® MIAR03 SERIES DC/DC CONVERTER 3W, DIP-Package FEATURES ►Industrial Standard DIP-24 Package ►Fully Regulated Output Voltage ►I/O Isolation 1500 VDC ►Operating Ambient Temp. Range -40°C to +85°C ►Short Circuit Protection ►Designed-in Conducted EMI meets EN55022 Class A & FCC Level A ►UL/cUL/IEC/EN 60950-1 Safety Approval PRODUCT OVERVIEW The MIAR03 series is a range of isolated 3W DC/DC converter modules featuring fully regulated output voltages and narrow input voltage ranges.Excellent efficiency allow an operating temperature range of -40°C to +85°C (with Derating).The product comes in a DIP-24 Plastic package with alternative pinout which makes these converters also a perfect replacement for the popular S200R series.These DC/DC converters offer a very economical solution for many cost critical applications. Model Selection Guide Model Number MIAR03-05S05 MIAR03-05S12 MIAR03-05S15 MIAR03-05D12 MIAR03-05D15 MIAR03-12S05 MIAR03-12S12 MIAR03-12S15 MIAR03-12D12 MIAR03-12D15 MIAR03-24S05 MIAR03-24S12 MIAR03-24S15 MIAR03-24D12 MIAR03-24D15 Input Voltage (Range) Output Voltage VDC VDC 5 12 15 ±12 ±15 5 12 15 ±12 ±15 5 12 15 ±12 ±15 5 ±10% 12 ±10% 24 ±10% Output Current Input Current Max. capacitive Load Max. @Max. Load @No Load mA 600 250 200 ±125 ±100 600 250 200 ±125 ±100 600 250 200 ±125 ±100 mA(typ.) 857 769 769 769 769 338 313 313 309 305 167 156 156 154 152 mA(typ.) Efficiency (typ.) @Max. Load μF 470 100 100 100# 100# 470 100 100 100# 100# 470 100 100 100# 100# 90 45 22 % 70 78 78 78 78 74 80 80 81 82 75 80 80 81 82 # For each output Input Specifications Parameter Model Input Voltage Range Input Surge Voltage (1 sec. max.) Max. 5V Input Models 4.5 5 5.5 10.8 12 13.2 24V Input Models 21.6 24 26.4 5V Input Models -0.7 --- 7.5 12V Input Models -0.7 --- 15 24V Input Models -0.7 --- 30 --- --- 2000 All Models Conducted EMI Unit VDC mW Internal Pi Type Compliance to EN 55022,class A and FCC part 15,class A E-mail:[email protected] 2015/07/31 REV:2 Typ. 12V Input Models Short Circuit Input Power Input Filter Min. Tel:886-6-2923150 Page 1 of 4 ® MIAR03 SERIES DC/DC CONVERTER 3W, DIP-Package Output Specifications Parameter Conditions Output Voltage Setting Accuracy Min. Typ. Max. Unit --- --- ±2.0 %Vnom. Output Voltage Balance Dual Output, Balanced Loads Vin=Min. to Max. @Full Load ----- ±1.0 ±0.2 ±3.0 ±0.5 % Line Regulation Load Regulation Io=10% to 100% --- ±0.2 ±0.5 % 60 mV P-P Minimum.Load % No minimum Load Requirement Ripple & Noise 0-20 MHz Bandwidth --- Short Circuit Protection --- Continuous, Automatic Recovery General Specifications Parameter I/O Isolation Voltage Conditions Min. Typ. Max. Unit 60 Seconds 1500 --- --- VDC 1 Second 1800 --- --- VDC I/O Isolation Resistance 500 VDC 1000 --- --- MΩ I/O Isolation Capacitance 100KHz, 1V --- 300 --- pF --- 300 --- KHz Switching Frequency MTBF(calculated) MIL-HDBK-217F@25℃, Ground Benign Safety Approvals 700,000 Hours UL/cUL 60950-1 recognition (CSA certificate), IEC/EN 60950-1(CB-report) Environmental Specifications Parameter Operating Ambient Temperature Range (See Power Derating Curve) Conditions Min. Max. Natural Convection -40 +85 Unit ℃ ℃ Case Temperature --- +95 Storage Temperature Range -50 +125 ℃ Humidity (non condensing) --- 95 % rel. H 260 ℃ Cooling Natural Convection Lead Temperature (1.5mm from case for 10Sec.) --- Power Derating Curve Output Power (%) 100 80 Natural Convection 20LFM 60 400LFM 40 20 0 ~ -40 0 20 40 60 Ambient Temperature C E-mail:[email protected] 2015/07/31 REV:2 Tel:886-6-2923150 Page 2 of 4 80 100 110 ® MIAR03 SERIES DC/DC CONVERTER 3W, DIP-Package Notes 1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted. 2 We recommend to protect the converter by a slow blow fuse in the input supply line. 3 Other input and output voltage may be available, please contact factory. 4 That “natural convection” is about 20LFM but is not equal to still air (0 LFM). 5 Specifications are subject to change without notice. Package Specifications Pin Connections Pin Single Output 4.5 [0.18] 10.2 [0.40] Mechanical Dimensions 0.50 [0.02] 3 10 11 12 Bottom View 24 23 15 22 14 20.3 [0.80] 2 15.22 [0.60] 1 Dual Output 1 +Vin +Vin 2 NC -Vout 3 NC Common 10 -Vout Common 11 +Vout +Vout 12 -Vin -Vin 13 -Vin -Vin 14 +Vout +Vout 15 -Vout Common 22 NC Common 23 NC -Vout 24 +Vin +Vin 13 17.78 [0.70] 2x2.54 [2x0.10] 31.8 [1.25] 2x2.54 [2x0.10] 2.0 [0.08] 2.54 [0.10] NC: No Connection ►All dimensions in mm (inches) ►Tolerance: X.X±0.5 (X.XX±0.02) X.XX±0.25 ( X.XXX±0.01) ► Pin diameter 0.5 ±0.05 (0.02±0.002) Physical Characteristics Case Size : 31.8x20.3x10.2 mm (1.25x0.80x0.40 inches) Case Material : Non-Conductive Black Plastic (flammability to UL 94V-0 rated) Pin Material : Copper Alloy with Gold Plate Over Nickel Subplate Weight : 12.4g E-mail:[email protected] 2015/07/31 REV:2 Tel:886-6-2923150 Page 3 of 4 ® MIAR03 SERIES DC/DC CONVERTER 3W, DIP-Package Test Setup Peak-to-Peak Output Noise Measurement Test Use a Cout 0.33μF ceramic capacitor. Scope measurement should be made by using a BNC socket, measurement bandwidth is 0-20 MHz. Position the load between 50 mm and 75 mm from the DC/DC Converter. +Vin +Out Copper Strip Single Output DC / DC Converter -Vin Cout -Out Scope Resistive Load Copper Strip +Vin +Out Copper Strip Dual Output DC / DC Converter Com. Copper Strip -Vin -Out Copper Strip Scope Cout Resistive Load Cout Scope Technical Notes Maximum Capacitive Load The MIAR03 series has limitation of maximum connected capacitance at the output. The power module may be operated in current limiting mode during start-up, affecting the ramp-up and the startup time. The maximum capacitance can be found in the data sheet. Input Source Impedance The power module should be connected to a low ac-impedance input source. Highly inductive source impedances can affect the stability of the power module. In applications where power is supplied over long lines and output loading is high, it may be necessary to use a capacitor at the input to ensure startup. Capacitor mounted close to the power module helps ensure stability of the unit, it is recommended to use a good quality low Equivalent Series Resistance (ESR < 1.0Ω at 100 KHz) capacitor of a 4.7μF for the 5V input devices and a 2.2μF for the 12V and 24V devices. + DC Power Source +Vin + +Out DC / DC Converter Load Cin - -Vin -Out Output Ripple Reduction A good quality low ESR capacitor placed as close as practicable across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 1.5μF capacitors at the output. + +Vin - +Out Single Output DC / DC Converter DC Power Source -Vin + Cout Load -Out +Vin DC Power Source - +Out Dual Output DC / DC Com. Converter -Vin -Out Cout Load Load Cout Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 95℃. The derating curves are determined from measurements obtained in a test setup. Position of air velocity probe and thermocouple 15mm / 0.6in 50mm / 2in Air Flow DUT 18, Sin Sin Road, An-Ping Industrial District, Tainan 702, Taiwan Tel: 886-6-2923150 Fax: 886-6-2923149 E-mail: [email protected] Minmax Technology Co., Ltd. 2015/07/31 REV:2 Page 4 of 4