1MC06-018-xx

Thermoelectric Cooling Solutions
Performance Parameters
Mounted TEC
Type
ΔTmax Qmax
K
W
TO812.1MC06018xx/6
Imax
A
Umax
V
Rt
K/W
H
mm
1MC06-018-xx/6 (n=18)
1MC06-018-05/6
63
3.6
2.8
1.6
1MC06-018-08/6
67
2.5
1.9
1MC06-018-10/6
69
2.1
1.5
1MC06-018-12/6
69
1.8
1.3
2.3
1MC06-018-015/6
70
1.5
1.1
2.6
1.9
2.2
1.49
2.1
Performance data is specified at 300K, vacuum, incl. heatsink thermal resistance affect
Dimensions
Manufacturing options
A. Header Material
Kovar
!
B. Header Surface Finish
Au plaiting (base and pins)
D. TEC Ceramics Material
1. Pure Al2O3(100%)
2. (used by default)
3. Aluminium Nitride (AlN)
!
!!
!!
!!
!
C. TEC to Header Mounting
Solder 206 (Tmelt =206°C,
Sn-Ag-In-Cu, flux-free process,
RoHS compliant, Lead-Free)
E. TEC Cold Side Finish
1. Blank ceramics
(no metallization)
2. Metallized (Au plaiting)
3. Metallized and pre-tinned
(with various solders
available)
!
F. Thermistor (optional)
Can be mounted to cold side
ceramics edge.
!
G. Thermistor mounting
Epoxy gluing
H. Pinout configuration:
Drawing shows the standard
pinout configuration. It can be
revised by request.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page #1 of 10
#
Thermoelectric Cooling Solutions
Performance Data
1MC06-018-05/6
@ 27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
1MC06-018-05/6
63
3.55
2.8
2.2
1MC06-018-05/6
67
3.82
2.7
2.4
Note: Performance data is specified at optimal heatsink. TO-8 Header thermal resistance is included into estimations. Use TECCad
Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
Performance Data
1MC06-018-08/6
@ 27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
1MC06-018-08/6
67
2.49
1.9
2.2
1MC06-018-08/6
70
2.70
1.8
2.4
Note: Performance data is specified at optimal heatsink. TO-8 Header thermal resistance is included into estimations. Use TECCad
Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page #2 of 10
#
Thermoelectric Cooling Solutions
Performance Data
1MC06-018-10/6
@ 27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
1MC06-018-10/6
69
2.08
1.5
2.2
1MC06-018-10/6
71
2.25
1.5
2.4
Note: Performance data is specified at optimal heatsink. TO-8 Header thermal resistance is included into estimations. Use TECCad
Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
Performance Data
1MC06-018-12/6
@ 27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
1MC06-018-12/6
69
1.78
1.3
2.2
1MC06-018-12/6
72
1.93
1.3
2.4
Note: Performance data is specified at optimal heatsink. TO-8 Header thermal resistance is included into estimations. Use TECCad
Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page #3 of 10
#
Thermoelectric Cooling Solutions
Performance Data
1MC06-018-15/6
@ 27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
1MC06-018-15/6
70
1.46
1.1
2.2
1MC06-018-15/6
72
1.59
1.1
2.4
Note: Performance data is specified at optimal heatsink. TO-8 Header thermal resistance is included into estimations. Use TECCad
Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
Application Tips
3. Connect TE cooler to DC power supply according
to specified polarity.
4. Do not apply current/voltage higher than specified
max values
1. Never heat up the sub-assembly more than 200˚C.
2. Never use the sub-assembly without an attached
heat sink. Header is NOT a heatsink by itself.
Mounting to TEC cold side
1. Soldering of the object to be cooled.
Method suitable for a TE module with the metallized cold side
(Ordering Options. Item E). Soldering method requires careful
procedures:
TEC
A. Never overheat TEC (Application Tips. Item 1).
!
Mounting to the
cold side
B. Use solder with melting point less than 200ºC.
2. Gluing of the object to be cooled.
Method available by glues with good thermoconductive properties. Not recommended for high vacuum applications and long operations at high temperature.
Header
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page #4 of 10
#
Thermoelectric Cooling Solutions
Important notes
1. TEC Performance in this datasheet is specified in two standard ambient condition modes (vacuum, +27ºC and dry
nitrogen (N2), +50ºC). The performance may differ under other conditions. Please, use TECCad software from
RMT Ltd web site or contact RMT or its branch specialists directly for additional TEC performance info.
2. TEC ACR and Umax values are sensitive to ambient temperature. These values can be different from those
specified in the datasheet at other ambient conditions. ACR and Umax raise with ambient temperature increasing.
3. TEC cooling capacity (Qmax) raises with ambient temperature. Please, use TECCad software for additional info or
contact RMT specialists directly.
4. Thermoelectric coolers have the best performance in the temperature range from near room up to +80..90ºC. The
performance is lower at temperatures below 0ºC. TEC is not suitable to work at cryogenic temperatures.
5. Driving a TEC at Imax or Umax doesn’t mean max performance mode. The real optimal mode may depend on
operating conditions and heatload. In fact a better performance can be reached at operating current and voltage
lower than Imax and Umax values specified in the datasheet.
6. It is strongly recommended to avoid a direct mounting of thermoelectric cooler to pure Copper, Aluminium or
Nickel materials as well as a mounting of objects from these materials on TEC cold side. Any material with high
CTE may affect TEC lifetime and/or damage it in case of improper mounting, thermal shock or temperature
cycling. In case of above mentioned materials necessity, it is recommended to use soft solders or glues with large
modulus of elasticity (Indium-based solders or silicon-based thermoconductive glues).
7. RMT Ltd confirms that all thermoelectric coolers meet the requirements of Telcordia GR-468 standard. The up-todate Reliability Report is available by request. RMT Ltd warranties thermoelectric coolers lifetime no less than
250K-300K operating hours under normal application conditions.
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page #5 of 10
#
Thermoelectric Cooling Solutions
Sub-assembly Overview
Thermoelectric Cooler
1MC06-018-xx/6
NTC Thermistor
2.2kOhm or
10kOhm
Thermistor (optional)
TO-8 20pin Header
(Material Kovar)
TE Cooler Lead Free
Internal Assembly Solder
(Lead-Free
Solder 230, Sn-Sb)
Flexible pinout configuration
for TEC and thermistor
TEC to Header High-Temperature
Mounting by Soldering
(Lead-Free Solder 206,
Sn-Ag-In-Cu,
vacuum flux-free process)
Laser Labeling (optional)
is available for Header
TO-8 20pin Header Drawing
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page #6 of 10
#
Thermoelectric Cooling Solutions
Thermoelectric Cooler Overview
Cold side Ceramics
(top side)
Al2O3 Ceramics by default
(AlN solution is available by
request)
TE Cooler Lead Free
Internal Assembly
(Lead-Free Solder 230,
Sn-Sb)
-
Pellets (BiTe posts)
TEC Polarity
(can be modified by
request)
+
Hot Side Ceramics
(bottom side)
Terminal Wires
Application Tips
1. Never heat TE module more than 200˚C (TEC
assembled at 230˚C).
2. Never use TE module without an attached heat sink
at hot (bottom) side.
3. Connect TE module to DC power supply according
to polarity.
4. Do not apply DC current higher than Imax.
Installation
1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in
another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types
require other assembling methods in most cases.
1. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option
and also makes pre-tinning for TE modules.
2. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good
thermoconductive properties. A glue is usually based on some epoxy compound filled with some
thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a
specific type depends on application features and the type of a TE module.
Object being cooled
Object being cooled
TEC
TEC
1
3
2
Screw mounting
Heatsink
!
Soldering
Heatsink
Gluing
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page #7 of 10
#
Thermoelectric Cooling Solutions
Additional Options
TEC Polarity
TEC Polarity can be modified by request. The
specified polarity in this datasheet is typical.
It can be reversed in accordance to Customer
application requirements.
-
+
+
Standard polarity
-
Reversed polarity
Terminal Wires Options
The wires are of tinned Copper, blank (not isolated)
by default. Various options for isolated wires are
available by request. The available solutions
include isolated wires, isolated color-coded wires,
flexible multicore wires and more.
S t a n d a rd w i re s ,
tinned Copper
Isolated wires
Customized Au Patterns
Customized Au patterns on thermoelectric cooler
cold side are available by request. Selective Pretinning over pattern is also available. Please,
contact RMT Ltd for additional information about
customized Au patterns requirements.
Customized Au pattern
on cold side
Selective pre-tinning
over pattern
TEC Height modification
Standard TEC height can be modified without
performance changes by using ceramics of
different thickness. Standard thermoelectric cooler
height (specified in the datasheet) may be modified
in a range -0.5..+1.0mm for single-stage TEC by
request.
Standard height
M o d i fi e d h e i g h t ,
another ceramics
thickness
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page #8 of 10
#
Thermoelectric Cooling Solutions
Contacts
!
Russia - RMT Ltd. Headquarters
Warshavskoe sh. 46, 115230, Moscow
Russia
Tel: +7-499-678-2082
Fax: +7-499-678-2083
Web: www.rmtltd.ru
Email: [email protected]
Europe/USA - TEC Microsystems GmbH
Korea - Sunflower Energy
Schwarzschildstrasse 8, 12489 Berlin,
1F, 665-6, Pungdeokcheon-dong
Germany
Suji-gu, Yongin-si, Gyeonggi-do
Tel: +49 30 6789 3314
South Korea
Fax: +49 30 6789 3315
Tel: +82 312767992
Web: www.tec-microsystems.com
Fax: +82 312767993
Email: [email protected]
web: http://www.sunfl.co.kr
China - ProTEC Ltd.
Taiwan - Wellspring & Vim Tech Corp
深圳市南⼭山区登良路恒裕中⼼心B座207
9F-1, No.657 Pei-an Rd.
电话:+86-755-61596066
Taipei 104
传真:+86-755-61596036
Taiwan
邮编:518054
Tel: +886 2-85091756
Web: www.protecltd.com
Fax: +886 2-85091846
Email: [email protected]
web: www.wellvim.com.tw
!
!
!
!
!
!
Email: [email protected]
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page #9 of 10
#
Thermoelectric Cooling Solutions
!
Legal Notice
!
All logos, images, trademarks and product names (collectively Materials) are proprietary to RMT Ltd and/ or any
of its affiliates, or subsidiaries, or other respective owners that have granted RMT Ltd the permission and/or
license to use such Materials. All images are provided by RMT Ltd. and are subjects of copyright protection.
RMT Ltd, TEC Microsystems GmbH and ProTEC Ltd. do not grant a copyright license (express or implied) to
the Recipient, except that Recipient may reproduce the logos, images and text materials in this press-release
without any alteration for non-promotional or editorial purposes only with a written note about materials owner.
!
Copyright protection warning
!
Graphic materials and text from this datasheet may not be used commercially without a prior response in
writing on company letterhead and signed by RMT Ltd authority.
Thank you for respecting the intellectual property rights protected by the International Copyright laws.
All Images contain RMT hidden watermark for the immediate proof of their origin.
RMT Ltd.
RMT Image
Hidden Watermark
!
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2014. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 10
# of 10
#