WST-1310S

SPECIFICATION
FOR
APPROVAL
Customer:
Description: Magnetic Transducer
Sob erton Part No. : WST-1310S-3
Date:2012-02-01
Customer Model No. :
Date of Approval
Authorization
Signature
211 N. First Street
Minneapolis, MN. 55401
612-849-6205
info@sob erton.com
Approved
Checked
Design
Ryan
Wang Cheng
Song Qi
2012/02/01
2012/02/01
2012/02/01
A:SCOPE
This specification applies magnetic buzzer, WST-1310S-3
B:SPECIFICATION
■Test condition: TEMP=+25±2 ℃
NO.
1
2
3
4
5
6
7
8
Item
Rated Voltage
Operating Volt
Mean Current
Sound Output
Rated Frequency
Operating Temp
Storage Temp
Dimension
9
Weight
10
Material
11
12
13
Terminal
Unit
Specification
Vo-p
12
Vo-p
Vo-p
8.0 ~16.0
0V
mA
Max.30
Peak 100
Air pressure:860-1060mbar
Condition
Applying rated voltage.
Distance at 10cm(A-weight free air), Applying rated
dBA
85/10cm
Hz
2300±300Hz
℃
-20-+70
℃
-30-+80
mm
12.8*12.8*10
gram
2.5
voltage.
See attached drawing.
PPS (Gray)
Pin type
Environmental
Protection Regulation
Storage life
Related humidity=65±5%
Tin plated
See attached drawing
RoHS
3 months preservation at room temp(25±3℃),
month
3
Humidity40%.
C:ENVIRONMENT TEST
No.
1
2
Item
Test condition
Evaluation standard
High temp. test
After being placed in a chamber at +85℃ for 96
hours.
Low temp. test
After being placed in a chamber at -30℃ for 96
hours.
The part shall be subjected to 10 cycles. One
cycle shall consist of;
+85℃
3
Thermal shock
-30℃
30min
30min
60min
The part shall be subjected to 10 cycle and consist
of;
4
+85℃
Temp. / Humidity Cycle
After the test the part
shall meet
specifications without
any degradation in
appearance and
performance except
SPL. after 4 hours at
+25℃, The SPL shall
be in ± 10 dBA
compared with initial
one.
a, b: 90~98%RH
c: 80~98%RH
+25℃
a
b
3hrs
12±0.5hrs
3hrs
c
24hrs
D: RELIABILITY TEST
No.
Item
Test condition
□ Applying rated voltage, rated frequency, square wave ,
1/2 duty cycle:
1
Operating
life test
1. Ordinary temperature
The part shall be subjected to 96 hours at room
temperature.
Evaluation standard
After the test the part shall
meet specifications without
any degradation in
appearance and performance
except SPL. after 4 hours at
+25℃,The SPL shall be in ±
10 dBA compared with
initial one.
2. High temperature
The part shall be subjected to 96 hours at +85℃ with
12V applied.
TEST CONDITION.
Standard Test Condition
: a)Temperature: +5~+35℃ b)Humidity:45~85%
Judgment Test Condition :a)Temperature:+25±2℃
b)Humidity:60~70%
c)Pressure: 860~1060mbar
c)Pressure: 860~1060mbar
E:MECHANICAL CHARACTERISTICS
No
Item
Test condition
Lead terminal are immersed in rosin for 5 seconds and
then immersed in Solder bath of +245±5℃ for 3±1
Solder ability
1
second
2
3
4
5
6
Evaluation standard
95% Min. lead
terminals shall be wet
with solder
Soldering Heat Lead terminal are immersed in soldering bath of
Resistance
+260±5℃ for 5±0.5 Second.
Hand Soldering
Lead terminal are soldering of +350±5℃, 2.0±0.5
Heat Resistance
Second.
Terminal
Mechanical
Strength
Vibration
Drop test
No interference in
operation
Apply the terminal with 9.8N(1kg) strength for 10±1 sec.
The part shall be subjected to a vibration cycle of 10Hz
to 55Hz in a period of 1 minute. Total peak amplitude
shall be 1.52mm(9.3G). The vibration test shall consist of
2 hours per axis in each three axes(X、Y、Z).
The part only shall be dropped from a height of 75cm
onto a 40mm think wooden board 1 times.
No damage and cutting
off
After the test the part
shall meet specifications
without any damage in
appearance and
performance except
SPL. The SPL shall be
in ± 10 dBA compared
with initial one.
(
)
* Wave Soldering profile of lead-free
Temp.(° C)
Max. 10 sec.
250°C
245°C
235°C
200K/s--130°C
---5K/s
100°C
---forced cooling
50°C
0
0
50
100
150
200
250
300
Time(sec)
Recommendable wave soldering condition is as follows.
Note 1: It is requested that wave soldering should be executed after
heat of product goes down to normal temperature.
Note 2: Peak wave temperature of 235°C ~ 250° C maximum of 10 sec. .
F:
MEASUREMENT METHOD
+Vcc
+
VDC
-
BZ
Magnetic
Transducer
G: INSPECTION FIXTURE
Magnetic Transducer
40cm
10cm
Sound Level Meter TES1350A
H:
1 Reel : 320PCS
Carton Box
(10 Inner Box)
Inner Box
(1Layer Reel)
Inner Box
330mmx330mmx30mm
1x320PCS=320PCS
Carton Box
350mmx350mmx370mm
10x320PCS=3,200PCS
I:DRAWING
3.0±0.3
6.4±0.3
WST-1310S-3
(+)
0.5±0.2
Potting
CHK.
DR.
UNIT
SHEET
SCALE
mm
1/1
Land pattern
APP.
4.0±0.3
Note:
Recommended land pattern
3- ? 1
.5
(-)
MODEL NO.
2.0±0.3
3.0±0.3
10.0±0.3
3.5
Tolerance:
MATERIAL PPS
DWG. NO.
PART NO.
Magnetic Transducer
FINISH
TITLE
12.8±0.3
±0.3
12.8±0.3
9.8±0.3
Sound
Emission
Hole
Masking
Label
5
4
3
2
1
NO. DATE ECN. NO.