DATA SHEET SKY13437: 0.4 to 2.7 GHz SP12T Switch with GPIO Interface Applications 2G/3G/4G multimode cellular handsets (LTE, UMTS, CDMA2000, EDGE, GSM) Embedded data cards TRX1 TRX2 TRX3 Features TRX4 Broadband frequency range: 0.4 to 2.7 GHz Low insertion loss High isolation and linearity Integrated GSM harmonic filter Integrated GPIO interface Ten TRX ports, one GSM low band transmit port, and one GSM high band transmit port TRX5 Description The SKY13437 is a single-pole, twelve-throw (SP12T) antenna switch with integrated GSM transmit harmonic filter. The SKY13437 maintains a high linearity, high isolation, and low insertion loss performance, which makes it an ideal choice for UMTS, CDMA2000, EDGE, GSM, and LTE applications. The design features two dedicated GSM transmit ports. The remaining ten ports are suitable for WCDMA transmit/receive and GSM receive functions. Three transmit ports (TRX1, TRX2, and TRX4) have been specifically designed to provide optimal LTE Band 13 performance. The switch exhibits an excellent triple beat ratio and 2nd/3rd order modulation distortion performance. TRX8 (RX1) TRX9 (RX2) TRX10 (RX3) HTX LTX VC1 VC2 VC3 Decoder VC4 Skyworks Green™ products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of Green™, document number SQ04-0074. ANT TRX7 VDD Small MCM (22-pin, 3.2 x 2.5 x 0.8 mm) package (MSL3, 260 C per JEDEC J-STD-020) TRX6 S2831 Figure 1. SKY13437 Block Diagram Switching is controlled by an integrated GPIO interface. Depending on the logic applied to the decoder, the antenna pin is connected to one of 12 switched RF ports using a low insertion loss path, while the paths between the antenna pin and the other RF pins are in a high isolation state. No external DC blocking capacitors are required on the RF paths as long as no DC voltage is applied. The SKY13437 is manufactured in a compact, 3.2 x 2.5 x 0.8 mm, 22-pin surface mount Multi-Chip Module (MCM) package. A functional block diagram is shown in Figure 1. The pin configuration and package are shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201791C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 26, 2014 1 TRX5 TRX6 TRX7 GND 15 14 13 12 18 10 GND VC3 19 9 LTX VC2 20 8 HTX VC1 21 7 GND TRX3 22 6 TRX8 (RX1) 1 2 3 4 5 TRX9 (RX2) ANT GND 11 TRX10 (RX3) VC4 16 TRX1 17 TRX2 VDD TRX4 DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE S2842 Figure 2. SKY13437 Pinout – 22-Pin MCM (Top View) Table 1. SKY13437 Signal Descriptions (Note 1) Pin Name Description Pin Name Description 1 TRX2 RF input/output port 2 optimized for LTE Band 13 (704 to 787 MHz) 12 GND Ground 2 TRX1 RF input/output port 1 optimized for LTE Band 13 (704 to 787 MHz) 13 TRX7 RF input/output port 7 3 TRX10 (RX3) RF input/output port 10 (receive 3) 14 TRX6 RF input/output port 6 4 GND Ground 15 TRX5 RF input/output port 5 5 TRX9 (RX2) RF input/output port 9 (receive 2) 16 TRX4 RF input/output port 4 optimized for LTE Band 13 (704 to 787 MHz) 6 TRX8 (RX1) RF input/output port 8 (receive 1) 17 VDD DC power supply 7 GND Ground 18 VC4 DC input control voltage 4 8 HTX GSM high band transmit RF input port with integrated harmonic filter 19 VC3 DC input control voltage 3 9 LTX GSM low band transmit RF input port with integrated harmonic filter 20 VC2 DC input control voltage 2 10 GND Ground 21 VC1 DC input control voltage 1 11 ANT Antenna RF port 22 TRX3 RF input/output port 3 Note 1: Bottom ground paddles must be connected to ground. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 September 26, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201791C DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Table 2. SKY13437 Absolute Maximum Ratings (Note 1) Parameter Minimum Maximum Units VDD 2.45 5.00 V Digital control signals (VC1, VC2, VC3, VC4) VCTRL –0.5 +3.0 V RF input power: LTX pin HTX pin All TRXx pins PIN +36 +34 +31 dBm dBm dBm Storage temperature TSTG –55 +150 C Operating temperature TOP –40 +90 C Power supply Symbol Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device. CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Electrical and Mechanical Specifications The absolute maximum ratings of the SKY13437 are provided in Table 2. Electrical specifications are provided in Tables 3 through 6. Table 7 provides the control logic for the SKY13437. Tabel 8 shows the insertion loss matrix. The isolation matrices shown in Tables 9 and 10 provide the port-to-port isolation and the antenna-to-port isolation for all available RF states at four different frequencies: 915 MHz, 1910 MHz, 2170 MHz, and 2690 MHz. Figure 3 illustrates the test setup used to measure intermodulation products. This industry standardized test is used to simulate the WCDMA Band 1 linearity of the antenna switch. A +20 dBm Continuous Wave (CW) signal, fFUND, is sequentially applied to the TRX1 through TRX10 ports, while a –15 dBm CW blocker signal, fBLK, is applied to the ANT port. The resulting 3rd Order Intermodulation Distortion (IMD3), fRX, is measured over all phases of fFUND. The SKY13437 exhibits exceptional performance for all TRXx ports. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201791C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 26, 2014 3 DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Table 3. SKY13437 Electrical Specifications (Note 1) (1 of 3) (VDD = 2.85 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units RF Specifications Insertion loss, LTX (Note 2) IL 824 to 915 MHz 1.35 1.5 dB Insertion loss, HTX (Note 2) IL 1710 to 1910 MHz 1.2 1.5 dB Insertion loss, TRX1/2/4 (Note 2) IL 704 to 787 MHz 0.55 0.65 dB Insertion loss, TRX1/2/3 (Note 2) IL 824 to 960 MHz 1710 to 1990 MHz 2110 to 2170 MHz 2300 to 2690 MHz 0.6 0.75 0.75 0.75 0.7 0.85 0.85 0.95 dB dB dB dB Insertion loss, TRX4/5/6/7 (Note 2) IL 824 to 960 MHz 1710 to 1990 MHz 2110 to 2170 MHz 0.65 0.8 0.8 0.75 0.95 1 dB dB dB Insertion loss, TRX4/5/6 (Note 2) IL 2300 to 2690 MHz 0.9 1.25 dB Insertion loss, TRX8/9/10 (Note 2) IL 824 to 960 MHz 1710 to 1990 MHz 2110 to 2170 MHz 2300 to 2690 MHz 0.6 0.75 0.75 0.8 0.7 0.9 0.95 1 dB dB dB dB GSM harmonic attenuation H2LB LTX to ANT, 2fo 1648 to1830 MHz 23 31 dB H3LB LTX to ANT, 3fo 2472 to 2745 MHz 26 29 dB H4LB LTX to ANT, 4fo 3296 to 3660 MHz 36 dB H2HB HTX to ANT, 2fo 3420 to 3820 MHz 25 31 dB H3HB HTX to ANT, 3fo 5130 to 5730 MHz 26 29 dB Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 September 26, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201791C DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Table 3. SKY13437 Electrical Specifications (Note 1) (2 of 3) (VDD = 2.85 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units LTX1 to TRx ports, 824 MHz to 915 MHz 40 44.5 dB HTX to TRx ports, 1710 to 1910 MHz 29 33 dB TRx1 to TRx3, TRx2 to TRx10, TRx4 to TRx6, TRx5 to TRx7, 824 to 1910 MHz (non-adjacent ports) 25 28 dB TRx1/2 to TRx3/4/5 824 to 1910 MHz (opposite ports) 35 41 dB TRx1 to TRx10, TRx2 to TRx3, TRx4 to TRx5, TRx6 to TRx7 824 MHz to 1910 MHz (adjacent ports) 20 22 dB ANT to TRX9 port when TRX10 is ON 1805 MHz to 1990 MHz 30 35 dB ANT to TRX10 port when TRX9 is ON 1805 MHz to 1990 MHz 30 35 dB LTX to HTX when LTX is ON, 1648 to 1830 MHz 25 27.5 dB RF Specifications (continued) Isolation (Note 2) Iso Large signal harmonics LTX_HARM Transmit GSM low band, PIN <+34.5 dBm, VSWR = 1:1 –57 –45 dBm LTX_HARM_VSWR Transmit GSM low band, PIN <+34.5 dBm, VSWR = 5:1, all phases –43 –36 dBm HTX_HARM Transmit GSM high band, PIN <+32 dBm, VSWR = 1:1 –61 –48 dBm Transmit GSM high band, PIN <+32 dBm, VSWR = 5:1, all phases –42 –37 dBm ANT to TRX1/2/4 ports @ 786.5 MHz, PIN <+25 dBm, VSWR = 1:1 –78 TRXx for f0 up to 915 MHz, PIN <+27 dBm, VSWR = 1:1 –71 –66 dBm TRXx for f0 up to 1910 MHz, PIN <+27 dBm, VSWR = 1:1 –70 –66 dBm HTX_HARM_VSWR B13_HARM TRXx_HARM TRXx_HARM dBm Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201791C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 26, 2014 5 DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Table 3. SKY13437 Electrical Specifications (Note 1) (3 of 3) (VDD = 2.85 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units RF Specifications (continued) 2nd Order Intermodulation Distortion IMD2 CW carrier on TRXx ports with POUT = +20 dBm, CW interferer on ANT port with PIN = –15 Bm, all blocker frequencies –107 –100 dBm 3rd Order Intermodulation Distortion IMD3 CW carrier on TRXx ports with POUT = +20 dBm, CW interferer on ANT port with PIN = –15dBm, all blocker frequencies –110 –107 dBm Triple beat ratio TBR Band 5 (see Table 6) +81 +92 dBc Band 2 (see Table 6) +81 +86 dBc 2.50 2.85 4.80 V 35 85 μA 35 85 μA 1.80 1 2.70 0.45 5 V V μA 2 20 μs 2 5 μs 20 mVp-p DC Specifications Supply voltage VDD Supply current: GSM850/EGSM900/DCS1800/ PCS1900 transmit WCDMA/CDMA2000 transmit/receive IDD Digital control signals: High Low Current VC1, VC2, VC3, VC4 1.35 0 DC supply turn-on/turn-off time RF path switching time Between the ANT port and any LTX/HTX or TRXx ports Supply ripple Note 1: Performance is guaranteed only under the conditions listed in this table. Note 2: See Tables 8, 9, and 10 for complete insertion loss and isolation matrices. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 6 September 26, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201791C DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Table 4. SKY13437 Electrical Specifications: IP3 Frequencies and Power Levels (Note 1) (VDD = 2.85 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Band Transmit Frequency (MHz) Transmit Power (dBm) Frequency Blocker (MHz) Power Blocker (dBm) Receive Frequency (MHz) 1 1950.0 +20 1760.0 –15 2140.0 2 1880.0 +20 1800.0 –15 1960.0 4 1732.0 +20 1332.0 –15 2132.0 5 836.5 +20 791.5 –15 881.5 8 897.0 +20 852.0 –15 942.0 Note 1: Performance is guaranteed only under the conditions listed in this table. Table 5. SKY13437 Electrical Specifications: IP2 Frequencies and Power Levels (Note 1) (VDD = 2.85 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Band Transmit Frequency (MHz) Transmit Power (dBm) Frequency Blocker 1 (MHz) Frequency Blocker 2 (MHz) Power Blocker (dBm) Receive Frequency (MHz) 1 1950.0 +20 190 4090 –15 2140.0 2 1880.0 +20 80 3840 –15 1960.0 4 1732.0 +20 400 3864 –15 2132.0 5 836.5 +20 45 1718 –15 881.5 8 897.0 +20 45 1839 –15 942.0 Note 1: Performance is guaranteed only under the conditions listed in this table. Table 6. SKY13437 Electrical Specifications: Triple Beat Ratio Frequencies and Power Levels (Note 1) (VDD = 2.85 V, TOP = +25 C, Characteristic Impedance [ZO] = 50 Ω, Unless Otherwise Noted) Band Transmit Frequency 1 (MHz) Transmit Power 1 (dBm) Transmit Frequency 2 (MHz) Transmit Power 2 (dBm) Frequency Blocker @ ANT (MHz) Power Blocker (dBm) 2 1880.0 +21.5 1881.0 +21.5 1960.0 –30 1960 ± 1 5 836.5 +21.5 881.5 +21.5 881.5 –30 881.5 ± 1 Triple Beat Product Frequency (MHz) Note 1: Performance is guaranteed only under the conditions listed in this table. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201791C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 26, 2014 7 DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Table 7. SKY13437 Mode Control Logic Insertion Loss State VC1 (Pin 21) VC2 (Pin 20) VC3 (Pin 19) VC4 (Pin 18) LTX 0 0 1 0 HTX 1 0 1 0 TRX10 (RX3) 1 0 0 0 TRX9 (RX2) 1 0 0 1 TRX8 (RX1) 1 1 0 1 TRX7 0 1 0 0 TRX6 0 1 1 0 TRX5 0 0 0 0 TRX4 1 1 1 0 TRX3 1 0 1 1 TRX2 1 1 0 0 TRX1 1 1 1 1 0 0 0 1 Sleep (all ports in isolation state) Note: “1” = 1.8 V typical. “0” = 0 V to +0.4 V. Any state other than described in this table places the switch into an undefined state. An undefined state will not damage the device. Table 8. Insertion Loss Matrix Frequency (MHz) Insertion Loss (dB) LTX HTX TRx1 TRx2 TRx3 TRx4 TRx5 TRx6 TRx7 TRx8 TRx9 TRx10 915 –1.26 –0.94 –0.49 –0.50 –0.54 –0.51 –0.56 –0.58 –0.59 –0.55 –0.55 –0.53 1910 –30.89 –1.29 –0.65 –0.65 –0.69 –0.64 –0.69 –0.70 –0.73 –0.69 –0.66 –0.65 2170 –26.95 –1.71 –0.67 –0.68 –0.72 –0.69 –0.75 –0.77 –0.81 –0.71 –0.70 –0.69 2690 –31.13 –6.63 –0.75 –0.72 –0.75 –0.85 –0.94 –1.05 –1.19 –0.79 –0.82 –0.77 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 8 September 26, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201791C DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Table 9. Port-To-Port Isolation Matrix (1 of 2) “On” Port Frequency (GHz) Isolation (dB) LTX HTX TRX1 TRX2 TRX3 TRX4 TRX5 TRX6 TRX7 TRX8 TRX9 TRX10 LTX 915 – –26 –52 –53 –55 –57 –54 –50 –50 –45 –50 –52 LTX 1910 – –31 –51 –53 –53 –51 –48 –45 –42 –36 –42 –49 LTX 2170 – –27 –51 –52 –53 –50 –48 –44 –41 –35 –41 –49 LTX 2690 – –21 –51 –52 –53 –51 –48 –45 –41 –36 –41 –49 HTX 915 –27 – –48 –50 –51 –58 –57 –52 –53 –37 –44 –48 HTX 1910 –27 – –43 –44 –45 –45 –45 –42 –42 –34 –40 –43 HTX 2170 –26 – –44 –44 –45 –44 –44 –41 –41 –37 –42 –44 HTX 2690 –21 – –56 –53 –55 –52 –53 –48 –52 –34 –41 –56 TRX1 915 –34 –73 – –28 –34 –56 –60 –54 –56 –49 –44 –32 TRX1 1910 –41 –46 – –22 –28 –44 –46 –44 –43 –42 –38 –27 TRX1 2170 –40 –44 – –22 –27 –42 –44 –42 –41 –40 –37 –26 TRX1 2690 –39 –41 – –19 –25 –39 –42 –40 –38 –37 –35 –24 TRX2 915 –34 –68 –30 – –28 –53 –60 –55 –56 –51 –46 –38 TRX2 1910 –41 –46 –25 – –23 –43 –46 –44 –43 –43 –40 –33 TRX2 2170 –40 –43 –24 – –22 –41 –44 –42 –41 –41 –39 –32 TRX2 2690 –39 –40 –21 – –20 –38 –41 –40 –38 –38 –36 –30 TRX3 915 –34 –65 –34 –31 – –49 –57 –56 –56 –53 –48 –41 TRX3 1910 –41 –45 –29 –26 – –41 –45 –44 –43 –44 –42 –36 TRX3 2170 –40 –42 –28 –25 – –39 –43 –42 –41 –42 –40 –35 TRX3 2690 –39 –39 –26 –23 – –36 –40 –40 –38 –39 –38 –33 TRX4 915 –35 –59 –50 –48 –48 – –28 –36 –40 –58 –55 –52 TRX4 1910 –41 –44 –43 –42 –41 – –23 –30 –33 –46 –47 –45 TRX4 2170 –40 –41 –42 –40 –40 – –22 –29 –31 –44 –45 –44 TRX4 2690 –39 –39 –40 –38 –39 – –19 –26 –28 –41 –42 –42 TRX5 915 –35 –58 –51 –50 –50 –31 – –29 –37 –57 –55 –53 TRX5 1910 –41 –44 –44 –43 –43 –25 – –23 –30 –46 –47 –46 TRX5 2170 –40 –41 –42 –41 –41 –24 – –22 –29 –44 –45 –44 TRX5 2690 –39 –39 –40 –39 –40 –22 – –20 –26 –41 –42 –42 TRX6 915 –36 –56 –52 –51 –51 –36 –32 – –30 –57 –55 –53 TRX6 1910 –41 –44 –44 –44 –44 –30 –26 – –23 –46 –47 –46 TRX6 2170 –41 –41 –43 –42 –42 –29 –25 – –22 –43 –45 –44 TRX6 2690 –39 –39 –40 –40 –40 –26 –22 – –20 –40 –42 –42 TRX7 915 –37 –53 –52 –51 –52 –40 –38 –33 – –55 –54 –53 TRX7 1910 –41 –43 –44 –44 –45 –33 –32 –26 – –45 –46 –46 TRX7 2170 –40 –41 –43 –42 –43 –31 –30 –25 – –43 –44 –44 TRX7 2690 –38 –39 –40 –40 –41 –28 –28 –22 – –40 –42 –41 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201791C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 26, 2014 9 DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Table 9. Port-To-Port Isolation Matrix (2 of 2) “On” Port Frequency (GHz) Isolation (dB) LTX HTX TRX1 TRX2 TRX3 TRX4 TRX5 TRX6 TRX7 TRX8 TRX9 TRX10 TRX8 915 –34 –44 –42 –45 –47 –60 –58 –53 –56 – –30 –38 TRX8 1910 –48 –34 –37 –39 –41 –46 –46 –44 –43 – –24 –32 TRX8 2170 –47 –34 –36 –38 –40 –43 –45 –42 –41 – –24 –31 TRX8 2690 –39 –31 –34 –36 –38 –40 –43 –40 –38 – –21 –29 TRX9 915 –34 –56 –40 –43 –45 –60 –58 –53 –56 –38 – –33 TRX9 1910 –44 –43 –34 –38 –40 –45 –46 –43 –43 –31 – –27 TRX9 2170 –44 –47 –34 –37 –39 –43 –45 –42 –41 –29 – –27 TRX9 2690 –40 –42 –32 –34 –36 –41 –43 –41 –38 –27 – –24 TRX0 915 –34 –72 –29 –37 –40 –59 –59 –53 –56 –44 –40 – TRX10 1910 –41 –46 –24 –32 –35 –45 –46 –44 –44 –37 –34 – TRX10 2170 –41 –44 –23 –31 –34 –43 –45 –42 –42 –35 –33 – TRX10 2690 –39 –42 –21 –29 –32 –40 –43 –41 –38 –32 –30 – Table 10. Antenna-To-Port Isolation Matrix (1 of 2) “On” Port Frequency (GHz) Isolation (dB) LTX HTX TRX1 TRX2 TRX3 TRX4 TRX5 TRX6 TRX7 TRX8 TRX9 TRX10 LTX 915 – –27 –49 –49 –50 –45 –44 –42 –40 –44 –47 –49 LTX 1910 – –30 –48 –47 –47 –39 –37 –34 –35 –42 –46 –48 LTX 2170 – –34 –50 –49 –49 –40 –37 –35 –36 –43 –47 –50 LTX 2690 – –46 –51 –52 –51 –41 –38 –35 –37 –45 –48 –51 HTX 915 –29 – –54 –53 –54 –46 –45 –43 –42 –44 –53 –56 HTX 1910 –27 – –43 –43 –44 –38 –38 –35 –35 –36 –40 –44 HTX 2170 –25 – –41 –41 –42 –37 –36 –34 –33 –35 –38 –42 HTX 2690 –28 – –41 –41 –42 –35 –35 –32 –33 –36 –40 –42 TRX1 915 –41 –41 – –34 –43 –48 –46 –43 –42 –50 –58 –38 TRX1 1910 –39 –38 – –27 –34 –41 –40 –37 –36 –41 –44 –31 TRX1 2170 –38 –39 – –26 –33 –39 –39 –36 –35 –40 –42 –30 TRX1 2690 –36 –46 – –25 –32 –37 –37 –34 –33 –37 –39 –29 TRX2 915 –42 –41 –40 – –34 –49 –47 –44 –42 –49 –58 –44 TRX2 1910 –39 –38 –31 – –27 –41 –40 –37 –36 –41 –45 –37 TRX2 2170 –38 –39 –30 – –26 –39 –39 –36 –35 –40 –43 –36 TRX2 2690 –36 –47 –28 – –25 –37 –37 –34 –33 –37 –40 –35 TRX3 915 –42 –41 –48 –42 – –51 –48 –44 –42 –49 –56 –51 TRX3 1910 –39 –38 –36 –32 – –42 –41 –38 –36 –41 –45 –41 TRX3 2170 –38 –39 –34 –31 – –40 –39 –37 –35 –40 –43 –40 TRX3 2690 –36 –48 –32 –29 – –37 –37 –34 –33 –37 –40 –38 Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 10 September 26, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201791C DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Table 10. Antenna-To-Port Isolation Matrix (2 of 2) “On” Port Frequency (GHz) Isolation (dB) LTX HTX TRX1 TRX2 TRX3 TRX4 TRX5 TRX6 TRX7 TRX8 TRX9 TRX10 TRX4 915 –43 –41 –51 –54 –58 – –35 –48 –43 –47 –49 –51 TRX4 1910 –38 –38 –44 –44 –45 – –27 –34 –33 –41 –43 –44 TRX4 2170 –37 –39 –42 –42 –42 – –26 –32 –32 –39 –42 –43 TRX4 2690 –36 –48 –40 –39 –40 – –25 –29 –29 –37 –39 –40 TRX5 915 –43 –42 –51 –52 –56 –44 – –37 –46 –47 –49 –50 TRX5 1910 –38 –39 –44 –44 –46 –32 – –28 –33 –41 –43 –44 TRX5 2170 –37 –40 –42 –42 –43 –30 – –27 –31 –39 –42 –43 TRX5 2690 –35 –48 –40 –40 –41 –27 – –25 –29 –37 –39 –40 TRX6 915 –44 –42 –50 –51 –54 –51 –44 – –39 –47 –49 –50 TRX6 1910 –38 –39 –44 –44 –46 –36 –33 – –28 –41 –43 –44 TRX6 2170 –37 –40 –42 –42 –43 –33 –31 – –27 –39 –42 –43 TRX6 2690 –35 –48 –40 –40 –41 –31 –29 – –25 –37 –40 –40 TRX7 915 –50 –43 –50 –51 –53 –45 –51 –47 – –48 –50 –50 TRX7 1910 –39 –39 –43 –43 –45 –35 –37 –33 – –41 –43 –44 TRX7 2170 –38 –40 –42 –42 –43 –33 –35 –30 – –39 –42 –42 TRX7 2690 –35 –46 –39 –39 –41 –30 –32 –28 – –37 –39 –40 TRX8 915 –40 –35 –57 –59 –60 –46 –45 –43 –42 – –38 –56 TRX8 1910 –38 –29 –45 –45 –47 –40 –39 –37 –36 – –30 –40 TRX8 2170 –36 –28 –43 –43 –45 –39 –38 –36 –35 – –29 –38 TRX8 2690 –33 –28 –41 –40 –42 –36 –36 –34 –33 – –27 –35 TRX9 915 –41 –39 –49 –56 –60 –46 –45 –43 –42 –43 – –44 TRX9 1910 –39 –35 –41 –44 –47 –40 –39 –37 –36 –33 – –35 TRX9 2170 –37 –35 –40 –43 –45 –39 –38 –36 –35 –31 – –34 TRX9 2690 –35 –36 –39 –41 –43 –36 –36 –34 –33 –28 – –33 TRX0 915 –41 –40 –34 –42 –47 –47 –45 –43 –42 –43 –44 – TRX10 1910 –39 –37 –27 –35 –39 –40 –39 –37 –36 –36 –36 – TRX10 2170 –38 –37 –26 –34 –39 –39 –38 –36 –35 –34 –34 – TRX10 2690 –36 –43 –26 –34 –38 –37 –36 –34 –33 –31 –31 – Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201791C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 26, 2014 11 DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE fBLK 1760 MHz, –15 dBm fFUND 1950 MHz, +20 dBm fRX 2140 MHz, Measure Tone Circulator Signal Generator fFUND = 1950 MHz, +20 dBm Coupler to Monitor Input Power 1950 MHz Bandpass Filter Circulator Duplexer Phase Shifter SKY13437 fFUND = +20 dBm fBLK = –15 dBm 1760 MHz Bandpass Filter Signal Generator fBLK = 1760 MHz, –15 dBm Spectrum Analyzer fRX = 2140 MHz Y1422 rd Figure 3. 3 Order Intermodulation Test Setup Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 12 September 26, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201791C DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Evaluation Board Description Package and Handling Information The SKY13437 Evaluation Board is used to test the performance of the SKY13437 SP12T Switch. An Evaluation Board schematic diagram is provided in Figure 4. A recommended ESD protection circuit diagram is provided in Figure 5. An assembly drawing for the Evaluation Board is shown in Figure 6. Instructions on the shipping container label regarding exposure to moisture after the container seal is broken must be followed. Otherwise, problems related to moisture absorption may occur when the part is subjected to high temperature during solder assembly. Package Dimensions The SKY13437 is rated to Moisture Sensitivity Level 3 (MSL3) at 260 C. It can be used for lead or lead-free soldering. For additional information, refer to the Skyworks Application Note, PCB Design and SMT Assembly/Rework Guidelines for MCM-L Packages, document number 101752. The PCB layout footprint for the SKY13437 is provided in Figure 7. Typical case markings are shown in Figure 8. Package dimensions for the 22-pin MCM are shown in Figure 9, and tape and reel dimensions are provided in Figure 10. Care must be taken when attaching this product, whether it is done manually or in a production solder reflow environment. Production quantities of this product are shipped in a standard tape and reel format. 6-Pin Header 6 GND 5 VC1 4 VC2 3 VC3 2 VC4 VDD 1 RF I/O Port 6 RF I/O Port 5 RF I/O Port 7 L1 47 nH 21 22 C6 33 pF GND TRX7 TRX6 ANT VC4 GND VC3 LTX 11 8 VC2 VC1 TRX3 RF I/O, Port 3 1 2 3 HTX 4 Antenna 10 9 TRX9 (RX2) 20 C5 33 pF 12 GND Control Voltage 1 19 C4 33 pF 13 TRX10 (RX3) Control Voltage 2 18 VDD 14 TRX1 Control Voltage 3 17 C3 33 pF 15 TRX4 Control Voltage 4 16 TRX5 DC Supply TRX2 RF I/O Port 4 7 GND Low Band TX RF Input High Band TX RF Input 6 TRX8 (RX1) RF I/O, Port 8 (Receive 1) 5 RF I/O, Port 2 RF I/O, Port 9 (Receive 2) RF I/O, Port 1 RF I/O, Port 10 (Receive 3) Y1423 NOTE: Bypass capacitor on the VDD is not recommended. Figure 4. SKY13437 Evaluation Board Schematic Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201791C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 26, 2014 13 DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE 4.7 pF To Application Antenna To SKY13437 Antenna (Pin 11) 18 nH 18 nH ESD Circuit 1 12 pF To Application Antenna To SKY13437 Antenna (Pin 11) 12 nH ESD Circuit 2 Y1424 Figure 5. SKY13437 Recommended ESD Protection Circuits TRX6 TRX7 TRX5 ANT TRX4 LTX VDD VC4 1 VC3 VC2 VC1 GND 3 2 HTX 4 5 6 TRX8 TRX3 TRX9 TRX2 TRX1 TRX10 Y1425 Notes: Inductor L1 (pin 17 trace) is not shown in this drawing, but is included in the schematic and on the actual Evaluation Board. Capacitors C1 and C2 are designated as DNP (Do Not Place). Figure 6. SKY13437 Evaluation Board Assembly Diagram Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 14 September 26, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201791C DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE 3.5 22X 0.55 18X 0.2 4X 0.5 0.4 Pitch 2.8 2X 0.5 Package Outline Pin 1 Indicator (0.30 X 45°) Pin 1 Pin 22 Stencil aperture size for center ground pad should be 80 to 100% (by area) of the solder mask opening. 2X 0.5 Stencil Aperture Top View 0.6 Pitch 3.6 17X 0.55 Package Outline 22X 0.65 18X 0.3 14X 0.2 4X 0.5 4X 0.6 0.4 Pitch 0.4 Pitch 0.6 Pitch 2.8 2X 0.5 Pin 1 Indicator (0.30 X 45°) Pin 22 Pin 1 0.25 Typ. 3.5 Metallization Top View Opening size of 60 to 100% of exposed center opening shown Pin 1 2X 0.5 Pin 22 Thermal via array Ø0.3 mm on 0.6 mm pitch will improve thermal performance. NOTE: thermal vias should be resin filled and capped according to IPC-4761, Type VII vias. 30-35 μm Cu thickness recommended. 2.9 Package Outline Solder Mask Opening Top View All dimensions are in millimeters S3226 Figure 7. SKY13437 PCB Layout Footprint (Top View) Pin 1 Indicator Skyworks Part # Lot # Date Code: YY = Year WW = Week Figure 8. Typical Part Markings (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201791C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 26, 2014 15 3.2 Solder Mask Opening 0 C 12X 1.45 DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE 0.2 A B C B 14X 1.1 B C 4X 0.6 4X 0.2 2.5 0 A Pin 22 22X SMT Pad A 0.1 M A B C 4X 0.8 0.8 ± 0.1 0.1 0.15 A B C Top View Side View 4X 0.4 Pin 1 Indicator Pin 1 Indicator See Detail D Pin 1 Bottom View 0.25 ± 0.1 0.25 ± 0.1 0.25 ± 0.1 (0.15) 1 (0.15) 0.3 ± 0.05 Soldermask Edges (0.15) 0.2 ± 0.1 0.2 ± 0.05 0.2 ± 0.1 1 (0.05) (0.15) (0.15) 0.3 X 0.3 Metal Pad Edge 5X R0.05 Max Detail A Detail B Detail C Pad Scale: 2X 4X This Rotation 4X Rotated 180° 5X Rotated 270° 5X Rotated 90° Pad Scale: 2X 1X This Rotation 1X Rotated 180° Pad Scale: 2X 1X This Rotation 1X Rotated 180° Detail D Full Scale 1X This Rotation All measurements are in millimeters Dimensioning and tolerancing according to ASME Y14.5M-1994 Figure 9. SKY13437 22-Pin MCM Package Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 16 September 26, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201791C S3225 DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE 0.25 ± 0.05 ∅1.50 +0.10/–0 2.00 ± 0.05 4.00 ± 0.10 1.75 ± 0.10 A A B ∅1.00 ± 0.10 1.30 ± 0.10 (Ko) B 5.50 ± 0.05 3.50 ± 0.10 (Bo) Pin #1 Indicator 12.00 ± 0.20 B 4.00 ± 0.10 2.75 ± 0.10 (Ao) Notes: 1. Carrier tape: black conductive polycarbonate. 2. Cover tape material: transparent conductive material. 3. ESD-surface resistivity is ≤1 x 1010 Ohms/square per EIA, JEDEC TNR Specification. 4. 10 sprocket hole pitch cumulative tolerance: ±0.20 mm 5. Ao and Bo measusred on plane 0.30 mm above the bottom of the pocket. 6. All measurements are in millimeters. A S2686 Figure 10. SKY13437 Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 201791C • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • September 26, 2014 17 DATA SHEET • SKY13437: SP12T SWITCH WITH GPIO INTERFACE Ordering Information Model Name SKY13437: 0.4 to 2.7 GHz SP12T Switch Manufacturing Part Number SKY13437 Evaluation Board Part Number SKY13437-EVB Copyright © 2012-2014 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks and the Skyworks symbol are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 18 September 26, 2014 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 201791C