HIGH FREQUENCY BALUN ADAPTER For 150 Ω Fibre Channel , 100 Ω Gigabit Ethernet and 78 Ω High Speed 1553 Specialty Components Transforms a balanced differential signal to a 50 Ω, grounded, unbalanced signal for testing differential cable Designed for standard test equipment with SMA connectors Wide bandwidth 1.0 MHz – 1.2 GHz Operating temperature range from 0° C to 70° C Electrical Specifications @ 25°C — Operating Temperature 0° C to +70° C Part Number* HFB050150 HFB050100 HFB050078 Insertion Loss (dB MAX) 1.0 MHz - 1.2 GHz -2 -2 -2 Impedance (Ω) Unbalanced 50 50 50 Balanced 150 100 78 Return Loss (dB MIN) 1.0 MHz - 1.2 GHz 15 15 15 * NOTE: Patent pending Mechanical Schematic HFB050XXX 1.140 MAX 28,96 1 SPECIALTY COMPONENTS 1 3 50 W 50 W 1.510 MAX 38,35 150 W 3 150 W 2 HFB050XXX SERIAL NO. CONNECTOR, SMA, 50 W CONNECTOR, HEADER 3 SOCKETS o.025 - .035 FITS PINS 0,64 - 0,89 .900 MAX 22,86 Dimensions: Inches mm Unless otherwise specified, all tolerances are ± .010 0,25 2 1 3 2 Weight . . . . . . .40.0 grams MAX Packaging . . . . . . . . .1 per box TWO PEARL BUCK COURT • BRISTOL, PA 19007-6812 • TEL 215-781-6400 • FAX 215-781-6403 • www.pulsespecialty.com M100.P (6/00) HIGH FREQUENCY BALUN ADAPTER Specialty Components For 150 Ω Fibre Channel , 100 Ω Gigabit Ethernet and 78 Ω High Speed 1553 Application Notes: The Specialty Components Division has developed a high frequency BALUN for test and measurement applications. Wide bandwidth and high frequency response makes this device ideal for differential mode measurement in high speed applications such as Fibre Channel, Gigabit Ethernet and next generation MIL-STD-1553. The BALUN allows design engineers to characterize differential mode devices using single-ended test equipment as shown below. Typical Return Loss - S11 Typical Insertion Loss - S21 50 ohm Unbalanced Port Two Baluns Configured Back to Back 2 dB/div Attenuation (dB) -15 dB Attenuation (dB) 0 dB .5 dB/div -4 dB 1.0 MHz Frequency (MHz) NETWORK ANALYZER CH-1 CH-2 DUT #1 1.0 MHz 1.2 GHz Frequency (MHz) 1.2 GHz Insertion loss S21 is measured with two units connected back to back as shown. Note 1: Correct value of S21 for each DUT will be 1/2 of the value shown in graph. Note 2: Return loss S11 is measured on 50 ohm port with 150 ohms termination on balance port. DUT #2 150 W TWINAX CABLE NETWORK ANALYZER 1 50 W USER’S DIFFERENTIAL INTERFACE 3 2 PSC BALUN P/N HFB050150 For More Information : Specialty Components Division Two Pearl Buck Court Bristol, PA 19007-6812 USA TEL: 215 781 6400 FAX: 215 781 6403 http://www.pulsespecialty.com Performance warranty of products offered on this data sheet is limited to the parameters specified. Data is subject to change without notice. Other brand and product names mentioned herein may be trademarks or registered trademarks of their respective owners. Printed on recycled paper. ©2000, Pulse Engineering, Inc. M100.P (6/00)