KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media FEATURES · 250 mbar to 400 bar, 5 to 6000 psi gage1 or absolute11 pressure · For many industrial gases and liquids · 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or 4...20 mA output · Field interchangeable · EMC according to EN 61326-18 MEDIA COMPATIBILITY Wetted materials: Stainless steel 1.4404 (316L), ceramic Al2O3, NBR (FKM) Housing: Stainless steel, protection class IP 65 (according to DIN EN 60529, NEMA 4X)1 ELECTRICAL CONNECTION SPECIFICATIONS9,10 Maximum ratings Voltage output device Supply voltage (reverse polarity protection) KT...0... 13...32 V KT...1... 9...32 V KT...6..., ...7... 8...32 V 7...32 V KT...4...2 Maximum load current (source) KT...0..., ...1..., ...6..., ...7... Proof pressure3 400 bar/6000 psi devices all others +Vs 1 sensor Vout 3 -Vs V 2 1 mA case 1.5 x rated pressure 2 x rated pressure Current output device +Vs Temperature limits Storage Operating (media) Electronic (ambient) Compensated -40...85 °C -25...85 °C -25...85 °C 0...70 °C Vibration (5 to 500 Hz) 10 gRMS E / 11550 / D Vout -Vs Environmental Mechanical shock +Vs +Vs 1 N/C sensor 3 V -Vs RL -Vs 2 case 50 g 1/6 www.first-sensor.com www.sensortechnics.com KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media COMMON PERFORMANCE CHARACTERISTICS (VS=15 V ±0.1 V, TA=25 °C, RH=50 %) Characteristics Typ. Max. devices up to 1 bar/15 psi ±0.03 ±0.06 all others ±0.02 ±0.04 Span ±0.02 ±0.04 Offset ±0.03 Span Non-linearity (BSL), hysteresis and repeatability5 ±0.03 Thermal effects (0...70 °C)4 Offset Thermal effects (-25...0 °C, 70...85 °C)4 Min. KT...6N... ±0.2 ±0.5 all others ±0.1 ±0.3 ±0.1 ±0.3 6 Long term stability Output noise (0< f <1 kHz) %FSO/°C %FSO ±0.1 Response time (10 to 90 %) D/A resolution Power supply rejection Unit devices up to 350 mbar/5 psi 35 all others 5 ms 11 Offset ±0.01 Span ±0.02 bi t %FSO/V INDIVIDUAL PERFORMANCE CHARACTERISTICS (VS=15 V ±0.1 V, TA=25 °C, RH=50 %) 0...10 V output (RL > 100 kΩ) Characteristics Zero pressure offset Min. KT...6N... Max. Unit 0 0.1 V 10 10.1 5 all others Full scale span7 Typ. 9.9 Output impedance 25 Current consumption (no load) 4 Ω mA 0.5...4.5 V output (RL > 100 kΩ) Characteristics Zero pressure offset Min. KT...6N... all others 7 Full scale span Typ. E / 11550 / D Unit V 2.5 0.45 0.5 0.55 3.95 4 4.05 Output impedance Current consumption (no load) Max. 25 4 Ω mA 2/6 www.first-sensor.com www.sensortechnics.com KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media INDIVIDUAL PERFORMANCE CHARACTERISTICS (cont.) (TA=25 °C, RH=50 %, VS=15 V ±0.1 V) 0...5 V output (RL > 100 kΩ) Characteristics Zero pressure offset Min. Typ. Max. Unit V KT...6N... 2.50 all others 0 0.05 5.00 5.05 7 4.95 Full scale span Output impedance 25 Current consumption (no load) 4 W mA 1...6 V output (RL > 100 kΩ) Characteristics Zero pressure offset Min. KT...6N... Typ. Max. Unit V 3.50 all others 7 Full scale span 0.95 1.00 1.05 4.95 5.00 5.05 Output impedance 25 Current consumption (no load) 4 Ω mA 4...20 mA output (RL = 100 Ω) Characteristics Zero pressure offset Min. KT...6N... Typ. Max. Unit mA 12.0 all others 7 Full scale span 3.9 4.0 4.1 15.9 16.0 16.1 Power consumption (IL = 20 mA) 250 mW LOAD LIMITATION 4...20 mA output version 1400 Ohm 1200 1000 800 op e ra ratin ng g e 600 400 200 0 E / 11550 / D 5 7 10 16 20 25 30 32 V supply voltage 3/6 www.first-sensor.com www.sensortechnics.com KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media OUTLINE DRAWING KT...T... 23 (0.90) NOM 68 (2.68) 17 (0.67) 4.5 (0.18) 8.5 (0.33) 27.0 (1.06) diam. 6.0 HEX 27 (1.06) G1/2" (1/2" BSP) 12 (0.47) 4.5 (0.18) 1 2 NOM 68 (2.86) 8.5 (0.33) 12 (0.47) vent hole 3 KT...L... 27.0 (1.06) diam. G1/4" (1/4" BSP) HEX 27 (1.06) vent hole 3 KT...Q... 17 (0.67) 4.5 (0.18) 1 2 NOM 68 (2.68) 8.5 (0.33) vent hole 12 (0.47) 27.0 (1.06) diam. 3 1/4"NPT HEX 27 (1.06) 12 (0.47) KT...O... (flush mount) 13 (0.51) 12 (0.47) 1 2 NOM 68 (2.68) 8.5 (0.33) vent hole 12 (0.47) 27.0 (1.06) diam. G3/4" Hex 32 (1.26) 3 mass: approx. 200 g Pin dimensions in mm (inches) 1 2 3 E / 11550 / D 1 2 Output Voltage Current +Vs -Vs Vout C a se +Vs -Vs N/C C a se 4/6 www.first-sensor.com www.sensortechnics.com KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media RECOMMENDED ACCESSORY Plug DIN EN 175301-803 A and profile washer included in delivery. 34 3 50 31 M3 2 1 Note: For proper function of all gage devices the gage port must be vented to the atmosphere through the connector/cable assembly. Profile washer For a complete connector/cable assembly use order no. ZK000110-x (x=cable lenghts in m, max. 10 m). x = length in m (max. 10 m) NOM 60 PIN CONNECTION Pin Shrink hose Flying lead end 1 Brown 2 Yellow 3 Green White and bare NOM 20 dimensions in mm Specification notes: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. IP 65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter (see load limitation diagram). Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. Thermal effects are relative to 25 °C. Signal is clamped at 0 V. Non-linearity refers to Best Straight Line fit. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Long term stability is the change in output after one year. Full scale span is the algebraic difference between the output signal for the highest and lowest specified pressure. Surge immunity according to EN 61000-4-5 on request for current output devices. CE-labelling is in accordance with 2004/108/EC. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. Available for pressure ranges from 1 bar (15 psi) absolute upwards only. E / 11550 / D 5/6 www.first-sensor.com www.sensortechnics.com KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media ORDERING INFORMATION KTx 6xxx x x x x Sealing material V: Viton (FKM) N: NBR Note: Older part no. do not contain this digit. Without this digit NBR will be used. Calibration E: bar calibration U: psi calibration For mbar ranges only Pressure range KTE6000 series 250: 0...250 mbar 350: 0...350 mbar 500: 0...500 mbar 001: 0...1 bar N01: -1...+1 bar P01: 0...-1 bar 002: 0...2 bar 005: 0...5 bar 010: 0...10 bar 016: 0...16 bar 020: 0...20 bar 025: 0...25 bar 035: 0...35 bar 050: 0...50 bar 070: 0...70 bar 100: 0...100 bar 150: 0...150 bar 200: 0...200 bar 300: 0...300 bar 400: 0...400 bar M KTU6000 series 005: 0...5 psi 010: 0...10 psi 015: 0...15 psi N15: -15...+15 psi P15: 0...-15 psi 030: 0...30 psi 050: 0...50 psi 100: 0...100 psi 200: 0...200 psi 300: 0...300 psi 500: 0...500 psi 1K0: 0...1000 psi 1K5: 0...1500 psi 2K0: 0...2000 psi 3K0: 0...3000 psi 4K5: 0...4500 psi 6K0: 0...6000 psi Output signal 0: 0...10 V 1: 1...6 V 4: 4...20 mA 6: 0.5...4.5 V 7: 0...5 V Pressure connection L: 1/4" NPT male O: G 3/4" (3/4"BSP) only up to 16 bar/200 psi Q: G 1/4" (1/4" BSP) male T: G 1/2" (1/2" BSP) Other connections on special request Pressure mode G: gage pressure1 (up to 50 bar/750 psi) S: sealed gage (above 50 bar/750 psi) A: absolute pressure (from 1 bar/15 psi up to 50 bar/750 psi) Other pressure ranges and options are widely available. Please contact First Sensor. First Sensor reserves the right to make changes to any products herein. First Sensor does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. E / 11550 / D 6/6 www.first-sensor.com www.sensortechnics.com