KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media FEATURES · 0...-1 to 0...50 bar, 0...-15 to 0...750 psi gage1 or absolute · For many industrial gases and liquids · 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V or 4...20 mA output · Field interchangeable · For industrial use MEDIA COMPATIBILITY Wetted materials: PPS, ceramic Al2O3 and NBR8 Housing: stainless steel 1.4404 (316L), protection class IP 65 (according to DIN EN 60529) respectively NEMA 4X1 SPECIFICATIONS10,11 ELECTRICAL CONNECTION Maximum ratings 0...10 V, 0.5...4.5 V, 0...5 V, 1...6 V output Supply voltage (reverse polarity protection) KTx3...0 13...32 V KTx3...6 9...32 V KTx3...1, ...7 8...32 V KTx3...42 7...32 V Maximum load current Source/Sink -40...100°C -25...85°C 0...70°C Humidity limits 0 - 95 %RH Mechanical shock Proof pressure3 December 2008 / 626 Sensor 10 gRMS 50 g 2 x rated pressure 13 (8, 9)...32 V 1 Vout 3 -Vs V GND 2 1 mA Temperature limits Storage Operating Compensated Vibration (5 to 500 Hz) +Vs Internal connection (do not connect) 4... 20 mA output Sensor +Vs 1 N/C 3 -Vs 2 7...32 V V RL GND Internal connection (do not connect) 1/6 www.sensortechnics.com KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media COMMON PERFORMANCE CHARACTERISTICS (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Operating pressure Thermal effects (0...70°C)4 Thermal effects (-25...0°C, 70...85°C) Min. KTE3001... KTE3N01G... KTE3P01G... KTE3002... KTE3005... KTE3010... KTE3016... KTE3020... KTE3025... KTE3035... KTE3050... KTU3015... KTU3N15G... KTU3P15G... KTU3030... KTU3050... KTU3100... KTU3200... KTU3300... KTU3500... KTU3750... Offset Span Offset Span Non-linearity, hysteresis (BSL) and repeatability5 6 Typ. 0 -1 -1 0 0 0 0 0 0 0 0 0 -15 -15 0 0 0 0 0 0 0 0.02 0.02 0.03 0.03 ±0.1 Long term stability ±0.3 Output noise (0 < f < 1 kHz) ±0.04 Response time (10 to 90 %) 1 Power supply rejection 0.005 Max. 1 1 0 2 5 10 16 20 25 35 50 15 15 0 30 50 100 200 300 500 750 0.05 0.05 Unit bar p si %FSO/°C ±0.3 %FSO 5 ms %FSO/V Specification notes: 1. IP 65 protection is given when the connector is locked with a rubber washer. For proper function the gage port is vented to the atmosphere through the connector/cable assembly. Thus the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation diagram. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0 to 70°C relative to 25°C. All specifications shown are relative to 25°C. 5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Long term stability is the change in output after one year or 1 million pressure cycles. 7. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 8. Other sealing materials are available on request. 9. Test are in accordance with EN61000-6-2, April 1999. 10. CE-labelling is in accordance with 89/336/EEC. 11. The pressure transmitters must not be used as safety accessories according to article 1, 2.1.3 of the directive 97/23/EC. December 2008 / 626 2/6 www.sensortechnics.com KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media INDIVIDUAL PERFORMANCE CHARACTERISTICS 0...10 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset KT...3N... Min. Typ. Max. 4.9 5 5.1 0.03 0.1 all others 7 Full scale span KT...3N... 4.9 5 5.1 all others 9.9 10 10.1 Unit V 25 Ω 3 5 mA Min. Typ. Max. Unit KT...3N... 2.45 2.5 2.55 all others 0.45 0.5 0.55 KT...3N... 1.95 2 2.05 all others 3.95 4 4.05 Output impedance Current consumption (no load) 0.5...4.5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Full scale span7 25 Ω 3 5 mA Typ. Max. Unit Output impedance Current consumption (no load) V 0...5 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset Min. KT...3N... 2.45 all others Full scale span7 2.5 2.55 0.03 0.08 KT...3N... 2.45 2.5 2.55 all others 4.95 5.0 5.05 25 Ω 3 5 mA Unit Output impedance Current consumption (no load) V 1...6 V output (VS = 15 V, RL > 100 kΩ, tamb = 25°C) Characteristics Zero pressure offset 7 Full scale span Min. Typ. Max. KT...3N... 3.45 3.5 3.55 all others 0.95 1 1.05 KT...3N... 2.45 2.5 2.55 all others 4.95 5.0 5.05 25 Ω 3 5 mA Unit Output impedance Current consumption (no load) V 4...20 mA output (VS = 15 V, RL = 100 Ω, tamb = 25°C) Characteristics Zero pressure offset 7 Full scale span Power consumption (IL = 20 mA) December 2008 / 626 Min. Typ. Max. KT...3N... 11.9 12.0 12.1 all others 3.9 4.0 4.1 KT...3N... 7.9 8.0 8.1 all others 15.9 16.0 16.1 250 mA mW 3/6 www.sensortechnics.com KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media OUTPUT CHARACTERISTICS 0...10 V output version 0.5...4.5 V output version 10 10 Vout V 9 8 Vout 9 V 8 7 7 KTx3N... 6 6 5 4 5 KTx3P... KTx3N... 4 all other 3 3 KTx3P... all other 2 2 1 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure 0...5 V output version 1...6 V output version 10 Vout V 9 8 10 Vout V 9 8 7 7 6 6 4 KTx3N... 5 5 KTx3P... KTx3N... 4 KTx3P... 3 3 all other 2 2 all other 1 1 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure 4...20 mA output version 20 Iout 18 mA 16 14 12 KTx3P... 10 KTx3N... 8 6 all other 4 2 -100 -80 -60 -40 -20 0 +20 +40 +60 +80+100 % operating pressure December 2008 / 626 4/6 www.sensortechnics.com KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media OUTLINE DRAWING 12 (0.47) 4.5 (0.18) 12 (0.47) NOM 68 (2.86) vent hole 8.5 (0.33) 27.0 (1.06) diam. 30 (1.18) G1/4" (1/4" BSP) 3 1 2 mass: 210 g dimensions in mm (inches) LOAD LIMITATION RECOMMENDED ACCESSORY 4...20 mA output version Plug DIN EN 175301-803 A and profile washer included in delivery. For a complete connector/cable assembly use order no. ZK000110-x (x=cable lenghts in m). 1400 Ohm 1200 50 1000 800 34 op e ra ratin ng g e 600 400 Profile washer M3 200 31 0 5 7 10 16 dimensions in mm 20 25 30 32 V supply voltage Note: For proper function of all gage devices the gage port must be vented to the atmosphere through the connector/cable assembly. December 2008 / 626 5/6 www.sensortechnics.com KTE3000 / KTU3000 Series OEM pressure transmitters for industrial media ELECTROMAGNETIC CAPABILITY9 Test conditions Criterion Interference Radiated, radio frequency EN61000-4-3: Grade 3, 10 V/m, 80 to 1000 MHz A <1 %FSO electromagnetic field immunity (RFI) 80 % AMC (1 kHz) Electrical fast transient / EN61000-4-4: Grade 3, ±2 kV B <1 %FSO burst immunity (EFT) Electrostatic discharge immunity EN61000-4-2: Grade 4, ±8 kV, contact discharge B <1 %FSO test (ESD) Immunity to conducted disturbances EN61000-4-6: Grade 3, 0.15 to 80 MHz A <1 %FSO induced by radio-frequency fields 10 V, 80 % AMC (1 kHz) ORDERING INFORMATION KTx3 E: bar calibration U: psi calibration KTE3000 series 001: 0 to 1 bar N01: -1 to +1 bar P01: -1 to 0 bar 002: 0 to 2 bar 005: 0 to 5 bar 010: 0 to 10 bar 016: 0 to 16 bar 020: 0 to 20 bar 025: 0 to 25 bar 035: 0 to 35 bar 050: 0 to 50 bar Note: KTU3000 series 015: 0 to 15 psi N15: -15 to +15 psi P15: -15 to 0 psi 030: 0 to 30 psi 050: 0 to 50 psi 100: 0 to 100 psi 200: 0 to 200 psi 300: 0 to 300 psi 500: 0 to 500 psi 750: 0 to 750 psi xxx x x x Output signal 0: 0...10 V 1: 1...6 V 4: 4...20 mA 6: 0.5...4.5 V 7: 0...5 V Fitting size Q: G 1/4" (1/4" BSP) male Other fittings on special request Pressure mode G: gage pressure1 A: absolute pressure Other pressure ranges and options are widely available. Please contact your nearest Sensortechnics sales representative. Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. December 2008 / 626 6/6 www.sensortechnics.com