GENERAL DESCRIPTION
FEATURES
SM3015 is a multi-function Fan Controller CMOS
IC that can be applied to a variety of consumer
products. It has an elastic function like MCU but
does not need programming, user can just write a
MASK form.
SM3015 has three or four wind modes; normal,
rhythm and sleep-rhythm wind or normal, rhythm,
sleep-normal and sleep-rhythm, the operation
pattern of rhythm and sleep modes can be set by
user.
Many kinds of timer setting and two swing head
control that include micro-swing output can be
chosen by user to tune the swing head angle.
Memory or non-memory function is available; the
Speed, Mode, Swing functions will operate as last
state in memory type.
Supports two-bit customer codes to distinguish
different models.
* High performance CMOS technology.
* Rhythm wind or Normal wind for SLEEP
mode can be chosen.
* Two to three-wind grade control in wind
modes.
* Memory start-up function option.
* Many types of timer setting on three or four
steps and ladder adder or non-ladder
adder.
* Two swing head control, micro-swing output
can be chosen by MASK option.
* SPEED or ON/OFF key can enable fan
controller.
* 16 or 32 patterns per cycle of rhythm/sleep
mode, each pattern has 2.5 sec.
* Panel control or pair with SM5021B for an
infrared Remote Fan Controller.
* 16/18/20/22 pin plastic DIP package.
* 32.768KHz/455KHz oscillator option.
APPLICATIONS
* Electronic Fan
* Heater Fan
* Air-Cleaner
* Dehumidifier
* Humidifier
* Kitchen Exhaust
* Dish Dryer
* Wall Fan
PIN ASSIGNMENTS (TOP VIEW)
LIGHT
DI
OFF(ON/OFF)
TIMER
SPEED
MODE
COM1
COM2
COM3
SWING1
SWING2
1
2
3
4
5
6
7
8
9
10
11
22
21
20
19
18
17
16
15
14
13
12
LTO
LIGHT
VSS
DI
OSC1
OFF(ON/OFF)
OSC2
TIMER
BUZ
SPEED
VDD
MODE
LOW
COM1
MEDIUM
COM2
STRONG
COM3
SHO1
SWING1
SHO2
NC
SM3015A 16/18/20/22PIN
Page 2
1
2
3
4
5
6
7
8
9
10
11
22
21
20
19
18
17
16
15
14
13
12
LTO
VSS
OSC1
OSC2
BUZ
VDD
LOW
MEDIUM
STRONG
SHO1
SHO2
SM3015B 16/18/20/22PIN
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
PANEL DISPLAY
S
2HR
M
1HR
SLP-RHY (SWING FUNCTION)
SLP-NOR
RHY
Right Left Up Down
1/2HR
NOR
4HR
L
OFF SPEED
ON/OFF
TIMER
SHO1
MODE
(SWING FUNCTION)
SHO1
SHO2
SW1
SW2
TUNER1 TUNER2
SHO2
LIGHT
SWING
SM3015A TYPE
* Note: "
SM3015B TYPE
" Functions can be chosen by MASK or bonding option.
BLOCK DIAGRAM
VDD
BUZ
VSS
BUZZER
DI
REMOTE CONTROL
DECODER
OSC1
OSCILLATOR
OSC2
OFF
TIMER
MODE
COM1
STRONG
FAN FUNCTIONS CONTROL
SPEED
SPEED/MODE/TIMER/MEMORY
KEY INPUT
SPEED
LED OUTPUT
OUTPUT
SCAN_SIGNAL
DRIVER
ROM
COM2
MEDIUM
LOW
TIMER
COM3
SWING1
SWING2
LIGHT
SWING/LIGH
T CONTROL
SYSTEM TIMING GENERATOR
ZERO_CROSS
SHO1 SHO2 LTO
Page 3
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
PIN DESCRIPTIONS
No.
Pin Name
I/O
Function
1
LIGHT
I
Light control input
2
DI
I
Remote control input
3
ON_OFF/OFF
I/O
On-Off or Off function control input
4
TIMER
I/O
Timer setting input
5
SPEED
I/O
Wind grade selection input
6
MODE
I/O
Wind mode selection input
7
COM1
O
LED scanning common pin / Customer code
8
COM2
O
LED scanning common pin / Customer code
9
COM3
O
LED scanning common pin
10
SWING1
I
Swing head control input / Customer code
11
SWING2
I
Swing head control input
12
SHO2
O
Swing head / tuner pulse output
13
SHO1
O
Swing head / tuner pulse output
14
STRONG
O
Wind speed control output
15
MEDIUM
O
Wind speed control output
16
LOW
O
Wind speed control output
17
VDD
POWER
Positive power supply
18
BUZ
O
Trigger output to drive piezo
19
OSC2
O
Crystal output
20
OSC1
I
Crystal input
21
VSS
POWER
Negative power supply (Substrate)
22
LTO
O
Light control output
Page 4
V.4.0 Dec 21,2005
SAMHOP Microelectronics Corp.
SM3015
REMOTE FAN MCU
FUNCTION DESCRIPTION
SM3015 has two control types : panel keypad and infrared remote control.
There are four to eight control signal operations :
* Start-up by SPEED key
a. function turn off (OFF key)
b. wind mode select (MODE key)
c. start-up function and wind speed select (SPEED key)
d. timer setting (TIMER key)
e. swing head or tuner for swing angle (SW1 and SW2 key)
f. lighting control (LIGHT key)
* Start-up by ON/OFF key
a. function control (ON/OFF key)
b. wind mode select (MODE key)
c. wind speed select (SPEED key)
d. timer setting (TIMER key)
e. swing head or tuner for swing angle (SW1 and SW2 key)
f. lighting control (LIGHT key)
All functions can be planned by user like an MCU for more product application.
Only SPEED or ON/OFF key can enable the fan controller, except for the light control. Wind mode, timer and
swing head inputs can not be accepted when fan is not activated. The fan controller will be turned off by timer
and OFF (ON/OFF) key inputs.
When more than one key are pressed, controller will not accept the multi-key's control signal, if the panel keys
are pressed more than six seconds, controller will generate a " BI-BI-BI-BI" warning sound. When fan is
enabled by SPEED or ON/OFF key, the initial state of fan controller is as follows:
* Memory function available
If Fan controller is OFF on sleep mode, all memory functions will be returned to the LAST TURN ON STATE.
a. Grade as last state but with starting medium wind for three seconds (MASK option)
b. The wind mode as last state except sleep mode
c. Swing function as last state
d. Timer setting off
e. Light is independent
* Non-memory function (Bonding option)
a. Grade is low wind function but with starting medium wind for three seconds (MASK option)
b. Normal wind mode operation
c. Timer setting and swing head off
d. Light is independent
Page 5
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
A. OFF KEY
When fan controller is on, press the OFF key on panel or remote control handset, fan functions will be
turned off except light output.
* BONDING OPTION : ON/OFF KEY
When fan controller functions are on, press ON/OFF key on panel or remote control handset, fan functions
will be turned off; if functions are off, press the key to turn on fan functions. Light output is independent.
B. SPEED KEY
When fan control is off, press SPEED key on panel or remote control handset, fan is turned on; when
memory function is available, the wind grade will operate as last state. Both conditions have three seconds
starting wind. Press the SPEED key again, the wind will be changed as follows :
OFF
LOW
MEDIUM
STRONG
SPEED key used
Pulse is put into OFF pin
* BONDING OPTION: SPEED KEY ONLY
If fan controller is off, SPEED key cannot be used, must press ON/OFF key to turn on the fan controller. When
fan controller is on, press SPEED key on panel or remote control handset and wind grade changes as follows:
OFF
LOW
MEDIUM
STRONG
SPEED key used
Pulse is put into ON/OFF pin
Page 6
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
* MASK OPTION: WIND GRADE
a. There are two types of wind grade control function to choose. If fan controller is on,
press SPEED key on panel or remote control handset, wind grade changes as follows:
1. OFF
LOW
MEDIUM
2. OFF
LOW
STRONG
STRONG
SPEED key used
SPEED key or ON/OFF key used
b. Memory or non-memory function can be chosen.
C. MODE KEY
SM3015 has four types of wind mode: normal, rhythm, sleep + rhythm, and sleep + normal these can be chosen
by mode key setting. Memory function is available except on sleep mode.
1. OFF
NOR
RHY
SLP-RHY
: Press MODE key: normal setting
: Pulse is put into OFF or ON/OFF pin
: SPEED or ON/OFF key used
Page 7
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
* MASK OPTION:
a. Memory or non-memory function can be chosen.
b. There are five kinds of wind mode operation.
OFF
OFF
NOR
NOR
RHY
OFF
NOR
RHY
SLP
(RHY)
OFF
NOR
RHY
SLP
(NOR)
OFF
NOR
RHY
SLP
(NOR)
SLP
(RHY)
Press MODE key: normal setting
Pulse is put into OFF or ON/OFF pin
SPEED or ON/OFF key used
D. LIGHTING CONTROL KEY
The LI GH T k ey is inde pend ent and the out put is t oggle fu nctio n. Whe n th e LI G HT key is
pressed on panel or remote control handset, operation is as follows :
OFF
Light output key
Press LIGHT key
* MASK OPTION:
Fan controller is off, LIGHT key cannot be used.
Page 8
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
E. TIMER KEY SETTING
SM3015 has many types of timer setting, mode A is ladder-adder and mode B is non-ladder adder for three or
four steps. Timer key will not activate when fan controller is off. These types of timer may be chosen by
bonding option.
MODE A: Timer with accumulation
Timer Pulse No.
Four-steps Type
A*1
A*2
A*3
A*4
Three-steps Type
A*1
A*2
A*3
D
Three-steps Type
A
B
C
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
MODE B: Timer with non-accumulation
Timer Pulse No.
Four-steps Type
A
B
C
1
2
3
4
LED display
* MASK OPTION:
A,B time base are common multiple by 30 minute ascending, and each number can be
set by user.
Page 9
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
F. SWING KEY:SWING1 AND SWING2
The swing key will not activate when fan controller is off. Memory function is available, the swing output will
operate as last state when press SPEED or ON/OFF key, except tuner function using.
A Type :
SM3015A has two keys of SW1 and SW2 to control the outputs of SHO1 and SHO2 (toggle function).
OFF
OFF
SHO1 enable
(Right / Left)
The SW1 key pressed
SHO2 enable
(Up /Down)
The SW2 key pressed
When SHO1 and SHO2 outputs enable together, the swing head has 3D function.
B Type :
SM3015B/D has only one SWING key to control the outputs of SHO1 and SHO2.
OFF
SHO1(Right & Left)
SHO2(Up & Down)
3D ∞
:The SWING key pressed
* MASK OPTION :
a. SHO1 and SHO2 output can be enabled when fan controller is off.
b. SHO1 and SHO2 output functions can be chosen as a continuous outputs respectively like a
micro-swing switch to tune the swing angle.
Page 10
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
G. MEMORY FUNCTION
Memory of speed, mode(except sleep mode) and swing functions can be set independently. Memory function
can be cancelled by Bonding option. When memory function is available, wind speed mode and swing functions
will operate as last state; if last state is sleep mode, press SPEED or ON/OFF key enable fan controller while
memory functions(Speed/Mode/Swing) will be returned to the last state before sleep mode operation.
H. STARTING WIND
Memory or non-memory type, fan controller starts with three seconds starting wind.
I. CUSTOMER CODE
SM3015 provide two-bit customer code to distinguish different product models. There are four
types, that can be set by diode.
a. Set code bit to "0", connect diode to COM1/COM2 and SWING/SW1 terminal
b. Set code bit to "1", open the circuit.
SWING/SW1 PIN
D1
D2
0
0
0
1
1
0
1
1
D2
COM1
PIN
Page 11
D1
COM2
PIN
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
J. BUZZER
Any key pressed on panel or fan controller receives a control signal from remote control handset, will generate a
4KHz 50% duty cycle pulse train on buzzer output pin.
a. When FAN is from stop mode to start mode (press SPEED or ON_OFF key)
Buzzer output will generate a "BI-BI" sound.
a
b
c
b. When FAN is from start mode to stop mode (press OFF/ON_OFF key)
Buzzer output will generate a long "BI" sound.
d
c. When FAN is operating (press any key other than OFF/ON_OFF key)
Buzzer output will generate a "BI" sound.
e
When
a = c = e = 62ms
b = 124ms
d = 250ms
* MASK OPTION
Fan controller will generate a 150ms duration 2KHz 50% duty cycle pulse train on BUZ output
pin.
Page 12
V.4.0 Dec 21,2005
SAMHOP Microelectronics Corp.
SM3015
REMOTE FAN MCU
K-1. RHYTHM WIND FUNCTION (DEFAULT)
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80
STRONG RHYTHM WIND PATTERN
(SEC)
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80
MEDIUM RHYTHM WIND PATTERN
(SEC)
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80
LOW RHYTHM WIND PATTERN
(SEC)
*MASK OPTION:
32 patterns per cycle, each pattern (2.5 seconds) can be set by user.
Page 13
V.4.0 Dec 21,2005
SAMHOP Microelectronics Corp.
SM3015
REMOTE FAN MCU
K-2. RHYTHM WIND FUNCTION (DEFAULT)
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80
STRONG RHYTHM WIND PATTERN
(SEC)
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80
MEDIUM RHYTHM WIND PATTERN
(SEC)
S
M
L
0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 52.5 55 57.5 60 62.5 65 67.5 70 72.5 75 77.5 80
LOW RHYTHM WIND PATTERN
(SEC)
*MASK OPTION:
32 patterns per cycle, each pattern (2.5 seconds) can be set by user.
Page 14
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
L. SLEEP FUNCTION
In sleep mode, wind grade is changed by timing automatically.
S
M
L
Strong
Wind
Medium
Wind
Low Wind
30 min
60 min
Page 15
TIME
V.4.0 Dec 21,2005
SAMHOP Microelectronics Corp.
SM3015
REMOTE FAN MCU
TIMING CONTROL
Speed Key
On/Off Key
t key
Buz
t buz
Low
Medium
3 sec.
Strong
Mode Key
t key
Normal
Rhythm
Sleep
Off Key
On/Off Key
t key
Fan Enable
* NOTE: tbuz see page 12 and tkey see page 6
Page 16
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
DC ELECTRICAL CHARACTERISTICS
Test Conditions
Min.
Limits
Typ.
Max.
3
5
6
V
500
uA
Parameter
Symbol
Supply Voltage
VDD
Stand-by Current
ISB
Input High Level
VIH
Input Low Level
VIL
Sink Current
(OFF,MODE,SPEED
TIMER,SLEEP)
IOL
VOL=+0.7V
10
mA
Source Current
(OFF,MODE,SPEED
TIMER,SLEEP)
IOH
VOH=+4.3V
6
mA
Triac Sink Current
(S,M,L,SW1,
SW2,LIGHT)
IOL
VOL=+0.7V
10
mA
Triac Source Current
(S,M,L,SW1,
SW2,LIGHT)
IOH
VOH=+4.3V
3
mA
Sink Current
(COM1~COM3)
IOL
VOL=+0.7V
35
mA
Source Current
(COM1~COM3)
IOH
VOH=+4.3V
3
mA
Sink Current
(BUZ)
IOL
VOL=+0.7V
6
mA
Source Current
(BUZ)
IOH
VOH=+4.3V
3
mA
Pull-high Resister
(Input pin)
RPH
400
K OHM
OSC stop
all output pins open
all input fixed to VDD
3.2
Unit
V
1.8
V
*NOTE: All test conditions are on VDD = 5V / VSS = GND
Page 17
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Supply Voltage
Test conditions
Ratings
Unit
VDD-VSS
-0.3~6
V
Input Voltage
Vi-VSS
VSS-0.3~VDD+0.3
V
Output Voltage
Vo-VSS
VSS-0.3~VDD+0.3
V
Maximum Power
Consumption
Pa
500
mW
Operating Temperature
Topr
-10~70
C
Storage Temperature
Tstg
-40~125
C
VDD-VSS=5V
AC CHARACTERISTICS
Oscillator Frequency:455KHz/32.768KHz
Ratings
Parameter
Symbol
Unit
Min.
Key Press Duration
t key
Remote Input Bit Duration
t bit
Typ.
Max.
30
1.17
Page 18
1.68
ms
2.18
ms
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
SM5021 (ENCODER) APPLICATION CIRCUIT
R2
4.7
D2
IR LED
JP1
JP2
BT
3V
C1
VDD
C2
DOUT
K1/ OFF
LEDO
K2/ SPEED
OSC2
K3/ MODE
OSC1
K4/ TIMER
SLEEP/K8
SW1
K5/ SWING
LIGHT/K7
Vss
SW2/K6
ON-OFF
C1
10u
Q1
NPN
D1
LED
Q2
NPN
455K
R1
1K
SM5021A/B
SM3015 POWER SUPPLY APPLICATION CIRCUIT
100K/1W
1A
47 
/1W
110V AC INPUT
1N4004
3.3uF/250V
1N4004
47 
/ 0.25W
47 
/ 0.25W
5.1V
0.5W
220uF
16V
VSS/-5.1V
470uF
16V
3.3K 
GND
1A
220V AC INPUT
180 
/ 1W
200K / 1W
180 
/ 1W
1.2uF / 400V
1N4004
1N4004
220uF
16V
47 
/ 0.25W
47 
/ 0.25W
5.1V
0.5W
VSS/-5.1V
470uF
16V
3.3K 
GND
Page 19
V.4.0 Dec 21,2005
SAMHOP Microelectronics Corp.
SM3015
REMOTE FAN MCU
Page 20
V.4.0 Dec 21,2005
SAMHOP Microelectronics Corp.
SM3015
REMOTE FAN MCU
Page 21
V.4.0 Dec 21,2005
SM3015
SAMHOP Microelectronics Corp.
REMOTE FAN MCU
ORDERING INFORMATION
Logo
Product No.
A: A Type
B: B Type
Empty:455KHz
X:32.768KHz
A: ON/OFF Key Start-up
B: SPEED Key Start-up
M: Memory Function
N: Non-memory Function
4: 0.5HR, 1HR, 2HR, 4HR
8: 1HR, 2HR, 4HR, 8HR
A: Timer Setting-Ladder Adder
B: Timer Setting-Shift
SM3015 A-X
A M 4 A - F L 2 ST L
xxxxxxxxxxxx
L :Lead free
G:Green
O: One Operation Wind Mode
T: Two Operation Wind Mode
Empty: Three Operation Wind Mode
S: Tuner Control In Swing2
F: Tuner Control In Swing1
N: Non-Tuner Control
2: Two Swing Head Control
1: One Swing Head Control
N: Non-Swing Head Control
L: Light Function (Independence)
D: Light Function (Dependence)
N: Non-Light Function
F: Four Steps For Timer
T: Three Steps For Timer
Date Code