short form SACB

SACB (5 00W) Series
LOW CAPACITANCE TRANSIENT VOLTAGE SUPPRESSOR
STAND-OFF VOLTAGE5.0 - 50 Volts
500 watt Peak Pulse Power
" * " 标注为常用型号
" * " Stand for commonly used models
SACB
PART
NUMBER
* SACB5.0
SACB6.0
SACB7.0
SACB8.0
SACB8.5
SACB10
SACB12
SACB15
SACB18
SACB22
SACB26
SACB30
SACB36
SACB45
SACB50
Marking
Code
SKE
SKG
SKM
SKR
SKT
SKX
SLE
SLM
SLT
SLX
SME
SMK
SMP
SMV
SMZ
MINIMUM
STANDBREAKDOWN
OFF
VOLTAGE
VOLTAGE
AT I T=1.0mA
(NOTE1)
V WM
V(BR)
(VOLTS)
(VOLTS)
5.0
6.0
7.0
8.0
8.5
10.0
12.0
15.0
18.0
22.0
26.0
30.0
36.0
45.0
50.0
7.6
7.9
8.3
8.9
9.44
11.10
13.30
16.70
20.00
24.40
28.90
33.30
40.00
50.00
55.50
MAXIMUM
REVERSE
LEAKAGE
AT V WM
I R(uA)
300
300
300
100
50
5
5
5
5
5
5
5
5
5
5
MAXIMUM
MAXIMUM
MAXIMUM
JUNCTION
CLAMPING PEAK PULSE
CURRENT
CAPACITANCE
VOLTAGE
AT 0 VOLTS
AT Ipp=5.0A PER FIG.3
Ipp (AMPS)
(pF)
V C (V)
10.0
11.2
12.6
13.4
14.0
16.3
19.0
23.6
28.8
35.4
42.3
48.6
60.0
77.0
88.0
44.0
41.0
38.0
36.0
34.0
29.0
25.0
20.0
15.0
14.0
11.1
10.0
8.6
6.8
5.8
45
45
45
45
45
45
45
45
45
45
45
45
45
45
45
WORKING
INVERSE
BLOCKING
VOLTAGE
V WIB
(VOLTS)
75
75
75
75
75
75
75
75
75
75
75
75
75
150
150
INVERSE
PEAK
BLOCKING INVERSE
LEAKAGE BLOCKING
CURRENT VOLTAGE
V WIB
V PIB
IIB(mA)
(VOLTS)
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
100
100
100
100
100
100
100
100
100
100
100
100
100
200
200
REV.2015.02.01
01 | www.spsemi.cn
SACB(5 00W) Series
LOW CAPACITANCE TRANSIENT VOLTAGE SUPPRESSOR
STAND-OFF VOLTAGE5.0 - 50 Volts
500 watt Peak Pulse Power
FEATURES
DO-214AA (SMB J-Bend)
◎ For surface mounted applications in order to optimize board space
◎ Glass passivated junction
Cathode Band
0.155 (3.94)
0.130 (3.30)
0.086 (2.20)
0.073 (1.85)
0.180 (4.57)
0.160 (4.06)
0.012 (0.305)
0.006 (0.152)
0.098 (2.5)
0.083 (2.1)
0.012 (0.3) MAX.
0.060 (1.52)
0.030 (0.76)
◎ 500W Peak Pulse Power capability with a 10/1000us waveform,repetition
rate (duty cycle): 0.01%
◎ Excellent clamping capability
◎ Low incremental surge resistance
◎ Fast response time: typically less than 1.0ps from 0 Volts to V(BR)
for unidirectional types
◎ Ideal for data line applications
◎ High temperature soldering guaranteed: 260°C/10 seconds,0.375"(9.5mm)
lead length,5lbs., (2.3kg) tension
0.220 (5.59)
0.205 (5.21)
Dimensions in inches and(millimeters)
Transient
Voltage
Suppressor
Diode
Schemati
MECHANICAL DATA
Case:JEDEC DO-214AA. Molded plastic over glass passivated junction
Terminal: Solder plated, solderable per MIL-STD-750, Method 2026
Polarity:The band denotes TVS cathode
Standard Packaging:12mm tape(EIA STD RS-481)
Weight: 0.003ounce, 0.093gram
MAXIMUM RATINGS AND CHARACTERISTICS
Ratings at 25℃ ambient temperature unless otherwise specified.
RATING
Peak Pulse Power Dissipation with a 10/1000µs waveform (Note 1)
Steady State Power Dissipation at TL= 75°C with lead lengths or 0.375"
(9.5mm)
Peak Pulse Power Surge Current with a 10/1000 µS waveform (Note
1.FIG.3)
Operating junction and Storage Temperature Range
SYMBOL VALUE
Minimum
PppM
500
UNITS
Watts
PM(AV)
3
Watts
IPPM
SEE
TABLE 1
Amps
-55 to
+175
°C
TJ , TSTG
Note:
1.Non-repetitive current pulse , per Fig. 3 and derated above TA = 25℃ per Fig. 2 .
REV.2015.02.01
02 | www.spsemi.cn
SACB(500W) Series
LOW CAPACITANCE TRANSIENT VOLTAGE SUPPRESSORS
Ratings and
Characteristic Curves(TA=25℃ unless otherwise noted)
100
Pig.1 - Peak Pulse Power Rating Curve
Fig.2-Power Derating Curve
100
Non-repetitive Pulse
Waveform shown in Fig. 3
Average Power
Percentage of Rated Power(%)
IPPM-Peak Pulse Power (kW)
30
TA=25°C
10
Impulse
Exponential
Decay
PPK".5"
1
td
PPK
Half Sine
td
td=7tp
PPK
td
Square
Current Waveforms
1.0s
10s
100s
1.0ms
50
37.5
25
12.5
25
50
75
100
125
150
175
TL Lead Temperature (°C)
Fig.3 - Pulse Waveform
Fig. 4 - AC Line Protection Application
150
TJ = 25°C
tr = 10µsec.
IPPM - Peak Pulse Current,% IRSM
Peak Power
(single pulse)
62.5
0
10ms
td - Pulse Width (sec.)
Pulse Width (t d)
is defined as the point
where the peak current
decays to 50% of IPPM
Peak Value
IPPM
100
75
0
0.1
0.1s
87.5
Low Capacitance
TVS
Half Value- IPPM
2
50
10/1000µsec.Waveform
as defined by R.E.A.
td
0
0
1.0
2.0
3.0
t - Time(ms)
REV.2015.02.01
3.0
4.0
4.0
Application Note: Device must be used
with two units in parallel,opposite in polarity
as shown in circuit for AC signal line
protection.
03 | www.spsemi.cn