1.4g
211 N. First Street
Minneapolis, MN. 55401
A:SCOPE
1/4
This specification applies speaker SP-1605
B.SPECIFICATION
■Test condition:
NO
1
2
3
4
5
6
7
8
9
10
11
Item
TEMP:20±10℃
Symbol Unit
Dimension
Resonance
Frequency
Output S.P.L.
Frequency Rang
Distortion
Operating temp
Specification
mm
Ф16×4.7
W
Normal 0.8W
Maximum 1.0W
Ω
ohm
8±15%
F
Hz
900±20%HZ
Input Power
Impedance
Related humidity:50±10%
O
dB
Environmental
Protection
Regulation
1KHz
SPL
@0.8,1.0,1.2
and
87±3(0.1W/10cm) average (0dB SPL=20µPa)
Hz
F0-10K
%
10% Max.
℃
-25~+60
Buzzer & Rattle
Weight
Condition
g
ROHS
OUTPUTS.P.L-10DB
At1.0KHz,0.8W
1.5KHz
in
211 N. First Street
Minneapolis, MN. 55401
C:APPEARANCE DRAWING
2/4
4.7±0.3
38.0±2.0
2.0 1.0
16
3.6
BLUE(-)
UL1571 32AWG
Unit:mm Tolereance:±0.2
D:MEASUREMENT CIRCUIT
Standard test condition of speaker
Power Amplifier
Microphone
318
Speaker
Audio Analyzer
6125y
RED(+)
UL1571 32AWG
211 N. First Street
Minneapolis, MN. 55401
E:ENVIRONMENTAL TEST
NO
1
2
3
3/4
Item
Test conditions
Evaluation standard
High temp. Test
After being placed in a chamber at +60℃ for 16 hours
Low temp. Test
After being placed in a chamber at -25℃ for2hours.
Humidity test
After being placed in a chamber at +40℃ and 90
±5%RH relative humidity for 48 hours.
The part shall be subjected to 5 cycles. One cycle
shall be consist of:
+55℃
Being placed for 6 hours at
+25 ℃ ,buzzer shall be
measured. No obstacle to
be harmful to normal
operation;
damages,
cracks,
rusts,
etc,
Should not be audible at
2.53V sine wave between
F0~10KHz. F0 should meet
initial one, S.P.L. deviation of
unit should be within ±3dB
+25℃
4
-25℃
Temp. cycle
test
0.5
2hrs
hrs
0.5
1hrs
hrs
2hrs
6hrs
F.RELIABILITY YEST
NO
1
Item
Load test
Test conditions
Evaluation standard
0.8W white noise is applied for 24
No obstacle be harmful to normal operation;
damages, cracks, rusts, etc.
Should not be audible at 2.53V sine wave
between F0~10KHz. F0 should meet initial one.
S.P.L. deviation of unit should be within±3dB
hours
TEST CONDITION.
Standard Test Condition: a)Temperature: +5~+35℃ b)Humidity: 45~85%. C)Pressure: 860~1060mbar
Judgement Test Condition a)Temperature:+25±2℃ b)Humidity: 60~70% C) Pressure: 860~1060mbar
211 N. First Street
Minneapolis, MN. 55401
G.MECHANICAL CHARACTERISTICS
NO
1
Item
Terminal strength
Test condition
Evaluation standard
Applied 0.5kg load to terminal for 30sec.
No damage and cutting off.
Speaker shall be measured after being applied vibration
No obstacle to be harmful
to
normal
operation;
damages, cracks, rusts and
distortions.
Should not be audible at
2.53V sine wave between
Fo-10KHz
of amplitude of 1.52mm with 10 to 55Hz band of
2
3
Vibration Test
vibration frequency to each of 3 perpendicular directions
for 2 hours.
Drop Test
4/4
Drop the speakers contained in normal box onto
the board 40mm thick 6 times from the height of
75cm
H .MICRO SPEAKER FREQUENCY RESPONSE CURVE