FEATURES
· 100 mbar to 10 bar, 1 to 150 psi
gage or differential pressure
· Increased media compatibility1
· Analog output
· Precision ASIC signal conditioning
· Calibrated and temperature compensated2
· SIL and DIP housings
· RoHS compliant
· Quality Management System according
to ISO 13485:2003 and ISO 9001:2008
MEDIA COMPATIBILITY1,2
High pressure port: To be used with gases and
liquids which are compatible with the wetted
materials (high temperature polyamide, ceramic
AL2O3, epoxy, fluorosilicone, glass, silicon).
Low pressure port: To be used with non-corrosive,
non-ionic working fluids such as clean dry air, dry
gases and the like.
SPECIFICATIONS
Maximum ratings
Supply voltage VS
HMA...3
HMA...5
Output current
Sink
Source
Environmental
Temperature ranges
Compensated
Operating
Storage3
Humidity limits (non-condensing)
ELECTRICAL CONNECTION
2.7 ... 4.2 VDC
4.2 ... 5.5 VDC
max. 6.5 VDC
1 mA
1 mA
+Vs
1
3
Vout
HMA
-20 ... +85 °C
-20 ... +85 °C
-40 ... +125 °C
...95 %RH10
(100 % condensing or direct liquid media on high pressure port1)
4
C
2
GND
100 nF
10 nF
100 nF
Vibration
max. 10 g, 10...2000 Hz, random
(EN 60068-2-64)
Mechanical shock
max. 50 g, 11 ms
(EN 60068-2-27)
Lead solder temperature
max. 270 °C
(JESD22-B106D)
E / 11697 / B
1/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PRESSURE SENSOR CHARACTERISTICS
(TA=25 °C, RH=50 %)
Part no.
HMAM100U...
HMAM100B...
HMAM250U...
HMAM250B...
HMAB001U...
HMAB001B...
HMAB2x5U...
HMAB005U...
HMAB010U...
HMAP001U...
HMAP001B...
HMAP100U...
Proof pressure4
Operating pressure
0...100 mbar
0...±100 mbar
0...250 mbar
0...±250 mbar
0...1 bar
0...±1 bar
0...2.5 bar
0...5 bar
0...10 bar
0...1 psi
0...±1 psi
0...100 psi
2 bar
2 bar
2 bar
2 bar
5 bar
5 bar
10 bar
14 bar
14 bar
3 0 p si
3 0 p si
2 0 0 p si
Other pressure ranges (e.g. 500 mbar, 5 psi, 150 psi) are available on request. Please contact First Sensor.
PERFORMANCE CHARACTERISTICS2
(VS=5.0 VDC, TA=25 °C, RH=50 %, analog output signal is ratiometric to VS in the range of VS =4.2...5.5 V)
All HMA...H5 devices (VS = 5.0)
Characteristics
Non-linearity (-20...85 °C)6
Accuracy7
Total accuracy (-20...85 °C)8
Response delay9
A/D resolution
D/A resolution
Current consumption
All HMA...U...H5 (unidirectional devices)
Characteristics
Zero pressure offset
Full scale span (FSS)5
Full scale output
All HMA...B...H5 (bidirectional devices)
Characteristics
Zero pressure offset
Full scale span (FSS)5
Output
at max. specified pressure
at min. specified pressure
E / 11697 / B
Min.
Typ.
Max.
±0.25
±0.25
±1.5
0.5
12
5.3
4.44
Min.
2.44
4.44
0.44
%FSS
ms
11
Min.
0.44
Units
bi t
mA
Typ.
0.50
4.00
4.50
Max.
0.56
Typ.
2.50
4.00
4.50
0.50
Max.
2.56
Units
V
4.56
4.56
0.56
Units
V
2/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PERFORMANCE CHARACTERISTICS2
(VS=3.0 VDC, TA=25 °C, RH=50 %, analog output signal is ratiometric to VS in the range of VS =2.7...4.2 V)
All HMA...H3 devices (VS = 3.0)
Characteristics
Non-linearity (-20...85 °C)6
Accuracy7
Total accuracy (-20...85 °C)8
Response delay9
A/D resolution
D/A resolution
Current consumption
All HMA...U...H3 (unidirectional devices)
Characteristics
Zero pressure offset
Full scale span (FSS)5
Full scale output
All HMA...B...H3 (bidirectional devices)
Characteristics
Zero pressure offset
Full scale span (FSS)5
Output
at max. specified pressure
at min. specified pressure
Min.
Typ.
Max.
±0.25
±0.25
±1.5
0.5
12
4.5
2.664
Min.
1.464
2.664
0.264
Typ.
0.30
2.40
2.70
Typ.
1.50
2.40
2.70
0.30
%FSS
ms
11
Min.
0.264
Units
bi t
mA
Max.
0.336
Units
V
2.736
Max.
1.536
2.736
0.336
Units
V
Specification notes:
1. All wetted materials are selected to give a high level of media compatibility. Media compatibility refers to media inside the
pressure port and lid. Improved media compatibility on high pressure port (backward side of sensor chip) since media has no
contact to electronic components. Nevertheless tests with the media used in the specific application are recommended.
2. Sensor is calibrated in air, changes in sensor behaviour based on physical effects caused by the specific media can occur.
Weight of the media and wetting forces can influence the sensor characteristics.
3. Storage temperature of the sensor without package.
4. Proof pressure is the maximum pressure which may be applied without causing durable shifts of the electrical parameters
of the sensing element.
5. Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure.
6. Non-linearity is the measured deviation based on Best Fit Straight Line (BFSL).
7. Accuracy is the combined error from non-linearity and hysteresis. Hysteresis is the maximum output difference at any point
within the operating pressure range for increasing and decreasing pressure.
8. Total accuracy is the combined error from offset and span calibration, non-linearity, pressure hysteresis, and temperature
effects. Calibration errors include the deviation of offset and full scale from nominal values.
9. Max. delay time between pressure change at the pressure die and signal change at the output.
10. Tested 1h, up to 85 °C.
Sensors are electronic components and should be handled only in ESD save environments.
E / 11697 / B
3/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION
1
2
3
4
HMA...U1... (SIL, axial no ports)
Pin
1
2
3
4
Connection
+Vs
GND
+Vout
C
first angle projection
High pressure
E / 11697 / B
dimensions in mm
4/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)
HMA...W1... (DIP, axial no ports)
5
4
6
3
7
2
8
1
Pin Connection
1
+Vs
2
GND
3
+Vout
4
C
5
I / C*
6
I / C*
7
I / C*
8
I / C*
* Internal connection.
Do not connect for
any reason
first angle projection
High pressure
E / 11697 / B
dimensions in mm
5/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)
1
2
3
4
HMA...U7... (SIL, 2 ports axial opposite side, barbed)
Pin
1
2
3
4
Connection
+Vs
GND
+Vout
C
High pressure port
first angle projection
dimensions in mm
E / 11697 / B
6/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)
1
2
3
4
HMA...X7... (SIL, 1 port axial, barbed)
Pin
1
2
3
4
Connection
+Vs
GND
+Vout
C
High pressure port
first angle projection
dimensions in mm
E / 11697 / B
7/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)
HMA...Z7... (DIP, 1 port axial, barbed)
5
4
6
3
7
2
8
1
Pin Connection
1
+Vs
2
GND
3
+Vout
4
C
5
I / C*
6
I / C*
7
I / C*
8
I / C*
* Internal connection.
Do not connect for
any reason
High pressure port
first angle projection
dimensions in mm
E / 11697 / B
8/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)
1
2
3
4
HMA...U6... (SIL, 2 ports axial opposite side, straight big)
Pin
1
2
3
4
Connection
+Vs
GND
+Vout
C
High pressure port
first angle projection
dimensions in mm
E / 11697 / B
9/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)
1
2
3
4
HMA...X6... (SIL, 1 port axial, straight big)
Pin
1
2
3
4
Connection
+Vs
GND
+Vout
C
High pressure port
first angle projection
dimensions in mm
E / 11697 / B
10/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)
HMA...Z6... (DIP, 1 port axial, straight big)
5
4
6
3
7
2
8
1
Pin Connection
1
+Vs
2
GND
3
+Vout
4
C
5
I / C*
6
I / C*
7
I / C*
8
I / C*
* Internal connection.
Do not connect for
any reason
High pressure port
first angle projection
dimensions in mm
E / 11697 / B
11/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)
1
2
3
4
HMA...U5... (SIL, 2 ports axial opposite side, needle big)
Pin
1
2
3
4
Connection
+Vs
GND
+Vout
C
High pressure port
first angle projection
dimensions in mm
E / 11697 / B
12/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)
1
2
3
4
HMA...X5... (SIL, 1 port axial, needle big)
Pin
1
2
3
4
High pressure port
Connection
+Vs
GND
+Vout
C
first angle projection
dimensions in mm
E / 11697 / B
13/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
PHYSICAL DIMENSIONS AND ELECTRICAL CONNECTION (cont.)
HMA...Z5... (DIP, 1 port axial, needle big)
5
4
6
3
7
2
8
1
High pressure port
Pin Connection
1
+Vs
2
GND
3
+Vout
4
C
5
I / C*
6
I / C*
7
I / C*
8
I / C*
* Internal connection.
Do not connect for
any reason
dimensions in mm
E / 11697 / B
14/15
www.first-sensor.com
www.sensortechnics.com
HMA Series
Amplified pressure sensors
NOMENCLATURE
Series Pressure range
Options
HMA
Calibration
M100 100 mbar B Bidirectional
M250 250 mbar U Unidirectional
B 001
1 bar
B 2x5
2.5 bar
B 005
5 bar
B 010
10 bar
P 001
1 p si
P 100
1 0 0 p si
Housing
Porting
U SIL, 2 ports axial
opposite side
(W) DIP, 2 ports axial
opposite side
X
Z
(1) no port
Grade
Voltage
H High
(3) 3 V
5 5V
7 Barbed
(5) Needle big
(6) Straight big
SIL, 1 port axial
DIP, 1 port axial
( ) available on request. Please contact First Sensor.
Example:
HMA
M100
U
U
7
H
5
LABEL INFORMATION
Digit
1 2 3
4
Series
C h ar
5
Pressure range
M A - HMA 6
1 p si
7
100 mbar
8
250 mbar
A
1 bar
B
2.5 bar
C
5 bar
L
1 0 0 p si
M
10 bar
6
7
8
Pressure unit /
Housing
Porting
pressure mode /
calibration
U bar,
U SIL,
1 no port
gage/differential,
2 ports axial
unidirectional
opposite side 7 Barbed
B bar,
W DIP,
5 Needle big
gage/differential,
2 ports axial
6
Straight big
bidirectional
opposite side
X SIL,
1 port, axial
9 10 11 12 13 14
Grade/
voltage
Production code
- High, 5 V
/ High, 3 V
Z DIP,
1 port axial
First Sensor reserves the right to make changes to any products herein.
First Sensor does not assume any liability arising out of the application
or use of any product or circuit described herein, neither does it convey
any license under its patent rights nor the rights of others.
E / 11697 / B
15/15
www.first-sensor.com
www.sensortechnics.com