Product Summary - Skyworks Solutions, Inc.

PRODUCT SUMMARY
SKY77593 Tx-Rx FEM for Quad-Band GSM / GPRS / EDGE
with Four Linear TRx Switch Ports and Dual-Band TD-SCDMA
Applications
Description
• Quad-band GSM/EDGE and DualBand TD-SCDMA cellular handsets
encompassing
- Class 4 GSM850 / 900
- Class 1 DCS1800 / PCS1900
- Class 12 GPRS
multi-slot operation
- 4 low insertion loss / high
linearity interchangeable TRx
switch ports
- Linear EDGE operation
- TD-SCDMA Bands 34/39
SKY77593 is a transmit and receive Front End Module (FEM) designed in a very low profile
(0.9 mm) and compact form factor for quad-band cellular handsets comprising GSM850/900,
DCS1800 / PCS1900 operation and dual-band TD-SCDMA bands 34 and 39 operation—a
complete transmit VCO-to-Antenna and Antenna-to-receive SAW filter solution. The FEM also
supports Class 12 General Packet Radio Service (GPRS) multi-slot operation and linear EDGE
operation. 3G switch-through support is provided by four dedicated high-linearity ports.
The module consists of a GSM850/900 PA and DCS1800/PCS1900/TD-SCDMA PA block,
impedance-matching circuitry for 50 Ω input and output impedances, Tx harmonic filtering, a
high linearity/low insertion loss switch, and a CMOS Power Amplifier Control (PAC) block. A
custom silicon integrated circuit contains decoder circuitry to control the RF switch while
Features
providing a low current, external control interface.
• Small, low profile package
- 6 mm x 6 mm x 0.9 mm
- 28-pad configuration
Fabricated in GaAs, the Heterojunction Bipolar Transistor (HBT) PA blocks support the
GSM850/900 bands and DCS1800/PCS1900 bands and TD-SCDMA bands 34/39. Both PA
• Low input power range
0 dBm to 6 dBm
blocks share common power supply pads to distribute current. The output of the PA block and
• High efficiency
antenna switch. The 3G and Rx ports feature a 0 volts DC offset level which eliminates the
• Tx-VCO-to-antenna and antennato-Rx-SAW filter RF interface
need for external blocking capacitors. The GaAs die, switch die, CMOS controller die, and
• Tx harmonics below –38 dBm
is encapsulated with plastic overmold.
• Current limiting for over-voltage
protection and extended battery
life
RF input and output ports of the SKY77593 are internally matched to a 50 Ω load to reduce the
• Input/Output matched internally to
50 Ω
maximizes handset standby time. Control of transmit and receive RF signal flows, and band
• High impedance control inputs:
20 µA, maximum
• Power control circuitry built-in for
improved TRP variation
the outputs to the four receive pads connect to the antenna pad through a high-linearity
passive components are mounted on a multi-layer laminate substrate and the entire assembly
number of external components on the phone board. Extremely low leakage current of the FEM
selection are performed by four external control pads (see Figure 1 on overleaf). Mode of
operation, Tx vs. Rx, and Band (GSM850, GSM900, DCS1800, PCS1900, and Bands 34/39) are
controlled with the four logic inputs: Mode, TxEN, BS1, and BS2. Proper timing of the TxEN
input and the VRAMP input ensures high isolation between the antenna and Tx-VCO while the
VCO is being tuned prior to the transmit burst.
The integrated power amplifier control (PAC) function provides envelope amplitude control
while reducing sensitivity to input drive, temperature, power supply, and process variation.
Output power variation into mismatch is minimized with Skyworks’ Finger-Based Integrated
Power Amplifier Control (FB-iPAC) control circuit.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
202846A • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice. • May 3, 2013
1
Ordering Information
Product Name
Order Number
SKY77593 Tx-Rx Front-End Module
SKY77593
Evaluation Board Part Number
© 2013, Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by
Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of
Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A
PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY
DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS
SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION,
LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any
damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, “Breakthrough Simplicity,” DCR, Helios, HIP3, Innovation to Go, Intera, iPAC, LIPA, Polar Loop, and System Smart are trademarks or registered trademarks of
Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional
information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference.