Data Sheet

Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
Features:
 Choice of four output options in low-cost side-looking package
 Choice of two sensitivity options (OPL560/561/562/563)
 High noise immunity
 Direct TTL/LSTTL CMOS interface
 Data rates to 250 kBaud for all except OPL560 series (200 kBaud)
 Low power consumption
Product Photo Here
Description:
All components in this series include a photodiode, amplifier, voltage regulator, Schmitt trigger and NPN output
transistor on a single silicon chip. OPL560 chips also include a voltage regulator on the chip. All devices in the
series have a Photologic® chip that is encapsulated in a molded plastic side-looking package with an integral lens
(recessed integral lens for OPL535 and OPL536). This packaging provides enhanced optical coupling, combined
with mechanical protection. The hysteresis characteristics of the Schmitt trigger on each device offers high
immunity to noise on input and VCC.
OPL530, OPL531, OPL535 and OPL536 include a 10 K Ω pull-up resistor (RL) from output to VCC. These
components exhibit very stable performance over supply voltages ranging from 4.5 V to 16 V and a wide range of
irradiance levels. OPL550 and OPL551 devices feature TTL/LSTTL compatible logic level output which can drive
up to 8 TTL loads without additional circuitry and medium-speed data rates to 250 kBaud, with typical rise and fall
times of 25 nanoseconds. OPL560, OPL561, OPL562 and OPL563 devices feature TTL/LSTTL compatible logic
level output which can drive up to 10 TTL loads over supply voltages ranging from 4.5 V to 16 V.
OPL530, OPL531, OPL550, OPL551, OPL560, OPL561, OPL562 and OPL563 are mechanically and spectrally
matched to OP140 and OP240 LEDs. OPL535 and OPL536 are mechanically and spectrally matched to OP145
and OP245 series LEDs.
Applications:
 Non-contact reflective
object sensor
 Assembly line automation
 Machine automation
 Machine safety
 End of travel sensor
 Door sensor
Base Part Number
Package
Output Type - with Light
OPL530
External
Lens
Internal 10K - High
Recessed
Lens
Internal 10K - High
OPL531
OPL535
OPL536
Internal 10K - Low
Input Power Range
(mW/cm2) [Min/Max]
-
A
B
0.08/0.40
0.08/0.25
0.20/0.40
Internal 10K - Low
OPL550
Totem Pole - High
0.25/2.4
0.25/1.4
OPL551
Totem Pole - Low
0.25/2.5
0.25/1.5
0.09/0.55
0.09/0.36
0.025/0.23
0.025/0.14 0.07/0.23
OPL560
OPL561
External
Lens
Totem Pole - High
Totem Pole - Low
OPL562
Totem Pole - High
OPL563
Totem Pole - Low
N/A
0.18/0.55
OC = Open Collector Output
RoHS
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com
Issue B 10/14
Page 1 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPL530, OPL550, OPL560 Series
DIMENSIONS ARE IN:
Pin #
Sensor
1
Ground
2
Output
3
VCC
[ MILLIMETERS]
INCHES
OPL535, OPL536 Series
DIMENSIONS ARE IN:
Pin #
Sensor
1
Ground
2
Output
3
VCC
[ MILLIMETERS]
INCHES
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Issue B 10/14
Page 2 of 8
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551, OPL560, OPL561, OPL562, OPL563 (-OC, -OCA, -OCB)
OPL550, OPL550A, OPL551, OPL551A,
OPL560, OPL560A, OPL561, OPL561A, OPL562, OPL562A, OPL563, OPL563A
OPL550/550A/560/560A/562/562A Totem-Pole
OPL530/535/550/560/562 (-OC, -OCA, -OCB) Open-Collector
VCC
VCC
OUT
OUT
GND
OPL 551/551A/561/561A/563/563A/ Inverted Totem-Pole
GND
OPL 531/536/551/561/563 (-OC, -OCA, -OCB) Inverted Open-Collector
VCC
VCC
OUT
OUT
GND
GND
OPL530, OPL530A, OPL530B, OPL531, OPL531A, OPL531B
OPL535, OPL535A, OPL535B, OPL536, OPL536A, OPL536B
OPL530/530A/530B, OPL535/535A/535B 10K Pull-Up
OPL531/531A/531B, OPL536/536A/536B Inverted 10K Pull-Up
VCC
VCC
OUT
OUT
GND
GND
VCC
VCC
OUT
OUT
GND
GND
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com
Issue B 10/14
Page 3 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
Absolute Maximum Ratings (TA=25°C unless otherwise noted)
Input Diode
Supply Voltage (VCC)
OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536, OPL536-OC,
OPL550, OPL551
OPL560, OPL561, OPL562, OPL563
Operating Temperature Range
18 V
10 V
18 V
-40° C to + 85° C
Storage Temperature Range
-40° C to + 100° C
Lead Soldering Temperature [1/16 inch (1.6mm) from the case for 5 sec. with soldering iron]
260°C
Sourcing Current
OPL560, OPL561, OPL562, OPL563
10 mA
Power Dissipation
OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536, OPL536-OC
OPL550, OPL551, OPL560, OPL561, OPL562, OPL563
90 mW
200 mW(2)
Sinking Current
OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536, OPL536-OC
OPL550, OPL551
OPL560, OPL561, OPL562, OPL563
50 mA
50 mA
Voltage at Output Lead (4)
OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536, OPL536-OC
OPL550-OC, OPL551-OC
OPL560-OC, OPL561-OC, OPL562-OC, OPL563-OC
35 V
35 V
35 V
Duration of Output Short to VCC or Ground
OP550, OP551
1 second
Duration of Output Short to VCC
OPL550-OC, OPL551-OC
OPL560, OPL561, OPL562, OPL563, OPL560-OC, OPL561-OC, OPL562-OC, OPL563-OC
1 second
1 second
Low Level Output Current
OPL550, OPL551 Series
16 mA
High Level Output Current
OPL550, OPL551 Series
1 mA
Irradiance
OPL550, OPL551 Series
OPL560, OPL560-OC, OPL561, OPL561-OC
OPL562, OPL562-OC, OPL563, OPL563-OC
10 mW/cm2
9 mW/cm
3 mW/cm2
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 KΩ.
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Issue B 10/14
Page 4 of 8
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL
PARAMETER
MIN
TYP MAX
UNITS
TEST CONDITIONS
Operating Supply Voltage
VCC
OPL530, OPL530-OC, OPL531, OPL531-OC
OPL535, OPL535-OC, OPL536, OPL536-OC,
OPL560, OPL561 Series
4.5
-
16
V
-
OPL550, OPL551 Series
4.5
-
5.5
V
-
-
-
2
V
f = DC to 50 MHz
-
2
-
V
VCC = 5 V DC, f = DC to 50 MHz
OPL530, OPL530-OC, OPL531, OPL531-OC
OPL535, OPL535-OC, OPL536, OPL536-OC
-
2.7
5
mA
EE = 0 or 1 mW/cm2
OPL550, OPL551 Series
-
8
15
mA
EE = 0 or 3 mW/cm2, VCC = 5.5 V
OPL560, OPL561 Series
-
8
12
mA
EE = 0 or 1 mW/cm2
OPL530, OPL530-OC, OPL531, OPL531-OC
OPL535, OPL535-OC, OPL536, OPL536-OC
0.08
-
0.40
mW/cm2 TA = 25° C
OPL530A, OPL530-OCA, OPL531A, OPL531-OCA
OPL535A, OPL535-OCA, OPL536A, OPL536-OCA
0.08
-
0.25
mW/cm2 TA = 25° C
OPL530B, OPL530-OCB, OPL531B, OPL531-OCB
OPL535B, OPL535-OCB, OPL536B, OPL536-OCB
0.12
-
0.40
mW/cm2 TA = 25° C
.25
.25
-
2.4
1.4
mW/cm2 VCC = 5 V, TA = 25° C
mW/cm2 VCC = 5 V, TA = 25° C
OP530, OP531 Series
1.05
1.3
1.6
-
-
OP535, OP536 Series
1.05
1.2
1.5
-
-
OPL550, OPL551 Series
1.50
2
2.5
-
-
OPL560, OPL561 Series
1.20 1.55
2
-
-
Peak-to-Peak VCC Ripple Necessary to Cause
False Triggering of Output
OPL530, OPL530-OC, OPL531, OPL531-OC
OPL535, OPL535-OC, OPL536, OPL536-OC
OPL560, OPL561 Series
OPL550, OPL551 Series
Supply Current(4)
ICC
Positive-Going Threshold Irradiance(3)
EeT(+)
OPL550, OPL550-OC, OPL551, OPL551-OC
OPL550A, OPL550-OCA, OPL551, OPL551-OCA
Hysteresis Ratio
EeT(+)/EeT(-)
∆Eet(+)
(∆T)
Temperature Co-efficient
OPL530, OPL530-OC, OPL531, OPL531-OC
OPL535, OPL535-OC, OPL536, OPL536-OC
-
-0.6
-
%/°C
>0°C
-
-1.6
-
%/°C
<0°C
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 KΩ.
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com
Issue B 10/14
Page 5 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL
PARAMETER
MIN
TYP MAX
OPL550
2.4
3.3
-
V
OPL551
2.4
3.3
-
V
OPL560
VCC -2.1
-
-
V
VCC = 4.5 V, IOH = -800 µa,
EE = 3 mW/cm2
VCC = 4.5 V, IOH = -800 µa,
EE = 0
IOH = -1 µA, EE = 1 mW/cm2
OPL561
VCC -2.1
-
-
V
IOH = -1 µA, EE = 0
OPL530, OPL530-OC, OPL535, OPL535-OC
-
0.2
0.4
V
IOL = 16 mA, EE = 0
OPL531, OPL531-OC, OPL536, OPL536-OC
-
0.2
0.4
V
IOL = 16 mA, EE = 1 mW/cm2
OPL550
-
0.25
0.4
V
OPL551
-
0.25
0.4
V
OPL560, OPL560-OC
-
-
.4
V
VCC = 4.5 V, IOL = 12.8 mA,
EE = 0
VCC = 4.5 V, IOL = 12.8 mA,
EE = 3 mW/cm2
IOL = 16 mA, EE = 0
OPL561, OPL561-OC
-
-
.4
V
IOL = 16 mA, EE = 1 mW/cm2
OPL550
-20
-55
-100
mA
OPL551
-20
-55
-100
mA
VCC = 5.5 V, Output = GND,
EE = 3 mW/cm2
VCC = 5.5 V, Output = GND,
EE = 0
OPL531, OPL531-OC, OPL536, OPL536-OC
-
0.1
10
µA
VOH = 30 V, EE = 0
OPL535, OPL535-OC, OPL530, OPL530-OC
-
0.1
10
µA
VOH = 30 V, EE = 1 mW/cm2
OPL550-OC
-
1
100
µA
OPL551-OC
-
1
100
µA
OPL560-OC
-
-
100
µA
VCC = 4.5 V, VOH = 30 V,
EE = 3 mW/cm2
VCC = 4.5 V, VOH = 30 V,
EE = 0
VOH = 30 V, EE = 1 mW/cm2
OPL561-OC
-
-
100
µA
VOH = 30 V, EE = 0
Operating Supply Voltage
VOH
Low Level Output Voltage
VOL
Short Circuit Output Current
IOS
High Level Output Current(4)
IOH
UNITS
TEST CONDITIONS
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 KΩ.
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Issue B 10/14
Page 6 of 8
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL
PARAMETER
MIN
TYP MAX
UNITS
Output Rise Time
OPL530, OPL531, OPL535, OPL536
-
1.5
-
µs
EE = 0 or 1 mW/cm2, CL = 50 pF
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
-
50
-
ns
OPL550, OPL551
-
25
70
ns
OPL550-OC, OPL551-OC
-
25
70
ns
OPL560, OPL561
-
-
70
ns
OPL560-OC, OPL561-OC
-
-
100
µs
EE = 0 or 1 mW/cm2, RL = 300 Ω to
5 V, CL = 50 Pf
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, f = 10 kHz, DC = 50%
RL = 8 TTL loads
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, f = 10 kHz, DC = 50%,
RL = 360 Ω
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz, DC = 50%,
RL = 360 Ω
-
-
-
tr
Output Rise Time
OPL530, OPL531, OPL535, OPL536
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
µs
-
-
ns
EE = 0 or 1 mW/cm2, CL = 50 pF
EE = 0 or 1 mW/cm2, RL = 300 Ω to
5 V, CL = 50 pF
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 8 TTL loads,
f = 10 kHz, DC = 50%
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 8 TTL loads,
f = 10 kHz, DC = 50%
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
OPL550-OC, OPL551-OC
-
25
70
ns
OPL560-OC, OPL561-OC
-
-
70
ns
OPL560, OPL561
-
-
70
ns
-
-
100
ns
-
20
-
ns
EE = 0 or 1 mW/cm2, CL = 50 Pf
-
20
-
ns
-
25
70
ns
-
-
70
ns
-
-
100
ns
EE = 0 or 1 mW/cm2, RL = 300 Ω to
5 V, CL = 50 pF
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 360 Ω, f = 10 kHz,
DC = 50%
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
TA = 25° C, EE = 0 or 1 mW/cm2,
f = 10 kHz
tr
OPL560-OC, OPL561-OC
Output Fall Time
OPL530, OPL531, OPL535, OPL536
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
tf
TEST CONDITIONS
OPL550-OC, OPL551-OC
OPL560, OPL561
OPL560-OC, OPL561-OC
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 KΩ.
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com
Issue B 10/14
Page 7 of 8
Photologic Sensor
OPL530, OPL531, OPL535, OPL536, OPL550, OPL551,
OPL560, OPL561, OPL562, OPL563
Electrical Characteristics (TA = 25°C unless otherwise noted)
SYMBOL
PARAMETER
MIN
TYP MAX
UNITS
TEST CONDITIONS
EE = 0 or 1 mW/cm2, RL = 300 Ω to
5 V, CL = 50 pF
EE = 0 or 1 mW/cm2, RL = 300 Ω to
5 V, CL = 50 pF
VCC = 5 V, TA = 25° C,
EE = 0 or 3 mW/cm2, RL = 8 TTL
loads, f = 10 kHz, DC = 50%
Propagation Delay
tpEeT(+)
OPL530, OPL531, OPL535, OPL536
-
1.0
-
µs
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
-
1.0
-
µs
OPL550-OC, OPL551-OC
-
2.5
5
µs
OPL530, OPL531, OPL535, OPL536,
OPL530-OC, OPL531-OC, OPL535-OC,
OPL536-OC
-
3.0
-
µs
EE= 0 or 1 mW/cm2, RL = 300 Ω to
5V, CL = 50 pF
OPL550-OC, OPL551-OC
-
2.5
5
µs
VCC = 5 V, TA = 25° C, EE = 0 or 3
mW/cm2, RL = 360 Ω, f = 10 kHz,
DC = 50%
OPL560, OPL561
-
5
-
µs
DC = 50%, RL = 10 TTL Loads
OP560-OC, OPL561-OC
-
5
-
µs
DC = 50%, RL = 300 Ω
Propagation Delay
tpEeT(-)
Propagation Delay (Low-High/High-Low)
tPLH, TPHL
Notes:
(1) RMA flux is recommended. Duration can be extended to 10 sec. max. when flow soldering. For OPL530, OPL530-OC,
OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and OPL536-OC, a maximum of 20 grams force may be applied to leads
while at soldering temperatures.
(2) Derate linearly 2.67 mW/°C above 70° C for OPL530, OPL530-OC, OPL531, OPL531-OC, OPL535, OPL535-OC, OPL536 and
OPL536-OC. Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and
OPL563 series.
(3) Irradiance measurements are made with λi = 935 nm.
(4) This applies to OC versions only. For ICC on pull-up versions, add VCC/10 KΩ.
OPTEK reserves the right to make changes at any time in order to improve design and to supply the best product possible.
Issue B 10/14
Page 8 of 8
OPTEK Technology Inc. — 1645 Wallace Drive, Carrollton, Texas 75006
Phone: (972) 323-2200 or (800) 341-4747
FAX: (972) 323-2396 [email protected] www.optekinc.com