OPI1290-040

Sensing and Control
Fiber Optic Isolator - Photologic® Sensor
OPI1290 Series
Features:
• Opaque plas c housings
• High noise immunity
• IR LED with Phototransistor Output
• 0.05” (1.27 mm) lead spacing
• Data Transfer through plas c fiber op c cable
• Isola on voltage 15 KV (OPI1290-032), Longer versions higher
DescripƟon:
Each OPI1290 consists of a IR LED and a Photologic® Totem-Pole output sensor, which are housed in separate opaque
molded plas c housings and coupled by plas c fiber op c cable. The heavy-duty opaque housing shields the op cal signal
from dust, making this series of devices ideal for dust contaminated environments.
The OPI1290 series are designed for applica ons that require high voltage isola on between input and output or signal
communica on over short distances. Depending on the length of the fiber op c cable, the emi er does not have to be
op cally in-line with the sensor. The isola on voltage is greater than 10 K volts per inch (Isola on distance between
components) for all versions of the OPI1290.
Custom electrical, wire and cabling and connectors are available. Contact your local representa ve or OPTEK for more
informa on.
Ordering InformaƟon
ApplicaƟons:
•
•
•
•
•
Requiring High Voltage isola on between
input and output
Electrical isola on in dirty environments
Industrial equipment
Medical equipment
Office equipment
Device Length
±2mm
Part
Number
IsolaƟon Distance
±2mm
Device
Length ±2mm
OPI1290-018
0.86” [22 mm]
1.26” [32.0 mm]
OPI1290-026
1.18” [30 mm]
1.57” [40.0 mm]
OPI1290-032
1.42” [36 mm]
1.80” [45.8 mm]
OPI1290-040
1.73” [44 mm]
2.12” [53.8 mm]
OPI1290-066
2.76” [70 mm]
3.15” [80.0 mm]
OPI1290-080
3.31” [84 mm]
3.69” [93.8 mm]
Isolation
Distance
LED Peak
Lead Length
Wavelength
0.45”
[11.4 mm]
890 nm
Pin #
LED
1
Anode
2
Cathode
3
VCC
4
Output
5
Ground
VCC
An
Output
RoHS
General Note
TT Electronics reserves the right to make changes in product specificaƟon
without noƟce or liability. All informaƟon is subject to TT Electronics’ own data
and is considered accurate at Ɵme of going to print.
© TT electronics plc
Cathode
Ground
1645 Wallace Drive, Carrollton, TX 75006|Ph: +1 972 323 2200
www.optekinc.com | www. electronics.com
Issue D
06/2015
Page 1
Sensing and Control
Fiber Optic Isolator - Photologic® Sensor
OPI1290 Series
Absolute Maximum RaƟngs (TA=25°C unless otherwise noted)
Storage Temperature Range (note 3)
-40o C to +80o C
Opera ng Temperature Range (note 3)
-20° C to +75° C
Lead Soldering Temperature [1/16 inch (1.6 mm) from case for 5 seconds with soldering iron]
260° C(1)
Power Dissipa on (2)
100 mW
Electrical CharacterisƟcs (TA = 25°C unless otherwise noted)
SYMBOL
PARAMETER
MIN
TYP
MAX
UNITS
TEST CONDITIONS
1.2
-
2.3
V
IF = 20 mA
-
-
80
µA
VR = 3.0 V
LED (See OP240 for addi onal informa on)
VF
On-State Collector Current
IR
Collector-Dark Current
Photologic® Sensor (See OP550 for addi onal informa on)
SYMBOL
PARAMETER
MIN
TYP
MAX
UNITS
TEST CONDITIONS
4.5
-
16
V
-
Peak-to-Peak VCC Ripple Necessary to Cause
False Triggering of Output
-
-
2
V
VCC = 5 V DC, f = DC to 50 MHz
Supply Current(4)
-
8
15
mA
EE = 0 or 3 mW/cm2, VCC = 5.5 V
Posi ve-Going Threshold Irradiance(2)
.25
-
2.4
Hysteresis Ra o
1.50
2
2.5
-
Opera ng Supply Voltage
VCC
ICC
EeT(+)
EeT(+)/EeT(-)
mW/cm2 VCC = 5 V, TA = 25° C
-
VOH
Opera ng Supply Voltage
2.1
-
-
V
IOH = -1 µA, EE = 1 mW/cm2
VOL
Low Level Output Voltage
-
0.25
0.4
V
VCC = 4.5 V, IOL = 12.8 mA, EE = 0
IOS
Short Circuit Output Current
-20
-55
-100
mA
VCC = 5.5 V, Output = GND,
EE = 3 mW/cm2
IOH
High Level Output Current(2)
-
1
100
µA
VCC = 4.5 V, VOH = 30 V,
EE = 3 mW/cm2
TR & TF
Output Rise & Fall Time
-
25
70
ns
VCC = 5 V, TA = 25° C, EE = 0 or 3 mW/
cm2, f = 10 kHz, DC = 50%
RL = 8 TTL loads
tpEeT(+)
Propaga on Delay Posi ve–Going
-
2.5
5.0
µs
VCC = 5 V, TA = 25° C,
EE = 0 or 3 mW/cm2, RL = 8 TTL loads, f
= 10 kHz, DC = 50%
tpEeT(-)
Propaga on Delay Nega ve–Going
-
2.5
5.0
µs
VCC = 5 V, TA = 25° C, EE = 0 or 3 mW/
cm2, RL = 360 Ω, f = 10 kHz, DC = 50%
tPLH, TPHL
Propaga on Delay (Low-High/High-Low)
-
5.0
-
µs
DC = 50%, RL = 10 TTL Loads
Notes:
(1)
(2)
(3)
Derate linearly 2.5 mW/° C above 25° C for all devices in the OPL550, OPL551, OPL560, OPL561, OPL562 and OPL563 series.
Irradiance measurements are made with λi = 935 nm.
Storage and Opera ng temperature values are based on the plas c op cal interface temperature ra ngs. Please reference UL1577 and UL file AVLVZ.E89328
General Note
TT Electronics reserves the right to make changes in product specificaƟon
without noƟce or liability. All informaƟon is subject to TT Electronics’ own data
© TT electronics plc
1645 Wallace Drive, Carrollton, TX 75006|Ph: +1 972 323 2200
www.optekinc.com | www. electronics.com
Issue D
06/2015
Page 2