WT-1205 Spec

SPECIFICATION
FOR
APPROVAL
Customer:
Description: Magnetic Transducer
Sob erton Part No. : WT-1205
Date:2008-10-13
Customer Model No. :
Date of Approval
Authorization
Signature
211 N. First Street
Minneapolis, MN. 55401
612-849-6205
Http://www.sob erton.com E-mail: info@sob erton.com
Approved
Checked
Design
Ryan
Wang Wei Rong
Xu Hong Wei
2008/10/01
2008/10/01
2008/10/01
A:SCOPE
This specification applies magnetic transducer, WT-1205
2/7
B:SPECIFICATION
■ Test condition: TEMP=+25±2 ℃ Related humidity=65±5% Air pressure:860-1060mbar
NO.
Item
Unit
Specification
Condition
Rated Voltage
Vo-p
1
Vo-p
5.0
2
3
4
5
6
7
8
9
10
11
12
13
14
Operating Voltage
Mean Current
Coil Resistance
Sound Output
Rated Frequency
Operating Temp
Storage Temp
Dimension
Weight
Vo-p
mA
Max. 40
Ω
47 ± 15%
dBA
87 at 10cm
Hz
2400
℃
-20 ~ +70
℃
-30 ~ +80
mm
Φ 12.0 × H 9.8
gram
2.0
Material
0V
Applying rated voltage & rated frequency,
square wave 1/2 duty
Distance at 10cm(A-weight free air), Applying
rated voltage & rated frequency, square
wave,1/2duty
See attached drawing.
PBT (Black)
Terminal
Pin type
Environmental
Protection
Regulation
Storage life
4.0 - 6.0
See attached drawing
RoHS Compliant
month
3
3 months preservation at room temp(25±3℃),
Humidity40%
3/7
C:ENVIRONMENT TEST
No.
1
2
Item
Test condition
Evaluation standard
High temp. test
After being placed in a chamber at +70℃ for 96
hours.
Low temp. test
After being placed in a chamber at -30℃ for 96
hours.
The part shall be subjected to 10 cycles. One
cycle shall consist of;
+70℃
3
Thermal shock
-30℃
30min
30min
60min
The part shall be subjected to 10 cycle and consist
of;
4
+70℃
Temp. / Humidity Cycle
After the test the part
shall meet
specifications without
any degradation in
appearance and
performance except
SPL. after 4 hours at
+25℃, The SPL shall
be in ± 10 dBA
compared with initial
one.
a, b: 90~98%RH
c: 80~98%RH
+25℃
a
b
3hrs
12±0.5hrs
3hrs
c
24hrs
D: RELIABILITY TEST
No.
Item
Test condition
□ Applying rated voltage, rated frequency, square wave ,
1/2 duty cycle:
1
Operating
life test
Ordinary temperature
The part shall be subjected to 96 hours at room
temperature.
TEST CONDITION.
Standard Test Condition
: a)Temperature: +5~+35℃ b)Humidity:45~85%
Judgment Test Condition :a)Temperature:+25±2℃
b)Humidity:60~70%
Evaluation standard
After the test the part shall
meet specifications without
any degradation in
appearance and performance
except SPL. after 4 hours at
+25℃,The SPL shall be in ±
10 dBA compared with
initial one.
c)Pressure: 860~1060mbar
c)Pressure: 860~1060mbar
4/7
Evaluation standard
95% Min. lead
terminals shall be wet
with solder
E:MECHANICAL CHARACTERISTICS
No
Item
Test condition
Lead terminal are immersed in rosin for 5 seconds and
then immersed in Solder bath of +260±5℃ for 3±0.5
Solder ability
1
second
2
3
4
5
6
Soldering Heat Lead terminal are immersed in soldering bath of
Resistance
+260±5℃ for 5±0.5 Second.
Hand Soldering
Lead terminal are soldering of +350±5℃, 2.0±0.5
Heat Resistance
Second.
Terminal
Mechanical
Strength
Vibration
Drop test
No interference in
operation
Apply the terminal with 9.8N(1kg) strength for 10±1 sec.
The part shall be subjected to a vibration cycle of 10Hz
to 55Hz in a period of 1 minute. Total peak amplitude
shall be 1.52mm(9.3G). The vibration test shall consist of
2 hours per axis in each three axes(X、Y、Z).
The part only shall be dropped from a height of 75cm
onto a 40mm think wooden board 1 times.
No damage and cutting
off
After the test the part
shall meet specifications
without any damage in
appearance and
performance except
SPL. The SPL shall be
in ± 10 dBA compared
with initial one.
(
)
* Wave Soldering profile of lead-free
Temp.(° C)
Max. 10 sec.
250°C
245°C
235°C
200K/s--130°C
---5K/s
100°C
---forced cooling
50°C
0
0
50
100
150
200
250
300
Time(sec)
Recommendable wave soldering condition is as follows.
Note 1: It is requested that wave soldering should be executed after
heat of product goes down to normal temperature.
Note 2: Peak wave temperature of 235°C ~ 250° C maximum of 10 sec. .
5/7
F: MEASUREMENT METHOD
+Vcc
BZ
Vo-p
Magnetic
Transducer
180
VCE
OV
G: INSPECTION FIXTURE
Magnetic Transducer
40cm
10cm
Sound Level Meter TES1350A