Manufacturing options Dimensions

Thermoelectric Cooling Solutions
Performance Parameters
Mounted
TE Cooler Type
ΔTmax
K
Qmax
W
PS28.2MC04059xxAN
Imax
A
Umax
V
Rt
K/W
H
mm
PS28.2MC04059xxAN
2MC04-059-03AN
97
2.6
2.0
5.9
1.6
2MC04-059-05AN
101
1.7
1.3
6.0
2.0
2MC04-059-08AN
103
1.1
0.8
6.0
2MC04-059-10AN
103
0.9
0.7
5.9
2MC04-059-12AN
104
0.7
0.6
6.0
3.4
2MC04-059-15AN
104
0.6
0.4
6.0
4.0
0.17
2.6
3.0
Performance values are specified at 300K ambient temperature, Vacuum. Package Thermal Resistance (Rt) affect is included into estimations.
±0.20
25.40
Dimensions
Manufacturing options
A. Package Material
Kovar
B. Package Surface Finish
Au plating (Base and Pins)
C. TEC Assembly Solder
Solder Sn-Sb (Tmelt=230°C)
D. TEC to Package mounting
Solder 206 (Tmelt =206°C,
Sn-Ag-In-Bi, flux-free process)
E. TEC Cold Side Surface
1. Blank ceramics - default
2. Metallized (Au plating)
3. Metallized and pre-tinned with:
3.1. In-Sn, Tmelt =117°C
3.2. Sn-Bi, Tmelt = 138°C
3.3. In-Ag, Tmelt = 143°C
3.4. In, Tmelt = 157°C
3.5. Pb-Sn, Tmelt =183°C
3.6. Optional type (can be
specified by Customer)
F. Thermistor (optional)
Can be mounted to ceramics
edge. Calibration is available
by request.
I. Thermistor mounting
Epoxy gluing
I. Pinout configuration
the drawing shows standard
pinout configuration. It can be
revised by request)
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page "1 of 13
"
Thermoelectric Cooling Solutions
Performance Data
PS28.2MC0405903AN
@27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-03AN
97
2.6
2.0
5.9
2MC04-059-03AN
104
2.9
2.0
6.5
110
120
100
110
90
100
90
80
80
70
70
dT, K
60
60
50
50
40
40
Voltage, V
30
30
20
20
10
10
8
6
6
4
4
2
2
0
0
0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20
0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20
Operating Current, A
Heatload, W
0.0
0.53
1.06
Operating Current, A
1.58
Heatload, W
2.11
@75ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-03AN
115.2
3.13
1.97
7.13
130
120
120
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
9
9
6
6
3
3
Voltage, V
dT, K
130
0
0.0
0.58
1.16
1.74
2.32
@85ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-03AN
119
3.2
2.0
7.3
0
0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20
0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20
Operating Current, A
Heatload, W
0.0
0.63
1.25
Operating Current, A
1.88
2.50
Heatload, W
0.0
0.64
1.28
1.93
Note: Performance data is specified at optimal heatsink. PS-28 Package Thermal Resistance (Rt) is included into estimations.
Please, use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page "2 of 13
"
2.57
Thermoelectric Cooling Solutions
Performance Data
PS28.2MC0405905AN
@27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-05AN
101
1.7
1.3
6.0
2MC04-059-05AN
107
1.9
1.3
6.6
110
120
100
110
90
100
90
80
80
70
70
dT, K
60
60
50
50
40
40
Voltage, V
30
30
20
20
10
10
8
6
6
4
4
2
2
0
0
0.20
0.40
0.60
0.80
1.00
1.20
1.40
0.20
0.40
Operating Current, A
Heatload, W
0.0
0.33
0.66
1.00
Heatload, W
1.33
@75ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-05AN
118
2.0
1.2
7.2
130
120
120
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
9
9
6
6
3
3
dT, K
130
Voltage, V
0.60
0.80
1.00
1.20
1.40
Operating Current, A
0
0.0
0.37
0.75
1.12
1.50
@85ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-05AN
122
2.0
1.2
7.4
0
0.20
0.40
0.60
0.80
1.00
1.20
1.40
0.20
Operating Current, A
Heatload, W
0.0
0.39
0.78
0.40
0.60
0.80
1.00
1.20
1.40
Operating Current, A
1.18
1.57
Heatload, W
0.0
0.40
0.80
1.21
Note: Performance data is specified at optimal heatsink. PS-28 Package Thermal Resistance (Rt) is included into estimations.
Please, use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page "3 of 13
"
1.61
Thermoelectric Cooling Solutions
Performance Data
PS28.2MC0405908AN
@27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-08AN
103
1.1
0.8
6.0
2MC04-059-08AN
106
1.2
0.8
6.7
110
120
100
110
90
100
90
80
80
70
70
dT, K
60
60
50
50
40
40
Voltage, V
30
30
20
20
10
10
8
6
6
4
4
2
2
0
0
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
0.10
0.20
Operating Current, A
Heatload, W
0.0
0.21
0.42
0.64
Heatload, W
0.85
0.50
0.60
0.70
0.80
0.90
0.0
0.24
0.48
0.72
0.96
@75ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@85ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-08AN
117
1.3
0.8
7.3
2MC04-059-08AN
121
1.3
0.8
7.5
130
120
120
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
9
9
6
6
3
3
dT, K
0.40
Operating Current, A
130
Voltage, V
0.30
0
0
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0.90
0.10
0.20
Operating Current, A
Heatload, W
0.0
0.26
0.52
0.30
0.40
0.50
0.60
0.70
0.80
0.90
Operating Current, A
0.78
1.04
Heatload, W
0.0
0.27
0.53
0.80
Note: Performance data is specified at optimal heatsink. PS-28 Package Thermal Resistance (Rt) is included into estimations.
Please, use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page "4 of 13
"
1.06
Thermoelectric Cooling Solutions
Performance Data
PS28.2MC0405910AN
@27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-10AN
103
0.9
0.7
5.9
2MC04-059-10AN
105
1.0
0.7
6.7
110
120
100
110
90
100
90
80
80
70
70
dT, K
60
60
50
50
40
40
Voltage, V
30
30
20
20
10
10
8
6
6
4
4
2
2
0
0
0.15
0.30
0.45
0.60
0.75
0.15
Operating Current, A
Heatload, W
0.0
0.17
0.34
0.51
Heatload, W
0.68
@75ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-10AN
116
1.1
0.7
7.3
130
120
120
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
9
9
6
6
3
3
dT, K
130
Voltage, V
0.30
0.45
0.60
0.75
Operating Current, A
0
0.0
0.19
0.39
0.58
0.78
@85ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-10AN
120
1.1
0.6
7.5
0
0.15
0.30
0.45
0.60
0.75
0.15
Operating Current, A
Heatload, W
0.0
0.21
0.42
0.30
0.45
0.60
0.75
Operating Current, A
0.63
0.84
Heatload, W
0.0
0.21
0.43
0.64
Note: Performance data is specified at optimal heatsink. PS-28 Package Thermal Resistance (Rt) is included into estimations.
Please, use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page "5 of 13
"
0.86
Thermoelectric Cooling Solutions
Performance Data
PS28.2MC0405912AN
@27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-12AN
104
0.7
0.6
6.0
2MC04-059-12AN
104
0.8
0.6
6.7
130
110
120
100
110
90
100
80
dT, K
90
80
70
70
60
60
50
50
40
40
30
30
20
Voltage, V
20
10
10
9
8
6
6
4
3
2
0
0
0.15
0.30
0.45
0.60
0.75
0.08
0.16
Operating Current, A
Heatload, W
0.0
0.14
0.29
0.43
Heatload, W
0.58
@75ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-12AN
114
0.9
0.6
7.4
130
120
120
110
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
9
9
6
6
3
3
dT, K
130
Voltage, V
0.24
0.32
0.40
0.48
0.56
0.64
Operating Current, A
0
0.0
0.16
0.32
0.49
0.65
@85ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-12AN
118
0.9
0.5
7.5
0
0.08
0.16
0.24
0.32
0.40
0.48
0.56
0.64
0.08
0.16
Operating Current, A
Heatload, W
0.0
0.18
0.35
0.24
0.32
0.40
0.48
0.56
0.64
Operating Current, A
0.53
0.70
Heatload, W
0.0
0.18
0.36
0.54
Note: Performance data is specified at optimal heatsink. PS-28 Package Thermal Resistance (Rt) is included into estimations.
Please, use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page "6 of 13
"
0.72
Thermoelectric Cooling Solutions
Performance Data
PS28.2MC0405915AN
@27ºC, Vacuum
ΔTmax
K
Qmax
W
Imax
A
Umax
V
@50ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-15AN
104
0.6
0.4
6.0
2MC04-059-15AN
102
0.7
0.5
6.7
110
100
100
90
90
80
80
70
70
60
60
50
50
40
40
30
30
20
20
10
10
Voltage, V
dT, K
110
8
6
6
4
4
2
2
0
0
0.10
0.20
0.30
0.40
0.50
0.10
Operating Current, A
Heatload, W
0.0
0.12
0.23
0.35
Heatload, W
0.46
@75ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-15AN
112
0.7
0.4
7.3
120
130
110
120
100
110
90
100
dT, K
0.30
0.40
0.50
0.0
0.13
0.26
0.39
0.52
@85ºC, Dry N2
ΔTmax
K
Qmax
W
Imax
A
Umax
V
2MC04-059-15AN
116
0.7
0.4
7.6
90
80
80
70
70
60
60
50
50
40
Voltage, V
0.20
Operating Current, A
40
30
30
20
20
10
10
9
9
6
6
3
3
0
0
0.10
0.20
0.30
0.40
0.50
0.10
Operating Current, A
Heatload, W
0.0
0.14
0.28
0.20
0.30
0.40
0.50
Operating Current, A
0.43
0.57
Heatload, W
0.0
0.15
0.29
0.44
Note: Performance data is specified at optimal heatsink. PS-28 Package Thermal Resistance (Rt) is included into estimations.
Please, use TECCad Software for estimations under different conditions or contact RMT Ltd or it’s branches directly.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page "7 of 13
"
0.58
Thermoelectric Cooling Solutions
Sub-assembly Overview
NTC Thermistor
2.2kOhm or
10kOhm
Thermistor (optional)
PS-28 (28pin) Package
(Material Kovar)
Thermoelectric Cooler
2MC04-059-xxAN
TE Cooler Lead Free
Internal Assembly Solder
(Lead-Free
Solder 230, Sn-Sb)
Flexible pinout configuration
for TEC and thermistor
TEC to Package High-Temperature
Mounting by Soldering
(Lead-Free Solder 206,
Sn-Ag-In-Bi,
vacuum flux-free process)
Laser Labeling (optional)
is available for Package
PS-28 (28pin) Package Drawing
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page "8 of 13
"
Thermoelectric Cooling Solutions
Thermoelectric Cooler Overview
Cold side Ceramics
(top side)
AlN Ceramics by default
(Al2O3 solution is available
by request)
Middle Ceramics
TE Cooler Lead Free
Internal Assembly
(Lead-Free Solder 230,
Sn-Sb)
Pellets (BiTe posts)
-
TEC Polarity
(can be modified by
request)
+
Hot Side Ceramics
(bottom side)
Terminal Wires
Application Tips
1. Never heat TE module more than 200˚C (TEC
assembled at 230˚C).
2. Never use TE module without an attached heat sink
at hot (bottom) side.
3. Connect TE module to DC power supply according
to polarity.
4. Do not apply DC current higher than Imax.
Installation
1. Mechanical Mounting. TEC is placed between two heat exchangers . This construction is fixed by screws or in
another mechanical way. It is suitable for large modules (with dimensions 30x30mm and larger). Miniature types
require other assembling methods in most cases.
1. Soldering. This method is suitable for a TE module with metallized outside surfaces. RMT provides this option
and also makes pre-tinning for TE modules.
2. Glueing. It is an up-to-date method that is used by many customers due to availability of glues with good
thermoconductive properties. A glue is usually based on some epoxy compound filled with some
thermoconductive material such as graphite or diamond powders, silver, SiN and others. The application of a
specific type depends on application features and the type of a TE module.
Object being cooled
Object being cooled
TEC
TEC
1
3
2
Screw mounting
Heatsink
Soldering
Heatsink
Gluing
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page "9 of 13
"
Thermoelectric Cooling Solutions
Additional Options
TEC Polarity
TEC Polarity can be modified by request. The
specified polarity in this datasheet is typical.
It can be reversed in accordance to Customer
application requirements.
-
+
+
Standard polarity
-
Reversed polarity
Terminal Wires Options
The wires are of tinned Copper, blank (not
insulated) by default. Various options for insulated
wires are available by request. The available
solutions include insulated wires, insulated colorcoded wires, flexible multicore wires and more.
S t a n d a rd w i re s ,
tinned Copper
Insulated wires
Customized Au Patterns
Customized Au patterns on thermoelectric cooler
cold side are available by request. Selective Pretinning over pattern is also available. Please,
contact RMT Ltd for additional information about
customized Au patterns requirements.
Customized Au pattern
on cold side
Selective pre-tinning
over pattern
Cold Side modification
TEC Cold Side can be modified by request. The
dimensions and shape of 2-stage thermoelectric
cooler can be revised to Customer application.
RMT Ltd has full-featured flexibility in TEC design
and modification.
Standard shape
Round-shaped
cold side
Standard height
Modified height,
another ceramics
thickness
TEC Height modification
Standard 2-stage TEC height can be modified
without performance changes by using ceramics
of different thickness. Standard 2-stage
thermoelectric cooler height (specified in this
datasheet) may be modified in a range
-0.75..+1.5mm by request.
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 10
" of 13
"
Thermoelectric Cooling Solutions
Important notes
1. TEC Performance in this datasheet is specified in typical ambient condition modes (Vacuum, +27ºC; Dry N2,
+50ºC; Dry N2, +75ºC; and Dry N2, +85ºC). The performance may differ under other conditions. Please, use RMT
TECCad software or iTECPad for iPad for detailed analysis or contact RMT or its branch specialists for additional
TEC performance info.
2. TEC ACR and Umax values are sensitive to ambient temperature. These values can be different from those
specified in the datasheet at other ambient conditions. ACR and Umax raise with ambient temperature increasing.
3. TEC cooling capacity (Qmax) raises with ambient temperature. Please, use RMT TECCad software or iPad app for
additional info, or contact RMT specialists directly.
4. Thermoelectric coolers have the best performance in the temperature range from near room up to +80..90ºC. TEC
cooling performance is less at ambient temperatures below 0ºC. TECs are not suitable to operate at cryogenic
temperatures.
5. Driving a TEC at Imax or Umax doesn’t mean max performance mode. The real optimal mode may depend on
operating conditions, required dT level and application heatload. In fact a better performance can be reached at
operating current and voltage lower than Imax and Umax values specified in this datasheet.
6. It is strongly recommended to avoid a direct mounting of thermoelectric cooler to pure Copper, Aluminium or
Nickel materials as well as a mounting of objects from these materials on TEC cold side. Any material with high
CTE (Coefficient of Thermal Expansion) may affect on TEC lifetime and even damage TEC in case of improper
mounting, thermal shock and/or temperature cycling. In case of above mentioned materials necessity, it is
recommended to use elastic “soft” solders or glues with large modulus of elasticity (Indium-based solders or
silicon-based thermoconductive glues).
7. RMT Ltd confirms that all RMT thermoelectric coolers are qualified and meet the requirements of Telcordia GR-468
Standard. The up-to-date Reliability Report is available by request. RMT Ltd warranties thermoelectric coolers
lifetime no less than 250K-300K operating hours under normal application conditions.
Application Tips
1. Never heat up the sub-assembly more than 200˚C.
2. Never use the sub-assembly without an attached
heatsink. Package is NOT a heatsink by itself.
3. Connect TE cooler to DC power supply according
to specified polarity.
4. Do not apply current/voltage higher than specified
max values
Mounting to TEC cold side
1. Soldering of object to be cooled.
Method suitable for a TE module with the metallized cold side
(Ordering Options. Item E). Soldering requires careful procedures:
A. Never overheat TEC (Application Tips. Item 1).
B. Use solder with melting point less than 200ºC.
2. Gluing of object to be cooled.
Method available by glues with good thermoconductive properties. Not recommended for high vacuum applications
and long operations at high temperature.
TEC
Mounting to the
cold side
Package
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 11
" of 13
"
Thermoelectric Cooling Solutions
Contacts
Russia - RMT Ltd. Headquarters
Warshavskoe sh. 46, 115230, Moscow
Russia
Tel: +7-499-678-2082
Fax: +7-499-678-2083
Web: www.rmtltd.ru
Email: [email protected]
Europe/USA - TEC Microsystems GmbH
Korea - Sunflower Energy
Schwarzschildstrasse 8, 12489 Berlin
1F, 665-6, Pungdeokcheon-dong
Germany
Suji-gu, Yongin-si, Gyeonggi-do
Tel: +49 30 6789 3314
South Korea
Fax: +49 30 6789 3315
Tel: +82 312767992
Web: www.tec-microsystems.com
Fax: +82 312767993
Email: [email protected]
web: www.sunfl.co.kr
China - ProTEC Ltd.
Taiwan - Wellspring & Vim Tech Corp
B
207
9F-1, No.657 Pei-an Rd.
+86-755-61596066
Taipei 104
+86-755-61596036
Taiwan
518054
Tel: +886 2-85091756
Web: www.protecltd.com
Fax: +886 2-85091846
Email: [email protected]
web: www.wellvim.com.tw
Email: [email protected]
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 12
" of 13
"
Thermoelectric Cooling Solutions
Legal Notice
All logos, images, trademarks and product names (collectively Materials) are proprietary to RMT Ltd and/ or any
of its affiliates, or subsidiaries, or other respective owners that have granted RMT Ltd the permission and/or
license to use such Materials. All images are provided by RMT Ltd. and are subjects of copyright protection.
RMT Ltd, TEC Microsystems GmbH and ProTEC Ltd. do not grant a copyright license (express or implied) to
the Recipient, except that Recipient may reproduce the logos, images and text materials in this press-release
without any alteration for non-promotional or editorial purposes only with a written note about materials owner.
Copyright Protection Warning
Graphics materials and texts from this datasheet may not be used commercially without a prior response in
writing on company letterhead and signed by RMT Ltd authority.
Thank you for respecting the intellectual property rights protected by the International Copyright laws.
All Images contain RMT hidden watermark for the immediate proof of their origin.
RMT Ltd.
RMT Image
Hidden Watermark
46 Warshavskoe shosse. Moscow 115230 Russia, ph: +7-499-678-2082, fax: +7-499-678-2083, web: www.rmtltd.ru
Copyright 2015. RMT Ltd. The design and specifications of products can be changed by RMT Ltd without notice.
Page 13