection
0V
(P4)
5VA Return
5VB Output
No connection
0V
-5V
0.3A
(P3)
5VB Return
-10V
0.24A
-5V
0.24A
No connection
www.murata-ps.com/support
KDC_MGJ6C.C02 Page 3 of 10
MGJ6 Series
5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters
APPLICATION NOTES (Continued)
Schematic for driving IGBT, SiC & MOSFET
MGJ DC-DC CONNECTIONS FOR DRIVING IGBT DEVICES
OPTOCOUPLER
PWM DRIVE
IGBT
16
+Vin
+15V
10
MGJ6Txx150505MC
IGBT
9
0V
3
DIS/SYNC
1
-Vin
7
NC
8
-10V
MGJ DC-DC CONNECTIONS FOR DRIVING SiC DEVICES
OPTOCOUPLER
PWM DRIVE
SiC
16
10
+20V
+Vin
MGJ6Txx150505MC
7
0V
3
9
NC
DIS/SYNC
SiC
1
-Vin
8
-5V
MGJ DC-DC CONNECTIONS FOR DRIVING MOSFET DEVICES
OPTOCOUPLER
PWM DRIVE
MOSFET
16
+Vin
+15V
10
MGJ6Txx150505MC
0V
3
DIS/SYNC
NC
9
8
MOSFET
1
-Vin
-5V
7
www.murata-ps.com/support
KDC_MGJ6C.C02 Page 4 of 10
MGJ6 Series
5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test
voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MGJ6 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 5.2kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
When the insulation in the MGJ6 series is not used as a safety barrier , i.e. provides functional isolation only, continuous or switched voltages across the barrier in excess
of 3kV are sustainable. Long term reliability testing at these voltages continues. Please contact Murata for further information.
The MGJ6 series is pending recognition by Underwiters Laboratory for various voltages, please see safety approval section below.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on
materials, construction and environment. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be
reduced by 20% from specified test voltage.
SAFETY APPROVAL
ANSI/AAMI ES60601-1
The MGJ6 series is pending recognition ANSI/AAMI ES60601-1 and provides 2 MOOP (means of operator protection) based upon a working voltage of 250 Vrms max., between
Primary and Secondary.
UL 60950
The MGJ6 series is pending recognition by Underwriters Laboratory (UL) to UL 60950 for reinforced insulation to a working voltage of 250Vrms.
Creepage and clearance 7mm.
CHARACTERISATION TEST METHODS
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
C2
than 100mΩ at 100 kHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon film, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
SUPPLY
Input
-
+
R1
T1
R2
Y INPUT
Output
-
R LOAD
RoHS COMPLIANCE, MSL AND PSL INFORMATION
This series is compatible with RoHS soldering systems with a peak reflow solder temperature of 245ºC as per
J-STD-020D.1. The pin termination finish on this product series is Gold with Nickel Pre-plate. The series is backward
compatible with Sn/Pb soldering systems. The series has a Moisture Sensitivity Level (MSL) 1.
www.murata-ps.com/support
KDC_MGJ6C.C02 Page 5 of 10
MGJ6 Series
5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters
EFFICIENCY VS LOAD
MGJ6T05150505MC
MGJ6T12150505MC
90
90
80
80
70
70
60
Efficiency (%)
Efficiency (%)
60
50
40
30
50
40
30
20
20
10
10
0
10
20
30
40
50
60
70
80
90
100
Load (%)
0
10
20
30
40
50
60
70
80
90
100
Load (%)
MGJ6T24150505MC
90
80
70
Efficiency (%)
60
50
40
30
20
10
0
10
20
30
40
50
60
70
80
90
100
Load (%)
www.murata-ps.com/support
KDC_MGJ6C.C02 Page 6 of 10
MGJ6 Series
5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters
DERATING GRAPHS
With no derating some components may be operating at the manufacturers maximum temperature ratings.
MGJ6T12150505MC
100
100
80
80
4.5Vin & 5Vin IPC-9592
Derating
60
9Vin IPC-9592 Derating
40
Load (%)
Load (%)
MGJ6T05150505MC
60
9Vin & 12Vin IPC-9592
Derating
40
18Vin IPC-9592
Derating
All Inputs No Derating
All Inputs No Derating
20
20
0
0
70
80
90
100
70
110
dĞŵƉĞƌĂƚƵƌĞ;ȗͿ
80
90
100
110
dĞŵƉĞƌĂƚƵƌĞ;ȗͿ
MGJ6T24150505MC
100
Load (%)
80
18Vin & 24Vin IPC-9592
Derating
60
36Vin IPC-9592
Derating
40
18Vin & 24Vin No
Derating
20
36Vin No Derating
0
70
80
90
100
110
dĞŵƉĞƌĂƚƵƌĞ;ȗͿ
www.murata-ps.com/support
KDC_MGJ6C.C02 Page 7 of 10
MGJ6 Series
5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters
EMC FILTERING AND SPECTRA
FILTERING
The following filter circuit and filter table shows the input filters typically required to meet EN55022 Quasi-PeakCurve A or B.
L1
C2
R1
C3
C4
DC
C1
DC
L2
C1, C2 & C3 Polyester or ceramic capacitor
C4
Electrolytic capacitor (note R1 could be omitted if C4 has ESR >= R1)
TO MEET CURVE B
Part Number
MGJ6T05150505MC
MGJ6T12150505MC
MGJ6T24150505MC
C1
3.3μF
3.3μF
3.3μF
L1
L2
47100SC
47100SC
47100SC
C2
10nF
10nF
10nF
C3
10nF
10nF
10nF
C4
470μF
470μF
470μF
MGJ6T12150505MC
100
100
90
90
80
80
70
70
60
60
dBuV
dBuV
MGJ6T05150505MC
R1
500mΩ
500mΩ
500mΩ
50
40
50
40
30
30
20
20
10
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
Frequency (Hz)
MGJ6T24150505MC
100
90
80
70
dBuV
60
50
40
30
20
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
www.murata-ps.com/support
KDC_MGJ6C.C02 Page 8 of 10
MGJ6 Series
5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
31.24±0.10 [1.230±0.004]
Pin
Function
1
-Vin
2
Dis/Sync
3
5VB RTN
22.61±0.10 [0.890±0.004]
SMA
PICKUP POINT
5VA RTN
4
5VB Out
15V RTN
5
5VA Out
SMA PICKUP POINT
(TOP OF FERRITE CORE)
13.99±0.45 [0.551±0.018]
14.19±0.45 [0.559±0.018]
6
15 Vout
7
+Vin
S
SEATING PLANE
5.08±0.33 [0.200±0.013]
x7 PINS
2.29±0.08 [0.090±0.003]
1.65±0.27 [0.065±0.011]
1
2
1.78±0.23 [0.070±0.009]
RECOMMENDED FOOTPRINT DETAILS
10.16 [0.400]
6.35±0.25 [0.250±0.010]
5.08 [0.200]
3
4
5
19.05 [0.750]
12.70±0.25 [0.500±0.010]
x7 PLACES
3.38 [0.133]
12.70 [0.500]
6
7
6.35 [0.250]
19.05±0.25 [0.750±0.010]
27.94±0.33 [1.100±0.013]
x7 PLACES
2.41 [0.095]
x7 PINS
1.60±0.05 [0.063±0.002]
5.08 [0.200]
27.94 [1.100]
All dimensions in mm (inches), Controlling dimensions is mm.
Tolerance (unless otherwise stated) ±0.25 (0.010).
RECOMMENDED
ISOLATION BARRIER
Weight: 12 g
www.murata-ps.com/support
KDC_MGJ6C.C02 Page 9 of 10
MGJ6 Series
5.2kVDC Isolated 6W Gate Drive SM DC/DC Converters
TAPE & REEL SPECIFICATIONS
REEL OUTLINE DIMENSIONS
REEL PACKAGING DETAILS
Ø330 [13.000] MAX
OR
Ø177.8 [7.000] MAX
[
13.50 0.531
Ø 12.80 Ø 0.504
]
50.40[1.984] MAX #
GOODS
ENCLOSURE
SECTION
LEADER SECTION
400 [15.748] MIN
1.50 [0.059]
MIN ##
TRAILER SECTION
160 [6.299] MIN
100 [3.937]
MIN
Ø20.20 [Ø0.795]
MIN
Product Orientation
Pin 1, located nearest to
carrier drive sprocket.
Tape & Reel specifications shall conform with current EIA-481 standard
Unless otherwise stated all dimensions in mm(inches)
Controlling dimension is mm
# Measured at hub
## Six equi-spaced slots on 180mm/7” reel
Reel Quantity: 7” - 23 or 13” - 92
TAPE OUTLINE DIMENSIONS
1.75 [0.069]
Ø2.0 [Ø0.079] MIN
2.0 [0.079]
4.0 [0.157]
[
]
+0.004
+0.1
Ø1.5 -0.0 Ø0.059 -0.000
20.2±0.15
[0.795±0.006]
44.0±0.3
[1.7323±0.012]
#31.8 [1.252]
40.4 [1.591]
COVER TAPE
0.2 ±0.05
23.2 [0.913] #
0.6 [0.024] MAX
15.65 [0.616]
Tape & Reel specifications shall conform with current EIA-481 standard
Unless otherwise stated all dimensions in mm(inches) ±0.1mm (±0.004 Inches)
Controlling dimension is mm
Components shall be orientated within the carrier tape as indicated
# Measured on a plane 0.3mm above the bottom pocket
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
36.0 [1.417]
DIRECTION OF UNREELING
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2015 Murata Power Solutions, Inc.
www.murata-ps.com/support