AD4C212 - Solid State Optronics

AD4C212
Dual 1 Form B
Solid State Relay
DESCRIPTION
The AD4C212 is a bi-directional, double-pole, single-throw, normally closed multipurpose solid-state relay. It is designed to replace
electromechanical relays in general purpose switching applications. The relay consists of two integrated circuits, each driving a pair of
rugged source-to-source depletion type DMOS transistors. Each integrated circuit is optically coupled to a light emitting diode. The output
MOS transistors are protected with free-wheeling diodes that can handle up to 1.5A of inrush current, making the relay ideal for switching
lamps and highly inductive loads.
FEATURES
APPLICATIONS
•
Two isolated 1 form B SSRs in compact 8pin DIP package
•
Multiplexers
•
Low input control power consumption (1.5mA TYP)
•
Meter reading systems
•
140mA maximum continuous load current
•
Data Acquisition
•
25 ohms maximum on-resistance
•
Medical equipment
•
High input-to-output isolation
•
Battery monitoring
•
Long life/high reliability
•
Home/Safety security systems
•
RoHS Compliant / Pb Free / Reach Compliant
OPTIONS/SUFFIXES*
•
-S
Surface Mount Leadform Option (50 pcs / tube)
•
-TR
Tape and Reel Option (1,000 pcs / reel)
NOTE: Suffixes listed above are not included in marking on
device for part number identification.
SCHEMATIC DIAGRAM
ABSOLUTE MAXIMUM RATINGS*
PARAMETER
UNIT
MIN
Storage Temperature
°C
-55
125
Operating Temperature
°C
-40
85
Continuous Input Current
mA
40
Transient Input Current
mA
400
Reverse Input Control
Voltage
V
Output Power Dissipation
mW
TYP
MAX
6
800
*The values indicated are absolute stress ratings. Functional operation of the
device is not implied at these or any conditions in excess of those defined in
electrical characteristics section of this document. Exposure to Absolute
Ratings may cause permanent damage to the device and may adversely
affect reliability.
APPROVALS
•
© 2011 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
Page 1 of 5
UL / C-UL Approved: File E201932
AD4C212
rev 1.41 (2/1/2011)
AD4C212
Dual 1 Form B
Solid State Relay
ELECTRICAL CHARACTERISTICS - 25°C
PARAMETER
UNIT
MIN
TYP
MAX
1.2
1.5
TEST CONDITIONS
INPUT SPECIFICATIONS
LED Forward Voltage
V
LED Reverse Voltage
6
12
V
Turn-On Current
mA
0.75
Turn-Off Current
mA
1.5
If = 10mA
Ir = 10uA
Io = 140mA
5
OUTPUT SPECIFICATIONS
Blocking Voltage
V
Continuous Load Current
mA
On-Resistance
Leakage Current
Output Capacitance
Offset Voltage
400
Io = 1uA
140
If = 0mA
Ω
18.5
25
Io = 140mA
µA
0.3
1
Vo = 400V
pF
25
50
Vo = 25V, f = 1.0MHz
0.2
If = 0mA
mV
COUPLED SPECIFICATIONS
Isolation Voltage
Turn-On Time
3750
V
T = 1 minute
ms
0.25
Turn-Off Time
ms
0.85
Isolation Resistance
GΩ
Coupled Capacitance
pF
Contact Transient Ratio
© 2011 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
V/
1
If = 0mA, Io = 140mA
3
If = 5mA, Io = 140mA
100
2
µs
2000
Page 2 of 5
7000
dV = 50V
AD4C212
rev 1.41 (2/1/2011)
AD4C212
Dual 1 Form B
Solid State Relay
AD4C212
AD4C212
Typical Turn-On Time Distribution
N = 100, Ambient Temperature = 25°C
Typical Turn-Off Time Distribution
N = 100, Ambient Temperature = 25°C
60
50
40
30
20
10
0
50
Device Cou
40
30
20
10
0
0.03 0.03 0.04 0.04 0.05 0.05 0.06 0.06
0.65 0.7 0.75 0.8 0.85 0.9 0.95
Turn-On Tim e (m s)
AD4C212
AD4C212
Typical On-Resistance Distribution
N = 100, Ambient Temperature = 25°C
Typical Leakage Current Distribution
N = 100, Ambient Temperature = 25°C
Device Cou
30
20
10
0
16.5
17
17.5
18
18.5
19
19.5
20
60
50
40
30
20
10
0
0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5
On-Resistance (ohm s)
Leakage Current (uA)
AD4C212
AD4C212
Typical Blocking Voltage Distribution
N = 100, Ambient Temperature = 25°C
Maximum Load Current vs. Temperature
0
Blocking Voltage (V)
© 2011 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
0
-4
0
400 410 420 430 440 450 460 470
50
80
10
100
60
30
20
150
40
40
-2
0
Load Current (m
50
20
Device Cou
40
Device Cou
1
Turn-Off Tim e (m s)
0
Device Cou
PERFORMANCE DATA
Tem perature (C)
Page 3 of 5
AD4C212
rev 1.41 (2/1/2011)
AD4C212
Dual 1 Form B
Solid State Relay
MECHANICAL DIMENSIONS
8 PIN DUAL IN-LINE PACKAGE
8 PIN SURFACE MOUNT DEVICE
END VIEW
END VIEW
TOP VIEW
TOP VIEW
BOTTOM VIEW/
BOARD PATTERN
BOTTOM VIEW/
BOARD PATTERN
© 2011 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
Page 4 of 5
AD4C212
rev 1.41 (2/1/2011)
AD4C212
Dual 1 Form B
Solid State Relay
DISCLAIMER
Solid State Optronics (SSO) makes no warranties or representations with regards to the completeness and accuracy of this document. SSO
reserves the right to make changes to product description, specifications at any time without further notice.
SSO shall not assume any liability arising out of the application or use of any product or circuit described herein. Neither circuit patent
licenses nor indemnity are expressed or implied.
Except as specified in SSO's Standard Terms & Conditions, SSO disclaims liability for consequential or other damage, and we make no other
warranty, expressed or implied, including merchantability and fitness for particular use.
LIFE SUPPORT POLICY
SSO does not authorize use of its devices in life support applications wherein failure or malfunction of a device may lead to personal injury or
death. Users of SSO devices in life support applications assume all risks of such use and agree to indemnify SSO against any and all
damages resulting from such use. Life support devices are defined as devices or systems which, (a) are intended for surgical implant into the
body, or (b) support or sustain life, and (c) whose failure to perform when used properly in accordance with instructions for use can be
reasonably expected to result in significant injury to the user, or (d) a critical component in any component of a life support device or system
whose failure can be reasonably expected to cause failure of the life support device or system, or to affect its safety or effectiveness.
© 2011 Solid State Optronics • San José, CA
www.ssousa.com • +1.408.293.4600
Page 5 of 5
AD4C212
rev 1.41 (2/1/2011)