SKYWORKS SKY77555

PRODUCT SUMMARY
SKY77555 Tx–Rx FEM Based on CMOS PA for Dual-Band
GSM / GPRS (880–915 MHz and 1710–1785 MHz)
Applications
Description
• Dual-band cellular handsets
encompassing
- Class 4 GSM900
- DCS1800
- Class 12 GPRS multi-slot
operation
The SKY77555 is a transmit and receive front-end module (FEM) based on CMOS Power Amplifier for
dual-band cellular handsets comprising GSM900 and DCS1800 operation. Designed in a low profile,
compact form factor, the SKY77555 offers a complete Transmit VCO-to-Antenna and Antenna-toReceive SAW filter solution. The FEM also supports Class 12 General Packet Radio Service (GPRS)
multi-slot operation.
Features
• Efficiency
- 36% GSM (33.0 dBm)
- 29% DCS (30.5 dBm)
• Log linear power control
response with <100 dB/V
power control slope
• Low Rx band noise
• Supply current
- 1.58 A GSM (33.0 dBm)
- 1.10 A DCS (30.5 dBm)
• Fully integrated closed loop
• 50 Ω matched Input/Output
The module consists of a GSM900/DCS1800 CMOS PA, Tx harmonics filtering, high linearity and low
insertion loss PHEMT RF switches, and diplexer. The CMOS device integrates a full dual-band
GSM/GPRS power amplifier function. High accuracy power control and ramping is achieved on the
CMOS chip via a closed loop power control system. Current drain is limited under load mismatch
conditions via the nature of the innovative power control circuit. The output of the CMOS PA die and
the outputs to the two receive pads are connected to the antenna pad through PHEMT RF switches
and a diplexer. The CMOS die, PHEMT die, and passive components are mounted on a multi-layer
laminate substrate. The assembly is encapsulated with plastic overmold.
Band selection and control of transmit and receive modes are performed using two external control
pads. Refer to the functional block diagram in Figure 1. The band select pad (BS) selects between
GSM and DCS modes of operation. The transmit enable (TxEN) pad controls the receive or transmit
mode of the respective RF switch (Tx = logic 1). Proper timing between transmit enable (TxEN) and
Analog Power Control (VRAMP) allows for high isolation between the antenna and Tx-VCO while the
VCO is being tuned prior to the transmit burst.
The SKY77555 is compatible with logic levels from 1.6 V to 2.8 V for BS and TxEN pads, depending on
the level applied to the VLOGIC pad. This feature provides additional flexibility for the designer in the
selection of FEM interface control logic.
• Tx–VCO-to-antenna and
antenna-to-Rx-SAW filter
RF interface
• PHEMT RF switches afford
high linearity, low insertion
loss, and low current in
receive modes
• Small, low profile package
- 5 mm x 6 mm x 1.05 mm
• Compatible with multiple
logic families
Figure 1. SKY77555 Functional Block Diagram
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201256A • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice. • March 3, 2010
1
©2010, Skyworks Solutions, Inc. All Rights Reserved
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided
by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the
information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to
update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or
information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions
of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR
A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY
EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS.
SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT
LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED
OF THE POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury,
death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for
any damages resulting from such improper use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of
products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for
applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, “Breakthrough Simplicity,” DCR, Helios, HIP3, Innovation to Go, Intera, iPAC, LIPA, Polar Loop, and System Smart are trademarks or registered trademarks of
Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional
information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference.