PRODUCT SPECIFICATION DATE:02/23/2004 Photolink : cosmo NO.60F00003 REV. KPLT1320AD ELECTRONICS CORPORATION SHEET 1 OF 4 FIBER OPTIC TRANSMITTING MODULE FOR DIGITAL AUDIO EQUIPMENT Features ● TTL interface. ● LED is driven by differential circuit. Applications ● Audio equipment. ● DVD player. ● Automobile. Outline Dimensions (Unit:mm) 20.20 9.50 0.50 2.30 4.70 3.80 7.62 2.54 1 11.20 Tolerance:±0.2mm 9.50 2 11.50 3 2.54 3.55 4.00 1.90 1.60 6.00 11.10 8.20 13.50 6.50 Pin Connection 1.GND 2.Vcc 3.Input 1 PRODUCT SPECIFICATION DATE:02/23/2004 cosmo Photolink : ELECTRONICS CORPORATION NO.60F00003 REV. KPLT1320AD SHEET 2 OF 4 1 1. Maximum Ratings(Ta=25℃) Parameter Symbol Rating Unit ℃ Storage Temperature Tstg -40~80 ℃ Operating Temperature Topr -20~70 Power Dissipation Pmax 120 mW Supply Voltage Vcc -0.5~7 V Input Voltage VIN -0.5~Vcc+0.5 V ℃ 260(Note 1) Soldering Temperature Tsol Note 1:Soldering time ≦ 10 seconds(At a distance of 1 mm from the package). 2. Recommended Operating Conditions Parameter Supply Voltage High-Level Input Voltage Low-Level Input Voltage Symbol Min Typ. Max Unit VCC VIH VIL 4.75 2.0 0 5.0 - 5.25 VCC 0.8 V V V 3. Electrical and Optical Characteristics(Ta=25℃,VCC=5V) Min Typ. Max Unit NRZ Signal Data Rate DC (Note 3) Using APF 0.2 Transmission Distance (Note 4) Fiber Output Power Pf -21 Peak Emission Wavelength λp 630 Current Consumption Icc High Level Input Voltage VIH 2.0 Low Level Input Voltage VIL Low->High Propagation delay tPLH time High -> Low Propagation delay tPHL time △tw Pulse Width Distortion 6Mbps NRZ Signal -25 △tj Jitter Time Note 2:LED is on when input signal is high, and off when it is low. The duty factor must be maintained between 25 to 75%. Note 3:All Plastic Fiber(970 / 1000nm). Note 4:Measure with a standard optical fiber, peak value. 13.2 Mb/s 5 m -15 dBm 650 690 nm 13 mA V 0.8 V Parameter Symbol Condition (Note 2) - 150 ns 150 ns 25 25 ns ns PRODUCT SPECIFICATION DATE:02/23/2004 Photolink : cosmo ELECTRONICS CORPORATION NO.60F00003 REV. KPLT1320AD SHEET 3 OF 4 4. Measuring method (1).Measuring method of optical output coupling fiber PHOTOLINK Unit Standard optical fiber cable Optical Power Meter to be measured Vin Vcc GND Optical Power Meter must be calibrated to have the wavelength sensitivity of 650nm | 0 dBm=1mW | (2).Measuring method of power dissipation current and input voltage PHOTOLINK Unit Standard optical fiber cable Optical Power Meter to be measured Vin Vcc GND Optical Power Meter must be calibrated to have the wavelength sensitivity of 650nm | 0 dBm=1mW | Icc Vin Vcc (3).Measuring method of Pulse response Standard optical fiber cable PHOTOLINK Unit Standard receiver to be measured Vin Vcc GND Vcc CH1 CH2 Oscilloscope Input Output signal Input signal 6Mbps NRZ"1010" successive pattern Input signal (CH1) Input signal (CH1) 50% Output signal (CH2) 50% Output signal (CH2) VOH 90% 50% 50% 10% VOL t PLH t PHL △tw= t PHL - t PLH tr tf 1 PRODUCT SPECIFICATION DATE:02/23/2004 Photolink : cosmo NO.60F00003 REV. KPLT1320AD ELECTRONICS CORPORATION SHEET 4 OF 4 1 (4).Measuring method of Jitter Standard optical fiber cable PHOTOLINK Unit Standard receiver to be measured Vin Vcc GND Vcc CH1 CH2 Oscilloscope Input Output signal 1 1 0 0 Input signal (CH1) 50% Output signal (CH2) 50% △ tj △ tj 5.Recommended PCB Layout 7.62 3.80 2- 2.8 3- 2.54 0.8 2.54 Notes: 1.Unit:mm 2.tolerance:±0.3mm