Thermoelectric Cooling Solutions Performance Parameters Mounted TEC Type ΔTmax Qmax K W TO812.1MC06018xx/6 Imax A Umax V Rt K/W H mm 1MC06-018-xx/6 (n=18) 1MC06-018-05/6 63 3.6 2.8 1.6 1MC06-018-08/6 67 2.5 1.9 1MC06-018-10/6 69 2.1 1.5 1MC06-018-12/6 69 1.8 1.3 2.3 1MC06-018-015/6 70 1.5 1.1 2.6 1.9 2.2 1.49 2.1 Performance data is specified at 300K, vacuum, incl. heatsink thermal resistance affect Dimensions Manufacturing options A. Header Material Kovar ! B. Header Surface Finish Au plaiting (base and pins) D. TEC Ceramics Material 1. Pure Al2O3(100%) 2. (used by default) 3. Aluminium Nitride (AlN) ! !! !! !! ! C. TEC to Header Mounting Solder 206 (Tmelt =206°C, Sn-Ag-In-Cu, flux-free process, RoHS compliant, Lead-Free) E. TEC Cold Side Finish 1. Blank ceramics (no metallization) 2. Metallized (Au plaiting) 3. Metallized and pre-tinned (with various solders available) ! F. Thermistor (optional) Can be mounted to cold side ceramics edge. ! G. Thermistor mounting Epoxy gluing H. Pinout configuration: Drawing shows the standard pinout configuration. It can be revised by request. 46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page #1 of 10 # Thermoelectric Cooling Solutions Performance Data 1MC06-018-05/6 @ 27ºC, Vacuum ΔTmax K Qmax W Imax A Umax V @50ºC, N2 ΔTmax K Qmax W Imax A Umax V 1MC06-018-05/6 63 3.55 2.8 2.2 1MC06-018-05/6 67 3.82 2.7 2.4 Note: Performance data is specified at optimal heatsink. TO-8 Header thermal resistance is included into estimations. Use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly. Performance Data 1MC06-018-08/6 @ 27ºC, Vacuum ΔTmax K Qmax W Imax A Umax V @50ºC, N2 ΔTmax K Qmax W Imax A Umax V 1MC06-018-08/6 67 2.49 1.9 2.2 1MC06-018-08/6 70 2.70 1.8 2.4 Note: Performance data is specified at optimal heatsink. TO-8 Header thermal resistance is included into estimations. Use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly. ! 46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page #2 of 10 # Thermoelectric Cooling Solutions Performance Data 1MC06-018-10/6 @ 27ºC, Vacuum ΔTmax K Qmax W Imax A Umax V @50ºC, N2 ΔTmax K Qmax W Imax A Umax V 1MC06-018-10/6 69 2.08 1.5 2.2 1MC06-018-10/6 71 2.25 1.5 2.4 Note: Performance data is specified at optimal heatsink. TO-8 Header thermal resistance is included into estimations. Use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly. Performance Data 1MC06-018-12/6 @ 27ºC, Vacuum ΔTmax K Qmax W Imax A Umax V @50ºC, N2 ΔTmax K Qmax W Imax A Umax V 1MC06-018-12/6 69 1.78 1.3 2.2 1MC06-018-12/6 72 1.93 1.3 2.4 Note: Performance data is specified at optimal heatsink. TO-8 Header thermal resistance is included into estimations. Use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly. ! 46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page #3 of 10 # Thermoelectric Cooling Solutions Performance Data 1MC06-018-15/6 @ 27ºC, Vacuum ΔTmax K Qmax W Imax A Umax V @50ºC, N2 ΔTmax K Qmax W Imax A Umax V 1MC06-018-15/6 70 1.46 1.1 2.2 1MC06-018-15/6 72 1.59 1.1 2.4 Note: Performance data is specified at optimal heatsink. TO-8 Header thermal resistance is included into estimations. Use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly. Application Tips 3. Connect TE cooler to DC power supply according to specified polarity. 4. Do not apply current/voltage higher than specified max values 1. Never heat up the sub-assembly more than 200˚C. 2. Never use the sub-assembly without an attached heat sink. Header is NOT a heatsink by itself. Mounting to TEC cold side 1. Soldering of the object to be cooled. Method suitable for a TE module with the metallized cold side (Ordering Options. Item E). Soldering method requires careful procedures: TEC A. Never overheat TEC (Application Tips. Item 1). ! Mounting to the cold side B. Use solder with melting point less than 200ºC. 2. Gluing of the object to be cooled. Method available by glues with good thermoconductive properties. Not recommended for high vacuum applications and long operations at high temperature. Header ! 46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page #4 of 10 # Thermoelectric Cooling Solutions Important notes 1. TEC Performance in this datasheet is specified in two standard ambient condition modes (vacuum, +27ºC and dry nitrogen (N2), +50ºC). The performance may differ under other conditions. Please, use TECCad software from RMT Ltd web site or contact RMT or its branch specialists directly for additional TEC performance info. 2. TEC ACR and Umax values are sensitive to ambient temperature. These values can be different from those specified in the datasheet at other ambient conditions. ACR and Umax raise with ambient temperature increasing. 3. TEC cooling capacity (Qmax) raises with ambient temperature. Please, use TECCad software for additional info or contact RMT specialists directly. 4. Thermoelectric coolers have the best performance in the temperature range from near room up to +80..90ºC. The performance is lower at temperatures below 0ºC. TEC is not suitable to work at cryogenic temperatures. 5. Driving a TEC at Imax or Umax doesn’t mean max performance mode. The real optimal mode may depend on operating conditions and heatload. In fact a better performance can be reached at operating current and voltage lower than Imax and Umax values specified in the datasheet. 6. It is strongly recommended to avoid a direct mounting of thermoelectric cooler to pure Copper, Aluminium or Nickel materials as well as a mounting of objects from these materials on TEC cold side. Any material with high CTE may affect TEC lifetime and/or damage it in case of improper mounting, thermal shock or temperature cycling. In case of above mentioned materials necessity, it is recommended to use soft solders or glues with large modulus of elasticity (Indium-based solders or silicon-based thermoconductive glues). 7. RMT Ltd confirms that all thermoelectric coolers meet the requirements of Telcordia GR-468 standard. The up-todate Reliability Report is available by request. RMT Ltd warranties thermoelectric coolers lifetime no less than 250K-300K operating hours under normal application conditions. ! 46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page #5 of 10 # Thermoelectric Cooling Solutions Sub-assembly Overview Thermoelectric Cooler 1MC06-018-xx/6 NTC Thermistor 2.2kOhm or 10kOhm Thermistor (optional) TO-8 20pin Header (Material Kovar) TE Cooler Lead Free Internal Assembly Solder (Lead-Free Solder 230, Sn-Sb) Flexible pinout configuration for TEC and thermistor TEC to Header High-Temperature Mounting by Soldering (Lead-Free Solder 206, Sn-Ag-In-Cu, vacuum flux-free process) Laser Labeling (optional) is available for Header TO-8 20pin Header Drawing ! 46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page #6 of 10 # Thermoelectric Cooling Solutions Thermoelectric Cooler Overview Cold side Ceramics (top side) Al2O3 Ceramics by default (AlN solution is available by request) TE Cooler Lead Free Internal Assembly (Lead-Free Solder 230, Sn-Sb) - Pellets (BiTe posts) TEC Polarity (can be modified by request) + Hot Side Ceramics (bottom side) Terminal Wires Application Tips 1. Never heat TE module more than 200˚C (TEC assembled at 230˚C). 2. Never use TE module without an attached heat sink at hot (bottom) side. 3. Connect TE module to DC power supply according to polarity. 4. Do not apply DC current higher than Imax. Installation 1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types require other assembling methods in most cases. 1. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option and also makes pre-tinning for TE modules. 2. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good thermoconductive properties. A glue is usually based on some epoxy compound filled with some thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a specific type depends on application features and the type of a TE module. Object being cooled Object being cooled TEC TEC 1 3 2 Screw mounting Heatsink ! Soldering Heatsink Gluing 46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page #7 of 10 # Thermoelectric Cooling Solutions Additional Options TEC Polarity TEC Polarity can be modified by request. The specified polarity in this datasheet is typical. It can be reversed in accordance to Customer application requirements. - + + Standard polarity - Reversed polarity Terminal Wires Options The wires are of tinned Copper, blank (not isolated) by default. Various options for isolated wires are available by request. The available solutions include isolated wires, isolated color-coded wires, flexible multicore wires and more. S t a n d a rd w i re s , tinned Copper Isolated wires Customized Au Patterns Customized Au patterns on thermoelectric cooler cold side are available by request. Selective Pretinning over pattern is also available. Please, contact RMT Ltd for additional information about customized Au patterns requirements. Customized Au pattern on cold side Selective pre-tinning over pattern TEC Height modification Standard TEC height can be modified without performance changes by using ceramics of different thickness. Standard thermoelectric cooler height (specified in the datasheet) may be modified in a range -0.5..+1.0mm for single-stage TEC by request. Standard height M o d i fi e d h e i g h t , another ceramics thickness ! 46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page #8 of 10 # Thermoelectric Cooling Solutions Contacts ! Russia - RMT Ltd. Headquarters Warshavskoe sh. 46, 115230, Moscow Russia Tel: +7-499-678-2082 Fax: +7-499-678-2083 Web: www.rmtltd.ru Email: [email protected] Europe/USA - TEC Microsystems GmbH Korea - Sunflower Energy Schwarzschildstrasse 8, 12489 Berlin, 1F, 665-6, Pungdeokcheon-dong Germany Suji-gu, Yongin-si, Gyeonggi-do Tel: +49 30 6789 3314 South Korea Fax: +49 30 6789 3315 Tel: +82 312767992 Web: www.tec-microsystems.com Fax: +82 312767993 Email: [email protected] web: http://www.sunfl.co.kr China - ProTEC Ltd. Taiwan - Wellspring & Vim Tech Corp 深圳市南⼭山区登良路恒裕中⼼心B座207 9F-1, No.657 Pei-an Rd. 电话:+86-755-61596066 Taipei 104 传真:+86-755-61596036 Taiwan 邮编:518054 Tel: +886 2-85091756 Web: www.protecltd.com Fax: +886 2-85091846 Email: [email protected] web: www.wellvim.com.tw ! ! ! ! ! ! Email: [email protected] ! 46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page #9 of 10 # Thermoelectric Cooling Solutions ! Legal Notice ! All logos, images, trademarks and product names (collectively Materials) are proprietary to RMT Ltd and/ or any of its affiliates, or subsidiaries, or other respective owners that have granted RMT Ltd the permission and/or license to use such Materials. All images are provided by RMT Ltd. and are subjects of copyright protection. RMT Ltd, TEC Microsystems GmbH and ProTEC Ltd. do not grant a copyright license (express or implied) to the Recipient, except that Recipient may reproduce the logos, images and text materials in this press-release without any alteration for non-promotional or editorial purposes only with a written note about materials owner. ! Copyright protection warning ! Graphic materials and text from this datasheet may not be used commercially without a prior response in writing on company letterhead and signed by RMT Ltd authority. Thank you for respecting the intellectual property rights protected by the International Copyright laws. All Images contain RMT hidden watermark for the immediate proof of their origin. RMT Ltd. RMT Image Hidden Watermark ! 46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice. Page 10 # of 10 #