SPECIFICATION FOR APPROVAL

SPECIFICATION
FOR
APPROVAL
CUSTOMER:
PRODUCTS:
MAGNETIC TRANSDUCER
MODEL:
ST-0503
DIMENSIONAL:
5.0× 5.0× 3.0
CUSTOMER
CHECKED BY
211 N. First Street
Minneapolis, MN. 55401
612-849-6205
www.soberton.com
The Specification is confidential.
APPROVED BY
SPECIFICATIONS FOR TRANSDUCER
The Specification is confidential.
1.0 DESCRIPTION AND APPLICATION
This is a miniature electro-magnetic transducer. The transducer is recommended to be used for clock,
telephone, modem, etc; this transducer is ROHS compliant.
2.0
SPECIFICATIONS
NO.
ITEMS
SPECIFICATIONS
2-1
Rated Voltage
3.0
2-2
Operating Voltage
2.0 ~ 4.0 VDC
2-3
* Rated Current
100 mA (Max.)
2-4
Coil DC Resistance
12±2
2-5
* Sound Output at 10 cm
78 dBA(Min.)
2-6
Rated Frequency
4000 Hz
2-7
Housing Material
LCP
2-8
Weight
0.1 g
2-9
Operating
range
temperature
2-10 Storage temperature range
VDC
-30℃ to +70℃
-40℃ to +85℃
*Measure value at rated voltage (3.0VDC) and rated frequency (4000 Hz, 1/2 duty square wave.).
SPECIFICATIONS FOR TRANSDUCER
The Specification is confidential.
3.0
FREQUENCY RESPONSE
A : Frequency Response, Magn dB re 20.00µPa
100
90
80
dB
70
60
50
100
1000
Frequency(Hz)
4.0
STRANDARD DRIVE CIRCUIT
10000
SPECIFICATIONS FOR TRANSDUCER
The Specification is confidential.
5.0
6.0
INSPECTION TEST FIXTURE
FRAMEWORK AND MATERIAL
4
3
2
5
6
7
8
1
NO.
1
2
3
4
5
6
7
8
NAME
BASE
MAGNET
DIAPHRAGM
UPPER COVER
COIL
WEIGHT
IRON CORE
TERMINAL PAD
MATERIAL
LCP
SmCo
ALLOY OF IRON & NICKEL
STAINLESS
ENAMELLED
Fe
Fe
Cu
STEEL
WIRE
SPECIFICATIONS FOR TRANSDUCER
The Specification is confidential.
7.0 RELIABILITY TEST
No
7-1
7-2
7-3
Item
Low
temperature
storage
High
temperature
storage
Condition
Storage in -40℃ test box for 96 hours, then expose to room temperature for 2 to
4 hours.
Storage in +85℃ test box for 96 hours, then expose to room temperature for 2 to
4 hours.
Temperature
Cycle
7-4
Static
Humidity
7-5
Random
Vibration
20 second Max. Transition time between Temp. extremes
Precondition at +25℃ for 1 hour. Then expose to +70℃ with 90 to 95% relative
humidity for 240 hours. Finally allow to dry at room ambient for 2 to 4hours
before taking final measurements.
Vibrate randomly from 20 to 2000Hz using the following PSD profile. It is a +3
2
dB/octave from 20Hz to 80Hz,then 0.053 g /Hz
from 80Hz to 350Hz,and
finally at -3dB/octave from 350Hz to 2000Hz.The PSD tolerance is ±
3dB from
20 to 1000Hz and ±6dB above 1000Hz.The Analyzer Bandwidth to be set at
25Hz BW from 20 to 200Hz, 50Hz BW to 1000Hz, and finally 100Hz BW to
2000Hz.The test time is 15 minutes per plane.
7-6
Drop Test
7-7
Operating
Life
Lead Pull
Test
7-8
The Buzzer that is attached to a 100 gram fixture is dropped to concrete floor
from 1.5 meters height. Drop three times in each of the six planes.
Subject samples to +85℃for 1000 hours under rated power.
Subject test leads to an increasing pull force between the lead and the transducer
until destruction occurs. Record the point of destruction .The minimum pull
strength is 1000 grams.
SPECIFICATIONS FOR TRANSDUCER
The Specification is confidential.
7-9
Reflow
Soldering
Recommendable reflow condition :
Temp.ㄗ⊥ㄘ
245⊥
220⊥
200⊥
150⊥
50⊥
Timeㄗsecㄘ
7-10
Judgment
At reliability
1
Change in sound output should be within =75 dB and tone quality is allowed.
2
No significant change both in appearance and structure .
SPECIFICATIONS FOR TRANSDUCER
The Specification is confidential.
8.0
MECHANICAL DRAWING
Lead(+)
Dummy Lead
Lead(-)
Dummy Lead
Sound Port
All dimensions are in mm
Tolerance: ±0.2 mm
9.0
SOLDERING PATTERN
All dimensions are in mm,
Tolerance: ±0.2 mm
SPECIFICATIONS FOR TRANSDUCER
The Specification is confidential.
10.0
PACKING REQUIREMENTS
SPECIFICATIONS FOR TRANSDUCER
The Specification is confidential.
VOLUME 36X36X26CM
List of packing
1 reel
1 CARTON
1000 PCS PRODUCTS
10000 PCS PRODUCTS