General Description
PS252C1 is specially designed for switching power supply system. Four important
functions of PS252C1 are the followings: over-voltage protection, over-current
protection, under-voltage protection and power good signal generating.
OVP/UVP (Over-Voltage/Under-Voltage Protection) monitors dual 12V to protect
our power supply and PC, FPO/ goes to high when one of these supply voltages
exceeds their normal operation voltage range.
OCP (Over Current Protection) monitors IS12A, IS12B input current sense. An
adjustable over-current condition composed of Iref and “protection current range
resistor” helps users design OCP easily.
An additional protection input pin provides the flexibility for design protection
circuit.
Power good signal generating notifies personal computer when power supply is
ready or power supply is going to shutdown, therefore it can provide a reliable power
supply environment.
Features
•
•
•
•
•
•
•
•
•
•
Over/Under-voltage protection and lock out
Over-current protection and lock out
Additional protection input
Fault protection output with open drain output stage
Open drain power good output signal for power good input
Built-in 300mS power good delay
AC on 75ms delay for UV/OC protection
38mS PSON/ control de-bounce
Wide power supply range (3.8V~16V)
Special care for AC power off
2-Channel Secondary Monitoring IC
Version:A.003
未經授權而逕予重製、複製、使用或公開本文件,行為人得被追究侵權之相關民刑事責任
Unauthorized reproduction, duplication, use or disclosure of this document will be deemed as infringement.
PAGE 1
PS252C1
Block Diagram
VS12A
136K
FPO/
delay
12 UV
S Q
4.96K
Vref
22uS
R
1MΩ
12 OV
14.04K
Vref
delay
38mS
De-bounce
H : 4mS
L : 4.5uS
VS12B
136K
12 UV
4.96K
Vref
14.04K
Vref
VCC
30KΩ
12 OV
VCCI
2KΩ
PSON/
Vref
4.5V
90KΩ
delay
H : 75mS
L : 4.5uS
PGI
Selection
PGI
1.25V
VCCI
1MΩ
PGO
delay
73uS
De-bounce
H : 300mS
L : 4.5uS
delay
delay
53uS
53uS
Pext
VCCI
IS12A
1.2V
Step Down
to near 2.5V
12 OC
delay
Power On
Reset
IIS_SINK
IS12B
Step Down
to near 2.5V
POR
Constant Current
Source Iref
RI
H : 20mS
L : 4.5uS
VCCI
12 OC
IIS_SINK
Internal
Power
VCCI = 4V
VCC
Band-Gap
Reference
2-Channel Secondary Monitoring IC
Vref
1.25V
Clock
Generator
Version:A.003
未經授權而逕予重製、複製、使用或公開本文件,行為人得被追究侵權之相關民刑事責任
Unauthorized reproduction, duplication, use or disclosure of this document will be deemed as infringement.
CLK
VCC
GND
PAGE 2
PS252C1
Timing Chart
Vcc
PSON/
FPO/
PGI
VS12A IS12A
VS12B IS12B
Pext
PGO
Td1
Tb1
Td3
Td2
AC
turn on
VPGI
UVP/OVP/OCP
Pext protect
PSON/
turn on
PSON/
turn off
1.25V
PSON/
turn on
AC
turn off
1.12V
0.65V
Td1
Td2
OVP
2-Channel Secondary Monitoring IC
OVP/UVP/OCP/Pext
OVP
Version:A.003
未經授權而逕予重製、複製、使用或公開本文件,行為人得被追究侵權之相關民刑事責任
Unauthorized reproduction, duplication, use or disclosure of this document will be deemed as infringement.
PAGE 3
PS252C1
Pin Descriptions
Pin No
1
PIN NAME
PGI
Descriptions
Power good input signal pin
2
GND
Ground
3
FPO/
Inverted fault protection output ,open drain output stage
4
PSON/
Remote ON/OFF control input pin
5
RI
Current sense setting
6
IS12B
12V(2) over current protection input pin
7
VS12B
12V(2) over/under voltage protection input pin
8
Pext
External protection detect input pin
9
IS12A
12V(1) over current protection input pin
10
VS12A
12V(1) over/under voltage protection input pin
11
None
12
None
13
VCC
Power supply
14
PGO
Power good output signal pin , open drain output stage
Absolute Maximum Ratings
Parameter
Storage Temperature
Rating
Unit
(Tstg)
-40 to
+125
°C
Operating Temperature (Topr)
-30 to
+90
°C
VCC
-0.5 to
+16.0
V
VS12A, VS12B, IS12A,IS12B
-0.5 to
+16.0
V
Pext
-0.5 to
+7.0
V
PGI
-0.5 to
+16.0
V
PSON/
-0.5 to
Vcc+0.5
V
FPO/
-0.5 to
Vcc+0.5
V
PGO
-0.5 to
Vcc+0.5
V
RI
12.5 to
62.5
uA
>
2000
V
Supply Voltage
(VCC)
Input Voltage Range
(VI)
Output Voltage Range
(VO)
Output Current for RI
(IRI)
ESD Susceptibility*
(VESD)
* Human Body Model (HBM).
2-Channel Secondary Monitoring IC
Version:A.003
未經授權而逕予重製、複製、使用或公開本文件,行為人得被追究侵權之相關民刑事責任
Unauthorized reproduction, duplication, use or disclosure of this document will be deemed as infringement.
PAGE 4
PS252C1
Electrical Characteristics, Vcc=12V, Ta = 25°C. (unless otherwise specified)
Power Supply Section
Parameter
Conditions
MIN
Supply Voltage
3.8
Supply Current
VPSON/ = 5V
Power On Reset Threshold Voltage (VPOR)
Power On Reset Hysteresis (VHYST)
3.2
TYP
MAX
Unit
5.0
16.0
V
4.5
5.0
mA
3.4
3.6
V
-0.45
V
High->Low
Over-Voltage Section
Parameter
Conditions
MIN
VS12A/B Over-Voltage Threshold
13.3
TYP
13.8
MAX
14.2
Unit
V
Under-Voltage Section
Parameter
Conditions
MIN
VS12A/B Under-Voltage Threshold
9.8
TYP
10.2
MAX
10.6
Unit
V
PSON/, Analog Input
Parameter
Conditions
MIN
Threshold Voltage ( High )
TYP
MAX
1.60
Unit
V
Threshold Voltage ( Low )
0.85
V
PGI, Analog Input
Parameter
Conditions
MIN
TYP
MAX
Unit
Threshold Voltage for start Td2
0.58
0.65
0.73
V
Threshold Voltage for start Td1
1.16
1.25
1.33
V
+/-20
+/-50
+/-80
mV
Hysteresis (VHYST)*
* All of the comparator for PGI input in block diagram.
2-Channel Secondary Monitoring IC
Version:A.003
未經授權而逕予重製、複製、使用或公開本文件,行為人得被追究侵權之相關民刑事責任
Unauthorized reproduction, duplication, use or disclosure of this document will be deemed as infringement.
PAGE 5
PS252C1
Electrical Characteristics (Continued)
PGO, Open Drain Digital Output
Parameter
Conditions
Leakage Current (ILKG)
VPGO=5V
Low Level Output Voltage (VOL)
ISINK=10mA
MIN
TYP
MAX
Unit
5
uA
0.3
V
Over-Current Section
Parameter
Conditions
MIN
TYP
-5
0
5
9.0
10.0
10.75
TYP
MAX
VS12A/B Offset Voltage
Constant VRI multiply Current Gain ( K )
MAX
Unit
mV
FPO/, Open Drain Digital Output
Parameter
Conditions
Leakage Current (ILKG)
VFPO/=5V
Low Level Output Voltage (VOL)
ISINK=20mA
MIN
Unit
5
uA
0.4
V
External Protection Detect Section
Parameter
Conditions
MIN
Threshold(VTH)
TYP
1.15
Hysteresis (VHYST)
MAX
Unit
1.20
1.25
V
+/-20
+/-50
mV
Switching Characteristics, Vcc=12V, Ta = 25°C.
Parameter
Conditions
MIN
PGI to PGO Delay Time (Td1)
Short Circuit Delay Time (Td2)
TYP
200
PGI< 0.65V
300
400
Unit
mS
Disable UV/OC Pretection
49
75
114
mS
PGO to FPO/ Delay Time (Td3)
2
4
6
mS
Under Voltage Delay Time (Td4)
47
73
110
uS
Over Current Delay Time (Td5)
13
20
27
mS
Over Voltage Delay Time (Td6)
15
22
30
uS
Pext Delay Time (Td7)
47
73
110
uS
PSON/ De-bounce Time (Tb1)
24
38
61
mS
PGO Noise De-glitch Time (Tb2)
47
73
100
uS
2-Channel Secondary Monitoring IC
PGI> 0.65V
MAX
Version:A.003
未經授權而逕予重製、複製、使用或公開本文件,行為人得被追究侵權之相關民刑事責任
Unauthorized reproduction, duplication, use or disclosure of this document will be deemed as infringement.
PAGE 6
PS252C1
Application
Typical 2 rails SPS
S.P.S. Secondary Side
RS12 A
+12VA Output
+12VA Coil
RS 12 B
+12VB Coil
+12VB Output
VDET
R OC12A
R OC12B
R PGO
4.7K
R PGI-1
CPGI-1
1 PGI
PGO 14
Vcc 13
3 FPO/
None 12
PSON
4 PSON/
None 11
5 RI
VS12A 10
1K
C 12B-1 0.1 uF
6 IS12B
IS12 A 9
7 VS12 B
PEXT 8
+5V SB
C 12A-1 0.1 uF
2 GND
+5V SB
PGO
Pext
C PGO 0.1 uF
Cby
RI
RPGI-2
CPGI-2
CPS ON 0.1 uF
C 12A-2 0.1 uF
C 12B-2 0.1 uF
Notes:
1. Zener diode or resistor or both of them can be used in component X.
2. The bypass capacitor Cby suggests to be 0.1uF~ 10uF and layout nearby pin VCC.
3. The recommend sense values of RS12A, RS12B are ≥ 0.002Ω.
4. Over-Current Protection design example:
K
10
(1) RI = 62.5 K (Ω) , I IS _ SINK =
=
= 160(uA)
RI 62.5K
(2) RS12A=0.002 Ω , ΔV12VA = 0.002 × I +12VA = ROC12 A × I IS _ Iink
(3) If 12VA OCP trip point is 20A, ROC12 A =
2-Channel Secondary Monitoring IC
0.002 × 20
= 250(Ω )
160μ
Version:A.003
未經授權而逕予重製、複製、使用或公開本文件,行為人得被追究侵權之相關民刑事責任
Unauthorized reproduction, duplication, use or disclosure of this document will be deemed as infringement.
PAGE 7
PS252C1
Package Specification
2-Channel Secondary Monitoring IC
Version:A.003
未經授權而逕予重製、複製、使用或公開本文件,行為人得被追究侵權之相關民刑事責任
Unauthorized reproduction, duplication, use or disclosure of this document will be deemed as infringement.
PAGE 8
PS252C1
The products listed herein are designed for ordinary electronic applications, such as
electrical appliances, audio-visual equipment, communications devices and so on.
Hence, it is advisable that the devices should not be used in medical instruments,
surgical implants, aerospace machinery, nuclear power control systems,
disaster/crime-prevention equipment and the like. Misusing those products may
directly or indirectly endanger human life, or cause injury and property loss.
Silicon Touch Technology, Inc. will not take any responsibilities regarding the
misusage of the products mentioned above. Anyone who purchases any products
described herein with the above-mentioned intention or with such misused
applications should accept full responsibility and indemnify. Silicon Touch Technology,
Inc. and its distributors and all their officers and employees shall defend jointly and
severally against any and all claims and litigation and all damages, cost and
expenses associated with such intention and manipulation.
Silicon Touch Technology, Inc. reserve the right to make changes to their products or
to discontinue any product or service without notice, and advise customers to obtain
the latest version of relevant information to verify, before placing orders, that
information being relied on is current and complete.
2-Channel Secondary Monitoring IC
Version:A.003
未經授權而逕予重製、複製、使用或公開本文件,行為人得被追究侵權之相關民刑事責任
Unauthorized reproduction, duplication, use or disclosure of this document will be deemed as infringement.
PAGE 9